McMaster-Carr logo
    Filter by
    Pipe Size
    Industrial Info Compare
    Number of Ports
    Total Number of Ports
    Hydraulic Tank Type
    For Maximum Hydraulic Cylinder Stroke Length
    Electrical Phase
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    76 Products

    Hydraulic Tanks

    Image of Product. Front orientation. Hydraulic Tanks. Style A.
    Image of Product. Front orientation. Hydraulic Tanks. Style B.
    Image of Product. Front orientation. Hydraulic Tanks. Style C.

    Style A

    Style B

    Style C

    Store fluids for a hydraulic power unit or circulating-oil system. Choose a tank capacity about three times greater than your requirement to allow for heat dissipation. Tanks with only a drain connection require you to drill your own inlet/outlet connection and add pipe suction flanges (sold separately). Flanges seal pipes that pass through the top plate of your tank.
    Dual Chamber Tanks—Dual chamber tanks have a divider that allows particles to settle on one side before fluid is returned to your line.
    Style C—To install the breather vent to Style C tanks, drill a hole in the tank.
    Overall
    Drain
    Inlet/Outlet
    Mounting
    Style
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Pipe
    Size
    Dash
    Size
    No. of
    Ports
    Pipe
    Size
    Dash
    Size
    No. of
    Ports
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Max. Temp.,
    ° F
    Each
    Steel
     
    Single Chamber Tanks
    A16"7 1/2"12 1/4"1/2 NPT081No411/32"25000000000000000
    A210"7 1/2"12 1/4"1/2 NPT0811/2 NPT081No411/32"2500000000000000
    B210 1/8"10 1/8"9 1/8"1/2 NPT081No47/16"21200000000000000
    B310 1/8"10 1/8"13 1/8"1/2 NPT081No47/16"21200000000000000
    B510 1/8"10 1/8"17 1/8"1/2 NPT081No47/16"21200000000000000
    B814 1/4"12"19 1/4"3/4 NPT121No47/16"21200000000000000
    B1019"14 7/8"15 1/4"3/4 NPT121No47/16"21200000000000000
     
    Dual Chamber Tanks
    A516"10"14"1/2 NPT0821 NPT162No417/32"2500000000000000
    A1020"12"17 1/2"1/2 NPT0821 NPT162No417/32"2500000000000000
    C2026"16"15 3/4"3/4 NPT121No41/2"21200000000000000
    C3026"16"21 3/4"3/4 NPT121No41/2"21200000000000000
    C4038 1/4"24"14"3/4 NPT121No47/16"21200000000000000
    C6042 3/8"30"16 5/8"3/4 NPT121No47/16"2120000000000000000
    C10050 3/8"30"19"3/4 NPT121No47/16"2120000000000000000
     
    Accessories and Replacements for Hydraulic Tanks

    Hydraulic Power Units

    Image of Product. Front orientation. Hydraulic Power Units.
    Create and supply hydraulic pressure. Choose a unit with a tank capacity about three times greater than your requirement to allow for heat dissipation. An inlet filter protects the pump from contamination.
    All units include an additional NPTF threaded inlet port. NPTF (Dryseal) threads are compatible with NPT threads. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Overall
    Inlet Connection —
    UN/UNF (SAE Straight)
    Inlet
    Connection — NPTF
    Outlet Connection —
    UN/UNF (SAE Straight)
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Power,
    hp
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Thread
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    Thread
    Size
    Dash Size
    Full Load Current
    @ Voltage
    Each
    240V AC/460V AC, Three Phase
    0.91,6001513"15"20 1/2"7/8"-14
    101/2
    087/8"-14
    101.5 amp @ 460V AC00000000000000000
    1.32,3002513"15"24 1/2"7/8"-14
    101/2
    087/8"-14
    102.8 amp @ 460V AC0000000000000000
    2.71,75031017 3/8"19"32 1/2"1 1/16"-12
    123/4
    121 1/16"-12
    124.4 amp @ 460V AC0000000000000000
    3.62,05051017 3/4"19"29 3/4"1 1/16"-12
    123/4
    121 1/16"-12
    126.8 amp @ 460V AC0000000000000000
    6.31,8007 1/22021 3/8"22 1/2"37 3/8"1 1/16"-12
    123/4
    121 1/16"-12
    129.5 amp @ 460V AC0000000000000000
    8.61,700103021 3/8"22 1/2"42 1/4"1 1/16"-12
    123/4
    121 1/16"-12
    1212 amp @ 460V AC0000000000000000
    10.42,100153023 3/8"22 1/2"44 1/8"1 1/16"-12
    123/4
    121 1/16"-12
    1218.1 amp @ 460V AC00000000000000000
     

    Air to Hydraulic Power Units

    Image of Product. Front orientation. Air to Hydraulic Power Units.
    Power a hydraulic cylinder from your air system to avoid the setup, cost, and mess of hydraulic fluid. These converters give you more consistent power than using air power for an air cylinder. However, because air works at a lower pressure than hydraulic fluid, your hydraulic cylinder won’t move loads at its full force. Attach these converters to an air line with a speed controller and solenoid (not included).
    Note: These converters are not for use near fire.
    Oil
    Displacement, mm
    Overall,
    mm
    Inlet
    Connection—BSPT
    Outlet
    Connection—BSPT
    Drain
    Connection—BSPT
    Mounting
    Holes
    Max.
    Increments
    For Max. Hydraulic
    Cylinder Stroke Lg., mm
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Cap.,
    gal.
    Wd.
    Ht.
    Pipe
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    No.
    of
    Dia.,
    mm
    Features
    Each
    For 40 mm Bore Dia.
    5050603.31000.021072131/4
    061/4
    0647Drain Plug0000000000000
    100501203.31000.031072631/4
    061/4
    0647Drain Plug000000000000
    150501803.31000.051073131/4
    061/4
    0647Drain Plug000000000000
    200502503.31000.071073631/4
    061/4
    0647Drain Plug000000000000
     
    For 63 mm Bore Dia.
    50501507.91000.041042283/8
    063/4
    121/4
    06411Drain Plug000000000000
    100503007.91000.081042783/8
    063/4
    121/4
    06411Drain Plug0000000000000
    200506007.91000.161043783/8
    063/4
    121/4
    06411Drain Plug0000000000000
    300508907.91000.241045033/8
    063/4
    121/4
    06411Drain Plug0000000000000
     

    Sealed Hydraulic Accumulators

    Charge these accumulators to the pressure you need, and they will help a system maintain a constant pressure during pump failure. Mount them in any orientation. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Note: For safety, do not disassemble accumulators while they're under pressure.
    Diaphragm Accumulator
    Image of Product. Front orientation. Hydraulic Accumulators. Sealed Hydraulic Accumulators, Diaphragm Accumulator.
    Diaphragm accumulators have bags that can't be replaced.
    Inlet/Outlet Connection
    for Hydraulic Fluid
    Inlet/Outlet
    Connection for Nitrogen
    Body
    Cap., fl.
    oz.
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Thread
    Size
    Thread Type
    Gender
    Dash
    Size
    Valve
    Type
    Gender
    Overall
    Ht.
    Ht.
    Dia.
    Mounting
    Position
    Each
    Steel Body with Buna-N Diaphragm
    16 1/2253,0003/4"-16
    UN/UNF (SAE Straight)
    Female08SchraderMale6 7/8"4 3/8"4 1/8"Any Angle00000000000000
    33 1/2253,0003/4"-16
    UN/UNF (SAE Straight)
    Female08SchraderMale7 7/8"5 3/8"5 3/8"Any Angle0000000000000
    66 1/2403,0001 1/16"-12
    UN/UNF (SAE Straight)
    Female12SchraderMale9 1/4"6 13/16"6 5/8"Any Angle0000000000000
     
    Charging and Gauging Kits
    Piston Accumulator
    Image of Product. Front orientation. Hydraulic Accumulators. Sealed Hydraulic Accumulators, Piston Accumulator.
    Inlet/Outlet Connection
    for Hydraulic Fluid
    Inlet/Outlet
    Connection for Nitrogen
    Body
    Cap., fl.
    oz.
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Thread
    Size
    Thread Type
    Gender
    Dash
    Size
    Valve
    Type
    Gender
    Overall
    Ht.
    Ht.
    Dia.
    Mounting
    Position
    Each
    Steel Body with Buna-N Seal
    161004,0003/4"-16
    UN/UNF (SAE Straight)
    Female08SchraderMale13 3/8"12 7/16"2 3/8"Any Angle00000000000000
    321004,0003/4"-16
    UN/UNF (SAE Straight)
    Female08SchraderMale21 7/8"20 15/16"2 3/8"Any Angle0000000000000
     
    Charging and Gauging Kits

    Slim-Shaft Hydraulic Power Units

    Image of Product. Front orientation. Hydraulic Power Units. Slim-Shaft Hydraulic Power Units.
    Image of Product. Front orientation. Hydraulic Tanks. Slim-Shaft Hydraulic Power Units.

    Replacement Hydraulic Tanks

    Mount these units to an existing machine or where space is limited. They create and supply hydraulic pressure where standard models won’t fit. Choose a unit with a tank capacity about three times greater than your requirement to allow for heat dissipation.
    Hydraulic Power Units
    Replacement
    Hydraulic Tanks
    Overall
    Inlet
    Connection — NPT
    Outlet
    Connection — NPT
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Power,
    hp
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Pipe
    Size
    Dash
    Size
    Pipe Size
    Dash
    Size
    Full Load Current
    @ Voltage
    Each
    Each
    120V AC/240V AC, Single Phase
    12,50022.336 1/8"8 1/8"8 5/8"1/4
    043/8
    0610 amp @ 240V AC0000000000000000000000000000000
    1.52,50022.334 7/8"8 1/8"8 5/8"1/4
    043/8
    0610 amp @ 240V AC00000000000000000000000000000
     

    Bladder-Style Hydraulic Accumulators

    Image of Product. Front orientation. Hydraulic Accumulators. Bladder-Style Hydraulic Accumulators.
    Charge these accumulators to the pressure you need, and they will help a system maintain a constant pressure during pump failure. Mount accumulators within 25° of vertical. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Note: For safety, do not disassemble accumulators while they're under pressure.
    Accumulators
    Replacement
    Bladders
    Inlet/Outlet Connection
    for Hydraulic Fluid
    Inlet/Outlet
    Connection for Nitrogen
    Body
    Cap.
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Thread
    Size
    Thread Type
    Gender
    Dash
    Size
    Valve
    Type
    Gender
    Overall
    Ht.
    Ht.
    Dia.
    Mounting
    Position
    Each
    Each
    Steel Body with Buna-N Bag and Buna-N Seal
    16 fl. oz.403,0001 1/16"-12
    UN/UNF (SAE Straight)
    Female12SchraderMale10 3/4"6 7/8"3 3/8"Vertical00000000000000000000000000000000
    32 fl. oz.403,0001 5/16"-12
    UN/UNF (SAE Straight)
    Female16SchraderMale11 1/8"7 5/8"4 1/2"Vertical000000000000000000000000000000
    1 gal.1503,0001 5/8"-12
    UN/UNF (SAE Straight)
    Female20SchraderMale17"11 3/8"6 3/4"Vertical000000000000000000000000000000
    2 1/2 gal.2203,0001 7/8"-12
    UN/UNF (SAE Straight)
    Female24SchraderMale21 3/8"15 1/2"9"Vertical000000000000000000000000000000
    5 gal.2203,0001 7/8"-12
    UN/UNF (SAE Straight)
    Female24SchraderMale33 3/8"27 1/2"9"Vertical00000000000000000000000000000000
     
    Charging and Gauging Kits

    Charged Bladder-Style Hydraulic Accumulators

    Image of Product. Front orientation. Hydraulic Accumulators. Charged Bladder-Style Hydraulic Accumulators.
    These accumulators come with a charge of nitrogen and are ready to use. They help a system maintain a constant pressure during pump failure. Mount accumulators within 25° of vertical. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Note: For safety, do not disassemble accumulators while they're under pressure.
    Accumulators
    Replacement
    Bladders
    Inlet/Outlet Connection
    for Hydraulic Fluid
    Inlet/Outlet
    Connection for Nitrogen
    Body
    Cap.
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Nitrogen
    Charge, psi
    Thread
    Size
    Thread Type
    Gender
    Dash
    Size
    Valve
    Type
    Gender
    Overall
    Ht.
    Ht.
    Dia.
    Mounting
    Position
    Each
    Each
    Steel Body with Buna-N Bag and Buna-N Seal
    16 fl. oz.403,0001,0001 1/16"-12
    UN/UNF (SAE Straight)
    Female12SchraderMale10 3/4"6 7/8"3 3/8"Vertical00000000000000000000000000000000
    32 fl. oz.403,0001,0001 5/16"-12
    UN/UNF (SAE Straight)
    Female16SchraderMale11 1/8"7 5/8"4 1/2"Vertical000000000000000000000000000000
    1 gal.1503,0002,1001 5/8"-12
    UN/UNF (SAE Straight)
    Female20SchraderMale17"11 3/8"6 3/4"Vertical000000000000000000000000000000
    2 1/2 gal.2203,0002,1001 7/8"-12
    UN/UNF (SAE Straight)
    Female24SchraderMale21 3/8"15 1/2"9"Vertical000000000000000000000000000000
    5 gal.2203,0002,1001 7/8"-12
    UN/UNF (SAE Straight)
    Female24SchraderMale33 3/8"27 1/2"9"Vertical00000000000000000000000000000000
     
    Charging and Gauging Kits

    Charged Sealed Hydraulic Accumulators

    These accumulators come with a charge of nitrogen and are ready to use. They help a system maintain a constant pressure during pump failure. Mount these accumulators in any orientation. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Note: For safety, do not disassemble accumulators while they're under pressure.
    Diaphragm Accumulator
    Image of Product. Front orientation. Hydraulic Accumulators. Charged Sealed Hydraulic Accumulators, Diaphragm Accumulator.
    Diaphragm accumulators have bags that can't be replaced.
    Inlet/Outlet Connection
    for Hydraulic Fluid
    Inlet/Outlet
    Connection for Nitrogen
    Body
    Cap., fl.
    oz.
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Nitrogen
    Charge, psi
    Thread
    Size
    Thread Type
    Gender
    Dash
    Size
    Valve
    Type
    Gender
    Overall
    Ht.
    Ht.
    Dia.
    Mounting
    Position
    Each
    Steel Body with Buna-N Diaphragm
    16 1/2253,0001,0003/4"-16
    UN/UNF (SAE Straight)
    Female08SchraderMale6 7/8"4 3/8"4 1/8"Any Angle00000000000000
    66 1/2403,0001,0001 1/16"-12
    UN/UNF (SAE Straight)
    Female12SchraderMale9 1/4"6 13/16"6 5/8"Any Angle000000000000000
     
    Charging and Gauging Kits
    Piston Accumulator
    Image of Product. Front orientation. Hydraulic Accumulators. Charged Sealed Hydraulic Accumulators, Piston Accumulator.
    Inlet/Outlet Connection
    for Hydraulic Fluid
    Inlet/Outlet
    Connection for Nitrogen
    Body
    Cap., fl.
    oz.
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Nitrogen
    Charge, psi
    Thread
    Size
    Thread Type
    Gender
    Dash
    Size
    Valve
    Type
    Gender
    Overall
    Ht.
    Ht.
    Dia.
    Mounting
    Position
    Each
    Steel Body with Buna-N Seal
    161004,0001,0003/4"-16
    UN/UNF (SAE Straight)
    Female08SchraderMale13 3/8"12 7/16"2 3/8"Any Angle00000000000000
    321004,0001,0003/4"-16
    UN/UNF (SAE Straight)
    Female08SchraderMale21 7/8"20 15/16"2 3/8"Any Angle0000000000000
     
    Charging and Gauging Kits
    back to top