About Industry Designation for Cable Insulation
More
About Wire and Cable
More
Power Cords










Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
SVT cords are ultra-flexible and as pliable as vacuum cleaner cords. They withstand repeated winding.
SJEOW cords have an oil- and water-resistant insulation.
The insulation on SJTW cords resists water.
Use SJT cords in dry or damp locations.
SRDT cords are for use with high-current equipment, such as ranges and dryers.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Wd. | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × Wire Leads | ||||||||||||
16 | 13 | 125V AC | 6 | 0.31" | __ | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
16 | 13 | 125V AC | 6 | 0.32" | __ | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 | 0.31" | __ | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 00000 |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.25" | __ | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 8 | 0.25" | __ | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 0000 |
18 | 10 | 125V AC | 9 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000000 | 00000 |
18 | 10 | 125V AC | 9 1/2 | 0.25" | __ | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 3 | 0.33" | __ | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 0000 |
16 | 13 | 125V AC | 6 | 0.33" | __ | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 0000 |
16 | 13 | 125V AC | 6 | 0.33" | __ | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
16 | 13 | 125V AC | 9 | 0.33" | __ | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 | 0.33" | __ | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 6 | 0.37" | __ | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 0000 |
14 | 15 | 125V AC | 6 | 0.38" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000000 | 0000 |
14 | 15 | 125V AC | 6 | 0.38" | __ | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 | 0.37" | __ | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 | 0.38" | __ | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
90° Elbow NEMA 5-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 125V AC | 8 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 0000 |
16 | 13 | 125V AC | 8 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 00000 |
14 | 15 | 125V AC | 8 | 0.38" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 00000 |
NEMA 6-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.25" | __ | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
90° Elbow NEMA 10-30 Plug × Spade Terminals | ||||||||||||
10 | 30 | 125V AC/250V AC | 6 | __ | 0.83" | PVC Plastic | SRDT | 0° to 140° | UL Listed | Gray | 00000000 | 00000 |
90° Elbow NEMA 10-50 Plug × Spade Terminals | ||||||||||||
8, 6 | 50 | 125V AC/250V AC | 4 | __ | 1.03" | PVC Plastic | SRDT | 0° to 140° | UL Listed | Gray | 000000000 | 00000 |
8, 6 | 50 | 125V AC/250V AC | 6 | __ | 1.03" | PVC Plastic | SRDT | 0° to 140° | UL Listed | Gray | 00000000 | 00000 |
90° Elbow NEMA 14-30 Plug × Spade Terminals | ||||||||||||
10 | 30 | 125V AC/250V AC | 4 | 0.67" | __ | PVC Plastic | SRDT | 0° to 140° | UL Listed | Black | 000000000 | 00000 |
10 | 30 | 125V AC/250V AC | 6 | 0.67" | __ | PVC Plastic | SRDT | 0° to 140° | UL Listed | Black | 00000000 | 00000 |
90° Elbow NEMA 14-50 Plug × Spade Terminals | ||||||||||||
8, 6 | 50 | 125V AC/250V AC | 6 | 0.8" | __ | PVC Plastic | SRDT | 0° to 140° | UL Listed | Black | 00000000 | 00000 |
Light Duty Power Cords






Designed for indoor applications, these cords are often used to power appliances.
SPT cords have a flat cord shape so they fit in tight spaces. The numbers 1, 2, and 3 indicate the relative thickness of the insulation. SPT-3 is the thickest, so it is less flexible but more durable than -1 and -2 cords.
Use SJT cords in dry or damp locations.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Wd. | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 125V AC | 6 | __ | 0.19" | PVC Plastic | SPT-1 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 00000 |
18 | 10 | 125V AC | 6 | __ | 0.25" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
18 | 10 | 125V AC | 8 | __ | 0.25" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
18 | 10 | 125V AC | 9 | __ | 0.19" | PVC Plastic | SPT-1 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 125V AC | 6 | __ | 0.31" | PVC Plastic | SPT-1 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 6 | __ | 0.31" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
18 | 10 | 125V AC | 6 | __ | 0.38" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 6 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 8 | __ | 0.31" | PVC Plastic | SPT-1 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 8 | __ | 0.31" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
18 | 10 | 125V AC | 8 | __ | 0.38" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 9 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 6 | __ | 0.38" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 00000 |
16 | 13 | 125V AC | 6 | __ | 0.44" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 8 | __ | 0.38" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 00000 |
16 | 13 | 125V AC | 8 | __ | 0.44" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 1/2 | 0.38" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
NEMA 6-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
IEC C14 Plug × Wire Leads | ||||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.33" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
Coiled Power Cords


These self-coiling cords stretch to full length and then return to their retracted length for tangle-free storage. The industry designation is SJEOW, so the insulation resists oil and water.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Retracted Lg., ft. | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
18 | 7 | 125V AC | 1 | 6 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
Sure-Grip Power Cords


Also known as hospital-grade cords, these cords have an extra-tight connection to prevent them from detaching. The plug is marked with a green dot.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 00000 |
16 | 13 | 125V AC | 12 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 00000 |
Appliance Cable

- Use For: Appliances
- Flexible
- Temperature Range:
SPT-1: 0° to 140° F
HPN: 0° to 190° F - Insulation:
SPT-1: PVC Plastic
HPN: Polyethylene Plastic
Also known as zip cord, this cable has wires that can be separated for installation. It’s often used in small appliances and has a flat shape to fit in tight spaces.
SPT-1 cable is often used in lamps and radios.
HPN cable is often used with heating appliances, such as portable heaters and soldering irons.