    7 Products

    Hazardous Location Infrared Thermometers

    Image of Product. Front orientation. Thermometers. Hazardous Location Infrared Thermometers.
    These thermometers are rated for environments where hazardous material is present. They measure the temperature of surfaces without making contact and are often used to locate and diagnose problems in electrical, heating, and ventilation systems. Since they have adjustable emissivity, you can calibrate them for accurate readings of shiny surfaces. Maximum working distance is the distance a one-inch target can be reliably measured.
    Warning: These infrared thermometers are not intended for medical use. Use Noncontact Forehead Thermometers for medical use.
    Maximum Distance—Maximum working distance is the distance a one inch target can be reliably measured.
    Hazardous Location Rating—Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    Batteries
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Max. Distance,
    ft.
    Emissivity
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Includes
    Thermometer Features
    Hazardous Location Rating
    Certification
    Included
    Size
    No.
    of
    Each
    For Dark, Dull, Light, and Shiny Surfaces
     
    Adjustable Emissivity
    -40° F to 1,472° F/-40° C to 800° C0.1/0.1° C±1%300.1 to 10.57"2"6 1/2"PlasticCarrying CaseAutomatic Shutoff, Laser SightATEX II 2 G Ex Ia IIC T4 Gb
    Ex Ia IIC T4
    IEC Zone 1 Groups IIC, IIB, IIA
    IECEx Ex Ia IIC T4 Gb
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Zone 1 Groups IIC, IIB, IIA
    AEx Ia IIC T4
    C-ETL Listed, CE Marked, ETL Listed
    YesAAA22970N11000000000
     

    Noncontact Infrared Temperature Sensors

    Monitor the temperature of hazardous, sensitive, and hard-to-reach surfaces without touching them. IP or NEMA rated, these sensors are protected against dust and washdowns.
    Sensors with a thermocouple output communicate with devices that read thermocouple signals, so they work as replacements for thermocouples with the same output type.
    For Nonmetal Surfaces with 3.25 ft. Long Cable
    Image of Product. Front orientation. Noncontact Temperature Sensors. Noncontact Infrared Temperature Sensors, For Nonmetal.
    Sensors for nonmetal surfaces measure the temperature of plastics, fabrics, ceramics, and hot adhesives.
    3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)—Sensors with a micro USB cord and terminal block connect to your computer. Use the downloadable software to change the measurement temperature range and the output scale.
    Sensor
    Temp. Measurement
    Range, ° F
    Min. Object
    Size Detected
    Max. Sensing
    Distance, ft.
    Wavelength,
    μm
    Optical
    Resolution
    Accuracy @ Temperature
    Response
    Time, sec.
    Lg.
    Dia.
    Input Voltage,
    V DC
    For Panel
    Cutout Dia.
    Thread
    Size
    Includes
    Enclosure
    Rating
    Each
    0 to 5V DC, 0 to 10V DC, Type K Thermocouple Output Signal
     
    Adjustable Emissivity (0.1 to 1.1)
    -40 to 1,8860.24"2.68 to 1415:1±3° F Below 200° F
    ±1.5% Above 200° F
    0.0253 1/2"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)IP65
    3889K410000000
     
    4 to 20 mA Output Signal
     
    Adjustable Emissivity (0.1 to 1.1)
    -58 to 1,8860.26"3.28 to 1415:1±2° F Below 200° F
    ±1.5% Above 200° F
    0.0141 1/8"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)IP65, NEMA 4
    3889K42000000
     
    Accessories for Noncontact Temperature Sensors
    For Metal Surfaces with 3.25 ft. Long Cable
    Image of Product. Front orientation. Noncontact Temperature Sensors. Noncontact Infrared Temperature Sensors, For Metal.
    Sensors for metal surfaces measure the temperature of both solid metals, such as heating elements, and molten metals.
    3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)—Sensors with a micro USB cord and terminal block connect to your computer. Use the downloadable software to change the measurement temperature range and the output scale.
    Sensor
    Temp. Measurement
    Range, ° F
    Min. Object
    Size Detected
    Max. Sensing
    Distance, ft.
    Wavelength,
    μm
    Optical
    Resolution
    Accuracy @ Temperature
    Response
    Time, sec.
    Lg.
    Dia.
    Input Voltage,
    V DC
    For Panel
    Cutout Dia.
    Thread
    Size
    Includes
    Enclosure
    Rating
    Each
    4 to 20 mA Output Signal
     
    Adjustable Emissivity (0.1 to 1.1)
    122 to 6620.26"3.62.322:1±(0.3% of Temperature Measured + 3.6° F)0.021 1/4"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)IP65, NEMA 4
    3889K430000000
     
    Accessories for Noncontact Temperature Sensors
    back to top