McMaster-Carr logo
    Filter by
    System of Measurement
    Discharge Pipe Size
    Industrial Info Compare
    Intake Pipe Size
    Industrial Info Compare
    For Motor Power Source
    SAE Pump Flange Size
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    98 Products

    Hydraulic Gear Pumps

    These gear pumps have few moving parts so they're less prone to wear than other hydraulic pumps. Combine with an electric motor to generate flow in a hydraulic system. To mount to a NEMA C-face motor, use a Pump-to-Motor Mount (sold separately).
    SAE AA—3 1/4" Mounting Hole Center-to-Center
    Image of Product. Front orientation. Gear Pumps. Hydraulic Gear Pumps, AA.
    Image of Attribute. Front orientation. Contains Annotated. Hydraulic Gear Pumps, AA.
    UN/UNF (SAE Straight) Thread—UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Inlet Connection
    Outlet
    Connection
    Overall
    Shaft
    Fixed Displacement
    Rate, in³/rev
    Max. Flow
    Rate
    Max. Pressure,
    psi
    Max. Rotation
    Speed, rpm
    Thread
    Size
    Thread Type
    Dash
    Size
    Thread
    Size
    Thread Type
    Dash
    Size
    Lg.
    Ht.
    Dia.
    Lg.
    Choose a Drive Direction
    Each
    0.111.7 gpm2,5004,0007/8"-14
    UN/UNF (SAE Straight)
    103/4"-16
    UN/UNF (SAE Straight)
    084"3 5/8"1/2"1 1/4"Clockwise, Counterclockwise6296K440000000
    0.213.3 gpm2,5004,0007/8"-14
    UN/UNF (SAE Straight)
    103/4"-16
    UN/UNF (SAE Straight)
    084 1/4"3 5/8"1/2"1 1/4"Clockwise, Counterclockwise6296K45000000
    0.335.2 gpm2,5004,0007/8"-14
    UN/UNF (SAE Straight)
    103/4"-16
    UN/UNF (SAE Straight)
    084 3/8"3 5/8"1/2"1 1/4"Clockwise, Counterclockwise6296K47000000
    0.528.4 gpm2,5004,0007/8"-14
    UN/UNF (SAE Straight)
    103/4"-16
    UN/UNF (SAE Straight)
    084 3/4"3 5/8"1/2"1 1/4"Clockwise, Counterclockwise6296K53000000
    0.647.8 gpm2,0003,0007/8"-14
    UN/UNF (SAE Straight)
    103/4"-16
    UN/UNF (SAE Straight)
    084 7/8"3 5/8"1/2"1 1/4"Clockwise, Counterclockwise6296K55000000
     
    SAE A—4 3/16" Mounting Hole Center-to-Center
    Image of Product. Front orientation. Gear Pumps. Hydraulic Gear Pumps, A.
    Image of Attribute. Front orientation. Contains Annotated. Hydraulic Gear Pumps, A.
    UN/UNF (SAE Straight) Thread—UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Inlet Connection
    Outlet
    Connection
    Overall
    Shaft
    Fixed Displacement
    Rate, in³/rev
    Max. Flow
    Rate
    Max. Pressure,
    psi
    Max. Rotation
    Speed, rpm
    Thread
    Size
    Thread Type
    Dash
    Size
    Thread
    Size
    Thread Type
    Dash
    Size
    Lg.
    Ht.
    Dia.
    Lg.
    Choose a Drive Direction
    Each
    0.375.9 gpm4,0004,0007/8"-14
    UN/UNF (SAE Straight)
    103/4"-16
    UN/UNF (SAE Straight)
    084 7/8"4 5/8"3/4"1"Clockwise, Counterclockwise6296K250000000
    0.497.9 gpm4,0004,0001 1/16"-12
    UN/UNF (SAE Straight)
    127/8"-14
    UN/UNF (SAE Straight)
    105"4 5/8"3/4"1"Clockwise, Counterclockwise6296K26000000
    0.619.9 gpm4,0004,0001 1/16"-12
    UN/UNF (SAE Straight)
    127/8"-14
    UN/UNF (SAE Straight)
    105 1/8"4 5/8"3/4"1"Clockwise, Counterclockwise6296K27000000
    0.9811.9 gpm4,0003,0001 1/16"-12
    UN/UNF (SAE Straight)
    127/8"-14
    UN/UNF (SAE Straight)
    105 1/2"4 5/8"3/4"1"Clockwise, Counterclockwise6296K28000000
    1.1614.1 gpm4,0003,0001 5/16"-12
    UN/UNF (SAE Straight)
    161 1/16"-12
    UN/UNF (SAE Straight)
    125 5/8"4 5/8"3/4"1"Clockwise, Counterclockwise6296K29000000
    1.415.9 gpm3,2002,8001 5/16"-12
    UN/UNF (SAE Straight)
    161 1/16"-12
    UN/UNF (SAE Straight)
    125 7/8"4 5/8"3/4"1"Clockwise, Counterclockwise6296K37000000
    1.6516.1 gpm2,7002,4001 5/16"-12
    UN/UNF (SAE Straight)
    161 1/16"-12
    UN/UNF (SAE Straight)
    126 1/8"4 5/8"3/4"1"Clockwise, Counterclockwise6296K38000000
     
    SAE B—5 3/4" Mounting Hole Center-to-Center
    Image of Product. Front orientation. Gear Pumps. Hydraulic Gear Pumps, B.
    Image of Attribute. Front orientation. Contains Annotated. Hydraulic Gear Pumps, B.
    UN/UNF (SAE Straight) Thread—UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Inlet Connection
    Outlet
    Connection
    Overall
    Shaft
    Fixed Displacement
    Rate, in³/rev
    Max. Flow
    Rate
    Max. Pressure,
    psi
    Max. Rotation
    Speed, rpm
    Thread
    Size
    Thread Type
    Dash
    Size
    Thread
    Size
    Thread Type
    Dash
    Size
    Lg.
    Ht.
    Dia.
    Lg.
    Choose a Drive Direction
    Each
    2.0124.5 gpm4,0003,0001 5/8"-12
    UN/UNF (SAE Straight)
    201 5/16"-12
    UN/UNF (SAE Straight)
    167 1/8"5 7/8"7/8"1 1/4"Clockwise, Counterclockwise6296K390000000
    2.3228.3 gpm4,0003,0001 5/8"-12
    UN/UNF (SAE Straight)
    201 5/16"-12
    UN/UNF (SAE Straight)
    167 3/8"5 7/8"7/8"1 1/4"Clockwise6296K73000000
    3.0533.5 gpm2,9002,7001 5/8"-12
    UN/UNF (SAE Straight)
    201 5/16"-12
    UN/UNF (SAE Straight)
    167 3/4"5 7/8"7/8"1 1/4"Clockwise, Counterclockwise6296K59000000
     
    SAE 4F17—2" Mounting Hole Center-to-Center
    Image of Product. Front orientation. Gear Pumps. Hydraulic Gear Pumps, 4F17.
    Image of Attribute. Front orientation. Contains Annotated. Hydraulic Gear Pumps, 4F17.
    UN/UNF (SAE Straight) Thread—UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Inlet Connection
    Outlet
    Connection
    Overall
    Shaft
    Fixed Displacement
    Rate, in³/rev
    Max. Flow
    Rate
    Max. Pressure,
    psi
    Max. Rotation
    Speed, rpm
    Thread
    Size
    Thread Type
    Dash
    Size
    Thread
    Size
    Thread Type
    Dash
    Size
    Lg.
    Ht.
    Dia.
    Lg.
    Drive Direction
    Each
    0.070.8 gpm3,0004,0009/16"-18
    UN/UNF (SAE Straight)
    069/16"-18
    UN/UNF (SAE Straight)
    064 5/8"3 7/16"1/2"1 3/8"Clockwise, Counterclockwise6296K510000000
    0.131.7 gpm3,0004,0003/4"-16
    UN/UNF (SAE Straight)
    083/4"-16
    UN/UNF (SAE Straight)
    084 5/8"3 7/16"1/2"1 3/8"Clockwise, Counterclockwise6296K71000000
    0.395 gpm3,0004,0007/8"-14
    UN/UNF (SAE Straight)
    107/8"-14
    UN/UNF (SAE Straight)
    105 1/8"3 7/16"1/2"1 3/8"Clockwise, Counterclockwise6296K54000000
    0.715.4 gpm1,8002,4007/8"-14
    UN/UNF (SAE Straight)
    107/8"-14
    UN/UNF (SAE Straight)
    105 5/8"3 7/16"1/2"1 3/8"Clockwise, Counterclockwise6296K56000000
     

    Constant-Flow-Rate Gear Pumps for Water

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps for Water.
    These gear pumps produce a smooth flow of liquid for applications such as cooling engines, powering hydraulic equipment, and extracting liquid from holding tanks. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward. Do not use with solids. Pumps can be used in dusty, dirty, and damp environments.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Cannot Be Sold to Canada—Pumps that cannot be sold to Canada are restricted by local energy efficiency requirements.
    Intake
    (NPT)
    Discharge
    (NPT)
    Overall
    Max. Flow
    Rate, gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current
    Pipe
    Size
    Gender
    Pipe
    Size
    Gender
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    115V AC/230V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    2.1150100,00032 to 1401/27.4 amp/3.7 amp1/4
    Female1/4
    FemaleTotally Enclosed16 1/16"8 3/16"8"4272K31000000000
    8.5150100,00032 to 140112.8 amp/6.4 amp1/2
    Female1/2
    FemaleTotally Enclosed18 1/8"9 3/16"9"4272K2100000000
     
    230V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    10.2150100,00032 to 1401 1/24.4 amp/2.2 amp1/2
    Female1/2
    FemaleTotally Enclosed Fan-Cooled (TEFC)19 13/16"9 5/16"7 1/4"Canada4272K2200000000
    23150100,00032 to 14038.4 amp/4.2 amp1
    Female1
    FemaleTotally Enclosed Fan-Cooled (TEFC)25 1/8"10 5/16"9 1/16"Canada4272K2300000000
     

    Constant-Flow-Rate Gear Pumps without Motor for Water

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps without Motor for Water.
    These gear pumps have a bronze housing and gears for use with water. Select your own motor to tailor them to your application. Use a NEMA 56C frame electric motor with a coupling and belt/pulley drive. They produce a smooth flow of liquid for water delivery. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Required
    hp, hp
    Intake (NPT)
    Discharge (NPT)
    Overall
    Shaft
    Max. Flow Rate @
    25 psi, gpm
    Max. Flow
    Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    @ 25
    psi
    @ 100
    psi
    Pipe
    Size
    Connection
    Gender
    Pipe
    Size
    Connection
    Gender
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 1,725 rpm Maximum Motor Speed
    1.82.1 gpm34515017,300-20 to 2101/81/41/4
    ThreadedFemale1/4
    ThreadedFemale6 3/16"2 1/2"3"1/2"1 13/16"1 7/8"4271K10000000
    10.210.6 gpm34515017,300-20 to 2103/41 3/41/2
    ThreadedFemale1/2
    ThreadedFemale6 7/8"3 3/4"4 1/4"5/8"2"2 3/4"4271K14000000
    1919.8 gpm34515017,300-20 to 2101 1/22 3/43/4
    ThreadedFemale3/4
    ThreadedFemale7 1/16"4 3/8"5 1/4"5/8"2 3/16"3 9/16"4271K15000000
    22.223.5 gpm34515017,300-20 to 2101 1/22 3/41
    ThreadedFemale1
    ThreadedFemale7 5/16"4 5/16"5 1/4"5/8"2 3/16"3 9/16"4271K16000000
     
    For 1,750 rpm Maximum Motor Speed
    77.2 gpm34515017,300-40 to 2103/41 1/23/8
    ThreadedFemale3/8
    ThreadedFemale6 9/16"3 3/4"4 1/4"5/8"2 1/16"2 3/4"4271K13000000
     

    Constant-Flow-Rate Gear Pumps without Motor for Oil

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps without Motor for Oil.
    A cast iron housing and steel gears allow these gear pumps to be used to dispense oil and fuel such as hydraulic oil and diesel fuel. Select your own motor to tailor them to your application. Use an air or electric motor with a coupling and belt/pulley drive. They produce a smooth flow of liquid for applications such as engine lubrication. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Required
    hp, hp
    Intake (NPT)
    Discharge (NPT)
    Overall
    Shaft
    Max. Flow Rate @
    25 psi, gpm
    Max. Flow
    Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    @ 25
    psi
    @ 100
    psi
    Pipe
    Size
    Connection
    Gender
    Pipe
    Size
    Connection
    Gender
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 1,725 rpm Maximum Motor Speed
    8.99 gpm46220020,000-20 to 4003/411/2
    ThreadedFemale1/2
    ThreadedFemale7 1/4"3 7/16"4 1/2"5/8"1 9/16"3"41915K72000000000
     

    Constant-Flow-Rate Gear Pumps for Oil

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps for Oil.
    A high-horsepower motor moves oil with a viscosity similar to SAE 60 motor oil. These gear pumps produce a smooth flow of liquid to lubricate equipment and blend oils. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Cannot Be Sold Outside North America—Products cannot be sold outside North America due to restrictions.
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow
    Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current
    Pipe
    Size
    Connection
    Gender
    Pipe
    Size
    Connection
    Gender
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    5 gpm577250880-20 to 2401/22 amp/1 amp1/2
    ThreadedFemale1/2
    ThreadedFemale21 5/8"6 7/8"8 1/2"Outside North America41505K41000000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    10 gpm577250880-20 to 24026.2 amp/3.1 amp3/4
    ThreadedFemale3/4
    ThreadedFemale24"6 7/8"8 1/2"Outside North America41505K4300000000
    20 gpm577250880-20 to 24026.2 amp/3.1 amp1
    ThreadedFemale1
    ThreadedFemale24 1/2"6 7/8"8 1/2"Outside North America41505K4500000000
    30 gpm577250880-20 to 24038.2 amp/4.1 amp1
    ThreadedFemale1
    ThreadedFemale25"6 7/8"8 1/2"Outside North America41505K4700000000
    40 gpm577250880-20 to 240513.8 amp/6.9 amp1 1/2
    ThreadedFemale1 1/2
    ThreadedFemale28 1/8"11 7/8"8 1/2"Outside North America41505K4900000000
     

    Constant-Flow-Rate Gear Pumps without Motor for Chemicals

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps without Motor for Chemicals.
    With a 316 stainless steel housing and stainless steel gears, these gear pumps are often used to dispense chemicals such as ethylene glycol, isopropyl alcohol, and nitric acid. Use an electric motor with a coupling and belt/pulley drive. They produce a smooth flow of liquid. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
    Required
    hp, hp
    Intake (NPT)
    Discharge (NPT)
    Overall
    Shaft
    Max. Flow Rate @
    25 psi, gpm
    Max. Flow
    Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    @ 25
    psi
    @ 100
    psi
    Pipe
    Size
    Connection
    Gender
    Pipe
    Size
    Connection
    Gender
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 1,800 rpm Maximum Motor Speed
    4.34 gpm346.315020,000-50 to 4501/43/41/2
    ThreadedFemale1/2
    ThreadedFemale6 1/4"3"3 3/4"1/2"1 1/4"2 5/8"43095K47000000000
    10.210 gpm346.315020,000-50 to 4501/21 1/23/4
    ThreadedFemale3/4
    ThreadedFemale7 1/2"3 3/8"4 3/8"5/8"1 3/4"3"43095K5200000000
     

    Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    12V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional2.2 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K43000000
     
    24V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional1.4 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K4400000
     

    Harsh Environment Self-Priming Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Harsh Environment Self-Priming Dewatering Pumps.
    This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
    Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Size
    Discharge Size
    Ht.
    Wd.
    Lg.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug with 8 ft. Long Cord
    5 4/5301/4"Not Rated12560 to 1801/44.21/2 NPT Female, 3/4 GHT Male1/2 NPT Female, 3/4 GHT Male9"5 5/8"7 3/8"4381K670000000
     

    Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K410000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K42000000
     

    High-Pressure Constant-Flow-Rate Rotary Vane Pumps without Motor for Water

    Image of Product. Front orientation. Rotary Vane Pumps. High-Pressure Constant-Flow-Rate Rotary Vane Pumps without Motor for Water.
    Commonly called rotary vane pumps, they have a built-in bypass relief valve to prevent pressure buildup. Attach an electric motor with a speed reducer or a belt pulley to alter the pump speed. Use a NEMA 56C frame motor. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They meet NSF/ANSI 61 safety standards for use with drinking water systems.
    303 Stainless Steel Housing—Pumps with a 303 stainless steel housing are more corrosion resistant than pumps with a brass housing.
    Intake
    Discharge
    Overall
    Shaft
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    For Motor
    Power Source
    Req. Power,
    hp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Lg.
    Wd.
    Dp.
    Ctr.-to-Base
    Lg.
    Each
    Brass Housing
    0.8554240Not RatedElectric1/43/8
    NPT
    Female3/8
    NPT
    Female7"7"6"7/16"1/4"3/8"3"82395K710000000
    1.8554240Not RatedElectric1/33/8
    NPT
    Female3/8
    NPT
    Female7"7"6"7/16"1/4"3/8"3"82395K72000000
    2.3554240Not RatedElectric1/23/8
    NPT
    Female3/8
    NPT
    Female7"7"6"7/16"1/4"3/8"3"82395K73000000
    4.3554240Not RatedElectric3/41/2
    NPT
    Female1/2
    NPT
    Female7"7"6"7/16"1/4"3/8"3"82395K74000000
    5.4554240Not RatedElectric11/2
    NPT
    Female1/2
    NPT
    Female7"7"6"7/16"1/4"3/8"3"82395K75000000
     
    303 Stainless Steel Housing
    2.3554240Not RatedElectric1/23/8
    NPT
    Female3/8
    NPT
    Female7"7"6"7/16"1/4"3/8"3"82395K76000000
    4.3554240Not RatedElectric3/41/2
    NPT
    Female1/2
    NPT
    Female7"7"6"7/16"1/4"3/8"3"82395K77000000
    5.4554240Not RatedElectric11/2
    NPT
    Female1/2
    NPT
    Female7"7"6"7/16"1/4"3/8"3"82395K78000000
     

    High-Pressure Constant-Flow-Rate Rotary Vane Pumps

    Image of Product. Front orientation. Rotary Vane Pumps. High-Pressure Constant-Flow-Rate Rotary Vane Pumps.
    Commonly called rotary vane pumps, these are designed to pump water at high pressures in low-flow applications. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. They have a built-in bypass relief valve to prevent pressure buildup. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Power,
    hp
    Current
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.8554240Not Rated30 to 1951/45 A3/8
    NPT
    Female3/8
    NPT
    Female12"6"6"82395K810000000
     
    120/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    1.8554240Not Rated30 to 1951/35.6/2.8 A3/8
    NPT
    Female3/8
    NPT
    Female12"6"6"82395K82000000
    2.3554240Not Rated30 to 1951/27.2/3.6 A3/8
    NPT
    Female3/8
    NPT
    Female12"6"6"82395K83000000
     

    Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water

    Image of Product. Front orientation. Diaphragm Pumps. Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water, Style A.
    Image of Product. Front orientation. Diaphragm Pumps. Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water, Style B.

    Style A

    Style B

    Mount these diaphragm pumps in any position, even upside down. Pumps have a fractional horsepower motor rated for intermittent use (return to room temperature before restarting). They are for use in low-flow spraying, draining, and washdown applications. They are self-priming, which means they create a suction force to draw liquid upward. Pumps can run dry and do not require an initial fill, so they’re a good choice for applications without a constant flow of liquid. Do not use with solids.
    Pressure Switch—Pumps with a pressure switch automatically shut off the pump at the maximum pressure.
    Battery Powered—Battery-operated pumps operate on a 12-volt battery. They are commonly used with agricultural sprayers and washers.
    Intake
    Discharge
    Overall
    Style
    Max. Flow
    Rate, gpm
    Flow Rate @ Pressure
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Current,
    amp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Self-Priming
    Ht., ft.
    Lg.
    Wd.
    Ht.
    Power
    Source
    Each
    120V AC, Single Phase—With Thermal Overload Protection and With Pressure Switch
     
    Hardwire
    A1.51.24 gpm @ 20 psi
    1.04 gpm @ 60 psi
    34615017013/8
    NPT
    Female3/8
    NPT
    Female89 3/8"3 3/8"4 1/8"Electric8080K420000000
     
    Plug In
    A1.41.15 gpm @ 20 psi
    0.84 gpm @ 60 psi
    138601300.573/8
    NPT
    Female3/8
    NPT
    Female87 5/8"3 3/8"4 1/4"Electric8080K31000000
    A1.61.32 gpm @ 20 psi
    1.07 gpm @ 60 psi
    2311001700.953/8
    NPT
    Female3/8
    NPT
    Female88 5/8"3 3/8"4"Electric8080K14000000
    A1.71.52 gpm @ 20 psi
    0.03 gpm @ 60 psi
    138601700.613/8
    NPT
    Female3/8
    NPT
    Female88 5/8"3 3/8"4"Electric8080K13000000
    A32.20 gpm @ 20 psi104451200.71/2
    NPSM
    Male1/2
    NPSM
    Male88 3/4"5"4 1/2"Electric8080K39000000
     
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    A3.42.30 gpm @ 20 psi924012011/2
    NPSM
    Male1/2
    NPSM
    Male87 5/8"5"4 3/8"Electric8080K19000000
     
    12V DC—With Thermal Overload Protection and With Pressure Switch
     
    Hardwire
    B5.34.30 gpm @ 20 psi
    3.40 gpm @ 60 psi
    12060140171/2
    NPSM
    Male1/2
    NPSM
    Male810"4 15/16"4"Battery3006N11000000
     
    12V DC—Without Thermal Overload Protection and With Pressure Switch
     
    Hardwire
    A1.81.45 gpm @ 20 psi
    1.22 gpm @ 60 psi
    2311001708.73/8
    NPT
    Female3/8
    NPT
    Female108 3/8"4"4 1/8"Battery1011N13000000
    A1.81.57 gpm @ 20 psi
    1.23 gpm @ 60 psi
    138601707.23/8
    NPT
    Female3/8
    NPT
    Female128 3/8"4"4 1/8"Battery1011N12000000
    A32.69 gpm @ 20 psi1155017081/2
    NPSM
    Male1/2
    NPSM
    Male88 5/8"5"4 1/2"Battery1011N14000000
    A3.52.56 gpm @ 20 psi115501309.91/2
    NPSM
    Male1/2
    NPSM
    Male98 5/8"5"4 1/2"Battery1011N16000000
     

    Air-Powered Constant-Flow-Rate Piston Pumps

    Image of Product. Front orientation. Piston Pumps. Air-Powered Constant-Flow-Rate Piston Pumps.
    Commonly called piston pumps, these are often used in high-pressure applications, such as hydrostatic testing of pipelines, tanks, and valves. Flow and outlet liquid pressure can be controlled by varying the air pressure. To calculate discharge liquid pressure, multiply the air pressure by the ratio shown in the table. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Flow
    Rate, gpm
    Air
    Pressure, psi
    Overall
    @ 0
    psi
    @ 3,000
    psi
    Max. ft. of
    Head, ft.
    Max. Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Consumption,
    scfm
    Air Connection
    (NPT)
    Intake Pipe
    Connection (NPT)
    Discharge Pipe
    Connection (NPT)
    Lg.
    Wd.
    Ht.
    Each
    86:1 Discharge Liquid to Inlet Air Pressure Ratio
    0.190.1728,76412,47010015145201/4 Female3/8 Female1/4 Female4 5/8"4"9"6770K43000000000
     
    28:1 Discharge Liquid to Inlet Air Pressure Ratio
    0.580.139,3654,06010015145201/4 Female3/8 Female1/4 Female4 5/8"4"9"6770K4100000000
     
    11:1 Discharge Liquid to Inlet Air Pressure Ratio
    4.763,6791,59510015145451/2 Female1 Female1/2 Female10 3/4"9 1/2"10 3/8"6770K2800000000
     

    Continuous-Duty Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water and Coolants

    Image of Product. Front orientation. Diaphragm Pumps. Continuous-Duty Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water and Coolants.
    Rated for continuous use, this diaphragm pump is often used to move caustics such as antifreeze and salt water. Mount it in any position, even upside down. It is typically used for low-flow spraying, draining, and washdown applications. The pump is self-priming, which means it creates a suction force to draw liquid upward. Pump can run dry and does not require an initial fill, so it’s a good choice for applications without a constant flow of liquid. Do not use with solids.
    Pressure Switch—Pumps with a pressure switch automatically shut off the pump at the maximum pressure.
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @
    Pressure
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Max. Temp.,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection and With Pressure Switch
     
    Plug In
    32.50 gpm @ 20 psi402501303/161.8Barbed
    Male1/2"Barbed
    Male1/2"10 7/8"5 3/8"5 5/8"2487K110000000
     

    Hydraulic Power Units

    Image of Product. Front orientation. Hydraulic Power Units.
    Create and supply hydraulic pressure. Choose a unit with a tank capacity about three times greater than your requirement to allow for heat dissipation. An inlet filter protects the pump from contamination.
    All units include an additional NPTF threaded inlet port. NPTF (Dryseal) threads are compatible with NPT threads. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Overall
    Inlet Connection —
    UN/UNF (SAE Straight)
    Inlet
    Connection — NPTF
    Outlet Connection —
    UN/UNF (SAE Straight)
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Power,
    hp
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Thread
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    Thread
    Size
    Dash Size
    Full Load Current
    @ Voltage
    Each
    240V AC/460V AC, Three Phase
    0.91,6001513"15"20 1/2"7/8"-14
    101/2
    087/8"-14
    101.5 amp @ 460V AC62915K31000000000
    1.32,3002513"15"24 1/2"7/8"-14
    101/2
    087/8"-14
    102.8 amp @ 460V AC62915K3200000000
    2.71,75031017 3/8"19"32 1/2"1 1/16"-12
    123/4
    121 1/16"-12
    124.4 amp @ 460V AC62915K3300000000
    3.62,05051017 3/4"19"29 3/4"1 1/16"-12
    123/4
    121 1/16"-12
    126.8 amp @ 460V AC62915K4400000000
    6.31,8007 1/22021 3/8"22 1/2"37 3/8"1 1/16"-12
    123/4
    121 1/16"-12
    129.5 amp @ 460V AC62915K3600000000
    8.61,700103021 3/8"22 1/2"42 1/4"1 1/16"-12
    123/4
    121 1/16"-12
    1212 amp @ 460V AC62915K4700000000
    10.42,100153023 3/8"22 1/2"44 1/8"1 1/16"-12
    123/4
    121 1/16"-12
    1218.1 amp @ 460V AC62915K48000000000
     

    Self-Priming Circulation Pumps without Motor for Oil

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Oil.
    Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Shaft
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Ht.
    Lg.
    Wd.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    11.55021Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT5/8"1 1/8"1 15/16"3 13/16"4 1/2"4 1/8"4281K240000000
    255026Not Rated50 to 1803/41 Female NPT1 Female NPT5/8"2 1/4"1 7/8"3 9/16"6 3/8"4 3/4"4281K26000000
     
    Repair Kits

    High-Pressure Constant-Flow-Rate Pumps without Motor for Pressure Washing

    Image of Product. Front orientation. Plunger Pumps. High-Pressure Constant-Flow-Rate Pumps without Motor for Pressure Washing.
    Also known as plunger pumps, these can provide pressures up to 3,000 psi. Use them for washdowns, drain jetting, and other pressurized water-spraying applications. Connect them directly to an electric motor to alter the pump speed. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Req. Power,
    hp
    For Motor Frame Size
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    For Shaft
    Dia.
    Each
    22,000-20 to 1602.7NEMA 56C3/8
    NPT
    Female3/8
    NPT
    Female8 1/4"8 5/8"6 1/2"5/8"82415K910000000
    33,000-20 to 1406 1/5NEMA 182TC, NEMA 184TC1/2
    NPT
    Female3/8
    NPT
    Female9 1/2"9 1/4"7 1/8"1 1/8"82415K92000000
    42,000-20 to 1405 1/2NEMA 182TC, NEMA 184TC1/2
    NPT
    Female3/8
    NPT
    Female9 1/2"9 1/4"7 1/8"1 1/8"82415K93000000

    Self-Priming Circulation Pumps without Motor for Water

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Water.
    Also known as flexible impeller pumps, these create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Overall
    Shaft
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Ht.
    Lg.
    Wd.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    136026Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT3 13/16"4 1/2"4 1/8"5/8"1 1/8"1 15/16"4281K210000000
    27.96026Not Rated50 to 1803/41 Female NPT1 Female NPT3 9/16"6 3/8"4 3/4"5/8"2 1/4"1 7/8"4281K23000000
     
    Repair Kits

    Slim-Shaft Hydraulic Power Units

    Image of Product. Front orientation. Hydraulic Power Units. Slim-Shaft Hydraulic Power Units.
    Image of Product. Front orientation. Hydraulic Tanks. Slim-Shaft Hydraulic Power Units.

    Replacement Hydraulic Tanks

    Mount these units to an existing machine or where space is limited. They create and supply hydraulic pressure where standard models won’t fit. Choose a unit with a tank capacity about three times greater than your requirement to allow for heat dissipation.
    Hydraulic Power Units
    Replacement
    Hydraulic Tanks
    Overall
    Inlet
    Connection — NPT
    Outlet
    Connection — NPT
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Power,
    hp
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Pipe
    Size
    Dash
    Size
    Pipe Size
    Dash
    Size
    Full Load Current
    @ Voltage
    Each
    Each
    120V AC/240V AC, Single Phase
    12,50022.336 1/8"8 1/8"8 5/8"1/4
    043/8
    0610 amp @ 240V AC3973K410000000003973K4150000000
    1.52,50022.334 7/8"8 1/8"8 5/8"1/4
    043/8
    0610 amp @ 240V AC3973K42000000003973K415000000
     

    Air to Hydraulic Power Units

    Image of Product. Front orientation. Air to Hydraulic Power Units.
    Power a hydraulic cylinder from your air system to avoid the setup, cost, and mess of hydraulic fluid. These converters give you more consistent power than using air power for an air cylinder. However, because air works at a lower pressure than hydraulic fluid, your hydraulic cylinder won’t move loads at its full force. Attach these converters to an air line with a speed controller and solenoid (not included).
    Note: These converters are not for use near fire.
    Oil
    Displacement, mm
    Overall,
    mm
    Inlet
    Connection—BSPT
    Outlet
    Connection—BSPT
    Drain
    Connection—BSPT
    Mounting
    Holes
    Max.
    Increments
    For Max. Hydraulic
    Cylinder Stroke Lg., mm
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Cap.,
    gal.
    Wd.
    Ht.
    Pipe
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    No.
    of
    Dia.,
    mm
    Features
    Each
    For 40 mm Bore Dia.
    5050603.31000.021072131/4
    061/4
    0647Drain Plug6476N11000000
    100501203.31000.031072631/4
    061/4
    0647Drain Plug6476N1200000
    150501803.31000.051073131/4
    061/4
    0647Drain Plug6476N1300000
    200502503.31000.071073631/4
    061/4
    0647Drain Plug6476N1400000
     
    For 63 mm Bore Dia.
    50501507.91000.041042283/8
    063/4
    121/4
    06411Drain Plug6476N1500000
    100503007.91000.081042783/8
    063/4
    121/4
    06411Drain Plug6476N16000000
    200506007.91000.161043783/8
    063/4
    121/4
    06411Drain Plug6476N17000000
    300508907.91000.241045033/8
    063/4
    121/4
    06411Drain Plug6476N18000000
     

    Drill-Operated Dewatering Pumps

    Image of ProductInUse. Front orientation. Dewatering Pumps. Drill-Operated Dewatering Pumps.
    Image of Product. Pump. Front orientation. Dewatering Pumps. Drill-Operated Dewatering Pumps.
    Image of Product. Pump with Intake and Discharge Tubes. Front orientation. Dewatering Pumps. Drill-Operated Dewatering Pumps.

    Pump

    Pump with Intake and Discharge Tubes

    Convenient to keep in your toolkit for on-site cleanup, these pumps attach to your drill for small liquid extraction jobs, as well as draining water from clogged sinks and emptying tanks. Pumps are self-priming, which means they create a suction force to draw liquid upward. Do not use with solids.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Intake
    Discharge
    Shaft
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Hose
    Size
    Thread
    Type
    Connection
    Gender
    Hose
    Size
    Thread
    Type
    Connection
    Gender
    Motor Speed,
    rpm
    Dia.
    Lg.
    Ht.
    Wd.
    Lg.
    Includes
    Each
    3 3/490140 to 1103/4GHT
    ThreadedMale3/4GHT
    ThreadedMale1,2001/4"3/4"3"4 1/2"3"99705K21000000
    3 3/490140 to 1103/4GHT
    ThreadedMale3/4GHT
    ThreadedMale1,2001/4"3/4"3"4 1/2"3"30" Slip-On Intake Tube, 34" Discharge Tube with 3/4" Male GHT Connection99705K2500000
     
    back to top