    110 Products

    Toggle Light Switches

    Image of Product. Front orientation. Light Switches. Toggle Light Switches, Screw-Terminal Wire Connection.

    Screw-Terminal

    Wire Connection

    Your standard light switches—these switches stick out of your mounting surface and flip on and off. They also work with AC motor loads up to 80% of the current rating. All fit standard wall plates (not included).
    No. of Circuits
    Controlled
    No. of
    Terminals
    Switch
    Action
    Switching Current
    @ Voltage
    Wire
    Connection
    Terminal
    Location
    Choose a Color
    Each
    Not Illuminated
    24Maintained
    15 amp @ 120V A/277V ACScrew TerminalBack, SideBrown, Ivory, White7030K33000000
    24Maintained
    20 amp @ 120V AC/277V ACScrew TerminalBack, SideBrown, Ivory, White7030K3600000
    24Maintained
    30 amp @ 120V AC/277V ACScrew TerminalBack, SideBrown, Ivory, White7030K3900000
     
    Lockouts

    Multi-Way Toggle Light Switches

    Image of Product. Front orientation. Light Switches. Multi-Way Toggle Light Switches, Screw-Terminal Wire Connection.

    Screw-Terminal

    Wire Connection

    Often used in large, open workspaces, these switches can be wired on opposite ends of the room to control lights on the same circuit. With a protruding switch, they’re easily flipped on and off. These switches fit standard wall plates (not included).
    4-Way Switch—Use a four-way switch with two three-way switches to control lights from three different locations.
    No. of Circuits
    Controlled
    No. of
    Terminals
    Switch
    Action
    Switching Current
    @ Voltage
    Terminal
    Location
    Mounting
    Location
    Certification
    Choose a Color
    Each
    4-Way Switches with Screw-Terminal Wire Connection
     
    Toggle Switch Actuator—Not Illuminated
    14Maintained
    20 amp @ 120V AC/277V ACBack, SideOutlet BoxUL Listed, CSA Certified
    Brown, Ivory, White7030K51000000
     
    Lockouts

    Pull-Chain Switches

    Image of Product. Front orientation. Pull-Chain Switches.
    Pull the chain to send a switch signal. These switches are commonly used as replacements in lights and fans.
    Wire
    Leads
    Chain
    Lg.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    No.
    of
    Lg.
    Certification
    Each
    Wire Lead Connection
    2"22 On
    Maintained
    4DPST-NC
    6 amp @ 125V AC, 3 amp @ 250V AC2501 1/8"3/4"1 3/8"36"UL Recognized Component
    6969N1100000
     

    Light Dimmers

    Image of Product. Front orientation. Contains Inset. Light Dimmers. Light Dimmers, Toggle Switch Actuator with Mini Slide Dimmer.
    Image of Product. Front orientation. Light Dimmers. Light Dimmers, Rocker Switch Actuator with Slide Dimmer.
    Image of Product. Front orientation. Light Dimmers. Light Dimmers, Rocker Switch Actuator with Mini Slide Dimmer.

    Toggle Switch

    Actuator with Mini

    Slide Dimmer

    Rocker Switch

    Actuator with

    Slide Dimmer

    Rocker Switch Actuator

    with Mini Slide Dimmer

    Adjust the brightness of lights.
    Toggle Switch Actuator with Mini Slide Dimmer, Rocker Switch Actuator with Slide Dimmer, and Rocker Switch Actuator with Mini Slide Dimmer—Slide dimmers include both a switch and a dimmer. Use them to turn lights on and off while maintaining your desired brightness level.
    3-Way Switch—Three-way dimmers let you control the same circuit of lights from two locations, so they’re often used in large, open workspaces. Pair them with a 3-way on/off switch.
    For Bulb Type
    Multi-Way
    Switch Type
    No. of Circuits
    Controlled
    No. of
    Terminals
    Input Voltage,
    V AC
    Wattage
    Wire
    Connection
    Certification
    Color
    Each
    Toggle Switch Actuator with Mini Slide Dimmer
    Incandescent and Halogen or CFL and LED3 Way14120600 W/150 WScrew TerminalUL Listed
    White7083K56000000
     
    Rocker Switch Actuator with Slide Dimmer
    Incandescent and Halogen or CFL and LED3 Way14120600 W/150 WWire LeadsUL Listed
    White7083K5500000
     
    Rocker Switch Actuator with Mini Slide Dimmer
    Incandescent and Halogen or CFL and LED3 Way14120600 W/150 WWire LeadsUL Listed
    White7083K5700000
     

    Smart Light Dimmers

    Image of ProductInUse. Front orientation. Light Dimmers. Smart Light Dimmers.
    Adjust how bright lights are from anywhere. These dimmers use Wi-Fi to sync to a downloadable app on your smartphone or tablet. Use the app to set the brightness, turn lights on and off, and set a lighting schedule. For example, you might set the light to dim during peak sunlight hours. Someone working in the area is still able to turn the brightness up by pressing the top push button on the dimmer. Use up to 20 of these dimmers—even if they’re across different circuits—on the same Wi-Fi network.
    Often used in large, open workspaces, these dimmers can be wired on opposite ends of the room to control the brightness of lights on the same circuit.
    For Bulb Type
    Multi-Way
    Switch Type
    No. of Circuits
    Controlled
    No. of
    Terminals
    Input Voltage,
    V AC
    Wattage
    Wire
    Connection
    Electrical
    Connection
    Operating System Compatibility
    Color
    Each
    Rocker Switch Actuator with Push Button Dimmer
    Incandescent and Halogen or CFL and LED3 Way14120450 W/150 WScrew TerminalWi-FiAndroid 6.0 or Later, iOS 12.0 or Later, watchOS 3.0 or LaterWhite8884N111000000
     

    Vibration-Resistant 22 mm Panel-Mount Lever Switches

    Image of Product. Front orientation. Lever Switches. Vibration-Resistant 22 mm Panel-Mount Lever Switches.
    Prevent accidental actuation from bumps—these switches require you to grip and twist the lever to turn the switch. The contact block and actuator are all one piece, so they won’t separate in high-vibration applications. Install them in a standard panel cutout.
    Lever
    Lg.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    Enclosure Rating
    Certification
    Specs.
    Met
    Each
    2 Positions with Screw Terminals
    1 1/8"21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    0.6 amp @ 120V AC, 0.22 amp @ 125V DC240V AC
    250V DC
    1 1/8"1 11/16"NEMA 3, NEMA 12, IP65
    UL Listed, CSA Certified, CCC Marked, CE Marked
    UL 5086894N12000000
     
    3 Positions with Screw Terminals
    1 1/8"22 Off
    Maintained
    4DPST-NO
    0.6 amp @ 120V AC, 0.22 amp @ 125V DC240V AC
    250V DC
    1 1/8"1 11/16"NEMA 3, NEMA 12, IP65
    UL Listed, CSA Certified, CCC Marked, CE Marked
    UL 5086894N1300000
     

    Outlet-Box-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Outlet-Box-Mount Push-Button-Actuator Emergency Stop Switches.
    Immediately cut power with a single push. The large palm-sized buttons on these switches provide an easy target, so they're easy to use even while wearing gloves. When the button is depressed, the switch latches and can be locked in that position using a lockout or padlock with a 9/32” shackle diameter (not included). All have positive force contacts that will open the circuit when actuated even if a spring fails or the contacts stick. They're rated NEMA 13 and IP65 for protection from oil/coolant spraying and washdowns.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Cover
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Enclosure
    Rating
    Specs. Met
    Certification
    Each
    Plastic Actuator with Screw-Terminal Wire Connection
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    RedYellow6 amp @ 120V AC
    2.2 amp @ 125V DC
    600V AC
    250V DC
    2 1/4"IP65
    NEMA 13
    EN 60947-5-5, IEC 60947-5-5, UL 508CE Marked
    CSA Certified
    CSA-US Certified
    UL Listed
    66185K610000000
     

    Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure that resists denting, chipping, and cracking. Mount them to the wall when you run out of space in an electrical panel.
    Use additional switch power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Two-Circuit Switch with Lockout. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 2 Circuits Controlled, Lockout.

    Two-Circuit

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Photovoltaic—Photovoltaic switches can be used with photovoltaic cells which convert sunlight into electricity.
    Switching
    Current,
    amp
    Voltage,
    V DC
    Switch
    Designation
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure Rating
    Certification
    Each
    Yellow Plastic Housing with Red Actuator
     
    2 Circuits Controlled with Lockout/Photovoltaic
    20800DPST
    9 13/16"6 5/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K720000000
    32800DPST
    11"7 1/2"5/16"Screw TerminalIP66
    IP67
    NEMA 3S
    NEMA 6P
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    6759K73000000
    50800DPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K74000000
    63650DPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K71000000
     
    Labels

    Energy-Saving Panel-Mount Timer Switches

    Image of Product. Front orientation. Timer Switches. Energy-Saving Panel-Mount Timer Switches.
    Push and release the button to activate—no electricity required.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current
    @ Voltage
    Set Time
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    No. of
    Terminals
    Dp. Behind
    Panel
    For Panel
    Cutout Dia.
    For Max.
    Panel Thk.
    Each
    11 Off or 1 On
    10 amp @ 120V AC/240V AC2 sec. to 1 min.1 7/16"1"1 1/2"Tab41 1/16"15/32"3/16"8008K330000000

    Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Key Reset. Front orientation. Emergency Stop Switches. Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Key Reset, Not Illuminated.
    Image of Product. Pull Reset—Illuminated. Front orientation. Emergency Stop Switches. Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Illuminated, Pull Reset.
    Image of Product. Pull Reset with Lockout. Front orientation. Emergency Stop Switches. Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Pull Reset, Lockout, Not Illuminated.

    Key Reset

    Pull

    Reset—Illuminated

    Pull Reset with

    Lockout

    Image of Product. Turn Reset. Front orientation. Emergency Stop Switches. Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Turn Reset.
    Image of Product. Turn Reset—Illuminated. Front orientation. Emergency Stop Switches. Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Turn Reset, Illuminated.

    Turn Reset

    Turn

    Reset—Illuminated

    Immediately cut power with a single push. These switches meet EN 418 for compliance with European machine directives for emergency stop applications. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. They include enough contact blocks to control the number of circuits listed.
    Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    Lockout—Pull reset switches with lockout latch when you depress the button, and can be locked in that position using a padlock with a max. 3/16" shackle diameter. Switches are rated NEMA 13 and IP65.
    IP66 Enclosure Rating, NEMA 4 Enclosure Rating, and NEMA 13 Enclosure Rating—Key reset, pull reset, illuminated pull reset, and turn reset switches are rated NEMA 4, 13, and IP66. Contact blocks for these switches are rated IP20.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure Rating
    Choose a Bulb Voltage
    Each
    Key Reset with Screw-Terminal Wire Connection—Not Illuminated
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K272000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K27100000
     
    Pull Reset with Screw-Terminal Wire Connection—Illuminated
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 3/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K77000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K79000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    2 3/8"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K81000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 3/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K78000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K61000000
     
    Pull Reset with Screw-Terminal Wire Connection and Lockout—Not Illuminated
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    125V DC
    1 9/16"1 13/16"6IP65
    NEMA 13
    6741K67000000
     
    Turn Reset with Screw-Terminal Wire Connection—Not Illuminated
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 3/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K26300000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K26500000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    2 3/8"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K26800000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 3/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K26200000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K26400000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    2 3/8"1 13/16"6IP20
    IP66
    NEMA 4
    NEMA 13
    8382K26700000
     
    Turn Reset with Screw-Terminal Wire Connection—Illuminated
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC8382K2700000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    2 3/8"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    120V AC8382K291000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC8382K2800000
     
    Accessories for Emergency Stop Switches

    30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Immediately cut power with a single push. These switches are rated for protection from low-pressure streams of water and oil/coolant spraying. They have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. Mount them in a standard panel cutout.
    Metal Actuator Base with Screw-Terminal Wire Connection—Not Illuminated
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Pull Reset.
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Twist Reset.

    Pull Reset

    Twist Reset

    Pull Reset—Turn pull switches back on by pulling the button.
    Twist Reset—Turn twist switches back on by twisting the button.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    Dp. Behind
    Panel
    Each
    Pull Reset
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K3460000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 5/8"42 3/4"9235K32000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K347000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 5/8"42 3/4"9235K3000000
     
    Twist Reset
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K339000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K341000000
     
    Accessories and Replacements for Emergency Stop Switches
    Metal Actuator Base with Screw-Terminal Wire Connection and Lockout—Not Illuminated
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Lockout, Pull Reset.

    Pull Reset

    Switches with lockout latch when you depress the button and can be locked in that position using a lockout or padlock with a 9/32" shackle diameter.
    Pull Reset—Turn pull switches back on by pulling the button.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    Dp. Behind
    Panel
    Each
    Pull Reset
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.2 amp @ 125V DC
    600V AC
    150V DC
    2"61 7/8"66185K710000000
     
    Blocks
    Metal Actuator Base with Screw-Terminal Wire Connection—Illuminated
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Illuminated, Pull Reset.

    Pull Reset

    Illuminated switches are visible in low light. They include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    Pull Reset—Turn pull switches back on by pulling the button.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    Dp. Behind
    Panel
    Choose a Bulb Voltage
    Each
    Pull Reset
    11 Off
    Maintained
    4SPST-NO
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"42 1/16"24V AC/24V DC, 120V AC/120V DC9235K360000000
    11 On
    Maintained
    4SPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"42 7/16"24V AC/24V DC, 120V AC/120V DC9235K146000000
    11 On
    Maintained
    4SPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"42 1/16"240V AC/240V DC9235K362000000
     
    Accessories and Replacements for Emergency Stop Switches
    Plastic Actuator Base with Screw-Terminal Wire Connection—Not Illuminated
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Pull Reset.
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Twist Reset.

    Pull Reset

    Twist Reset

    Pull Reset—Turn pull switches back on by pulling the button.
    Twist Reset—Turn twist switches back on by twisting the button.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    Dp. Behind
    Panel
    Each
    Pull Reset
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K3430000000
     
    Twist Reset
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K336000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K337000000
     
    Accessories and Replacements for Emergency Stop Switches

    Harsh Environment Panel-Mount Disconnect Switches

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style B. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style A. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style C. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.

    Style B

    Style A

    Style C

    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP69K Enclosure Rating—Rated IP69K, these switches withstand high-pressure, high-temperature washdowns.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Dia.
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Stainless Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K1120000000
     
    Gray Stainless Steel Housing with Gray Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K113000000
     
    Labels

    Enclosure Door Switches

    Image of Product. Front orientation. Enclosure Door Switches.
    Activate or deactivate fans, lights, and other devices inside your enclosure when you open or close the door. To actuate these switches, push the plunger. They work with most enclosures, since you can slide the housing up to 1 ⅜” to make the switch longer or shorter. Mount screws anywhere along the mounting slots to install.
    1 Off and 1 On Switch Starting Position—1 off and 1 on switches control two devices at the same time—for example, use them to turn a light on and a fan off when you open the door.
    Switching
    For
    Wire
    No. of Circuits
    Controlled
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Max. Voltage,
    V AC
    Ga.
    No.
    of
    Overall
    Lg.
    Enclosure
    Rating
    Certification
    Each
    Plastic Actuator with Wire Leads
     
    1 Off and 1 On Switch Starting Position
    2Momentary
    4DPST-1NO/1NC
    825025016 to 1424 1/4"IP20
    CE Marked
    4497N13000000
     

    Hazardous Location Cable-Pull-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Hazardous Location Cable-Pull-Actuator Emergency Stop Switches.
    Safe to use near ignitable gases and dust, the housing on these switches seals in anything that could ignite flammable material. All are UL listed and CSA certified for use in hazardous locations. Yank the cable anywhere along your line to quickly cut power in emergencies. They have positive-force, snap-open contacts that open a circuit when actuated, even if a spring fails or the contacts stick. The contacts will remain open until you tension the cable and reset the switch. Use the tension indicator to visually confirm that they’re reset correctly.
    Mounting
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Fasteners
    Included
    Hole Dia. (No.
    of Holes)
    Hole Thread Size
    (No. of Holes)
    Features
    Each
    Screw-Terminal Wire Connection
     
    1 Direction (NEMA 4; NEMA 7; NEMA 9; NEMA 13; NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G)
    20022 On
    4DPST-NC
    10 amp @ 600V AC
    10 amp @ 250V DC
    600V AC
    250V DC
    251/2
    No1/4" (2)5/16"-18 (2)Tension Indicator7543N12000000000
     

    Hinge-Actuated Safety Switches

    Image of ProductInUse. Front orientation. Contains Border. Safety Switches. Hinge-Actuated Safety Switches.
    Image of Product. Front orientation. Safety Switches. Hinge-Actuated Safety Switches.
    Replace the hinges on access doors or machine guards with these switches to keep your team safe from active machinery. Also known as interlock switches, they automatically shut off power to your machinery when the door or guard opens. They can be mounted on flat frames or aluminum T-slotted framing. These switches have positive-force, normally-closed contacts that will open a circuit when the switch is actuated, even if a spring fails or the contacts stick. They’re rated IP65 for protection from washdowns.
    Overall
    For Rail
    Ht., mm
    Mounting Hole Ctr.-to-Ctr.
    Wd., mm
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Wire
    Connection
    Conduit Thread
    Size
    Ht.
    Wd.
    Dp.
    Each
    2 Circuits Controlled—2 On
     
    4° Actuation Angle—Aluminum Hinge
    4044Momentary
    4DPST-NC
    2 amp @ 230V ACScrew TerminalM20
    3.62"4.39"1.42"7777K1080000000
     

    Hazardous Location 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Hazardous Location 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches.
    Switches immediately cut power with a single push. Use these switches where ignitable gas and dust may be present. Their contact blocks are explosion proof and UL listed for Class I, Division 2, Groups B, C, and D hazardous locations. All are rated NEMA 4X and IP65 for protection from corrosion and washdowns. They include enough contact blocks to control the number of circuits listed.
    Number of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Actuator
    Style
    Actuator
    Color
    Switch
    Designation
    Number of
    Terminals
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure
    Rating
    Each
    Plastic Actuator and Metal Actuator Base With Screw-Terminal Wire Connection—Not Illuminated
     
    Pull Reset
    21 Off and 1 On
    Maintained
    Push ButtonRedDPST-1NO/1NC
    46 amp @ 120V AC
    5.75 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"2 3/16"2IP65
    NEMA 4X
    1693N10000000
     
    Turn Reset
    21 Off and 1 On
    Maintained
    Push ButtonRedDPST-1NO/1NC
    46 amp @ 120V AC
    5.75 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"2 3/16"2IP65
    NEMA 4X
    1693N2000000
     
    Blocks

    Vibration-Resistant Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Vibration-Resistant Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated.

    Not Illuminated

    A single-piece construction prevents the contact block from separating from the actuator in high-vibration applications. These switches immediately cut power with a single push. They have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. These switches meet American, Canadian, European, and other global safety requirements. They’re rated NEMA 4X, NEMA 13, and IP65 for protection from corrosion, washdowns, and oil/coolant spraying.
    Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    Number of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Actuator
    Style
    Actuator
    Color
    Switch
    Designation
    Number of
    Terminals
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure Rating
    Each
    Plastic Actuator With Screw-Terminal Wire Connection—Not Illuminated
     
    Turn Reset
    21 Off and 1 On
    Maintained
    Push ButtonRedDPST-1NO/1NC
    43 amp @ 220V AC
    1.1 amp @ 110V DC
    600V AC
    600V DC
    1 9/16"1 7/8"1IP65
    NEMA 4X
    NEMA 13
    7480T122000000
    22 On
    Maintained
    Push ButtonRedDPST-NC
    43 amp @ 220V AC
    1.1 amp @ 110V DC
    600V AC
    600V DC
    1 9/16"1 7/8"1IP65
    NEMA 4X
    NEMA 13
    7480T11100000
     
    Legend Plates and Labels

    Cable-Pull-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches, 1 Direction (IP65, NEMA 4).
    Image of Product. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches, 2 Directions (IP67).

    1 Direction (IP65,

    NEMA 4)

    2 Directions (IP67)

    Immediately cut power by pulling a cable. These switches are often used to turn off production lines and material handling systems in an emergency. All have positive-force, snap-open contacts that open a circuit when actuated, even if a spring fails or the contacts stick. The contacts will remain open until you tension the cable and reset the switch.
    2 Directions—Two-direction switches can be used with tension springs (not included) to open contacts and stop machinery if the cable breaks.
    Switch Installation Kits—Accessory kits (sold separately) simplify the installation of a new switch.
    Emergency Stop Switches
    Switch Installation Kits
    Mounting
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage,
    V AC
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Fasteners
    Included
    Hole
    Dia.
    No. of
    Holes
    Each
    Includes
    Each
    Screw-Terminal Wire Connection
     
    1 Direction (IP65, NEMA 4)
    1511 Off and 1 On
    4DPST-1NO/1NC
    10 amp @ 120V AC400181/2
    No1/4"465975K510000000Cable, Clamps, Tension Screws, Thimbles65975K810000000
     
    2 Directions (IP67)
    16521 Off and 1 On
    4DPST-1NO/1NC
    1.1 amp @ 120V AC24053/4
    No5/16"265975K84000000Cable, Clamps, Eyebolts, Tension Screws, Tension Springs65975K94000000
     

    Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Key Reset.
    Image of Product. Front orientation. Emergency Stop Switches. Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Pull Reset.
    Image of Product. Front orientation. Emergency Stop Switches. Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Turn Reset.

    Not Illuminated

    Key Reset

    Not Illuminated

    Pull Reset

    Not Illuminated

    Turn Reset

    Immediately cut power with a single push. These switches meet EN 418 for compliance with European machine directives for emergency stop applications. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. They're rated IP66, IP69K, NEMA 3S, NEMA 4X, and NEMA 13, and are UL and C-UL Recognized Components. Switches include enough contact blocks to control the number of circuits listed. Contact blocks are rated IP20 and are UL and C-UL Listed.
    Key Reset—Key reset switches are keyed alike, so if you buy multiple switches they will all reset with the same key.
    Emergency Stop Switches
    Replacement
    Actuators
    Number of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Actuator
    Style
    Actuator
    Color
    Switch
    Designation
    Number of
    Terminals
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure Rating
    No. of Keys
    Included
    Mfr.
    Each
    Each
    Plastic Actuator and Actuator Base With Screw-Terminal Wire Connection—Not Illuminated
     
    Key Reset
    22 On
    Maintained
    Push ButtonRedDPST-NC
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 1/4"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    2BACO Controls6741K48000000———0
    22 On
    Maintained
    Push ButtonRedDPST-NC
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    2BACO Controls6741K51000006785K98000000
     
    Pull Reset
    22 On
    Maintained
    Push ButtonRedDPST-NC
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 1/4"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    BACO Controls6741K4200000———0
    22 On
    Maintained
    Push ButtonRedDPST-NC
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    BACO Controls6741K44000006741K7300000
     
    Turn Reset
    22 On
    Maintained
    Push ButtonRedDPST-NC
    46 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"6IK05
    IP20
    IP66
    IP69K
    NEMA 3S
    NEMA 4X
    NEMA 13
    BACO Controls6741K46000006785K9900000
     
    Accessories for Emergency Stop Switches

    Frame-Mounted Safety Switches

    Image of ProductInUse. Key Shown Actuating from the Side. Front orientation. Safety Switches. Frame-Mounted Safety Switches.

    Key Shown Actuating from the Side

    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style B.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style C.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style E.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style F.

    Style

    B

    Style C

    Style E

    Style F

    Also known as interlock switches, these ensure the safety of personnel by automatically shutting off power to machinery when an access door opens. Mount the switch to the door frame and mount a key to the door so that the key is inserted into the switch when the door is closed. When the door opens, the key is removed from the switch and the machine shuts down. They’re often used with machine guards for large robots.
    Styles B-F—Style A-G switches have positive-force, normally closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick.
    IP67 Enclosure Rating—IP67 rated switches protect against temporary submersion.
    NEMA 4 Enclosure Rating—NEMA 4 rated switches protect against washdowns.
    NEMA 6 Enclosure Rating—NEMA 6 rated switches protect against both temporary submersion and washdowns.
    Key Included—All switches require an actuator key, but not all include one—check whether you need to pick out a separate actuator key. For some switch styles, you can also select the mounting orientation of the key.
    Housing
    Conduit
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Ht.
    Wd.
    Dp.
    Trade
    Size
    Thread
    Size
    Thread
    Type
    Key
    Included
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts
    B21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    5 amp @ 120V AC, 2 amp @ 24V DC500V AC
    250V DC
    3"1"1.1"1/2
    NPT
    YesIP67, NEMA 6
    65665K320000000
    C21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    10 amp @ 120V AC, 2 amp @ 24V DC250V AC
    24V DC
    3.6"2.1"1.3"1/2
    NPT
    YesIP65, NEMA 4
    65665K13000000
    E21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    8 amp @ 230V AC, 5 amp @ 24V DC400V AC
    24V DC
    4.2"2"1.6"M20
    Metric
    NoIP67
    65665K4300000
    E22 On
    Maintained
    4DPST-NC
    8 amp @ 230V AC, 5 amp @ 24V DC400V AC
    24V DC
    4.2"2"1.6"M20
    Metric
    NoIP67
    65665K2200000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"M20
    Metric
    NoIP67
    65665K112000000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    BSPP
    NoIP67
    65665K111000000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    NPT
    NoIP67
    65665K105000000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"M20
    Metric
    NoIP67
    65665K11300000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    BSPP
    NoIP67
    65665K10800000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    NPT
    NoIP67
    65665K109000000
     
    Actuator Keys