    About Electrical Enclosures
    industrial info icon

    Select the right electrical enclosure for your environment and the accessories you'll need to get it mounted and connected.

    Hazardous Location Push-Button Enclosures

    Image of Product. Front orientation. Electrical Enclosures. Hazardous Location Push-Button Enclosures.
    Safely house control switches, emergency stops, and indicating lights in areas with flammable gases, combustible dust, and ignitable fibers. These NEC-rated enclosures are often used to protect your people and parts from explosive risks in plants that handle or make fuel, bulk powders, and chemicals. Plus, they lock out water to keep your electrical components dry.
    Lift-Off Cover—The removable, screw-secured cover is best for full access during setup or service, but not for frequent entry.
    Aluminum—Best for housing sensors and other sensitive electronics where interference is a concern, these enclosures block wireless and radio signals. They’re also a rust-resistant alternative to stainless steel in wet areas.
    No. of
    Connection
    For 19 mm Push
    Buttons
    Holes
    Columns
    Rows
    Wd.
    Ht.
    Dp.
    Cover Closure
    Method
    With
    Knockouts
    Enclosure Rating
    Hazardous Location Rating
    External
    Mount Type
    Color
    Pipe
    Size
    Thread
    Type
    Each
    Lift-Off Cover
     
    Aluminum
    1114 1/2"4 1/2"4 1/2"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray3/4
    NPT
    5975N110000000
    2124 1/2"7"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray3/4
    NPT
    5975N12000000
    3134 1/2"8"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray3/4
    NPT
    5975N13000000
    4144 1/2"10"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray1
    NPT
    5975N14000000
    5154 1/2"12"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray1 1/4
    NPT
    5975N15000000
    6164 1/2"14"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray1 1/4
    NPT
    5975N16000000
    7174 1/2"16"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray1 1/4
    NPT
    5975N1700000000
     

    Hazardous Location Enclosures

    Image of Product. Front orientation. Electrical Enclosures. Hazardous Location Enclosures, Lift-Off Cover.
    Image of Product. Front orientation. Electrical Enclosures. Hazardous Location Enclosures, Hinged Cover.

    Lift-Off Cover

    Hinged Cover

    Protect your people and parts from explosive risks in areas with flammable gases, combustible dust, and ignitable fibers. These NEC-rated enclosures are often used to shield motor controls, power supplies, and wiring in plants that handle or make fuel, bulk powders, and chemicals. Plus, they lock out water to keep your electrical components dry.
    Lift-Off Cover—The removable, screw-secured cover is best for full access during setup or service, but not for frequent entry.
    Hinged Cover—The cover swings open for fast, frequent access and remains attached to prevent drops or loss.
    Aluminum—Best for housing sensors and other sensitive electronics where interference is a concern, these enclosures block wireless and radio signals. They’re also a rust-resistant alternative to stainless steel in wet areas.
    Enclosures
    Panels
    Wd.
    Ht.
    Dp.
    Cover Closure
    Method
    With
    Knockouts
    Enclosure Rating
    Hazardous Location Rating
    External
    Mount Type
    Each
    Each
    Lift-Off Cover
     
    Aluminum
    10"10"6"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K210000000007624K31000000
    12"12"8"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K22000000007624K32000000
    14"12"8 1/2"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K23000000007624K33000000
     
    Hinged Cover
     
    Aluminum
    17"17"9"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K24000000007624K34000000
    17"17"11"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K25000000007624K34000000
     

    Hazardous Location Enclosed Motor Switches

    Image of Product. Front orientation. Motor Switches. Hazardous Location Enclosed Motor Switches.
    Safely turn motors on and off near ignitable gases and dust—the housing on these switches seals in anything that could ignite flammable material. Made from aluminum, the housing is lightweight and durable. It guards against water, oil, and other materials that could cause damage. Even in harsh conditions, there’s no need to mount these switches inside an electrical panel.
    You need to grip and twist the lever to actuate these switches, so they won’t accidentally turn on or off if something bumps into them. In addition to starting and stopping motors, they work with other circuits, such as lighting and electric heat circuits. They don’t provide overload protection.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    Wire
    Connection
    Environment
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    2Single (3 hp @ 240V AC)2 Off
    DPST-NO
    30600Painted Aluminum6.5"3"Screw TerminalHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    UL Listed, C-UL Listed, CSA Certified
    7657K320000000
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    30600Painted Aluminum6.5"3"Screw TerminalHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    UL Listed, C-UL Listed, CSA Certified
    7657K22000000
     

    Hazardous Location Enclosed Disconnect Switches

    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    Powder-Coated Aluminum Housing—Made from aluminum, these switches also resist corrosion in wet or oily areas.
    Lockout—Switches have a lockout, so you can secure them in the off position with a padlock (not included).
    Hazardous Location Rating—They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Hazardous Location Rating
    Enclosure Rating
    Certification
    Each
    Gray Powder-Coated Aluminum Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    A306003PST
    Three (30 hp @ 600V AC)8 1/16"5 3/4"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N11000000000
     
    Gray Powder-Coated Aluminum Housing with Yellow Actuator
     
    3 Circuits Controlled with Lockout
    B606003PST
    Three (40 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1200000000
    B1006003PST
    Three (50 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1300000000
     