Filter by
High-Force Linear Solenoids
Pull Solenoid
Push Solenoid
High-force solenoids draw more power than our other open-frame solenoids, so they can deliver higher force. They also have a laminated rod that minimizes friction during operation.
Pull solenoids exert force when the rod retracts.
Push solenoids exert force when the rod extends.
For technical drawings and 3-D models, click on a part number.
Intermittent Use
Length | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Voltage | Power Draw, Watts | On/Off Time, Minutes | Wd. | Ht. | Rod Dia. (R) | Each | |
For AC Voltage, 60 Hz | ||||||||||||
Pull | ||||||||||||
1" | 2.3" | 3" | 3" | 60 | 120V AC | 70 | 2.5/22.5 | 1 1/2" | 1 1/2" | 0.36" | 000000 | 0000000 |
1" | 2.7" | 3.4" | 3.4" | 195 | 120V AC | 228 | 3/27 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 00000 |
1" | 2.7" | 3.4" | 3.4" | 195 | 240V AC | 228 | 3/27 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 00000 |
Push | ||||||||||||
0.82" | 3" | 3" | 3" | 60 | 120V AC | 70 | 2.5/22.5 | 1 1/2" | 1 1/2" | 0.13" | 000000 | 000000 |
1" | 3 1/2" | 3.5" | 3.5" | 195 | 120V AC | 228 | 3/27 | 1 7/8" | 2 1/8" | 0.19" | 0000000 | 000000 |
Continuous Use
Length | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Voltage | Power Draw, Watts | Wd. | Ht. | Rod Dia. (R) | Each | |
For AC Voltage, 60 Hz | |||||||||||
Pull | |||||||||||
1" | 2.3" | 3" | 3" | 30 | 120V AC | 20 | 1 1/2" | 1 1/2" | 0.36" | 000000 | 0000000 |
1" | 2.7" | 3.4" | 3.4" | 105 | 120V AC | 49 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 00000 |
1" | 2.7" | 3.4" | 3.4" | 105 | 240V AC | 49 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 00000 |
Push | |||||||||||
0.82" | 3" | 3" | 3" | 30 | 120V AC | 20 | 1 1/2" | 1 1/2" | 0.13" | 0000000 | 000000 |
1" | 3 1/2" | 3.5" | 3.5" | 105 | 120V AC | 49 | 1 7/8" | 2 1/8" | 0.19" | 0000000 | 000000 |