Filter by
Product Family
Environment
Vacuum Type
Hazardous Location Protection Type
Air Filter Performance
Tank Material
System of Measurement
Hazardous Location Rating
Electrical Connection
Air Inlet Connection
Performance
Wheel Configuration
RoHS
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Hazardous Location Air-Powered Wet/Dry Vacuum Cleaners
Hose | Air Inlet | Air Hose | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Airflow @ Pressure | Dia. | Ht. | Dia. | Lg., ft. | Connection | Quick-Disconnect Style | Gender | Coupling Size | ID | Lg., ft. | Hazardous Location Rating | Features | Includes | Each | |||
Stainless Steel Tank | ||||||||||||||||||
| 18 | 40 ft³/min @ 90 psi | 16" | 43" | 1 1/2" | 15 | Quick Disconnect | Industrial | Male | 1/2 | 1/2" | 20 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | Liquid Overflow Shut-Off Valve | (1) 54" Long Extension Wand Crevice Tool Filter Bag Floor Nozzle Upholstery Nozzle | 4880N21 | 000000000 | ||
Hazardous Location Vacuum Cleaners for Dry Pickup
Hose | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Filter Efficiency @ 0.3 μm | Air Filter Performance | Ht. | Wd. | Dp. | Power, hp | Current, amp | Voltage, V AC | Dia. | Lg., ft. | Cord Lg., ft. | Hazardous Location Rating | Enclosure Rating | Certification | Includes | Each | |||
Stainless Steel Tank | |||||||||||||||||||
| 5 | 99.99% | High Efficiency, HEPA | 40" | 17" | 17" | 1.6 | 10.5 | 120 | 1 1/2" | 10 | 35 | NEC Class II Division 2 Groups F, G NEC Zone 22 Groups IIIC, IIIB, IIIA IEC Zone 22 Groups IIIC, IIIB, IIIA IECEx Ex Tc IIIC T200° C Dc ATEX II 1/3 D Ex Tc IIIC T200° C Dc C T3 | IP60 | CSA-US Certified, CSA Certified, CE Marked | Crevice Tool Floor Brush Round Brush Three Collection Bags Two 22" Lg. Extension Wands Upholstery Nozzle | 3219N11 | 000000000 | ||
Vacuum Cleaners for Combustible Metal Powder
Hose | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Filter Efficiency @ 0.3 μm | Air Filter Performance | Ht. | Wd. | Dp. | Power, hp | Current, amp | Voltage, V AC | Dia. | Lg., ft. | Cord Lg., ft. | Hazardous Location Rating | Enclosure Rating | Certification | Features | Includes | Each | |||
Stainless Steel Tank | ||||||||||||||||||||
| 1 1/2 | 99.97% | High Efficiency, HEPA | 53" | 22" | 26" | 1.3 | 9 | 120 | 1 1/2" | 10 | 50 | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G IEC Zone 1 Group IIA IEC Zone 21 Groups IIIC, IIIB, IIIA ATEX II 2 GD Ex D IIA T3 Gb Ex T IIIC T200° C Db | IP60 | CSA-US Certified, CSA Certified, CE Marked | Degassing Valve Liquid Level Indicator Removable Tank with Wheels | Crevice Tool Curved-Tip Nozzle Four Collection Bags Round Brush | 3527N1 | 0000000000 | ||
Vacuum Systems for Powered Sanders
Air Powered
Hose | Air Inlet | Quick-Disconnect Vacuum Air Outlet | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Airflow @ Pressure | Wd. | Ht. | Dp. | Dia. | Lg., ft. | Pipe Size | Thread Type | Gender | Coupling Size | Gender | Hazardous Location Rating | Certification | Flammability Rating | Each | |||
Stainless Steel Tank—Wall Mount | ||||||||||||||||||
| 1 1/2 | 35 ft³/min @ 80 psi | 18" | 30" | 16" | 1 1/4" | 20 | 1/2 | NPT | Male | 1/4 | Female | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA ATEX II 2 GD Ex H IIC T6 Gb Ex H IIIC T85° C Db | CE Marked | NFPA 484 | 5572N116 | 000000000 | ||
Stainless Steel Tank—With Wheels | ||||||||||||||||||
| 6 1/4 | 35 ft³/min @ 80 psi | 26" | 48" | 20" | 1 1/4" | 20 | 1/2 | NPT | Male | 1/4 | Female | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA ATEX II 2 GD Ex H IIC T6 Gb Ex H IIIC T85° C Db | CE Marked | NFPA 484 | 5572N115 | 000000000 | ||
| 10 | 45 ft³/min @ 80 psi | 20" | 39" | 27" | 1 1/4" | 20 | 1/2 | NPT | Male | 1/4 | Female | NEC Class II Division 2 Groups F, G IEC Zone 22 Groups IIIC, IIIB, IIIA ATEX II 3 D Ex H IIIC T85° C Dc | CE Marked | — | 5572N113 | 00000000 | ||
Electric
Hose | Air Inlet | Quick-Disconnect Vacuum Air Outlet | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Wd. | Ht. | Dp. | Dia. | Lg., ft. | Pipe Size | Thread Type | Gender | Coupling Size | Gender | Hazardous Location Rating | Enclosure Rating | Certification | Flammability Rating | Each | |||
Stainless Steel Tank—With Wheels | ||||||||||||||||||
Hardwire—120V AC | ||||||||||||||||||
| 6 1/4 | 26" | 48" | 26" | 1 1/4" | 20 | 1/2 | NPT | Male | 1/4 | Female | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G IEC Zone 1 Group IIA IEC Zone 21 Groups IIIC, IIIB, IIIA ATEX II 2 GD Ex D IIA T3 Gb Ex Tc IIIC T200° C Db | IP60 | CSA-US Certified, CSA Certified, CE Marked | NFPA 484 | 5572N114 | 0000000000 | ||
| 10 | 20" | 39" | 27" | 1 1/4" | 20 | 1/2 | NPT | Male | 1/4 | Female | NEC Class II Division 2 Groups F, G IEC Zone 22 Groups IIIC, IIIB, IIIA ATEX II 1/3 D Ex Tc IIIC T200° C Dc C T3 | IP60 | CSA-US Certified, CSA Certified, CE Marked | — | 5572N112 | 00000000 | ||
High-Flow Low-Pressure Hazardous Location Compressed Air Blowers
Single Stage
Overall | Pipe Size | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure | Max. Flow Rate @ Pressure | Vacuum Rating | Power, hp | Full Load Current @ Voltage | Volume (Sound), dBA | Lg. | Wd. | Ht. | Temp. Range, ° F | Inlet | Outlet | Hazardous Location Rating | Each | |||
Three Phase, 208/230/460V AC (Inverter Rated) | ||||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||||
| 2 psi 50 in. H₂O | 556 ft³/min @ 0 psi | 3.7 in. Hg 50 in. H₂O | 10 | 24.3 amp @ 208V AC 22.4 amp @ 230V AC 11.2 amp @ 460V AC | 81 | 25" | 20" | 22" | 5 to 100 | 4 | 4 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | 4393K74 | 000000000 | ||
| 2 psi 60 in. H₂O | 471 ft³/min @ 0 psi | 4.4 in. Hg 59 in. H₂O | 10 | 24.3 amp @ 208V AC 22.4 amp @ 230V AC 11.2 amp @ 460V AC | 81 | 25" | 19" | 22" | 5 to 100 | 4 | 4 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | 4393K73 | 00000000 | ||
| 2 psi 68 in. H₂O | 381 ft³/min @ 0 psi | 5 in. Hg 67 in. H₂O | 7 1/2 | 18.9 amp @ 208V AC 17.8 amp @ 230V AC 8.9 amp @ 460V AC | 80 | 23" | 18" | 19" | 5 to 100 | 3 | 3 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | 4393K72 | 00000000 | ||
| 4 psi 116 in. H₂O | 294 ft³/min @ 0 psi | 8.8 in. Hg 119 in. H₂O | 7 1/2 | 18.9 amp @ 208V AC 17.8 amp @ 230V AC 8.9 amp @ 460V AC | 80 | 23" | 16" | 19" | 5 to 100 | 3 | 3 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | 4393K71 | 00000000 | ||
Two Stage
Overall | Pipe Size | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure | Max. Flow Rate @ Pressure | Vacuum Rating | Power, hp | Full Load Current @ Voltage | Volume (Sound), dBA | Lg. | Wd. | Ht. | Temp. Range, ° F | Inlet | Outlet | Hazardous Location Rating | Each | |||
Three Phase, 208/230/460V AC (Inverter Rated) | ||||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||||
| 3 psi 110 in. H₂O | 220 ft³/min @ 0 psi | 8.1 in. Hg 110 in. H₂O | 7 1/2 | 18.9 amp @ 208V AC 17.8 amp @ 230V AC 8.9 amp @ 460V AC | 78 | 27" | 19" | 22" | 5 to 100 | 4 | 4 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | 4393K77 | 000000000 | ||
| 4 psi 115 in. H₂O | 274 ft³/min @ 0 psi | 8.5 in. Hg 115 in. H₂O | 10 | 24.3 amp @ 208V AC 22.4 amp @ 230V AC 11.2 amp @ 460V AC | 81 | 27" | 20" | 22" | 5 to 100 | 4 | 4 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | 4393K78 | 00000000 | ||
| 5 psi 150 in. H₂O | 167 ft³/min @ 0 psi | 11 in. Hg 149 in. H₂O | 7 1/2 | 18.9 amp @ 208V AC 17.8 amp @ 230V AC 8.9 amp @ 460V AC | 77 | 23" | 18" | 19" | 5 to 100 | 2 | 2 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | 4393K76 | 00000000 | ||
| 8 psi 240 in. H₂O | 128 ft³/min @ 0 psi | 11.9 in. Hg 161 in. H₂O | 7 1/2 | 18.9 amp @ 208V AC 17.8 amp @ 230V AC 8.9 amp @ 460V AC | 75 | 27" | 16" | 19" | 5 to 100 | 2 | 2 | NEC Class I Divisions 1, 2 Group D NEC Class II Division 2 Groups F, G | 4393K75 | 00000000 | ||
Drum-Mount Two-Stage Dust Collectors
Dust Collectors | Dust Collector Filters | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Filter | For Drum | |||||||||||||||||||
Airflow @ SP | Area, ft² | Efficiency @ 5 Microns | Efficiency @ 10 Microns | Power, hp | Freq., Hz | Current | Inlet Dia. | Filter Bag Ht. | Cap., gal. | Dia. | Volume (Sound) @ Distance | Material | No. of Wire Leads | Environment | Each | Each | ||||
Three-Phase Motor—Hardwire | ||||||||||||||||||||
230V AC/460V AC | ||||||||||||||||||||
| 450 ft³/min @ 0 in. H₂O | 12 1/2 | — | 99% | 1/2 | 60 | 2 amp/1 amp | 4" | 24" | 20, 24, 30 | 18" to 20" | 78 dBA @ 5 ft. | Steel | 12 | Hazardous, Wet | 2114K84 | 000000000 | 2114K9 | 0000000 | ||
| 700 ft³/min @ 0 in. H₂O | 18 | 99% | — | 1 | 60 | 2.8 amp/1.4 amp | 6" | 29" | 55 | 22" to 24" | 83 dBA @ 5 ft. | Steel | 9 | Hazardous, Wet | 2114K85 | 00000000 | 2114K4 | 000000 | ||