    DIN-Rail Mount Touch-Safe Screw Terminal Relays

    Image of Product. Front orientation. Contains Annotated. Relays. DIN-Rail Mount Touch-Safe Screw Terminal Relays.
    Quickly and safely mount these relays on 35 mm DIN rail (also known as DIN 3). IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits.
    3 Circuits Controlled and 4 Circuits Controlled—Relays that control 3 and 4 circuits are built to IEC dimensional standards and are often called IEC contactors.
    12 Terminals—Relays with 12 terminals let you attach the control circuit onto the side that works best for your setup, which reduces the amount of wire you need.
    Control
    hp @
    Switching Voltage
    No. of
    Terminals
    Input Voltage
    Power
    Current,
    mA
    Switching Current @
    Voltage (Load Type)
    Max. Switching
    Voltage, V AC
    Single Phase
    Three Phase
    Ht.
    Wd.
    Dp.
    Each
    2 Circuits Controlled with 2 Off—DPST-NO
    624V AC, 24V DC2 VA25 amp @ 240V AC (Resistive)2403/4 hp @ 120V AC
    2 hp @ 240V AC
    3.5"0.7"2.4"6366N11000000
    6120V AC, 120V DC2 VA25 amp @ 240V AC (Resistive)2403/4 hp @ 120V AC
    2 hp @ 240V AC
    3.5"0.7"2.4"6366N1200000
     
    3 Circuits Controlled with 3 Off—3PST-NO
     
    With 1 Auxiliary Contact—1 Off
    1024V AC4 VA6 amp @ 600V AC (Full)
    20 amp @ 600V AC (Resistive)
    6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    5 hp @ 600V AC
    2.3"1.7"2.2"70255K61100000
    10120V AC4 VA6 amp @ 600V AC (Full)
    20 amp @ 600V AC (Resistive)
    6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    5 hp @ 600V AC
    2.3"1.7"2.2"70255K61200000
    10240V AC4 VA6 amp @ 600V AC (Full)
    20 amp @ 600V AC (Resistive)
    6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    5 hp @ 600V AC
    2.3"1.7"2.2"70255K61300000
    1024V DC3.2 W6 amp @ 600V AC (Full)
    20 amp @ 600V AC (Resistive)
    6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    5 hp @ 600V AC
    2.3"1.7"2.2"70255K1700000
    1224V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K32100000
    1224V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K33100000
    1224V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    3 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K341000000
    12120V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K32200000
    12120V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K33200000
    12120V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    3 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K342000000
    12240V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K32300000
    12240V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K33300000
    12240V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    3 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K343000000
    1224V DC5.4 W11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.9"70255K42000000
    1224V DC5.4 W17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.9"70255K43000000
    1224V DC5.4 W17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    3 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.9"70255K44000000
     
    With 1 Auxiliary Contact—1 On
    1024V AC4 VA6 amp @ 600V AC (Full)
    20 amp @ 600V AC (Resistive)
    6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    5 hp @ 600V AC
    2.3"1.7"2.2"70255K62100000
    10120V AC4 VA6 amp @ 600V AC (Full)
    20 amp @ 600V AC (Resistive)
    6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    5 hp @ 600V AC
    2.3"1.7"2.2"70255K62200000
    10240V AC4 VA6 amp @ 600V AC (Full)
    20 amp @ 600V AC (Resistive)
    6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    5 hp @ 600V AC
    2.3"1.7"2.2"70255K62300000
    1024V DC3.2 W6 amp @ 600V AC (Full)
    20 amp @ 600V AC (Resistive)
    6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    5 hp @ 600V AC
    2.3"1.7"2.2"70255K1800000
    1224V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K35100000
    1224V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K36100000
    1224V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    3 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K371000000
    12120V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K35200000
    12120V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K36200000
    12120V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    3 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K372000000
    12240V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K35300000
    12240V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K36300000
    12240V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    3 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K373000000
    1224V DC5.4 W11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.9"70255K45000000
    1224V DC5.4 W17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.9"70255K46000000
    1224V DC5.4 W17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    3 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.9"70255K47000000
     
    4 Circuits Controlled with 2 Off and 2 On—4PST-2NO/2NC
    1024V DC13310 amp @ 600V AC6002.3"1.7"2.2"7230K93000000
     
    4 Circuits Controlled with 3 Off and 1 On—4PST-3NO/1NC
    1024V DC13310 amp @ 600V AC6002.3"1.7"2.2"7230K92000000
     
    4 Circuits Controlled with 4 Off—4PST-NO
    1024V AC12510 amp @ 600V AC6002.3"1.7"2.2"7230K89100000
    10120V AC2510 amp @ 600V AC6002.3"1.7"2.2"7230K89200000
    10240V AC12.510 amp @ 600V AC6002.3"1.7"2.2"7230K89300000
    1024V DC13310 amp @ 600V AC6002.3"1.7"2.2"7230K91000000
    1224V AC6.5 VA9 amp @ 600V AC (Full)
    25 amp @ 600V AC (Resistive)
    6003/4 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    7 1/2 hp @ 600V AC
    3.2"1.8"3.2"70255K65100000
    1224V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K391000000
    1224V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K551000000
    1224V AC6.5 VA22 amp @ 600V AC (Full)
    45 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    5 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    20 hp @ 600V AC
    3.5"2.4"3.5"70255K411000000
    1224V AC6.5 VA32 amp @ 600V AC (Full)
    55 amp @ 600V AC (Resistive)
    6003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    15 hp @ 240V AC
    30 hp @ 480V AC
    30 hp @ 600V AC
    3.5"2.4"3.5"70255K271000000
    12120V AC6.5 VA9 amp @ 600V AC (Full)
    25 amp @ 600V AC (Resistive)
    6003/4 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    7 1/2 hp @ 600V AC
    3.2"1.8"3.2"70255K65200000
    12120V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K392000000
    12120V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K552000000
    12120V AC6.5 VA22 amp @ 600V AC (Full)
    45 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    5 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    20 hp @ 600V AC
    3.5"2.4"3.5"70255K412000000
    12120V AC6.5 VA32 amp @ 600V AC (Full)
    55 amp @ 600V AC (Resistive)
    6003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    15 hp @ 240V AC
    30 hp @ 480V AC
    30 hp @ 600V AC
    3.5"2.4"3.5"70255K272000000
    12240V AC6.5 VA9 amp @ 600V AC (Full)
    25 amp @ 600V AC (Resistive)
    6003/4 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    7 1/2 hp @ 600V AC
    3.2"1.8"3.2"70255K65300000
    12240V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K393000000
    12240V AC6.5 VA17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.2"70255K553000000
    12240V AC6.5 VA22 amp @ 600V AC (Full)
    45 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    5 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    20 hp @ 600V AC
    3.5"2.4"3.5"70255K413000000
    12240V AC6.5 VA32 amp @ 600V AC (Full)
    55 amp @ 600V AC (Resistive)
    6003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    15 hp @ 240V AC
    30 hp @ 480V AC
    30 hp @ 600V AC
    3.5"2.4"3.5"70255K273000000
    1224V DC5.4 W9 amp @ 600V AC (Full)
    25 amp @ 600V AC (Resistive)
    6003/4 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    7 1/2 hp @ 600V AC
    3.2"1.8"3.9"70255K28000000
    1224V DC5.4 W17 amp @ 600V AC (Full)
    32 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    3.2"1.8"3.9"70255K49000000
    1224V DC5.4 W22 amp @ 600V AC (Full)
    45 amp @ 600V AC (Resistive)
    6002 hp @ 120V AC
    5 hp @ 240V AC
    7 1/2 hp @ 240V AC
    15 hp @ 480V AC
    20 hp @ 600V AC
    3.5"2.4"4.2"70255K66000000
    1224V DC5.4 W32 amp @ 600V AC (Full)
    55 amp @ 600V AC (Resistive)
    6003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    15 hp @ 240V AC
    30 hp @ 480V AC
    30 hp @ 600V AC
    3.5"2.4"4.2"70255K38000000
     
    Accessories and Replacements for Relays

    Safety Relays

    Receive signals from safety monitoring relays or controllers to switch devices off and on because of a system failure. Also known as force-guided or mechanically linked contacts, the interlocking opposing contacts on these relays cannot be open or closed at the same time. To keep your system from receiving false switching signals, the interlocking opposing contact must remain open even if a contact welds closed.
    IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. These relays have been tested to safety standards that can help you achieve your system's PL (performance level) and SIL (safety integrity level). Choose a relay with a PL and SIL rating to meet the needs of your system. Higher ratings indicate greater safety protection. As your system becomes more complex, you generally require a higher safety protection level. Mount them to 35mm DIN rail (also known as DIN 3 Rail).
    SIL 2, PLd Max. System Safety Rating—DIN-Rail Mount
    Image of Product. Bottom orientation. Contains Annotated. Safety Relays. Safety Relays, SIL 2, PLd Max. System Safety Rating—DIN-Rail Mount.
    Relays that meet SIL 2 are tested for applications with a probability of failure of 0.1% to 1%. They’re often used for emergency shutdowns, and fire, gas, and overpressure detection.
    No. of
    Terminals
    Input
    Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw-Terminal Wire Connection
     
    2 Circuits Controlled with 1 Off and 1 On—DPST-1NO/1NC
    8120V AC96 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N112000000
    824V DC386 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N11300000
     
    3 Circuits Controlled with 2 Off and 1 On—3PST-2NO/1NC
    824V DC2610 amp @ 240V AC2503.5"0.7"2.4"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N11100000
     
    4 Circuits Controlled with 2 Off and 2 On—4PST-2NO/2NC
    12120V AC106 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N114000000
    1224V DC426 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N115000000
     
    4 Circuits Controlled with 3 Off and 1 On—4PST-3NO/1NC
    12120V AC106 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N116000000
    1224V DC426 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N117000000
     
    6 Circuits Controlled with 4 Off and 2 On—6PDT-4NO/2NC
    16120V AC106 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N118000000
    1624V DC426 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N119000000
     
    6 Circuits Controlled with 5 Off and 1 On—6PDT-5NO/1NC
    1624V DC426 amp @ 240V AC2503.4"0.9"3.9"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N121000000
     
    SIL 3, PLe Max. System Safety Rating—DIN-Rail Mount
    Image of Product. Bottom orientation. Contains Annotated. Safety Relays. Safety Relays, SIL 3, PLe Max. System Safety Rating—DIN-Rail Mount.
    Relays that meet SIL 3 are tested for applications with a probability of failure of 0.01% to 0.1% and are used for preventing fires, explosions, or toxic releases.
    Mirror Auxiliary Contacts—Relays with mirror auxiliary contacts have contacts that are normally closed and cannot be open at the same time as a normally open main contact.
    Nondetachable Auxiliary Contacts—Relays with nondetachable contacts have auxiliary contacts that won’t separate from the relay if there is shock or vibration.
    Self-Monitoring Circuitry—When a failure is detected, relays with self-monitoring circuitry signal the controller to remove power and prevent restarting until the issue is resolved.
    No. of
    Terminals
    Input Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Features
    Each
    Spring-Clamp-Terminal Wire Connection
     
    3 Circuits Controlled with 3 Off—3PST-NO
    1824V AC, 24V DC55 amp @ 120V AC2301 On
    3.9"0.9"4.8"Interlocked Opposing Contacts, LED Indicator, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N1220000000
     
    SIL 3, PLe, CAT IV, 600V Max. System Safety Rating—DIN-Rail and Surface Mount
    Image of Product. Front orientation. Contains Annotated. Safety Relays. Safety Relays, SIL 3, PLe, CAT IV, 600V Max. System Safety Rating—DIN-Rail and Surface Mount.
    Relays that meet SIL 3 are tested for applications with a probability of failure of 0.01% to 0.1% and are used for preventing fires, explosions, or toxic releases.
    Relays that meet CAT 4 withstand circuit surges in electrical applications up to 600V.
    Mirror Auxiliary Contacts—Relays with mirror auxiliary contacts have contacts that are normally closed and cannot be open at the same time as a normally open main contact.
    Nondetachable Auxiliary Contacts—Relays with nondetachable contacts have auxiliary contacts that won’t separate from the relay if there is shock or vibration.
    Self-Monitoring Circuitry—When a failure is detected, relays with self-monitoring circuitry signal the controller to remove power and prevent restarting until the issue is resolved.
    hp @
    Switching Voltage
    No. of
    Terminals
    Input
    Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Single Phase
    Three Phase
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw-Terminal Wire Connection
     
    3 Circuits Controlled with 3 Off—3PST-NO
    18120V AC27 amp @ 400V AC6001/4 hp @ 120V AC
    1 hp @ 240V AC
    2 hp @ 240V AC
    3 hp @ 480V AC
    5 hp @ 600V AC
    2 Off and 3 On2.7"1.8"4.6"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N110000000
    18120V AC29 amp @ 400V AC6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    7 1/2 hp @ 600V AC
    2 Off and 3 On2.7"1.8"4.6"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N12000000
    18120V AC212 amp @ 400V AC6001 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC
    10 hp @ 480V AC
    10 hp @ 600V AC
    2 Off and 3 On2.7"1.8"4.6"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N13000000
    18120V AC518 amp @ 400V AC6002 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    2 Off and 3 On3.4"1.8"5.5"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N14000000
    18120V AC525 amp @ 400V AC6002 hp @ 120V AC
    5 hp @ 240V AC
    10 hp @ 240V AC
    15 hp @ 480V AC
    20 hp @ 600V AC
    2 Off and 3 On3.4"1.8"5.5"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N19000000
    1824V DC318 amp @ 400V AC6002 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    10 hp @ 480V AC
    15 hp @ 600V AC
    2 Off and 3 On3.4"1.8"5.5"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N18000000
    1824V DC325 amp @ 400V AC6002 hp @ 120V AC
    5 hp @ 240V AC
    10 hp @ 240V AC
    15 hp @ 480V AC
    20 hp @ 600V AC
    2 Off and 3 On3.4"1.8"5.5"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N21000000
    1824V DC127 amp @ 400V AC6001/4 hp @ 120V AC
    1 hp @ 240V AC
    2 hp @ 240V AC
    3 hp @ 480V AC
    5 hp @ 600V AC
    2 Off and 3 On2.7"1.8"4.6"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N15000000
    1824V DC189 amp @ 400V AC6001/2 hp @ 120V AC
    1 1/2 hp @ 240V AC
    3 hp @ 240V AC
    5 hp @ 480V AC
    7 1/2 hp @ 600V AC
    2 Off and 3 On2.7"1.8"4.6"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N16000000
    1824V DC1812 amp @ 400V AC6001 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC
    10 hp @ 480V AC
    10 hp @ 600V AC
    2 Off and 3 On2.7"1.8"4.6"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N17000000
     

    Motor Starters

    Image of Product. Front orientation. Motor Starters. Motor Starters .
    Provide on/off control for a motor and protect it from overloads. These starters shut off the motor if current exceeds the full-load current rating. All have an adjustable overload relay that allows you to set the exact overload current you need.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
    Auxiliary Contact Switch Starting Position—Starters with auxiliary contacts can send a signal or connect to another device, such as an alarm or indicating light.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage
    Electrical Phase
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters
    20 to 10024V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"2.2"DIN Rail35IEC 609477603K17700000007603K2980000007603K299000000
    20 to 100120V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"2.2"DIN Rail35IEC 609477603K1690000007603K298000007603K29900000
    20 to 100200V AC/240V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"2.2"DIN Rail35IEC 609477603K1760000007603K298000007603K29900000
    20 to 10024V DCSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"2.2"DIN Rail35IEC 609477603K1780000007603K298000007603K29900000
     
    Motor Starters with 1 Auxiliary Contact—1 Off
    1 to 524V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1380000007603K296000007603K29700000
    1 to 5120V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1360000007603K296000007603K29700000
    1 to 5200V AC/240V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1370000007603K296000007603K29700000
    1 to 5480V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1460000007603K296000007603K29700000
    1 to 524V DCSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1390000007603K296000007603K29700000
    4 to 2024V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1490000007603K296000007603K29700000
    4 to 20120V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1470000007603K296000007603K29700000
    4 to 20200V AC/240V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1480000007603K296000007603K29700000
    4 to 20480V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1570000007603K296000007603K29700000
    4 to 2024V DCSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1560000007603K296000007603K29700000
    9 to 4524V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"1.8"DIN Rail35IEC 609477603K1660000007603K296000007603K29700000
    9 to 45120V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"1.8"DIN Rail35IEC 609477603K1580000007603K296000007603K29700000
    9 to 45200V AC/240V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"1.8"DIN Rail35IEC 609477603K1590000007603K296000007603K29700000
    9 to 4524V DCSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"1.8"DIN Rail35IEC 609477603K1670000007603K296000007603K29700000
    20 to 100480V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"2.2"DIN Rail35IEC 609477603K1790000007603K298000007603K29900000
     

    Machine-Guard Safety Relays

    Image of Product. Relay. Front orientation. Contains Annotated. Safety Relays. Machine-Guard Safety Relays.

    Relay

    The interlocked opposing contacts won't close at the same time, so these relays are suitable for safety applications such as machine guarding. The screw terminals are recessed to prevent accidental contact with live connections. Mount them on 35 mm DIN rail (also known as DIN 3 rail) or flat surfaces. These relays are built to IEC dimensional standards.
    No. of
    Terminals
    Input Voltage,
    V AC
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Mechanical
    Life Cycles
    Ht.
    Wd.
    Dp.
    Features
    Each
    4 Circuits Controlled with 2 Off and 2 On—4PST-2NO/2NC
    102412510 amp @ 600V AC60020,000,0002.3"1.7"2.2"Interlocked Opposing Contacts, Recessed Terminals7230K871000000
    101202510 amp @ 600V AC60020,000,0002.3"1.7"2.2"Interlocked Opposing Contacts, Recessed Terminals7230K87200000
    1024012.510 amp @ 600V AC60020,000,0002.3"1.7"2.2"Interlocked Opposing Contacts, Recessed Terminals7230K87300000
     
    4 Circuits Controlled with 3 Off and 1 On—4PST-3NO/1NC
    102412510 amp @ 600V AC60020,000,0002.3"1.7"2.2"Interlocked Opposing Contacts, Recessed Terminals7230K88100000
    101202510 amp @ 600V AC60020,000,0002.3"1.7"2.2"Interlocked Opposing Contacts, Recessed Terminals7230K88200000
    1024012.510 amp @ 600V AC60020,000,0002.3"1.7"2.2"Interlocked Opposing Contacts, Recessed Terminals7230K88300000
     
    Auxiliary Contacts

    Reversing Motor Starters

    Image of Product. Front orientation. Motor Starters. Reversing Motor Starters .
    Use these starters with motors that run forward and backward, such as motors for conveyor belts. They provide on/off control and protect motors from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage
    Electrical Phase
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    20 to 10024V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"4.4"DIN Rail35IEC 609477636K2170000000007603K2980000007603K299000000
    20 to 100120V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"4.4"DIN Rail35IEC 609477636K199000000007603K298000007603K29900000
    20 to 100200V AC/240V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"4.4"DIN Rail35IEC 609477636K216000000007603K298000007603K29900000
    20 to 100480V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"4.4"DIN Rail35IEC 609477636K219000000007603K298000007603K29900000
    20 to 10024V DCSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"4.4"DIN Rail35IEC 609477636K218000000007603K298000007603K29900000
     
    Motor Starters with 3 Auxiliary Contacts—2 Off, 1 On
    1 to 524V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1680000007603K296000007603K29700000
    1 to 5120V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1660000007603K296000007603K29700000
    1 to 5200V AC/240V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1670000007603K296000007603K29700000
    1 to 5480V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1760000007603K296000007603K29700000
    1 to 524V DCSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1690000007603K296000007603K29700000
    4 to 2024V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1790000007603K296000007603K29700000
    4 to 20120V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1770000007603K296000007603K29700000
    4 to 20200V AC/240V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1780000007603K296000007603K29700000
    4 to 20480V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1870000007603K296000007603K29700000
    4 to 2024V DCSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1860000007603K296000007603K29700000
    9 to 4524V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"3.6"DIN Rail35IEC 609477636K196000000007603K296000007603K29700000
    9 to 45120V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"3.6"DIN Rail35IEC 609477636K188000000007603K296000007603K29700000
    9 to 45200V AC/240V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"3.6"DIN Rail35IEC 609477636K189000000007603K296000007603K29700000
    9 to 45480V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"3.6"DIN Rail35IEC 609477636K198000000007603K296000007603K29700000
    9 to 4524V DCSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"3.6"DIN Rail35IEC 609477636K197000000007603K296000007603K29700000
     

    Manual Motor Starters

    Image of Product. Front orientation. Motor Starters. Manual Motor Starters .
    Image of Product. Front orientation. Electrical Enclosures. Manual Motor Starters .

    Enclosures

    with On/Off

    Lever

    Provide on/off control for a motor and protect it from overloads. These starters shut off the motor if current exceeds the full-load current rating. The adjustable overload relay allows you to set the exact overload current you need. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
    Motor Starters
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Conduit
    Straights
    Enclosures with
    On/Off Lever
    Overload Current,
    amp
    Switching
    Voltage, V AC
    Electrical Phase
    No. of
    Poles
    Ht.
    Wd.
    Wire Connection
    UL File
    No.
    Each
    Each
    Each
    Each
    1 to 1.6600Single (1/10 hp @ 240V AC)
    Three (3/4 hp @ 480V AC)
    Three (3/4 hp @ 600V AC)
    33.5"1.77"Screw-Clamp TerminalE3450036559K11700000006559K1160000007537K20000006559K1150000000
    1.6 to 2.5600Single (1/6 hp @ 240V AC)
    Three (1/2 hp @ 240V AC)
    Three (1 hp @ 480V AC)
    Three (1 1/2 hp @ 600V AC)
    33.5"1.77"Screw-Clamp TerminalE3450036559K1180000006559K116000007537K2000006559K115000000
    2.5 to 4600Single (1/8 hp @ 120V AC)
    Single (1/3 hp @ 240V AC)
    Three (1 hp @ 240V AC)
    Three (2 hp @ 480V AC)
    Three (3 hp @ 600V AC)
    33.5"1.77"Screw-Clamp TerminalE3450036559K1190000006559K116000007537K2000006559K115000000
    4 to 6.3600Single (1/4 hp @ 120V AC)
    Single (1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 240V AC)
    Three (3 hp @ 480V AC)
    Three (5 hp @ 600V AC)
    33.5"1.77"Screw-Clamp TerminalE3450036559K120000006559K116000007537K2000006559K115000000
    6.3 to 10600Single (1/2 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    Three (5 hp @ 480V AC)
    Three (7 1/2 hp @ 600V AC)
    33.5"1.77"Screw-Clamp TerminalE3450036559K1210000006559K116000007537K2000006559K115000000
    8 to 12600Single (1/2 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    Three (7 1/2 hp @ 480V AC)
    Three (10 hp @ 600V AC)
    33.85"1.77"Screw-Clamp TerminalE3450036559K1220000006559K116000007537K2000006559K115000000
    10 to 16600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    Three (10 hp @ 600V AC)
    33.85"1.77"Screw-Clamp TerminalE3450036559K1230000006559K116000007537K2000006559K115000000
    16 to 20600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    Three (15 hp @ 600V AC)
    33.85"1.77"Screw-Clamp TerminalE3450036559K1240000006559K116000007537K2000006559K115000000
    20 to 25600Single (2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    Three (15 hp @ 480V AC)
    Three (20 hp @ 600V AC)
    33.85"1.77"Screw-Clamp TerminalE3450036559K1250000006559K116000007537K2000006559K115000000

    Interface Safety Relays

    Image of Specification. Front orientation. Contains Annotated. Safety Relays. Interface Safety Relays.
    These relays pair the transmission reliability of an interface relay with the fail-safe operation of a safety relay. Use them to communicate signals to devices like motors or sensors. They have interlocking contacts—also known as force-guided or mechanically linked contacts—so opposing contacts won't close at the same time. This minimizes the chance of arcing, so electricity won't jump across the contacts and interfere with your relay or system. They also have an interface that isolates input and output circuits to prevent damage from voltage spikes, reduce signal interference, and amplify signal. Mount them on 35 mm DIN rail (also known as DIN 3 rail). The relays disconnect from the socket for quick replacement.
    LED Indicator—Relays with LED indicator light up when the relay is on, so you’ll know it’s wired correctly and can tell at a glance whether it’s on or off.
    Safety Relays
    Replacement
    Safety Relays
    No. of
    Terminals
    Input Voltage,
    V DC
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    hp @ Switching
    Voltage
    Mechanical
    Life Cycles
    Ht.
    Wd.
    Dp.
    Features
    Each
    Each
    2 Circuits Controlled with 1 Off and 1 On—DPST-1NO/1NC
    612633 amp @ 240V AC/24V DC250V AC, 125V DC10,000,0001.1"0.5"1.1"Interlocked Opposing Contacts, LED Indicator8722N120000008722N13000000
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    824298 amp @ 240V AC250V AC1/2 hp @ 230V AC10,000,0003.1"0.6"2.4"Interlocked Opposing Contacts8722N11000006253N1100000
     

    Enclosed Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Motor Starters.
    The NEMA 4X rated enclosure protects these starters from corrosion and washdowns. They provide on/off control for a motor and protect it from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage
    Electrical Phase
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    1 to 524V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K18900000007603K2960000007603K297000000
    1 to 5120V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1860000007603K296000007603K29700000
    1 to 5200V AC/240V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1870000007603K296000007603K29700000
    1 to 5480V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1880000007603K296000007603K29700000
    1 to 524V DCSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1960000007603K296000007603K29700000
    4 to 2024V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2360000007603K296000007603K29700000
    4 to 20120V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1970000007603K296000007603K29700000
    4 to 20200V AC/240V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1980000007603K296000007603K29700000
    4 to 20480V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1990000007603K296000007603K29700000
    4 to 2024V DCSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2370000007603K296000007603K29700000
    9 to 4524V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2670000007603K296000007603K29700000
    9 to 45120V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2380000007603K296000007603K29700000
    9 to 45200V AC/240V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2390000007603K296000007603K29700000
    9 to 45480V ACSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2660000007603K296000007603K29700000
    9 to 4524V DCSingle (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2680000007603K296000007603K29700000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    20 to 10024V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    11.7"9.3"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K278000000007603K298000007603K29900000
    20 to 100200V AC/240V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    11.7"9.3"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K276000000007603K298000007603K29900000
    20 to 100480V ACSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    11.7"9.3"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K277000000007603K298000007603K29900000
    20 to 10024V DCSingle (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    11.7"9.3"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K279000000007603K298000007603K29900000
     

    Enclosed Reversing Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Reversing Motor Starters.
    Rated NEMA 4X, these enclosed starters are protected from corrosion and washdowns. Use them with motors that run forward and backward, such as motors for conveyor belts. They provide on/off control and protect motors from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload
    Current, amp
    Input Voltage
    Electrical Phase
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 3 Auxiliary Contacts—2 Off, 1 On
    1 to 524V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K22900000007603K2960000007603K297000000
    1 to 5200V AC/240V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2270000007603K296000007603K29700000
    1 to 5480V ACSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2280000007603K296000007603K29700000
    1 to 524V DCSingle (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2360000007603K296000007603K29700000
    4 to 2024V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2460000007603K296000007603K29700000
    4 to 20120V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2370000007603K296000007603K29700000
    4 to 20200V AC/240V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2380000007603K296000007603K29700000
    4 to 20480V ACSingle (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2390000007603K296000007603K29700000
     