McMaster-Carr logo
    Filter by
    Control Communication Protocol
    Industrial Info Snippet
    Electrical Connection
    Number of Device Ports
    Number of Outputs
    Color
    Mounting Location
    Number of Inputs
    Component
    Connection End Type
    System of Measurement
    Depth
    DFARS Specialty Metals
    Electrical Socket
    Electrical Socket Number of Poles
    Enclosure Rating
    Industrial Info Compare
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Height
    Maximum Temperature
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Minimum Temperature
    Number of Plugs
    Number of Sockets
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    9 Products

    IO-Link I/O Modules

    Image of System. Components Sold Separately. Front orientation. Contains Annotated. I/O Modules.

    Components Sold Separately

    Create a system of sensors and actuators that you can remotely update, view measurements from, and receive error messages in real time. IO-Link systems minimize downtime by locating issues such as cut cables or dirty sensors quickly. They send only digital signals to your PLC, regardless of whether your sensors and actuators send digital or analog signals. Because these systems send digital signals, they’re more reliable and less prone to data error and signal loss than analog signals. It also means you don't have to use expensive shielded cables since they resist EMI.
    When retrofitting an existing system, you'll need to make sure your PLC can incorporate IO-Link. Check with your PLC manufacturer—most have hardware that allows you to upgrade your PLC to run IO-Link.
    Note: Sockets may have extra holes on their face that are not used.
    Modules
    Image of Product. Front orientation. I/O Modules. Modules, Surface Mount.

    Surface

    Mount

    Modules communicate between your sensors and actuators and your PLC. They are required. Setting memory automatically stores your settings and restores them once your device is back online. This eliminates needing to program a device again when you replace or fix it.
    Surface Mount—Surface mount modules let you mount modules on equipment such as tanks and conveyors. By mounting them on your equipment, you save space in your control cabinet. They use M12 connectors.
    IP66 Enclosure Rating—IP66 rated components withstand washdowns.
    IP67 Enclosure Rating—IP67 rated components can be temporarily submerged in water.
    IP69K Enclosure Rating—IP69K rated components hold up to high-pressure and high-temperature washdowns.
    Enclosure Rating—IP rated components block out dust and withstand some water, so they do not require an enclosure. Ports that are unused must be capped to maintain their rating.
    Input
    Output
    Communication
    Protocol
    No. of Device
    Ports
    Total No. of
    M12 Connections
    Type
    Digital
    Signal
    Voltage,
    V DC
    No.
    of
    Type
    Digital
    Signal
    Voltage,
    V DC
    Current,
    amp
    No.
    of
    Operating
    Voltage, V DC
    Certification
    Each
    Surface Mount
     
    IP66, IP67, IP69K
    IO-Link, EtherNet/IP811DigitalPNP0 to 3016DigitalPNP300.3820 to 30UL Listed, C-UL Listed, CE Marked
    7585N210000000
     
    Converters
    Image of Product. Front orientation. Signal Converters.
    Converters translate analog signals to digital signals, making sensors and actuators IO-Link compatible. They are required to connect analog components to controllers and modules.
    IP67 Enclosure Rating—IP67 rated components can be temporarily submerged in water.
    Input
    Output
    Signal Converter Type
    Total No. of
    M12 Connections
    Signal
    Type
    Digital
    Signal
    Analog Signal
    No.
    of
    Signal Type
    Digital
    Signal
    Analog Signal
    No.
    of
    Certification
    Each
    M12 Plug In
     
    Washdown (IP67)
    Analog to Digital2Analog0V DC to 10V DC2DigitalPNP1UL Listed, C-UL Listed, CE Marked
    7603N520000000
    Analog to Digital to Analog2Analog4 mA to 20 mA1Digital, AnalogPNP4 mA to 20 mA2UL Listed, C-UL Listed, CE Marked
    7603N51000000
    Digital to Analog2DigitalPNP1Analog0V DC to 10V DC2UL Listed, C-UL Listed, CE Marked
    7603N53000000
    Digital to Analog2DigitalPNP1Analog4 mA to 20 mA2UL Listed, C-UL Listed, CE Marked
    7603N54000000
     
    Caps
    Image of Product. Front orientation. Metric Circular Connector Caps. For Plugs.

    For Plugs

    Image of Product. Front orientation. Metric Circular Connector Caps. For Sockets.

    For Sockets

    Protective caps prevent dust and debris from harming M12 connections when they're not in use. They also help maintain IP ratings by covering unused ports.
    Stainless Steel—Stainless steel protective caps have a neoprene gasket, which helps maintain IP69K ratings.
    For
    Thread
    Size
    Location
    Material
    Temp. Range,
    ° F
    Includes
    Each
    For Plugs, For Receptacles
    M12
    ExternalAnodized Aluminum0 to 220Lanyard6897K73000000
    M12
    ExternalStainless Steel0 to 220Lanyard6897K7500000
     
    For Receptacles, For Sockets
    M12
    InternalAnodized Aluminum0 to 2206897K7400000
    M12
    InternalStainless Steel0 to 220Lanyard6897K5900000
     
    back to top