McMaster-Carr logo
    Filter by
    System of Measurement
    Memory Size
    Diagonal Screen Size
    Manufacturer
    Input Voltage
    Industrial Info Snippet
    Bezel Material
    IoT Communication Protocol
    Maximum Temperature
    Number of Ethernet Connections
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Snippet
    Screen Aspect Ratio
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    7 Products

    Hazardous Location HMIs

    Image of ProductInUse. Shown Mounted (Enclosure Not Included). Front orientation. HMIs. Hazardous Location HMIs .

    Shown Mounted (Enclosure Not Included)

    From chemical plants to refineries, these HMIs let you safely control and monitor equipment in areas where flammable and combustible gases, vapors, and liquids may escape from leaks or failures. They’re rated for use in NEC Class 1, Division 2 hazardous locations. Since they come with a touchscreen and software designed specifically to integrate with your PLC, you don’t need to spend time or money on the complex setup and extra equipment of industrial PCs.
    The manufacturer’s free PC software guides you through communication setup and screen design using drag-and-drop tools. Preview your layout, test navigation, and catch design errors before you connect to any equipment. When you’re ready, transfer your setup to the HMI with a USB cord, memory card, or Ethernet cord.
    All of our HMIs support the PLCs we currently offer, plus those from systems such as Allen-Bradley and Siemens.
    When mounted in an enclosure, the front of these HMIs is NEMA 4X and IP rated for protection against dust and light washdowns.
    All of these HMIs are compatible with RFID readers.
    Pressure Activated Touchscreen
    HMIs with a pressure-activated touchscreen respond to firm pressure, so you can use them while wearing gloves. They also work with a stylus, screwdriver handle, and other hard objects.
    Built-In RFID Antenna—HMIs with a built-in RFID antenna let you log in and trigger actions without external readers, reducing components that could spark or fail.
    Number of Supported Communication Drivers—Use the number of supported drivers to gauge compatibility. If your PLC is common, HMIs with fewer drivers likely support it, so you won’t need to pay for extra compatibility. Drivers for specific PLCs save you setup time. However, you can always use a standard protocol such as Modbus RTU or EtherNet/IP—just expect more manual setup.
    Maximum Screen Brightness—Maximum screen brightness is measured in candelas per square meter (cd/m2). 400 cd/m2 is similar to an office monitor, 800 cd/m2 suits bright factory floors, and 1200 cd/m2 stays visible even in direct sunlight.
    Diag. Screen
    Size
    No. of Supported
    Communication Drivers
    Screen
    Resolution
    Max. Screen
    Brightness, cd/m²
    Serial Port Interface
    (No. of)
    Connection Type
    (No. of)
    Memory Type
    (Size)
    Features
    Housing
    Material
    Operating
    Temp. Range, ° F
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    7"4401024 × 6001,200RS-232 (1)
    RS-485/
    CAN-Bus (1)
    Ethernet RJ45 (2)
    USB-A (1)
    Flash (4 GB)
    RAM (1 GB)
    Aluminum
    0 to 130IP66
    NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D
    UL Listed
    C-UL Listed
    CE Marked
    8872N120000000
    10.1"4401024 × 600350RS-232 (1)
    RS-485/
    CAN-Bus (1)
    Ethernet RJ45 (2)
    USB-A (1)
    Flash (4 GB)
    RAM (1 GB)
    Built-In RFID AntennaPlastic32 to 120IP66
    NEMA 4X
    ATEX II 3 G Ex Ec IIC T6 Gc
    ATEX II 3 G Ex Tc IIIB T80° C Dc
    IEC Zone 2 Groups IIC, IIB, IIA
    IEC Zone 22 Groups IIIB, IIIA
    NEC Class I Division 2 Groups A, B, C, D
    UL Listed
    C-UL Listed
    CE Marked
    8872N1300000000
    10.1"4401280 × 800500RS-232 (1)
    RS-485/
    CAN-Bus (1)
    Ethernet RJ45 (2)
    USB-A (1)
    Flash (4 GB)
    RAM (1 GB)
    Built-In SpeakerPlastic32 to 130IP66
    NEMA 4X
    ATEX II 3 G Ex Ec IIC T6 Gc
    ATEX II 3 G Ex Tc IIIB T80° C Dc
    IEC Zone 2 Groups IIC, IIB, IIA
    IEC Zone 22 Groups IIIB, IIIA
    NEC Class I Division 2 Groups A, B, C, D
    UL Listed
    C-UL Listed
    CE Marked
    8872N1400000000
    Screen Protectors
    Gesture Enabled Touchscreen
    HMIs with a gesture-enabled touchscreen let you tap, swipe, pinch, and more to quickly navigate through dashboards and trigger actions. Keep in mind that these HMIs won’t work with gloves unless they’re touchscreen compatible.
    IP68 Enclosure Rating—Those that are IP68 rated are protected from temporary submersion.
    Number of Supported Communication Drivers—Use the number of supported drivers to gauge compatibility. If your PLC is common, HMIs with fewer drivers likely support it, so you won’t need to pay for extra compatibility. Drivers for specific PLCs save you setup time. However, you can always use a standard protocol such as Modbus RTU or EtherNet/IP—just expect more manual setup.
    Maximum Screen Brightness—Maximum screen brightness is measured in candelas per square meter (cd/m2). 400 cd/m2 is similar to an office monitor, 800 cd/m2 suits bright factory floors, and 1200 cd/m2 stays visible even in direct sunlight.
    Diag. Screen
    Size
    No. of Supported
    Communication Drivers
    Screen
    Resolution
    Max. Screen
    Brightness, cd/m²
    Serial Port Interface
    (No. of)
    Connection Type
    (No. of)
    Memory Type
    (Size)
    Features
    Housing
    Material
    Operating
    Temp. Range, ° F
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    7"50800 × 4801,000RS-232 (1)
    RS-422/
    RS-485 (1)
    Ethernet RJ45 (2)
    USB-A (1)
    Mini USB-B (1)
    Standard SD Card (1)
    3.5 mm Audio Output (1)
    Flash (8 GB)
    SDRAM (1 GB)
    Aluminum
    0 to 145IP68
    NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D
    UL Listed
    C-UL Listed
    CE Marked
    8872N110000000
    10.1"4401280 × 800425RS-232 (1)
    RS-485/
    CAN-Bus (1)
    Ethernet RJ45 (2)
    USB-A (1)
    Flash (4 GB)
    RAM (1 GB)
    Built-In SpeakerPlastic32 to 130IP66
    NEMA 4X
    ATEX II 3 G Ex Ec IIC T6 Gc
    ATEX II 3 G Ex Tc IIIB T80° C Dc
    IEC Zone 2 Groups IIC, IIB, IIA
    IEC Zone 22 Groups IIIB, IIIA
    NEC Class I Division 2 Groups A, B, C, D
    UL Listed
    C-UL Listed
    CE Marked
    8872N1500000000
    Screen Protectors
    back to top