Filter by
Environment
System of Measurement
Heat Output
Current
Maximum Space Heated @ Temperature Change
Material
Electrical Connection
Maximum Temperature
Power Source
Certification
Export Control Classification Number (ECCN)
Electrical Connection Type
DFARS Specialty Metals
About Heaters
Choose the right heater type and range to warm spaces or people and objects efficiently.
Hazardous Location Wall-Mount Small-Space Electric Heaters
With Thermostat
Overall | Housing | Mounting | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, BTU/hr | Max. Space Heated @ Temp. Change | Airflow | Wattage, W | Current, amp | Ht. | Wd. | Dp. | Material | Color | Includes | Environment | Hazardous Location Rating | Certification | Fasteners Included | Hole Dia. | Each | |||
120V AC, Single Phase—Wire Leads | |||||||||||||||||||
50° F to 90° F Temperature Setting | |||||||||||||||||||
| 6,100 | 810 cu. ft. @ 10° F 400 cu. ft. @ 20° F 270 cu. ft. @ 30° F 200 cu. ft. @ 40° F | Not Rated | 1,800 | 15 | 18" | 40" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K61 | 000000000 | ||
208V AC, Single Phase—Wire Leads | |||||||||||||||||||
50° F to 90° F Temperature Setting | |||||||||||||||||||
| 6,100 | 810 cu. ft. @ 10° F 400 cu. ft. @ 20° F 270 cu. ft. @ 30° F 200 cu. ft. @ 40° F | Not Rated | 1,800 | 8.7 | 18" | 40" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K62 | 00000000 | ||
| 12,200 | 1,620 cu. ft. @ 10° F 810 cu. ft. @ 20° F 540 cu. ft. @ 30° F 400 cu. ft. @ 40° F | Not Rated | 3,600 | 17.3 | 18" | 40" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K64 | 00000000 | ||
| 25,900 | 3,450 cu. ft. @ 10° F 1,720 cu. ft. @ 20° F 1,150 cu. ft. @ 30° F 860 cu. ft. @ 40° F | Not Rated | 7,600 | 36.5 | 18" | 66" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K67 | 00000000 | ||
240V AC, Single Phase—Wire Leads | |||||||||||||||||||
50° F to 90° F Temperature Setting | |||||||||||||||||||
| 6,100 | 810 cu. ft. @ 10° F 400 cu. ft. @ 20° F 270 cu. ft. @ 30° F 200 cu. ft. @ 40° F | Not Rated | 1,800 | 7.5 | 18" | 40" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K63 | 00000000 | ||
| 12,200 | 1,620 cu. ft. @ 10° F 810 cu. ft. @ 20° F 540 cu. ft. @ 30° F 400 cu. ft. @ 40° F | Not Rated | 3,600 | 15 | 18" | 40" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K65 | 00000000 | ||
| 25,900 | 3,450 cu. ft. @ 10° F 1,720 cu. ft. @ 20° F 1,150 cu. ft. @ 30° F 860 cu. ft. @ 40° F | Not Rated | 7,600 | 31.7 | 18" | 66" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K68 | 00000000 | ||
480V AC, Single Phase—Wire Leads | |||||||||||||||||||
50° F to 90° F Temperature Setting | |||||||||||||||||||
| 12,200 | 1,620 cu. ft. @ 10° F 810 cu. ft. @ 20° F 540 cu. ft. @ 30° F 400 cu. ft. @ 40° F | Not Rated | 3,600 | 7.5 | 18" | 40" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K66 | 00000000 | ||
| 25,900 | 3,450 cu. ft. @ 10° F 1,720 cu. ft. @ 20° F 1,150 cu. ft. @ 30° F 860 cu. ft. @ 40° F | Not Rated | 7,600 | 15.8 | 18" | 64" | 9" | Painted Steel | Gray | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D | ETL Listed, C-ETL Listed | No | 3/8" | 1752K69 | 00000000 | ||
Horizontal-Flow Hazardous Location Large-Space Steam and Water Heaters
Inlet | Outlet | Steam | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, BTU/hr | Max. Space Heated @ Temp. Change | Airflow, ft³/min | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Temp., ° F | Current, amp | Ht. | Wd. | Dp. | Housing Material | Each | |||
120V AC, Single Phase—Wire Leads | |||||||||||||||||||
Ceiling Mount | |||||||||||||||||||
| 24,000 | 3,200 cu. ft. @ 10° F 1,600 cu. ft. @ 20° F 1,060 cu. ft. @ 30° F 800 cu. ft. @ 40° F | 370 | 3/4 | NPT | Female | 3/4 | NPT | Female | 85 | 325 | 3.1 | 13" | 13" | 19" | Steel | 1836K91 | 000000000 | ||
| 47,000 | 6,260 cu. ft. @ 10° F 3,130 cu. ft. @ 20° F 2,080 cu. ft. @ 30° F 1,560 cu. ft. @ 40° F | 730 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325 | 3.1 | 17" | 18" | 21" | Steel | 1836K92 | 00000000 | ||
| 63,000 | 8,400 cu. ft. @ 10° F 4,200 cu. ft. @ 20° F 2,800 cu. ft. @ 30° F 2,100 cu. ft. @ 40° F | 1,120 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325 | 3.1 | 21" | 22" | 21" | Steel | 1836K93 | 00000000 | ||
| 86,000 | 11,460 cu. ft. @ 10° F 5,730 cu. ft. @ 20° F 3,820 cu. ft. @ 30° F 2,860 cu. ft. @ 40° F | 1,340 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325 | 3.1 | 21" | 22" | 21" | Steel | 1836K94 | 00000000 | ||
| 121,000 | 16,130 cu. ft. @ 10° F 8,060 cu. ft. @ 20° F 5,370 cu. ft. @ 30° F 4,030 cu. ft. @ 40° F | 1,775 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325 | 4.1 | 25" | 26" | 23" | Steel | 1836K95 | 00000000 | ||
| 165,000 | 22,000 cu. ft. @ 10° F 11,000 cu. ft. @ 20° F 7,330 cu. ft. @ 30° F 5,500 cu. ft. @ 40° F | 3,240 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325 | 7.2 | 31" | 31" | 25" | Steel | 1836K96 | 00000000 | ||
| 193,000 | 25,730 cu. ft. @ 10° F 12,860 cu. ft. @ 20° F 8,570 cu. ft. @ 30° F 6,430 cu. ft. @ 40° F | 2,900 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325 | 7.2 | 31" | 31" | 25" | Steel | 1836K97 | 00000000 | ||
| 258,000 | 34,400 cu. ft. @ 10° F 17,200 cu. ft. @ 20° F 11,460 cu. ft. @ 30° F 8,600 cu. ft. @ 40° F | 4,560 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325 | 5.8 | 39" | 39" | 28" | Steel | 1836K98 | 00000000 | ||
| 340,000 | 45,330 cu. ft. @ 10° F 22,660 cu. ft. @ 20° F 15,110 cu. ft. @ 30° F 11,330 cu. ft. @ 40° F | 5,130 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325 | 5.8 | 39" | 45" | 28" | Steel | 1836K99 | 00000000 | ||
Hazardous Location Wall-Mount Large-Space Electric Heaters
With Thermostat
Overall | Mounting | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, BTU/hr | Max. Space Heated @ Temp. Change | Airflow, ft³/min | Wattage, W | Current, amp | Ht. | Wd. | Dp. | Housing Material | Includes | Environment | Hazardous Location Rating | Certification | Fasteners Included | Hole Dia. | Each | |||
480V AC, Three Phase—Wire Leads | ||||||||||||||||||
50° F to 90° F Temperature Setting | ||||||||||||||||||
| 25,600 | 3,410 cu. ft. @ 10° F 1,700 cu. ft. @ 20° F 1,130 cu. ft. @ 30° F 850 cu. ft. @ 40° F | 580 | 7,500 | 9.7 | 18" | 23" | 20" | Steel | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G | ETL Listed, C-ETL Listed | No | 1/2" | 1799K26 | 000000000 | ||
| 34,100 | 4,540 cu. ft. @ 10° F 2,270 cu. ft. @ 20° F 1,510 cu. ft. @ 30° F 1,130 cu. ft. @ 40° F | 1,500 | 10,000 | 12.7 | 21" | 27" | 21" | Steel | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G | ETL Listed, C-ETL Listed | No | 1/2" | 1799K28 | 00000000 | ||
| 85,400 | 11,380 cu. ft. @ 10° F 5,690 cu. ft. @ 20° F 3,790 cu. ft. @ 30° F 2,840 cu. ft. @ 40° F | 2,450 | 25,000 | 31.1 | 25" | 31" | 23" | Steel | Mounting Bracket | Hazardous | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G | ETL Listed, C-ETL Listed | No | 1/2" | 1799K33 | 000000000 | ||
Horizontal-Flow Hazardous Location Large-Space Steam Heaters
Inlet | Outlet | Steam | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, BTU/hr | Max. Space Heated @ Temp. Change | Airflow, ft³/min | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Temp., ° F | Current, amp | Ht. | Wd. | Dp. | Housing Material | Each | |||
120V AC/240V AC, Single Phase—Wire Leads | |||||||||||||||||||
Ceiling Mount | |||||||||||||||||||
| 70,600 | 9,410 cu. ft. @ 10° F 4,700 cu. ft. @ 20° F 3,130 cu. ft. @ 30° F 2,350 cu. ft. @ 40° F | 1,265 | 1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 200 | 600 | 2.5 | 18" | 16" | 21" | Steel | 1732K13 | 000000000 | ||
| 106,000 | 14,130 cu. ft. @ 10° F 7,060 cu. ft. @ 20° F 4,710 cu. ft. @ 30° F 3,530 cu. ft. @ 40° F | 1,940 | 2 | NPT | Female | 2 | NPT | Female | 200 | 600 | 2.5 | 21" | 19" | 21" | Steel | 1732K15 | 00000000 | ||
| 157,300 | 20,970 cu. ft. @ 10° F 10,480 cu. ft. @ 20° F 6,990 cu. ft. @ 30° F 5,240 cu. ft. @ 40° F | 2,890 | 2 | NPT | Female | 2 | NPT | Female | 200 | 600 | 3.7 | 25" | 22" | 25" | Steel | 1732K18 | 00000000 | ||
| 267,800 | 35,700 cu. ft. @ 10° F 17,850 cu. ft. @ 20° F 11,900 cu. ft. @ 30° F 8,920 cu. ft. @ 40° F | 4,770 | 2 1/2 | NPT | Female | 2 1/2 | NPT | Female | 200 | 600 | 4 | 33" | 29" | 25" | Steel | 1732K19 | 00000000 | ||
Vertical-Flow Hazardous Location Large-Space Steam and Water Heaters
Inlet | Outlet | Steam | Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, BTU/hr | Max. Space Heated @ Temp. Change | Airflow, ft³/min | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Temp., ° F | Current, amp | Ht. | Dia. | Housing Material | Each | |||
120V AC, Single Phase—Wire Leads | ||||||||||||||||||
Ceiling Mount | ||||||||||||||||||
| 59,000 | 7,860 cu. ft. @ 10° F 3,930 cu. ft. @ 20° F 2,620 cu. ft. @ 30° F 1,960 cu. ft. @ 40° F | 1,155 | 1 1/4 | NPT | Male | 1 1/4 | NPT | Male | 85 | 325 | 4.1 | 10" | 25" | Steel | 1880K71 | 000000000 | ||
| 95,000 | 12,660 cu. ft. @ 10° F 6,330 cu. ft. @ 20° F 4,220 cu. ft. @ 30° F 3,160 cu. ft. @ 40° F | 1,665 | 1 1/4 | NPT | Male | 1 1/4 | NPT | Male | 85 | 325 | 4.1 | 11" | 25" | Steel | 1880K72 | 00000000 | ||
| 139,000 | 18,530 cu. ft. @ 10° F 9,260 cu. ft. @ 20° F 6,170 cu. ft. @ 30° F 4,630 cu. ft. @ 40° F | 2,660 | 1 1/2 | NPT | Male | 1 | NPT | Male | 85 | 325 | 4.1 | 10" | 35" | Steel | 1880K73 | 00000000 | ||
| 161,000 | 21,460 cu. ft. @ 10° F 10,730 cu. ft. @ 20° F 7,150 cu. ft. @ 30° F 5,360 cu. ft. @ 40° F | 2,940 | 1 1/2 | NPT | Male | 1 | NPT | Male | 85 | 325 | 7.2 | 18" | 35" | Steel | 1880K74 | 00000000 | ||
| 193,000 | 25,730 cu. ft. @ 10° F 12,860 cu. ft. @ 20° F 8,570 cu. ft. @ 30° F 6,430 cu. ft. @ 40° F | 3,500 | 1 1/2 | NPT | Male | 1 | NPT | Male | 85 | 325 | 7.2 | 18" | 35" | Steel | 1880K75 | 00000000 | ||
| 279,000 | 37,200 cu. ft. @ 10° F 18,600 cu. ft. @ 20° F 12,400 cu. ft. @ 30° F 9,300 cu. ft. @ 40° F | 5,460 | 2 | NPT | Male | 1 1/4 | NPT | Male | 85 | 325 | 5.8 | 18" | 35" | Steel | 1880K77 | 00000000 | ||
Hazardous Location Adhesive-Mount Heat Sheets
Rectangle
Overall | Adhesive Ready | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Wd. | Thk. | Wattage, W | Voltage, V AC | Electrical Phase | Current, amp | Max. Heat Output, ° F | Material | Environment Temp. Range, ° F | Wire Lead Lg. | For Surface Material | Hazardous Location Rating | NEC Hazardous Location Temp. Classification | Each | |||
2.5 W/in² Watt Density | |||||||||||||||||
| 12" | 6" | 3/16" | 180 | 120 | Single | 1.5 | 290 | Silicone Rubber | -60 to 400 | 12" | Metal | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G IEC Zone 2 Groups IIB, IIA IEC Zone 22 Groups IIIB, IIIA ATEX II 3 D Ex Tc IIIB T200° C Dc ATEX II 3 G Ex nC IIB T3 Gc | T3 (392° F) | 6496N11 | 0000000 | ||
| 12" | 12" | 3/16" | 360 | 120 | Single | 3 | 290 | Silicone Rubber | -60 to 400 | 12" | Metal | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G IEC Zone 2 Groups IIB, IIA IEC Zone 22 Groups IIIB, IIIA ATEX II 3 D Ex Tc IIIB T200° C Dc ATEX II 3 G Ex nC IIB T3 Gc | T3 (392° F) | 6496N13 | 000000 | ||
| 24" | 6" | 3/16" | 360 | 120 | Single | 3 | 290 | Silicone Rubber | -60 to 400 | 12" | Metal | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G IEC Zone 2 Groups IIB, IIA IEC Zone 22 Groups IIIB, IIIA ATEX II 3 D Ex Tc IIIB T200° C Dc ATEX II 3 G Ex nC IIB T3 Gc | T3 (392° F) | 6496N12 | 000000 | ||
| 24" | 12" | 3/16" | 720 | 120 | Single | 6 | 290 | Silicone Rubber | -60 to 400 | 12" | Metal | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G IEC Zone 2 Groups IIB, IIA IEC Zone 22 Groups IIIB, IIIA ATEX II 3 D Ex Tc IIIB T200° C Dc ATEX II 3 G Ex nC IIB T3 Gc | T3 (392° F) | 6496N14 | 000000 | ||
Cut-to-Length Constant-Wattage Heating Tape for Pipes and Tubes
Per Ft. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Watt Density, W/ft | Wd. | Thk. | Max. Lg., ft. | Environment Temp. Range, ° F | Electrical Connection Type | Cable Cover Material | For Surface Material | Hazardous Location Rating | For Use Outdoors | 1-99 | 100-Up | |||
150° F Maximum Heat Output | ||||||||||||||
120V AC, Single Phase | ||||||||||||||
| 2.5 | 1/2" | 11/32" | 500 | -40 to 400 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K12 | 000000 | 000000 | ||
| 5 | 1/2" | 11/32" | 500 | -40 to 400 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K13 | 00000 | 00000 | ||
| 8 | 1/2" | 11/32" | 500 | -40 to 400 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K14 | 00000 | 00000 | ||
| 10 | 1/2" | 11/32" | 500 | -40 to 400 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K15 | 00000 | 00000 | ||
240V AC, Single Phase | ||||||||||||||
| 5 | 1/2" | 11/32" | 500 | -40 to 400 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K16 | 00000 | 00000 | ||
480V AC, Single Phase | ||||||||||||||
| 10 | 1/2" | 11/32" | 500 | -40 to 400 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K17 | 00000 | 00000 | ||
300° F Maximum Heat Output | ||||||||||||||
120V AC, Single Phase | ||||||||||||||
| 10 | 1/2" | 11/32" | 500 | -60 to 500 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K23 | 00000 | 00000 | ||
| 15 | 1/2" | 11/32" | 500 | -60 to 500 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K24 | 00000 | 00000 | ||
240V AC, Single Phase | ||||||||||||||
| 10 | 1/2" | 11/32" | 500 | -60 to 500 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K25 | 00000 | 00000 | ||
| 15 | 1/2" | 11/32" | 500 | -60 to 500 | Hardwire | Plastic | Metal | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 35535K26 | 00000 | 00000 | ||
480V AC, Single Phase | ||||||||||||||
| 10 | 1/2" | 11/32" | 500 | -60 to 500 | Hardwire | Plastic | Metal | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | No | 35535K27 | 00000 | 00000 | ||
| 15 | 1/2" | 11/32" | 500 | -60 to 500 | Hardwire | Plastic | Metal | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | No | 35535K28 | 00000 | 00000 | ||
| 20 | 1/2" | 11/32" | 500 | -60 to 500 | Hardwire | Plastic | Metal | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | No | 35535K29 | 00000 | 00000 | ||
Hazardous Location Thermally Insulating Wraparound Heaters for Drums and Totes
For Container | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dia. | Wd. | Dp. | Ht. | Wattage, W | Watt Density, W/in² | Voltage, V AC | Current, amp | Max. Heat Output, ° F | For Surface Material | Material | Insulation Material | Hazardous Location Rating | Each | |||
Nonadjustable Thermostat | ||||||||||||||||
For 55 gal. Containers | ||||||||||||||||
| 23 5/16" | — | — | 34" | 800 | 0.3 | 120 | 6.6 | 100 | For Metal, Plastic, or Fiberglass | Vinyl Plastic | Foam | NEC Class I Division 2 Groups A, B, C, D | 7039N12 | 000000000 | ||
| 23 5/16" | — | — | 34" | 1,200 | 0.5 | 120 | 10 | 140 | For Metal, Plastic, or Fiberglass | Nylon | Fiberglass | NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEC Zone 2 Groups IIC, IIB, IIA | 7039N11 | 00000000 | ||
For 275 gal. Containers | ||||||||||||||||
| — | 40" | 48" | 46" | 1,440 | 0.17 | 120 | 12 | 120 | For Metal, Plastic, or Fiberglass | Vinyl Plastic | Foam | NEC Class I Division 2 Groups A, B, C, D | 7039N13 | 00000000 | ||
For 330 gal. Containers | ||||||||||||||||
| — | 40" | 48" | 53" | 1,440 | 0.15 | 120 | 12 | 120 | For Metal, Plastic, or Fiberglass | Vinyl Plastic | Foam | NEC Class I Division 2 Groups A, B, C, D | 7039N14 | 00000000 | ||
Cut-to-Length Self-Regulating Heating Tape for Pipes and Tubes
Plastic Cable Cover
Watt Density, W/ft | Per Ft. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@50°F | @100°F | @150°F | Wd. | Thk. | Max. Lg., ft. | Environment Temp. Range, ° F | Electrical Connection Type | For Surface Material | Hazardous Location Rating | For Use Outdoors | 1-99 | 100-Up | |||
150° F Maximum Heat Output | |||||||||||||||
120V AC, Single Phase | |||||||||||||||
| 3 | 1.5 | 0.2 | 9/16" | 1/4" | 500 | -60 to 185 | Hardwire | Metal, Plastic | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 3597K19 | 000000 | 00000 | ||
| 5 | 2.5 | 1 | 9/16" | 1/4" | 500 | -60 to 185 | Hardwire | Metal, Plastic | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 3597K21 | 00000 | 0000 | ||
| 8 | 4.5 | 1.8 | 9/16" | 1/4" | 500 | -60 to 185 | Hardwire | Metal, Plastic | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 3597K22 | 00000 | 0000 | ||
| 10 | 5.7 | 2.1 | 9/16" | 1/4" | 500 | -60 to 185 | Hardwire | Metal, Plastic | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 3597K23 | 00000 | 0000 | ||
240V AC, Single Phase | |||||||||||||||
| 8 | 4.5 | 1.8 | 9/16" | 1/4" | 500 | -60 to 185 | Hardwire | Metal, Plastic | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 3597K24 | 00000 | 0000 | ||
| 10 | 5.7 | 2.1 | 9/16" | 1/4" | 500 | -60 to 185 | Hardwire | Metal, Plastic | Ex E II NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 AEx E II | No | 3597K26 | 00000 | 0000 | ||
250° F Maximum Heat Output | |||||||||||||||
120V AC, Single Phase | |||||||||||||||
| 9 | — | 6 | 7/16" | 1/4" | 500 | -75 to 400 | Hardwire | Metal, Plastic | Ex Eb IIC Ex Tb IIIC NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA AEx Eb IIC Gb AEx Tb IIIC Db | No | 36005K15 | 00000 | 00000 | ||
| 12 | — | 8.5 | 7/16" | 1/4" | 500 | -75 to 400 | Hardwire | Metal, Plastic | Ex Eb IIC Ex Tb IIIC NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA AEx Eb IIC Gb AEx Tb IIIC Db | No | 36005K16 | 00000 | 00000 | ||
| 15 | — | 11 | 7/16" | 1/4" | 500 | -75 to 400 | Hardwire | Metal, Plastic | Ex Eb IIC Ex Tb IIIC NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA AEx Eb IIC Gb AEx Tb IIIC Db | No | 36005K17 | 00000 | 00000 | ||
| 20 | — | 15 | 7/16" | 1/4" | 500 | -75 to 400 | Hardwire | Metal, Plastic | Ex Eb IIC Ex Tb IIIC NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA AEx Eb IIC Gb AEx Tb IIIC Db | No | 36005K18 | 00000 | 00000 | ||
240V AC, Single Phase | |||||||||||||||
| 12 | — | 8.5 | 7/16" | 1/4" | 500 | -75 to 400 | Hardwire | Metal, Plastic | Ex Eb IIC Ex Tb IIIC NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA AEx Eb IIC Gb AEx Tb IIIC Db | No | 36005K19 | 00000 | 00000 | ||
| 20 | — | 15 | 7/16" | 1/4" | 500 | -75 to 400 | Hardwire | Metal, Plastic | Ex Eb IIC Ex Tb IIIC NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA AEx Eb IIC Gb AEx Tb IIIC Db | No | 36005K25 | 00000 | 00000 | ||
Hazardous Location Threaded Thermocouple Probes for Liquids and Gases
Probe | Probe Connection | Conduit Connection | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Max. Temp., ° F | Accuracy @ Temperature | Overall Lg. | Sensor Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Certification | Hazardous Location Rating | Enclosure Rating | Each | |||
446 Stainless Steel Probe | ||||||||||||||||||
Type J Thermocouple | ||||||||||||||||||
| 1" to 3" | 1/2" | 1,400 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 10 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K63 | 0000000 | ||
| 4" to 6" | 1/2" | 1,400 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 13 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K65 | 000000 | ||
| 8" to 10" | 1/2" | 1,400 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 17 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K43 | 000000 | ||
| 10" to 12" | 1/2" | 1,400 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 19 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K61 | 000000 | ||
| 14" to 16" | 1/2" | 1,400 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 23 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K42 | 000000 | ||
| 20" to 22" | 1/2" | 1,400 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 29 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K45 | 000000 | ||
Type K Thermocouple | ||||||||||||||||||
| 1" to 3" | 1/2" | 2,100 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 10 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K64 | 000000 | ||
| 4" to 6" | 1/2" | 2,100 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 13 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K66 | 000000 | ||
| 8" to 10" | 1/2" | 2,100 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 17 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K53 | 000000 | ||
| 10" to 12" | 1/2" | 2,100 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 19 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K62 | 000000 | ||
| 14" to 16" | 1/2" | 2,100 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 23 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K54 | 000000 | ||
| 20" to 22" | 1/2" | 2,100 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 29 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4 | 3864K55 | 000000 | ||
Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases
Probe | Probe Connection | Conduit Connection | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Response Time, sec. | Temp. Range, ° F | Accuracy @ Temperature | Overall Lg. | Sensor Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Output Analog Signal | Voltage Range, V DC | Enclosure Rating | Hazardous Location Rating | Each | |||
Type J Thermocouple | ||||||||||||||||||||
316 Stainless Steel Probe | ||||||||||||||||||||
| 2 1/2" | 1/4" | 5 | 0 to 500 | Not Rated Below 32° F ±4° F Between 32° F to 500° F | 8 1/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N113 | 0000000 | ||
| 4" | 1/4" | 5 | 0 to 500 | Not Rated Below 32° F ±4° F Between 32° F to 500° F | 9 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N118 | 000000 | ||
| 6" | 1/4" | 5 | 0 to 500 | Not Rated Below 32° F ±4° F Between 32° F to 500° F | 11 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N124 | 000000 | ||
| 9" | 1/4" | 5 | 0 to 500 | Not Rated Below 32° F ±4° F Between 32° F to 500° F | 14 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N129 | 000000 | ||
| 12" | 1/4" | 5 | 0 to 500 | Not Rated Below 32° F ±4° F Between 32° F to 500° F | 17 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N135 | 000000 | ||
Type K Thermocouple | ||||||||||||||||||||
Nickel Probe | ||||||||||||||||||||
| 2 1/2" | 1/4" | 5 | 0 to 2,150 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 8 1/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N143 | 000000 | ||
| 4" | 1/4" | 5 | 0 to 2,150 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 9 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N148 | 000000 | ||
| 6" | 1/4" | 5 | 0 to 2,150 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 11 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N154 | 000000 | ||
| 9" | 1/4" | 5 | 0 to 2,150 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 14 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N159 | 000000 | ||
316 Stainless Steel Probe | ||||||||||||||||||||
| 12" | 1/4" | 5 | 0 to 2,150 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | 17 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N165 | 000000 | ||
Type T Thermocouple | ||||||||||||||||||||
316 Stainless Steel Probe | ||||||||||||||||||||
| 2 1/2" | 1/4" | 5 | -328 to 100 | Not Rated Below 32° F ±1.8° F Between 32° F to 100° F | 8 1/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N167 | 000000 | ||
| 4" | 1/4" | 5 | -328 to 100 | Not Rated Below 32° F ±1.8° F Between 32° F to 100° F | 9 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N173 | 000000 | ||
| 6" | 1/4" | 5 | -328 to 100 | Not Rated Below 32° F ±1.8° F Between 32° F to 100° F | 11 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N178 | 000000 | ||
| 9" | 1/4" | 5 | -328 to 100 | Not Rated Below 32° F ±1.8° F Between 32° F to 100° F | 14 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N184 | 000000 | ||
| 12" | 1/4" | 5 | -328 to 100 | Not Rated Below 32° F ±1.8° F Between 32° F to 100° F | 17 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4 mA to 20 mA | 8 to 35 | IP68, NEMA 4X | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 4635N189 | 000000 | ||
Hazardous Location Threaded Thermocouple Probes with Thermowell for Liquids and Gases
Probes 316 Stainless Steel Thermowell Ceramic Probe
![]() | ![]() |
Probe | Thermowell Connection | Conduit Connection | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Movement | Response Time | Max. Temp., ° F | Accuracy @ Temperature | Insulation | Overall Lg. | Sensor Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Certification | Hazardous Location Rating | Enclosure Rating | For Max. Wire Ga. | Each | |||
Type J | ||||||||||||||||||||||
Screw Terminal | ||||||||||||||||||||||
| 4 1/2" | 1/2" | Fixed | Not Rated | 1,400 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Insulated | 13 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T771 | 0000000 | ||
| 7 1/2" | 1/2" | Fixed | Not Rated | 1,400 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Insulated | 16 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T781 | 000000 | ||
| 10 1/2" | 1/2" | Fixed | Not Rated | 1,400 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Insulated | 19 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T791 | 000000 | ||
Type K | ||||||||||||||||||||||
Screw Terminal | ||||||||||||||||||||||
| 4 1/2" | 1/2" | Fixed | Not Rated | 1,650 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Insulated | 13 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T774 | 000000 | ||
| 7 1/2" | 1/2" | Fixed | Not Rated | 1,650 | ±0.75% Above 533° F ±2.7° F Between 32° F to 533° F | Insulated | 16 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T784 | 000000 | ||
| 10 1/2" | 1/2" | Fixed | Not Rated | 1,650 | ±0.75% Above 533° F ±2.7° F Between 32° F to 533° F | Insulated | 19 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T794 | 000000 | ||
Type T | ||||||||||||||||||||||
Screw Terminal | ||||||||||||||||||||||
| 4 1/2" | 1/2" | Fixed | Not Rated | 660 | ±2.7° F Between 32° F to 533° F | Insulated | 13 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T773 | 000000 | ||
| 7 1/2" | 1/2" | Fixed | Not Rated | 660 | ±0.75% Above 533° F ±2.7° F Between 32° F to 533° F | Insulated | 16 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T783 | 000000 | ||
| 10 1/2" | 1/2" | Fixed | Not Rated | 660 | ±0.75% Above 533° F ±2.7° F Between 32° F to 533° F | Insulated | 19 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 4X | 14 | 6447T793 | 000000 | ||











































