McMaster-Carr logo
    Filter by
    Discharge Pipe Size
    Industrial Info Compare
    Intake Pipe Size
    Industrial Info Compare
    Discharge Connection Port
    Discharge Tube Length
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Intake Tube Adjustability
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    75 Products

    Electric Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps with Nozzle for Fuel, Style A.
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps with Nozzle for Fuel, Style B.

    Style A

    Style B

    Pump fuel in hazardous environments with flammable gases. Pumps are UL listed for Class I, Divisions 1 and 2, Group D.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Style A
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps with Nozzle for Fuel, Style A.
    Style A pumps have a circuit breaker to prevent overload.
    Automatic-Shutoff Nozzle—Pumps with automatic shut-off nozzle turn off when the tank is full.
    Pump Pedestals—Pedestal kit converts your pump from a drum mount to a pedestal mount.
    Drum Pumps
    Pump Pedestals
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Tube
    OD
    Tube Lg.
    Hose
    ID
    Hose
    OD
    Hose Length,
    ft.
    Nozzle Type
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
     
    Aluminum Housing
    121510-201251/81.54.82 NPT1 7/16"22" to 40"3/4"1 5/32"12Automatic Shutoff0000000000000000000000000000
    121510-201251/81.55.52 NPT1 7/16"22" to 40"3/4"1 5/32"12Manual Shutoff00000000000000000000000000
     
    Style B
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps with Nozzle for Fuel, Style B.
    Style B pumps have a metering nozzle that registers total volume up to 99,999.9 gallons. Lock with a padlock (not included). A bypass valve prevents pressure buildup when the nozzle is closed.
    Anti-Siphon Kits—Anti-siphon kit prevents reverse flow with a vacuum breaker and includes all hose, fittings, and seals required for installation.
    Pump Pedestals—Pedestal kit converts your pump from a drum mount to a pedestal mount.
    Drum Pumps
    Anti-Siphon Kits
    Pump Pedestals
    Temp.,
    ° F
    Discharge
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Intake Pipe
    Connection
    Hose
    ID
    Hose
    OD
    Hose Length,
    ft.
    Nozzle Type
    Max. Shackle
    Dia.
    Each
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
     
    Cast Iron Housing
    202210-401501/35.5102 NPT1 1/4 Female NPT3/4"1 1/8"12Metering
    Lockable
    Manual Shutoff
    3/8"00000000000000000000000000000000000000000000
     

    Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
    48.55514300-402101/25.341 mm1 5/8"39"Pump BodyBarbed1"MaleC-UL Listed
    UL Listed
    00000000000000000000000000000000
     
    Pump Replacement Parts

    Continuous-Flow Drum Pumps for Fuel

    Rotate the handle to dispense a continuous flow of liquid. These pumps are rated for use with Class I and II flammable and combustible fuels.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    With Hose and Nozzle
    Image of Product. Front orientation. Drum Pumps. Continuous-Flow Drum Pumps for Fuel, With Hose and Nozzle.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Hose
    OD
    Hose Length,
    ft.
    Features
    Each
    Each
    12.815 to 55319-151502 NPTDrum Connector1"20" to 35"5/8"8Bonding and Grounding Wires, Nozzle Hanger, Strainer, Vacuum Breaker000000000000000000000000000
     
    Replacements for Drum Pumps
    With Removable Spout
    Image of Product. Front orientation. Drum Pumps. Continuous-Flow Drum Pumps for Fuel, With Removable Spout.
    Pumps with removable spout allow you to replace the spout with a 1" ID discharge tube for transfer applications.
    Drum Pumps
    Connectors
    Temp.
    Intake
    Discharge
    (Spout End)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Pipe
    Size
    Thread
    Type
    Gender
    Features
    Each
    Each
    1155420Not Rated3002 NPTDrum Connector3/4"22" to 40"3/4
    NPT
    MaleDrip Pan, Internal Flame Arrester, Strainer000000000000000000000000000
     
    Replacements for Drum Pumps
    With Removable Spout and Hose and Nozzle
    Image of Product. Front orientation. Drum Pumps. Continuous-Flow Drum Pumps for Fuel, With Removable Spout and Hose and Nozzle.
    Pumps with removable spout allow you to replace the spout with a 1" ID discharge tube for transfer applications.
    Drum Pumps
    Connectors
    Temp.
    Intake
    Discharge (Hose
    and Nozzle)
    Discharge
    (Spout End)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Hose
    OD
    Hose Lg.,
    ft.
    Pipe
    Size
    Thread
    Type
    Gender
    Features
    Each
    Each
    1155420Not Rated3002 NPTDrum Connector3/4"22" to 40"3/4"83/4
    NPT
    MaleInternal Flame Arrester, Nozzle Hanger, Strainer, Vacuum Breaker000000000000000000000000000
     
    Replacements for Drum Pumps

    Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style B.
    Image of Product. Style C (Shown with Connector). Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style C.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style D.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style E.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style F.

    Style B

    Style C (Shown

    with Connector)

    Style D

    Style E

    Style F

    Push the plunger to pump water, cleaners, and chemicals.
    Style B
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style B.
    Style B are for thin liquids with a maximum viscosity of 700 or 750 centipoise.
    Drum Pumps
    Replacement
    Connectors
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    Pipe
    Size
    Each
    PVC Piston
    857504012070 mmDrum Connector1/2"13"Tube End7/16"5/8"22"PVC
    000000000000002 NPT00000000000000
     
    Style C
    Image of Product. Style C (Shown with Connector). Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style C.

    Style C (Shown

    with Connector)

    Style C are rated for liquids up to 2,500 centipoise. They are often used as hand pumps and do not come with a connector. To attach them to a container, select an optional connector.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    CSM Piston
    55 to 152,500351201/2"18"Tube End7/16"9/16"9"PVC
    0000000000000
     
    Connectors
    Style D
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style D.
    Style D are rated for liquids up to 2,500 centipoise.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    CSM Piston
    652,5003512061 mmDrum Connector1/2"14 1/2"Tube End7/16"9/16"36"PVC
    0000000000000
    652,5003512063 mmDrum Connector1/2"14 1/2"Tube End7/16"9/16"36"PVC
    000000000000
    652,5003512070 mmDrum Connector1/2"14 1/2"Tube End7/16"9/16"36"PVC
    000000000000
     
    Style E
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style E.
    Style E are rated for liquids up to 2,500 centipoise.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    CSM Piston
    85 to 302,500351202 NPTDrum Connector1/2"18"Tube End7/16"9/16"48"PVC
    0000000000000
     
    Viton® Fluoroelastomer Piston
    55 to 552,500351202 NPTDrum Connector9/16"36"Tube End7/16"9/16"9"PVC
    000000000000
     
    Style F
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style F.
    Style F are rated for liquids up to 2,500 centipoise.
    Drum Pumps
    Connectors
    Replacement
    Connectors
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    Connection
    Each
    Pipe
    Size
    Each
    Viton® Fluoroelastomer Piston
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Polyethylene000000000000002 5/8"-5 Buttress00000000000002 NPT0000000000000
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Polyethylene00000000000002 5/8"-5 Buttress0000000000002 NPT000000000000
    28552,500351202"Drum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Polyethylene00000000000002 5/8"-5 Buttress0000000000002 NPT000000000000
    28552,500351202"Drum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Polyethylene000000000000002 5/8"-5 Buttress0000000000002 NPT000000000000
     

    Battery-Operated Siphon Drum Pumps

    Image of Product. Front orientation. Drum Pumps. Battery-Operated Siphon Drum Pumps, For Kerosene.

    For

    Kerosene

    Quickly generate suction with battery power.
    Temp.
    Intake
    Discharge
    Batteries
    Drum Pump
    Type
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Included
    Size
    No.
    Required
    Each
    For Kerosene
    Siphon1.853Not Rated1401 13/16"15/16"12 1/2"Tube End1/2"9/16"24"NoD20000000000000
     

    Drum Pumps for Diesel Exhaust Fluid

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Diesel Exhaust Fluid.
    Made with polypropylene components, these pumps withstand highly corrosive diesel exhaust fluid (DEF) while preventing it from crystallizing. Intake tube is not included.
    Temp.,
    ° F
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    For Intake
    Tube OD
    Discharge
    Location
    Connection
    Hose
    OD
    Hose Length,
    ft.
    Hose
    Material
    Drum Pump
    Type
    Nozzle Type
    Each
    1155 to 2751.5351102"Drum Connector1"Hose and NozzleBarbed3/4"12EPDM
    Lever HandleAutomatic Shutoff0000000000000
     

    Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals.
    Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
    316 Stainless Steel Housing—Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
    Temp.
    Intake
    Discharge
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    120V AC—Single Phase—Hardwire
     
    316 Stainless Steel Housing
    1815551,000Not Rated1751 1/39.12 NPT1 1/2"39"1"1 1/4"72"NEC Class I Divisions 1, 2 Group D
    IP55
    0000000000000000
     

    Foot-Operated Drum Pumps for Water and Oil

    Image of Product. Front orientation. Drum Pumps. Foot-Operated Drum Pumps for Water and Oil.
    The foot pedal allows hands-free operation. These pumps have a telescoping intake tube that works with containers of different heights.
    Temp.,
    ° F
    Intake
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Spout
    Type
    Drum Pump
    Type
    Each
    655500351001 1/8" to 2 3/4"Drum Connector1/2"19" to 35"Spout EndFixedPedal00000000000000
     

    Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. ZoomedIn view. Drum Pumps. Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel.
    These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. They have an automatic shut-off nozzle so they turn off when the tank is full. Lock the nozzle with a padlock (not included).
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Discharge (Hose
    and Nozzle)
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Includes
    Intake Pipe
    Connection
    Hose
    ID
    Hose Lg.,
    ft.
    Nozzle Type
    Max. Shackle
    Dia.
    Each
    12V DC—With Thermal Overload Protection
    252010-201254/1035152 NPT18-ft. Battery Cable, Drum Connector1 Female NPT1"18Automatic Shutoff
    Lockable
    5/16"0000000000000000
     

    High-Pressure Air-Powered Drum Pumps for Fuel and Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. High-Pressure Air-Powered Drum Pumps for Fuel and Flammable Liquid.
    Use these pumps with fuel and flammable liquids, such as acetone, ethanol, and gasoline. They handle nearly twice the amount of pressure as other air-powered drum pumps to move high-viscosity liquids. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    4557,500402000 to 150102 NPTDrum Connector1/4 Female NPT2 1/8"33 11/16"Pump BodyThreaded3/4 Female NPT0000000000000000
     

    Aluminum Long-Life Air-Powered Drum Pumps for Fuel

    Image of Product. Front orientation. Drum Pumps. Aluminum Long-Life Air-Powered Drum Pumps for Fuel.
    Pump fuel such as gasoline, kerosene, and diesel fuel. Also known as diaphragm pumps, these pumps have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include balls, O-rings, and diaphragms.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    28558,00040210100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT39"Pump BodyThreaded3/4 Female NPT0000000000000000000000000000000
     

    Aluminum Long-Life Air-Powered Drum Pumps for Oil

    Image of Product. Front orientation. Drum Pumps. Aluminum Long-Life Air-Powered Drum Pumps for Oil.
    Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Pump Repair Kits—Repair kits include balls, O-rings, and diaphragms.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    Buna-N Diaphragm
    31558,00010180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT39"Pump BodyThreaded3/4 Female NPT0000000000000000000000000000000
     

    Battery-Operated Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. Drum Pumps. Battery-Operated Drum Pumps with Nozzle for Fuel.
    Image of Product. Pump with Metering Nozzle. Front orientation. Metering Nozzle. Battery-Operated Drum Pumps with Nozzle for Fuel.

    Pump with Metering Nozzle

    Operating on a 12-volt battery, these pumps transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Metering Nozzle—Pumps with metering nozzle record total volume up to 99,999.9 gallons.
    Temp.,
    ° F
    Intake
    Discharge (Hose
    and Nozzle)
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Hose
    ID
    Hose Lg.,
    ft.
    Nozzle Type
    Each
    12V DC—Single Phase—With Thermal Overload Protection
    151230-151501/42082 NPT18-ft. Battery Cable, Drum Connector1"20" to 34 3/4"3/4"12Metering
    Manual Shutoff
    00000000000000
    151230-151501/42082 NPT18-ft. Battery Cable, Drum Connector1"20" to 34 3/4"3/4"12Lockable
    Manual Shutoff
    0000000000000
     

    Easy-Stroke Drum Pumps for Fuel

    Image of Product. Front orientation. Drum Pumps. Easy-Stroke Drum Pumps for Fuel.
    For low-effort dispensing, a lever handle maximizes output with each stroke. The handle delivers fluid on both the forward and backward strokes to quickly move drum contents. Lock the handle with a padlock (not included). Flow is reversible.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include components such as gaskets, valve assemblies, and piston rings.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge (Pump Body)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Connection
    Pipe
    Size
    Gender
    Thread
    Type
    Spout
    Type
    Drum Pump Type
    Max. Shackle
    Dia.
    Certification
    Each
    Each
    2615 to 55319-151502 NPT1"20" to 35"Spout End
    Pump Body
    Threaded3/4
    MaleNPT
    RemovableLockable Lever Handle1/4"UL Listed
    000000000000000000000000000
     
    Pump Intake Tubes

    Easy-Stroke Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. Drum Pumps. Easy-Stroke Drum Pumps with Nozzle for Fuel.
    A nozzle and hose allow you to dispense directly into your container. The lever handle maximizes output with each stroke for low-effort dispensing. The handle delivers fluid on both the forward and backward strokes to quickly move drum contents. Lock the handle with a padlock (not included). Flow is reversible.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include components such as gaskets, valve assemblies, and piston rings.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Hose
    OD
    Hose Length,
    ft.
    Hose
    Material
    Drum Pump Type
    Max. Shackle
    Dia.
    Certification
    Each
    Each
    2615 to 55319-151502 NPT1"20" to 35"Hose and Nozzle5/8"8Buna-N
    Lockable Lever Handle1/4"UL Listed
    000000000000000000000000000
     
    Accessories and Replacements for Drum Pumps

    PVDF Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. PVDF Long-Life Air-Powered Drum Pumps for Chemicals.
    A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Pump Repair Kits—Repair kits include O-rings, valves, and diaphragms.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    13553,00040210100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT0000000000000000000000000000000
     

    Quick-Dispensing Drum Pumps for Fuel

    Image of Product. Front orientation. Drum Pumps. Quick-Dispensing Drum Pumps for Fuel.
    A lever handle delivers fluid on both the forward and backward strokes for faster dispensing than other drum pumps. The handle can be mounted with the knob above or below the pump body. Lock the handle with a padlock (not included).
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include a gasket, a piston ring, O-rings, and valves.
    Drum Pumps
    Pump Repair Kits
    Temp.
    Intake
    Discharge (Pump Body)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    For Discharge
    Hose ID
    Connection
    Pipe
    Size
    Gender
    Thread
    Type
    Spout
    Type
    Drum Pump
    Type
    Max. Shackle
    Dia.
    Each
    Each
    3255410Not Rated702 NPTDrum Connector1 5/16"34"Spout End
    Pump Body
    3/4"Threaded3/4
    FemaleNPT
    RemovableLever Handle1/4"000000000000000000000000000
     
    Connectors

    Stainless Steel Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. Stainless Steel Long-Life Air-Powered Drum Pumps for Chemicals.
    A stainless steel construction allows these pumps to be used with aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Pump Repair Kits—Repair kits include balls, O-rings, and diaphragms.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    28558,00040210100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT39"Pump BodyThreaded3/4 Female NPT0000000000000000000000000000000
     

    Nondrip Drum Pumps for Fuel and Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Nondrip Drum Pumps for Fuel and Flammable Liquid.
    Image of Product. Front orientation. Pump Tap Kits. Nondrip Drum Pumps for Fuel and Flammable Liquid.

    Tap Kits

    Eliminate leaks and waste with a faucet-style nondrip nozzle that quickly starts and stops flow. Pressurize your container with a few pumps of the plunger handle, and use the one-touch nozzle to manage flow. Hold down the nozzle for intermittent dispensing, open the nozzle fully for continuous flow, and close the nozzle to stop flow entirely.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    NFPA 30 18.4.4.1—NFPA approved pumps are rated for use with Class I and II flammable and combustible liquids such as fuels, alcohols, and acetone.
    Tap Kits—Remote tap kits extend your pump's reach for transferring liquid to tanks, mixers, and sprayers. They include a splash guard, a 6-ft. PVC tube, and hardware.
    Drum Pumps
    Tap Kits
    Temp.,
    ° F
    Intake
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Drum Pump
    Type
    Nozzle
    Type
    Features
    Flammability
    Rating
    Each
    Each
    4.52 to 55270351102 NPTDrum Connector5/8"40"NozzlePlungerNondrip0000000000000000000000000000
    4.52 to 55270351102 NPTDrum Connector5/8"40"NozzlePlungerNondripBonding and Grounding WiresNFPA 30 18.4.4.1
    0000000000000———0
     

    Air-Powered Drum Pumps for Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Air-Powered Drum Pumps for Flammable Liquid.
    These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Features
    Each
    26551,100-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"39"Pump BodyBarbed1"MaleCE Marked
    Bonding and Grounding Wires, Hanger0000000000000000
    26551,100-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"47"Pump BodyBarbed1"MaleCE Marked
    Bonding and Grounding Wires, Hanger000000000000000
    53551,000-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"39"Pump BodyBarbed1"MaleCE Marked
    Bonding and Grounding Wires, Hanger000000000000000
    53551,000-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"47"Pump BodyBarbed1"MaleCE Marked
    Bonding and Grounding Wires, Hanger000000000000000
     
    Pump Replacement Parts
    back to top