IEC Safe-Break Pin-and-Sleeve Connectors
These connectors meet international standards IEC 309-1 and 309-2, so they’re compatible with other IEC 309 devices. They allow you to connect and disconnect with the power on—spring-loaded contacts open like a switch when separating the connectors, preventing an electrical arc. All are approved as switch-rated connectors for branch and motor circuit disconnect switching. Connectors have a ground pin that is included in the number of wires. Rated NEMA 4X, 12, and IP69K, they're protected against corrosion, oil/coolant seepage, washdowns, and high-temperature, high-pressure washdowns.
For technical drawings and 3-D models, click on a part number.


2W3P
Male

2W3P
Male

2W3P
Male

AC, 3W4P
Male

AC, 3W4P
Male

3W4P
Male

3W4P
Male

AC, 4W5P
Male

AC, 4W5P
Male

AC, 4W5P
Male

240/415V AC,
4W5P Male

3W4P
Male
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Environmental Rating | Choose a Voltage | Each | |
2" | 3 | 1 | 2 | 2W3P | Single | 30A | Screw Terminals | 12-8 | 0.5"-1.25" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 0000000 | |
2" | 4 | 1 | 3 | 3W4P | Single | 30A | Screw Terminals | 12-8 | 0.5"-1.22" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 4 | 1 | 3 | 3W4P | Three | 30A | Screw Terminals | 12-8 | 0.5"-1.22" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 220V AC/380V AC and 240V AC/415V AC | 0000000 | 000000 |
2.5" | 3 | 1 | 2 | 2W3P | Single | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2.5" | 5 | 1 | 4 | 4W5P | Three | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 277V AC/480V AC | 0000000 | 000000 |


2W3P
Female

2W3P
Female

2W3P
Female

AC, 3W4P
Female

AC, 3W4P
Female

3W4P
Female

3W4P
Female

AC, 4W5P
Female

AC, 4W5P
Female

AC, 4W5P
Female

240/415V AC,
4W5P Female

3W4P
Female
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Features | Environmental Rating | Choose a Voltage | Each | |
2" | 3 | 1 | 2 | 2W3P | Single | 30A | Screw Terminals | 12-8 | 0.5"-1.25" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 0000000 | 0000000 | |
2" | 4 | 1 | 3 | 3W4P | Single | 30A | Screw Terminals | 12-8 | 0.5"-1.25" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 4 | 1 | 3 | 3W4P | Three | 30A | Screw Terminals | 12-8 | 0.5"-1.25" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 220V AC/380V AC and 240V AC/415V AC | 0000000 | 000000 |
2.5" | 3 | 1 | 2 | 2W3P | Single | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 0000000 | 00000000 | |
2.5" | 5 | 1 | 4 | 4W5P | Three | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 277V AC/480V AC | 0000000 | 00000000 |


2W3P
Female

2W3P
Female

2W3P
Female

AC, 3W4P
Female

AC, 3W4P
Female

3W4P
Female

3W4P
Female

AC, 4W5P
Female

AC, 4W5P
Female

AC, 4W5P
Female

240/415V AC,
4W5P Female

3W4P
Female
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | Features | Temp. Range, °F | Environmental Rating | Choose a Voltage | Each | |
2" | 3 | 1 | 2 | 2W3P | Single | 30A | Screw Terminals | 12-8 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 0000000 | |
2" | 4 | 1 | 3 | 3W4P | Single | 30A | Screw Terminals | 12-8 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 4 | 1 | 3 | 3W4P | Three | 30A | Screw Terminals | 12-8 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 220V AC/380V AC and 240V AC/415V AC | 0000000 | 000000 |
2.5" | 3 | 1 | 2 | 2W3P | Single | 60A | Screw Terminals | 8-2 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 8-2 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 00000000 | |
2.5" | 5 | 1 | 4 | 4W5P | Three | 60A | Screw Terminals | 8-2 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 277V AC/480V AC | 0000000 | 00000000 |
IEC Pin-and-Sleeve Connectors
These connectors meet international standards IEC 60309-1 and 60309-2, so they’re compatible with other IEC 60309 devices. They have a nonconductive nylon housing so they’re safer to use than components made of metal. Plugs have a notch that must line up with a keyway in sockets and receptacles when mating. All have a ground pin that is included in the number of wires.
Lever-clamp terminals make installation and maintenance quick and convenient. Lower the lever to secure a wire; lift the lever to disconnect it.
IP44 rated connectors protect against damp environments.
IP67 rated connectors protect against dust and submersion.


2W3P
Male

3W4P
Male

3W4P
Male

3W4P
Male
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Choose a Voltage | Each | |
Rated IP44 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1.3" | 3 | 1 | 2 | 2W3P | Single | 20A | Screw Terminals | 14-12 | 0.32"-0.55" | 0° to 120° | 125V AC | 000000000 | 000000 |
1.8" | 3 | 1 | 2 | 2W3P | Single | 30A | Screw Terminals | 10-8 | 0.45"-0.68" | 0° to 120° | 125V AC | 000000000 | 00000 |
1.8" | 4 | 1 | 3 | 3W4P | Three | 30A | Screw Terminals | 10-8 | 0.49"-0.76" | 0° to 120° | 600V AC | 000000000 | 00000 |
2" | 4 | 1 | 3 | 3W4P | Three | 20A | Screw Terminals | 16-12 | 0.33"-0.55" | -10° to 120° | 00000000 | 00000 | |
2.3" | 4 | 1 | 3 | 3W4P | Three | 30A | Screw Terminals | 14-8 | 0.49"-0.76" | -10° to 120° | 00000000 | 00000 | |
Rated IP67 | |||||||||||||
1.957" | 4 | 1 | 3 | 3W4P | Three | 30A | Lever-Clamp Terminals | 10-8 | 0.63"-1.05" | -40° to 165° | 000000000 | 000000 | |
2.421" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 6-4 | 1.05"-1.45" | -40° to 165° | 000000000 | 000000 | |
2.795" | 4 | 1 | 3 | 3W4P | Three | 100A | Screw Terminals | 4-1 | 0.91"-1.68" | -40° to 165° | 000000000 | 000000 |


2W3P
Female

3W4P
Female

3W4P
Female

3W4P
Female
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Choose a Voltage | Each | |
Rated IP44 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1.3" | 3 | 1 | 2 | 2W3P | Single | 20A | Screw Terminals | 16-12 | 0.32"-0.55" | 0° to 120° | 125V AC | 000000000 | 000000 |
1.5" | 4 | 1 | 3 | 3W4P | Three | 20A | Screw Terminals | 16-12 | 0.33"-0.55" | 0° to 120° | 600V AC | 000000000 | 00000 |
1.8" | 3 | 1 | 2 | 2W3P | Single | 30A | Screw Terminals | 10-8 | 0.45"-0.68" | 0° to 120° | 125V AC | 000000000 | 00000 |
1.8" | 4 | 1 | 3 | 3W4P | Three | 30A | Screw Terminals | 10-8 | 0.49"-0.76" | 0° to 120° | 600V AC | 000000000 | 00000 |
2" | 4 | 1 | 3 | 3W4P | Three | 20A | Screw Terminals | 16-12 | 0.33"-0.55" | -10° to 120° | 00000000 | 00000 | |
2.3" | 4 | 1 | 3 | 3W4P | Three | 30A | Screw Terminals | 14-8 | 0.49"-0.76" | -10° to 120° | 00000000 | 00000 | |
Rated IP67 | |||||||||||||
1.85" | 4 | 1 | 3 | 3W4P | Three | 30A | Lever-Clamp Terminals | 10-8 | 0.63"-1.05" | -40° to 165° | 000000000 | 000000 | |
2.362" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 6-4 | 1.05"-1.45" | -40° to 165° | 000000000 | 000000 | |
2.795" | 4 | 1 | 3 | 3W4P | Three | 100A | Screw Terminals | 4-1 | 0.91"-1.68" | -40° to 165° | 000000000 | 000000 |


3W4P
Female
20 ft. Cable Lead | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | Wire Lead Gauge | Temp. Range, °F | Voltage | Each | |
Rated IP67 | ||||||||||||
3" | 4 | 1 | 3 | 3W4P | Three | 100A | Wire Leads | 2 | 0° to 120° | 480V AC | 000000000 | 000000000 |


3W4P
Female

3W4P
Female
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | Temp. Range, °F | Choose a Voltage | Each | |
Rated IP67 | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2.362" | 4 | 1 | 3 | 3W4P | Three | 30A | Lever-Clamp Terminals | 12-8 | -40° to 165° | 000000000 | 0000000 | |
2.362" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 8-2 | -40° to 165° | 000000000 | 000000 | |
2.795" | 4 | 1 | 3 | 3W4P | Three | 100A | Screw Terminals | 4-1/0 | -40° to 165° | 000000000 | 000000 |