Filter by
Detects
Gas Leak Detected
Alert Type
Container Type
Electrical Connection
Maximum Temperature
Container Size
Measures
Display Type
Minimum Temperature
DFARS Specialty Metals
Certification
For Use On
Hazardous Location Protection Type
Surface-Mount Multi-Gas Detectors
Detects (Trigger Point) | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Propane (420 ppm); Methane (5,000 ppm); Hydrogen (200 ppm); Carbon Monoxide (150 ppm) | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | 120 | 6 | No | 3/16" | Canada | 6631T18 | 0000000 |
Methane Detectors
Trigger Point, ppm | Volume (Sound) @ Distance | Temp., ° F | Ht. | Wd. | Dp. | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 10,000 | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | 120 | 6 | No | 3/16" | Canada | 6631T43 | 0000000 |
Quick-Spot Compressed Gas Leak Detectors
![]() | ![]() | ![]() | |
Jug | Applicator-Top Bottle | Squeeze Bottle | Spray Bottle |
Container | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Oxygen Compatible | Temp. Range, ° F | Size | Type | Mil. Spec. | Food Industry Std. | Gas Leak Detected | Performance | Certification | Each | ||
| No | -35 to 200 | 1 gal. | Jug | MIL-PRF-25567 | — | Compressed Gas Leak | Quick Spot | Mil. Spec. | 10875T27 | 000000 | |
| No | 33 to 160 | 1 gal. | Jug | — | — | Compressed Gas Leak | Quick Spot | — | 1012T24 | 00000 | |
| No | 33 to 160 | 8 fl. oz. | Applicator-Top Bottle | — | — | Compressed Gas Leak | Quick Spot | — | 1012T22 | 0000 | |
| No | 33 to 160 | 8 fl. oz. | Squeeze Bottle | — | — | Compressed Gas Leak | Quick Spot | — | 1012T18 | 0000 | |
| No | 33 to 160 | 16 fl. oz. | Spray Bottle | — | — | Compressed Gas Leak | Quick Spot | — | 1012T101 | 0000 | |
| Yes | -65 to 200 | 1 gal. | Jug | MIL-PRF-25567 | — | Compressed Gas Leak | Quick Spot | Mil. Spec. | 10875T24 | 00000 | |
| Yes | -65 to 200 | 8 fl. oz. | Squeeze Bottle | MIL-PRF-25567 | — | Compressed Gas Leak | Quick Spot | Mil. Spec. | 10875T22 | 0000 | |
| Yes | 0 to 180 | 8 fl. oz. | Applicator-Top Bottle | MIL-PRF-25567 | NSF Registered P1 | Compressed Gas Leak | Quick Spot | Mil. Spec. | 10875T103 | 00000 | |
| Yes | 30 to 200 | 1 gal. | Jug | MIL-PRF-25567 | — | Compressed Gas Leak | Quick Spot | Mil. Spec. | 10875T12 | 00000 | |
| Yes | 30 to 200 | 8 fl. oz. | Squeeze Bottle | MIL-PRF-25567 | — | Compressed Gas Leak | Quick Spot | Mil. Spec. | 10875T11 | 0000 | |
| Yes | 33 to 160 | 4 fl. oz. | Squeeze Bottle | MIL-PRF-25567 | — | Compressed Gas Leak | Quick Spot | Mil. Spec. | 1012T16 | 0000 | |
| Yes | 35 to 175 | 1 gal. | Jug | MIL-PRF-25567 | NSF Registered P1 | Compressed Gas Leak | Quick Spot | Mil. Spec. | 10875T102 | 00000 | |
| Yes | 35 to 175 | 1 qt. | Spray Bottle | MIL-PRF-25567 | NSF Registered P1 | Compressed Gas Leak | Quick Spot | Mil. Spec. | 10875T101 | 00000 | |
Oxygen Detectors
Oxygen Detectors | Batteries | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Oxygen Volume Percent Concentration Measured | Volume (Sound) @ Distance | Ht. | Wd. | Dp. | Temp. Range, ° F | Batteries Included | Battery Chemistry | Hazardous Location Rating | Enclosure Rating | Each | Pkg. Qty. | Pkg. | ||||
Detectors with Nonreplaceable Battery | ||||||||||||||||
| 0% to 25% | 95 dBA @ 30 cm | 3 1/2" | 2" | 1" | -4 to 122 | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA AEx Ia IIC T4 ATEX II 2 G Ex Ia IIC T4 Gb IECEx Ex Ia IIC T4 | IP67 | 18995T81 | 0000000 | — | ——— | 0 | ||
Detectors with Replaceable Battery | ||||||||||||||||
| 0% to 25% | 95 dBA @ 30 cm | 3 1/2" | 2" | 1" | -4 to 122 | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 0 Groups IIC, IIB, IIA AEx Ia IIC T4 ATEX II 1 G Ex Ia IIC T4 Ga ATEX II 2 G Ex Ia IIC T4 Gb IECEx Ex Ia IIC T4 | — | 18995T92 | 000000 | 1 | 7821K72 | 00000 | ||
Carbon Dioxide Meters
Electrical | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Carbon Monoxide Concentration Measured Range, ppm | Temp. Range, ° F | Mobility | Ht. | Wd. | Dp. | Power Source | Batteries Included | No. of Batteries Req. | Battery Size | Connection | No. of Blades | Voltage, V AC | Cord Lg., ft. | Each | ||
| 0 to 9,999 | 32 to 122 | Portable | 8 1/4" | 2 1/2" | 1 1/2" | Battery, Electric | Yes | 6 | AAA | Straight Blade | 2 | 240 | 3 | 39035K691 | 0000000 | |
Gas Leak Detectors for Hard-to-Reach Areas
Detection Trigger Point, ppm | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Methane (Natural Gas) | Propane | Hydrogen | Butane | Acetone | Methanol | Ammonia | Gasoline | Chlorine | Acetylene | Ethane | Ethylene | Hydrogen Sulfide | Batteries Included | Container Type | Cannot Be Sold To | Each | ||
| 5 | 5 | 5 | 5 | 50 | 50 | 20 | 1 | 1 | 50 | 5 | 500 | 5 | Yes | Plastic Carrying Case | Outside North America | 1140T14 | 0000000 | |
Economy Gas Leak Detectors
Detectors | Replacement Batteries | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Detection Trigger Point, ppm | ||||||||||||||
Methane (Natural Gas) | Propane | Butane | Dia. | Lg. | Wt., oz. | Gas Leak Detected | Batteries Included | Features | Each | Pkg. Qty. | Pkg. | |||
| 10,000 | 10,000 | 10,000 | 1 1/4" | 7 1/2" | 4 | Butane, Methane, Propane | Yes | Wrist Strap | 1076T8 | 000000 | 4 | 71455K53 | 00000 | |
| 1,000 | 500 | — | 7/8" | 7" | 1 | Methane, Propane | Yes | Pocket Clip, Static Absorption Detector, Wrist Strap | 1076T11 | 00000 | 4 | 71455K62 | 0000 | |
Environmental-Monitoring Modules for Development Boards
Modules with Temperature, Humidity, and Air Quality Sensor
Output Data | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resolution, bit | Freq., Hz | Measures | Temp. Range, ° C | RH | Carbon Dioxide Concentration Measured, ppm | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Each | |||
I²C Communication Protocol—Qwiic Connection | |||||||||||||||
| 16 | 0.2 | Temperature, Relative Humidity, Carbon Dioxide Level | -10 to 60 | 0% to 100% | 0 to 40,000 | 2.4 to 5.5 | 0x62 | Solder | 2 | 1" | 1" | 7126N11 | 000000 | ||
Modules with Temperature, Humidity, Air Quality, and Barometer Sensor
Measures | Temp. Range, ° C | RH | Equiv. Carbon Dioxide Concentration Measured, ppm | Total Volatile Organic Compound, ppb | Barometric Pressure, in. Hg | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
I²C Communication Protocol—Qwiic Connection | |||||||||||||||
| Temperature, Relative Humidity, Equivalent Carbon Dioxide, Total Volatile Organic Compound Concentration, Air Quality Index, Barometric Pressure | 0 to 65 | 20% to 80% | 400 to 650,000 | 0 to 65,000 | 8.9 to 32.5 | 1.2 to 3.6 | 0x52 0x53 0x76 0x77 | Solder | 2 | 1" | 1" | 7126N14 | 000000 | ||
Combustion Analyzers
Measurement Range | Calculated Range | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Use On | Ambient Temp., ° F | Flue Gas Temp., ° F | Flue Gas Oxygen | Carbon Monoxide, ppm | Combustion Efficiency | Carbon Dioxide | Air Free Carbon Monoxide, ppm | Excess Air | Accuracy | Batteries Included | Each | ||
| Kerosene, Natural Gas, Oil, Propane | 25 to 110 | -4 to 1,200 | 0% to 20.9% | 0 to 2,000 | 0.1% to 100% | 0% to 15% | 0 to 9,999 | 0% to 250% | ±0.3% of Oxygen Content | Yes | 3937K35 | 0000000 | |
Portable Multi-Gas Detectors
Detects (Measuring Range) | Volume (Sound) @ Distance | Temp. Range, ° F | Batteries Included | Hazardous Location Rating | Enclosure Rating | Each | ||
|---|---|---|---|---|---|---|---|---|
| Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL) Oxygen (0% to 30% Vol.) Carbon Monoxide (0 ppm to 1,999 ppm) Hydrogen Sulfide (0 ppm to 200 ppm) | 95 dBA @ 30 cm | -40 to 140 | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA AEx Da Ia IIC T4 Ga Ex Da Ia IIC T4 Ga | IP68 | 18995T42 | 000000000 |
Acoustic Imaging Gas Leak Detectors
Max. Working Distance, ft. | Freq. Measured Range, kHz | Diag. Screen Size | Directional Resolution Range | Data Connection | Wt., lb. | Housing Material | Temp. Range, ° F | Enclosure Rating | Gas Leak Detected | Batteries Included | Container Type | Includes | Features | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 650 | 2 to 130 | 5" | 1°-0.125° | Wi-Fi, USB-A | 3.2 | Plastic | 0 to 120 | IP54 | Ammonia, Argon, Carbon Dioxide, Helium, Hydrogen, Methane, Compressed Gas Leak | Yes | Plastic Carrying Case | Battery Charger, Charging Cord, Lanyard, USB Drive | Memory Storage, LED Flashlight | 7203N12 | 0000000000 |
Early-Warning Surface-Mount Hydrogen Detectors
Trigger Point | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Electrical Connection | Voltage, V AC | Fasteners Included | Mounting Hole Dia. | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1%; 2% | 60 dB @ 10 ft. | 14 to 104 | 7" | 4 3/4" | 2 1/2" | Screw Terminal | 120, 240 | No | 3/16" | 71095K71 | 000000000 |
Portable Multi-Gas Detectors with Probe
Detects (Measuring Range) | Volume (Sound) @ Distance | Temp. Range, ° F | Batteries Included | Includes | Tube Lg., ft. | Hazardous Location Rating | Enclosure Rating | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL) Oxygen (0% to 30% Vol.) Carbon Monoxide (0 ppm to 1,999 ppm) Hydrogen Sulfide (0 ppm to 200 ppm) | 95 dBA @ 30 cm | -40 to 140 | Yes | Sampling Probe, Tubing Assembly, Battery | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA AEx Da Ia IIC T4 Ga Ex Da Ia IIC T4 Ga | IP68 | 18995T44 | 000000000 |
Propane Detectors
Trigger Point, ppm | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4,200 | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | 120 | 6 | No | 3/16" | Canada | 6631T41 | 0000000 |
Quick-Spot Vacuum and Pressure Gas Leak Detectors
Temp. Range, ° F | Container Net Wt., oz. | Gas Leak Detected | Performance | Container Type | Each | ||
|---|---|---|---|---|---|---|---|
| 35 to 170 | 14 | Pressure Leak, Vacuum Leak | Quick Spot | Aerosol Can | 6563T31 | 000000 |
Hydrogen Sulfide Detectors
Hydrogen Sulfide Concentration Measured, ppm | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Hazardous Location Rating | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nonreplaceable Batteries | ||||||||||||
| 0 to 100 | 95 dBA @ 30 cm | -4 to 122 | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 AEx Ia IIC T4 ATEX II 2 G Ex Ia IIC T4 Gb | IP67 | 18995T85 | 0000000 | ||
Replaceable Batteries | ||||||||||||
| 0 to 200 | 95 dBA @ 30 cm | 14 to 104 | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 Ga ATEX II 1 G Ex Ia IIC T4 Ga | IP67 | 18995T19 | 000000 | ||
Carbon Monoxide Detectors for Fire Alarm Systems
Volume (Sound) @ Distance | Mounting Profile | Lg. | Wd. | Dp. | Tandem Signaling Capable | Electrical Connection | Voltage, V DC | Current @ Voltage | Certification | Cannot Be Sold To | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 85 dBA @ 10 ft. | Surface | 4 1/2" | 3" | 1 1/2" | Yes | Screw Terminal | 12 24 | 0.04 amp @ 12V DC 0.04 amp @ 24V DC | UL Listed | Canada | 1030N1 | 0000000 | ||
Infrared Refrigerant Leak Detectors
Housing Material | Gas Leak Detected | Probe Lg. | Performance | Batteries Included | Container Type | Certification | Includes | Features | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Plastic | Hydrofluorocarbon (HFC), Chlorofluorocarbon (CFC), Hydrochlorofluorocarbon (HCFC), R-22 Refrigerant, R-134A Refrigerant, R-410A Refrigerant | 17" | Easy Read | Yes | Plastic Carrying Case | CE Marked | Charging Cord, Earbuds | Built-In Probe | Outside North America | 7394N11 | 000000000 |
Stick-On Carbon Monoxide Indicators
![]() |
Trigger Point, ppm | Mounting Profile | Ht. | Wd. | Backing Type | Each | |||
|---|---|---|---|---|---|---|---|---|
| 100 | Surface | 2 1/4" | 2 1/4" | Adhesive | 1085T85 | 00000 | ||
Surface-Mount Hydrogen Detectors
Electrical | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Trigger Point, ppm | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Connection | No. of Blades | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
| 8,000 | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | Straight Blade | 2 | 120 | 6 | No | 3/16" | Canada | 6631T42 | 0000000 | |
High-Visibility Quick-Spot Compressed Gas Leak Detectors
Container | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
Oxygen Compatible | Temp. Range, ° F | Size, fl. oz. | Type | Mil. Spec. | Gas Leak Detected | Performance | Certification | Each | ||
| Yes | -55 to 200 | 16 | Spray Bottle | MIL-PRF-25567 | Compressed Gas Leak | High Visibility, Quick Spot | Mil. Spec. | 6628T53 | 000000 | |
| Yes | 15 to 200 | 8 | Applicator-Top Bottle | MIL-PRF-25567 | Compressed Gas Leak | High Visibility, Quick Spot | Mil. Spec. | 6628T41 | 0000 | |
Portable Carbon Monoxide Detectors
Carbon Monoxide Concentration Measured, ppm | Volume (Sound) @ Distance | Temp., ° F | Ht. | Wd. | Dp. | Batteries Included | Certification | Hazardous Location Rating | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nonreplaceable Batteries | |||||||||||||
| 0 to 500 | 95 dBA @ 30 cm | -4 to 122 | 3 1/2" | 2" | 1" | Yes | CSA-US Certified CSA Certified CE Marked | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 ATEX II 2 G Ex Ia IIC T4 Gb AEx Ia IIC T4 | IP67 | 18995T83 | 0000000 | ||
Replaceable Batteries | |||||||||||||
| 0 to 2,000 | 95 dBA @ 30 cm | 14 to 104 | 3 1/2" | 2" | 1" | Yes | CSA-US Certified CSA Certified CE Marked | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 Ga ATEX II 1 G Ex Ia IIC T4 Ga | IP67 | 18995T15 | 000000 | ||
Refrigerant Leak Detectors
Detectors | Replacement Batteries | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Gas Leak Detected | Probe Lg. | Batteries Included | Container Type | Certification | Features | Specs. Met | Each | Pkg. Qty. | Pkg. | |||
| Hydrofluorocarbon (HFC), Chlorofluorocarbon (CFC), Hydrochlorofluorocarbon (HCFC), R-22 Refrigerant, R-134A Refrigerant, R-410A Refrigerant | 14" | Yes | Plastic Carrying Case | UL Recognized Component, CE Marked | Built-In Probe | SAE J2791, SAE J2913 | 1130T71 | 0000000 | 4 | 71455K53 | 00000 | |