McMaster-Carr logo
    Filter by
    System of Measurement
    Push-Button Shape
    Panel Cutout Diameter
    Reset Type
    Actuator Color
    Message Color
    Number of Terminals
    Number of Circuits Controlled
    Switching Current
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Switch Starting Position
    Industrial Info Compare
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    36 Products
    About Electrical Switches
    industrial info icon

    Choose a switch with the right trigger type, number of inputs, and control functions to power your equipment.

    Aluminum Enclosed Push-Button-Actuator Emergency Stop Switches

    These aluminum switches are rated NEMA 4, NEMA 13, and IP66 for protection from washdowns and oil/coolant spraying. Housed in a yellow enclosure for quick identification, they immediately cut power with a single push. They meet EN 60947-5-1 for compliance with European machine directives for emergency stop applications. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. UL listed and CSA certified, they also meet American and Canadian safety standards. The front of these switches is UL recognized.
    Key Reset (2 Keys Included)
    Image of Product. Front orientation. Emergency Stop Switches. Aluminum Enclosed Push-Button-Actuator Emergency Stop Switches, Key Reset (2 Keys Included).
    Key reset switches stop you from accidentally resetting the switch before you’ve dealt with the emergency. They’re keyed alike, meaning they all open with the same key.
    Mounting
    No. of
    Buttons
    Actuator Color (Switch
    Designation)
    No. of Circuits
    Controlled per Button
    Switch Starting
    Position
    Switch
    Action
    No. of Terminals
    per Button
    Switching Current
    @ Voltage
    Dia.
    Conduit Knockout
    Size
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Screw-Terminal Wire Connection—600V AC/600V DC Max. Voltage
    1Red (SPST-NC)11 On
    Maintained
    26 amp @ 120V AC
    2.5 amp @ 24V DC
    1 9/16"PG-16
    No43/16"6785K1110000000
    1Red (DPST-NC)22 On
    Maintained
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    1 9/16"PG-16
    No43/16"6785K112000000
     
    Replacements for Emergency Stop Switches
    Illuminated Pull Reset
    Image of Product. Front orientation. Emergency Stop Switches. Aluminum Enclosed Push-Button-Actuator Emergency Stop Switches, Illuminated Pull Reset.
    Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    Mounting
    No. of
    Buttons
    Actuator Color (Switch
    Designation)
    No. of Circuits
    Controlled per Button
    Bulb Voltage
    Switch Starting
    Position
    Switch
    Action
    No. of Terminals
    per Button
    Switching Current
    @ Voltage
    Dia.
    Conduit Knockout
    Size
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Screw-Terminal Wire Connection—600V AC/600V DC Max. Voltage
    1Red (SPST-NC)124V AC/24V DC1 On
    Maintained
    26 amp @ 120V AC
    2.5 amp @ 24V DC
    1 9/16"PG-16
    No43/16"6785K1130000000
    1Red (SPST-NC)1120V AC1 On
    Maintained
    26 amp @ 120V AC
    2.5 amp @ 24V DC
    1 9/16"PG-16
    No43/16"6785K115000000
    1Red (SPST-NC)1240V AC1 On
    Maintained
    26 amp @ 120V AC
    2.5 amp @ 24V DC
    1 9/16"PG-16
    No43/16"6785K117000000
    1Red (DPST-NC)224V AC/24V DC2 On
    Maintained
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    1 9/16"PG-16
    No43/16"6785K114000000
    1Red (DPST-NC)2120V AC2 On
    Maintained
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    1 9/16"PG-16
    No43/16"6785K116000000
    1Red (DPST-NC)2240V AC2 On
    Maintained
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    1 9/16"PG-16
    No43/16"6785K118000000
     
    Replacement Blocks

    16 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Key Reset. Front orientation. Emergency Stop Switches. 16 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Key Reset.

    Key Reset

    Immediately cut power with a single push. These switches meet EN 418 for compliance with European machine directives for emergency stop applications. They're rated NEMA 4, 13, and IP65 for protection from washdowns and oil/coolant spraying.
    Key Reset—Key reset switches are keyed alike, so if you buy multiple switches they will all reset with the same key.
    Number of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Actuator
    Style
    Actuator
    Color
    Switch
    Designation
    Number of
    Terminals
    Switching Current
    @ Voltage
    Max. Voltage,
    V AC
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure Rating
    No. of Keys
    Included
    Each
    Plastic Actuator With Screw-Terminal Wire Connection
     
    Key Reset
    11 On
    Maintained
    Push ButtonRedSPST-NC
    22.5 amp @ 125V AC
    6 amp @ 24V DC
    2501 1/16"1 11/16"1IP65
    NEMA 4
    NEMA 13
    265645K620000000
     
    Accessories for Emergency Stop Switches

    Plastic Enclosed Push-Button-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Plastic Enclosed Push-Button-Actuator Emergency Stop Switches, Key Reset (2 Keys Included).

    Key Reset (2 Keys

    Included)

    Made of yellow polycarbonate plastic, these enclosed switches are easy to see and resist dents, chips, and cracks. They are more corrosion resistant than aluminum enclosed switches and withstand washdowns and oil/coolant spraying. Mount them to a wall or attach a cord grip to position them at your workstation. They have positive force contacts that will open a circuit when actuated, even if a spring fails or the contacts stick. A single push will immediately cut power.
    The switches can be reset by manually pulling, turning or unlocking them by key.
    Key Reset—Key reset switches are keyed alike, so if you buy multiple switches they will all reset with the same key.
    Emergency Stop Switches
    Replacement
    Actuators
    Mounting
    No. of
    Buttons
    Actuator
    Color
    No. of Circuits
    Controlled per Button
    Switch Starting
    Position
    Switch
    Action
    No. of Terminals
    per Button
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Conduit
    Trade Size
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Specs. Met
    Each
    Each
    Screw-Clamp-Terminal Wire Connection
     
    Key Reset (2 Keys Included)
    1Red11 On
    Maintained
    2SPST-NC
    6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1/2
    No23/16"EN 418, IEC 60947-5-1, IEC 60947-5-5, UL 5086785K2500000006785K98000000
    1Red21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1/2
    No23/16"EN 418, UL 5086785K930000006785K9800000
    1Red22 On
    Maintained
    4DPST-NC
    6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1/2
    No23/16"EN 418, IEC 60947-5-1, IEC 60947-5-5, UL 5086785K260000006785K9800000
     
    Replacement Blocks

    Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Key Reset. Front orientation. Emergency Stop Switches. Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Key Reset, Not Illuminated.

    Key Reset

    Immediately cut power with a single push. These switches meet EN 418 for compliance with European machine directives for emergency stop applications. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. They include enough contact blocks to control the number of circuits listed.
    Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    IP66 Enclosure Rating, NEMA 4 Enclosure Rating, and NEMA 13 Enclosure Rating—Key reset, pull reset, illuminated pull reset, and turn reset switches are rated NEMA 4, 13, and IP66. Contact blocks for these switches are rated IP20.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure Rating
    Each
    Key Reset with Screw-Terminal Wire Connection—Not Illuminated
    11 On
    Maintained
    2SPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K269000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K27200000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K27100000
     
    Accessories for Emergency Stop Switches

    Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Key Reset.

    Not Illuminated

    Key Reset

    Immediately cut power with a single push. These switches meet EN 418 for compliance with European machine directives for emergency stop applications. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. They're rated IP66, IP69K, NEMA 3S, NEMA 4X, and NEMA 13, and are UL and C-UL Recognized Components. Switches include enough contact blocks to control the number of circuits listed. Contact blocks are rated IP20 and are UL and C-UL Listed.
    Key Reset—Key reset switches are keyed alike, so if you buy multiple switches they will all reset with the same key.
    Emergency Stop Switches
    Replacement
    Actuators
    Number of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Actuator
    Style
    Actuator
    Color
    Switch
    Designation
    Number of
    Terminals
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure Rating
    No. of Keys
    Included
    Mfr.
    Each
    Each
    Plastic Actuator and Actuator Base With Screw-Terminal Wire Connection—Not Illuminated
     
    Key Reset
    11 On
    Maintained
    Push ButtonRedSPST-NC
    26 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 1/4"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    2BACO Controls6741K47000000———0
    11 On
    Maintained
    Push ButtonRedSPST-NC
    26 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    2BACO Controls6741K49000006785K98000000
    22 On
    Maintained
    Push ButtonRedDPST-NC
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 1/4"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    2BACO Controls6741K4800000———0
    22 On
    Maintained
    Push ButtonRedDPST-NC
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    2BACO Controls6741K51000006785K9800000
     
    Accessories for Emergency Stop Switches

    22 mm Panel-Mount Build-Your-Own Plastic Push-Button Switches

    Choose an actuator and contact block to make your own switch. Actuators are rated NEMA 3S, 4X and 13 for protection from dust, outdoor environments, corrosion, oil, and washdowns. They mount into standard panel cutouts. Use legend plates (not included) to label switches. BACO Controls switches are only compatible with BACO manufactured legend plates.
    Push-Button Actuators
    Image of Product. Front orientation. Push-Button Actuators. 22 mm Panel-Mount Build-Your-Own Plastic Push-Button Switches, Triangle Mushroom Push Button with Key Reset.

    Triangle Mushroom

    Push Button with

    Key Reset

    Push-button actuators are best for applications where you need quick starts and stops.
    Switch Mounting Tools—Mounting tools make it easier to install switches in crowded panels.
    Push-Button Actuators
    Switch
    Mounting Tools
    Switch
    Action
    Dia.
    For Max. No. of
    Contact Blocks
    No. of Keys
    Included
    Key Removal
    Position
    Key
    No.
    Enclosure Rating
    Certification
    Specs.
    Met
    Mfr.
    Actuator
    Color
    Each
    Each
    Triangle Mushroom Push Button with Key Reset
    Maintained
    1 5/8"62Center455IK05, IP66, NEMA 3S, NEMA 4X, NEMA 13
    C-UL Recognized Component, UL Recognized Component
    UL 508BACO ControlsRed7544K960000007550K95000000
     

    Tablet Holders with Emergency Stop Switch

    Image of ProductInUse. Pivoting Handle (Back View). Back orientation. Emergency Stop Switches. Tablet Holders with Emergency Stop Switch.
    Image of ProductInUse. Holder with Tablet Installed (Not Included). Front orientation. Emergency Stop Switches. Tablet Holders with Emergency Stop Switch.

    Pivoting Handle (Back View)

    Holder with Tablet Installed

    (Not Included)

    Image of Product. Holder. Front orientation. Emergency Stop Switches. Tablet Holders with Emergency Stop Switch.
    Image of Product. Front orientation. Tablet Holder Bracket Kits.

    Holder

    Tablet Holder

    Bracket Kits

    Halt machinery in an instant with these tablet holders. They equip your tablet with safety switches that meet IEC and EN standards, so you can safely move around your equipment while teaching robots or monitoring production lines and conveyor systems.
    The emergency stop switch on the front of the holder illuminates when the switch is enabled. There is also a deadman switch on the back of the holder that controls machinery when you lightly press and hold it in the middle position. If the switch is released or pressed down all the way, it stops the machine.
    Pivot the handle to hold a tablet vertically or horizontally, while keeping the switches in a comfortable position for either hand. The adjustable mounting bracket secures a variety of tablet sizes. Connect your tablet to the USB port to charge during use.
    Tablet Holder Bracket Kits—Tablet holder bracket kits enlarge the bracket to hold tablets with thick covers and protectors.
    Emergency Stop Switches
    Tablet Holder Bracket Kits for 7/16"
    to 11/16" Device Depth
    Tablet Holder Bracket Kits for 3/4"
    to 15/16" Device Depth
    For Diag.
    Screen Size
    For Device
    Dp.
    Input Voltage,
    V DC
    Cord Lg.,
    ft.
    Each
    Each
    Each
    8" to 11"3/8"60168750N11100000008750N1120000008750N113000000
    back to top