McMaster-Carr logo
    Filter by
    Discharge Pipe Size
    Industrial Info Compare
    Intake Pipe Size
    Industrial Info Compare
    Electrical Phase
    Discharge Connection
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Frequency
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    41 Products

    Circulation Pumps for Fuel and Flammable Liquid

    Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    With Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Fuel and Flammable Liquid.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/208V AC to 240V AC, Single Phase—Hardwire
    25312519131621502641/27.4 amp/3.7 amp3/4 Female NPT1/2 Female NPT15 5/8"10 7/8"7 1/2"8205K440000000008205K4210000000
     
    208V AC to 240V AC/460V AC, Three Phase—Hardwire
    25312519131621502641/22.2 amp to 2.4 amp/1.1 amp3/4 Female NPT1/2 Female NPT15 5/8"10 7/8"7 1/2"8205K42000000008205K421000000
    100786448106415026412.8 amp/1.4 amp1 1/2 Female NPT1 Female NPT15 1/4"10 7/8"8 1/2"8205K43000000008205K431000000
     
    Repair Kits
    Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Fuel and Flammable Liquid.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/208V AC to 240V AC, Single Phase—Hardwire
    15104461502641/34.8 amp/2.4 amp3/4 Female NPT1/2 Female NPT15 1/2"10 7/8"7 1/2"8205K410000000008205K4110000000
    1007864481064150264112 amp/6 amp1 1/2 Female NPT1 Female NPT17 1/4"10 7/8"8 1/2"8205K45000000008205K431000000
     
    208V AC to 240V AC/460V AC, Three Phase—Hardwire
    1151009060811502641 1/24.6 amp to 5 amp/2.3 amp1 1/2 Female NPT1 Female NPT16 3/8"11 7/8"8 1/2"8205K46000000008205K461000000
    1251149878186915026425.4 amp to 5.7 amp/2.7 amp2 Female NPT1 1/2 Female NPT17 1/8"11 7/8"8 1/2"8205K47000000008205K471000000
    140120477515026437.6 amp to 8.1 amp/3.8 amp2 Female NPT1 1/2 Female NPT17 1/8"11 7/8"8 1/2"8205K48000000008205K461000000
     
    Repair Kits

    Hazardous Location Sump Pumps for Hot Water

    Image of Product. Front orientation. Sump Pumps. Hazardous Location Sump Pumps for Hot Water.
    These pumps have an explosion-proof motor that is rated for use where hazardous material is present. Since the motor is totally enclosed fan cooled (TEFC) and never comes into contact with the water, the pump can be used with hot water up to 300° F. A pedestal-mounted motor design provides easy access for maintenance. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump.
    Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
    Max. Flow
    Rate, gpm
    Level
    Discharge
    Min.
    Sump Pit
    Overall
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    @ 15 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Housing Material
    Turn-On
    Turn-Off
    Temp. Range,
    ° F
    Power,
    hp
    Max. Temp.,
    ° F
    Intake Inlet
    Type
    Connection
    Pipe
    Size
    Thread
    Type
    Gender
    Dia.
    Dp.
    Ht.
    Wd.
    Lg.
    Each
    120/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire and Screw Terminal
    606045321/4"316 Stainless Steel24"6"40 to 3001/2300ScreenedThreaded1 1/2
    NPT
    Female16"24"42"17"15"4323K34000000000
     

    Sanitary Electric Drum Pumps

    Image of Product. Front orientation. Drum Pumps. Sanitary Electric Drum Pumps, Nylon Housing.

    Nylon

    Housing

    Commonly used in food, beverage, pharmaceutical, and cosmetic processing, these pumps are designed for sanitary environments. The discharge connection can be easily disassembled for cleaning. Pumps do not include a drum connector.
    3-A Certified 02-11—Pumps that are 3-A certified meet sanitary design standards.
    CSA Certified—Pumps that are CSA certified meet stringent safety standards.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Connection
    For Tube
    OD
    Food Industry Std.
    Certification
    Each
    115V AC—Single Phase—Hardwire—With Thermal Overload Protection
     
    Nylon Housing
    3110551,0001517514.2 amp38 mm1 1/2"39"Quick Clamp1 1/2"3-A Certified 02-11
    CSA Certified
    3739N11000000000
     

    Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
    48.55514300-402101/25.341 mm1 5/8"39"Pump BodyBarbed
    1"MaleC-UL Listed
    UL Listed
    42675K4700000000042675K670000000
     
    Pump Replacement Parts

    Air-Powered Drum Pumps for Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Air-Powered Drum Pumps for Flammable Liquid.
    These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Features
    Each
    26551,100-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"39"Pump BodyBarbed
    1"MaleCE Marked
    Bonding and Grounding Wires, Hanger2824K39000000000
    26551,100-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"47"Pump BodyBarbed
    1"MaleCE Marked
    Bonding and Grounding Wires, Hanger2824K4900000000
    53551,000-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"39"Pump BodyBarbed
    1"MaleCE Marked
    Bonding and Grounding Wires, Hanger8252K1200000000
    53551,000-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"47"Pump BodyBarbed
    1"MaleCE Marked
    Bonding and Grounding Wires, Hanger8252K1400000000
     
    Pump Replacement Parts

    Self-Priming Circulation Pumps without Motor for Water

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Water.
    Also known as flexible impeller pumps, these create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Overall
    Shaft
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Ht.
    Lg.
    Wd.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    136026Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT3 13/16"4 1/2"4 1/8"5/8"1 1/8"1 15/16"4281K210000000
    27.96026Not Rated50 to 1803/41 Female NPT1 Female NPT3 9/16"6 3/8"4 3/4"5/8"2 1/4"1 7/8"4281K23000000
     
    Repair Kits

    Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals.
    Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
    316 Stainless Steel Housing—Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
    Temp.
    Intake
    Discharge
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    120V AC—Single Phase—Hardwire
     
    316 Stainless Steel Housing
    1815551,000Not Rated1751 1/39.12 NPT1 1/2"39"1"1 1/4"72"NEC Class I Divisions 1, 2 Group D
    IP55
    7133T27000000000
     

    Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. ZoomedIn view. Drum Pumps. Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel.
    These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. They have an automatic shut-off nozzle so they turn off when the tank is full. Lock the nozzle with a padlock (not included).
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Discharge (Hose
    and Nozzle)
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Includes
    Intake Pipe
    Connection
    Hose
    ID
    Hose Lg.,
    ft.
    Nozzle Type
    Max. Shackle
    Dia.
    Each
    12V DC—With Thermal Overload Protection
    252010-201254/1035152 NPT18-ft. Battery Cable, Drum Connector1 Female NPT1"18Automatic Shutoff
    Lockable
    5/16"2651K25000000000
     

    Self-Priming Circulation Pumps without Motor for Oil

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Oil.
    Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Shaft
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Ht.
    Lg.
    Wd.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    11.55021Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT5/8"1 1/8"1 15/16"3 13/16"4 1/2"4 1/8"4281K240000000
    255026Not Rated50 to 1803/41 Female NPT1 Female NPT5/8"2 1/4"1 7/8"3 9/16"6 3/8"4 3/4"4281K26000000
     
    Repair Kits
    back to top