    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Belt Drive—Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged. They come with collars, so you can connect these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Includes
    Each
    Each
    12"1,600Not RatedDirect1,72511/416 1/8"16 1/8"17 3/4"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    000000000000000000000000000000
    16"2,80061 dBA @ 15 ft.Direct1,72511/320 1/8"20 1/8"15"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    0000000000000000000000000000
    20"4,80073 dBA @ 5 ft.Direct1,72511/224 1/8"24 1/8"19 1/2"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    0000000000000000000000000000
    24"6,50071 dBA @ 5 ft.Direct1,12513/430 1/8"30 1/8"29 1/8"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D
    0000000000000000000000000000
    30"9,84071 dBA @ 10 ft.Belt1,72513/434 3/4"34 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar000000000000000———0
    36"11,00072 dBA @ 10 ft.Belt1,72513/440 3/4"40 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar000000000000000———0
    42"14,60074 dBA @ 10 ft.Belt1,72513/446 3/4"46 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar000000000000000———0
    48"19,10070 dBA @ 10 ft.Belt1,72513/452 3/4"52 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar000000000000000———0
    230/460V AC, Three Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Cannot Be Sold to California—Fans that cannot be sold to California do not meet energy efficiency requirements.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Cannot Be
    Sold To
    Each
    Each
    20"4,80073 dBA @ 5 ft.Direct1,72511/224 1/8"24 1/8"19 1/2"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    000000000000000000000000000000
    30"11,00077 dBA @ 5 ft.Direct1,12511 1/236 1/8"36 1/8"29 1/4"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    California0000000000000000000000000000
    36"15,50080 dBA @ 5 ft.Direct1,1251242 1/8"42 1/8"29 3/4"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    California0000000000000000000000000000

    Hazardous Location Equipment-Cooling Fan Kits

    Cool electronics and other sensitive equipment in potentially unsafe areas. These fans are non-sparking, so they’re safe for use around gas and explosive dust. They also withstand washdowns, occasional submersion in water, and wet weather. They’re not for use in mines. Ball bearings reduce the heat that’s generated to prolong fan lifespan.
    Square
    Image of Product. Front orientation. Fans. Hazardous Location Equipment-Cooling Fan Kits.
    Overall
    Mounting
    Ht.
    Wd.
    Dp.
    Airflow,
    ft³/min
    Temp. Range,
    ° F
    Volume (Sound),
    dBA
    Current,
    amp
    Frame
    Material
    Fasteners
    Included
    Hole Dia.
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Guard
     
    120V AC, Single Phase, 50 Hz, 60 Hz—Two Blade Plug
    4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)1060 to 155430.08AluminumNo0.17" (4.3 mm)ATEX II 3 G Ex nA IIC Gc; IEC Zone 2 Groups IIC, IIB, IIAIP68
    C-UL Listed, UL Listed, UL Recognized Component
    00000000000000
     

    Hazardous Location Upblast Roof-Mount Exhaust Fans

    With a UL-listed motor, these fans can be used in hazardous environments with combustible gases and dust to draw stagnant and humid air out through your roof, forcing it up and away from its surface.
    Direct Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,900 ft³/min @ 1/2 in. H₂O
    6,900 ft³/min @ 0 in. H₂O
    75 dBA @ 5 ft.1,1503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    000000000000000000000000000000
    30"5,900 ft³/min @ 1/2 in. H₂O
    9,350 ft³/min @ 0 in. H₂O
    72 dBA @ 5 ft.1,150139"28"42"370100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
     
    240/460V AC, Three Phase—Hardwire
    36"15,700 ft³/min @ 1/2 in. H₂O
    21,000 ft³/min @ 0 in. H₂O
    79 dBA @ 5 ft.1,150345"31"48"480100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
    42"19,400 ft³/min @ 1/2 in. H₂O
    25,300 ft³/min @ 0 in. H₂O
    80 dBA @ 5 ft.1,150351"34"54"520100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
    48"31,600 ft³/min @ 1/2 in. H₂O
    36,200 ft³/min @ 0 in. H₂O
    89 dBA @ 5 ft.1,1507 1/257"37"60"670100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
     
    Belt Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,530 ft³/min @ 1/2 in. H₂O
    6,150 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,7503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    000000000000000000000000000000
    30"2,950 ft³/min @ 1/2 in. H₂O
    9,800 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,7503/439"28"42"410100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
     
    240/460V AC, Three Phase—Hardwire
    36"20,200 ft³/min @ 1/2 in. H₂O
    24,100 ft³/min @ 0 in. H₂O
    82 dBA @ 5 ft.1,750545"31"48"590100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
    42"22,400 ft³/min @ 1/2 in. H₂O
    27,800 ft³/min @ 0 in. H₂O
    78 dBA @ 5 ft.1,750551"34"54"720100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
    48"28,600 ft³/min @ 1/2 in. H₂O
    36,700 ft³/min @ 0 in. H₂O
    80 dBA @ 5 ft.1,750557"37"60"840100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
     