    38 Products

    Noncontact Liquid-Level Transmitters

    Use these transmitters to measure the levels of corrosive, dirty, or sticky liquids without coming into contact with them. They’ll continuously send measurements, so you can monitor status and manage components in your system. Mount at the top of your tank. There should be no tank walls, agitators, or other objects in the path of the transmitter.
    Ultrasonic
    Image of Product. Transmitter. Front orientation. Liquid-Level Transmitters. Noncontact Liquid-Level Transmitters, Ultrasonic.
    Image of Product. Front orientation. Liquid-Level Transmitters. Noncontact Liquid-Level Transmitters, Ultrasonic, Button Interface.

    Transmitter

    Button

    Interface

    Ultrasonic transmitters use high-frequency sound waves and are often used to measure water, wastewater, chemicals, and oil but won’t work on vapors, foam, and other media that’s difficult to measure. The included fob allows you to connect your transmitter to your computer, where you'll download software that guides you through the setup process to make sure you get accurate readings.
    Digital Switch Output—Transmitters with a switch can also signal your controller to turn components on or off when they reach a set level.
    NEMA 6P Enclosure Rating—NEMA 6P rated transmitters protect against dust, weather, washdowns, corrosion, and submersion. IP68 rated transmitters seal out dust and water from temporary submersion.
    Button Interface—Ultrasonic transmitters with a button interface can be set up and calibrated without the fob.
    Overall
    Pipe
    Size
    For Liquid
    Level, ft.
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    Electrical Connection
    Enclosure
    Rating
    Includes
    Features
    Each
    NPT Male Pipe Connection
     
    0-5V DC, 0V-10V DC Signal
    1
    0 to 430 psi @ 70° F2"3 1/4"-30 to 140412 to 24Wire LeadsNEMA 6P
    USB Configuration Fob3407K230000000
     
    4-20 mA Signal
    2
    0 to 19 1/230 psi @ 70° F4 3/8"7"-30 to 14014 to 28Quick-Disconnect TerminalIP68, NEMA 6P
    USB Configuration FobButton Interface3407K17000000
    3
    0 to 3930 psi @ 70° F4 5/8"7"-30 to 14014 to 28Quick-Disconnect TerminalIP68, NEMA 6P
    USB Configuration FobButton Interface3407K1800000000
     
    4 mA to 20 mA Signal with Switch
    1
    0 to 430 psi @ 70° F2"3 1/4"-30 to 140424Wire LeadsNEMA 6P
    USB Configuration Fob3407K11000000
    1
    0 to 9 3/430 psi @ 70° F3"4 3/4"-30 to 140424Wire LeadsNEMA 6P
    USB Configuration Fob3407K14000000
    2
    1 1/2 to 4 3/430 psi @ 70° F2 3/4"4"-30 to 140414 to 28Wire LeadsIP68, NEMA 6P
    USB Configuration Fob3407K15000000
    2
    4 to 9 3/430 psi @ 70° F2 3/4"4"-30 to 140414 to 28Wire LeadsIP68, NEMA 6P
    USB Configuration Fob3407K16000000
     
    Replacement USB Adapters for Ultrasonic Transmitters
    Radar
    Image of Product. Front orientation. Liquid-Level Transmitters. Noncontact Liquid-Level Transmitters, Radar.
    Radar transmitters use high-frequency electromagnetic waves and are best for liquids that are tricky to measure because they work even if there’s condensation, foam, or other difficult conditions. They also measure the level of liquids with solids and small solids. In addition to the traditional 4-20 mA output, these transmitters can also send measurements to your Android smartphone or tablet using Bluetooth. There’s an app you can use to set up your transmitter and calibrate it for your system.
    Overall
    Pipe
    Size
    For Liquid
    Level, ft.
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    Electrical
    Connection
    Enclosure
    Rating
    Data
    Connection
    Communication
    Protocol
    Each
    NPT Male Pipe Connection
     
    4-20 mA Signal
    1 1/2
    0 to 4540 psi @ 70° F4"4 1/4"-40 to 1751518 to 36Wire LeadsIP68
    BluetoothHART5354K21000000000
     

    Float Liquid-Level Transmitters

    Image of Product. Front orientation. Liquid-Level Transmitters. Float Liquid-Level Transmitters.
    Easy to set up and use, these transmitters measure liquid levels using a standard float gauge. They continuously send measurements to a receiving device, such as a programmable logic controller, so you can monitor status and manage components in your system.
    Pipe
    Overall
    For Tank
    Dp.
    Size
    Type
    Gender
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    For Container Type
    Electrical
    Connection
    Certification
    Each
    4 mA to 20 mA Output Current
     
    Polypropylene Float
    19"1 1/2
    NPT
    Male100 psi @ 70° F1 7/8"21"-40 to 220212 to 30Closed Tank, Open TankWire LeadsC-UL Recognized Component, CE Marked, UL Recognized Component
    3966N110000000
     
    316 Stainless Steel Float
    24"2
    NPT
    Male200 psi @ 70° F2 3/8"27"-40 to 220212 to 30Closed Tank, Open TankWire LeadsC-UL Recognized Component, CE Marked, UL Recognized Component
    3966N12000000
     

    Submersible Liquid-Level Transmitters

    Image of Product. Front orientation. Liquid-Level Transmitters. Submersible Liquid-Level Transmitters, For Liquids.
    Image of Product. Top orientation. Liquid-Level Transmitters. Submersible Liquid-Level Transmitters, For Liquids with Solids.

    For Liquids

    For

    Liquids

    with

    Solids

    Best for measuring liquid levels in applications where traditional mounting is difficult, these transmitters sit at the bottom of your tank. They sense liquid levels by measuring the pressure from the weight of the liquid above them. These transmitters continuously send measurements, so you can monitor the status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
    For Liquids with Solids—Transmitters for liquids with solids have sink weights that keep the transmitter in place in applications with moving solids or agitated liquids.
    Overall
    For Pressure
    Accuracy
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    For Container Type
    Electrical
    Connection
    Enclosure
    Rating
    Each
    4 mA to 20 mA Output Current
     
    For Liquids
    0 to 5 psi / 0 to 11.5 ft. H₂O±0.5%7 psi @ 70° F1"5 5/8"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N110000000
    0 to 10 psi / 0 to 23 ft. H₂O±0.5%15 psi @ 70° F1"5 5/8"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N12000000
    0 to 15 psi / 0 to 34 ft. H₂O±0.5%22 psi @ 70° F1"5 5/8"32 to 1406012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N13000000
    0 to 20 psi / 0 to 46 ft. H₂O±0.5%30 psi @ 70° F1"5 5/8"32 to 1406012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N14000000
     
    For Liquids with Solids
    0 to 5 psi / 0 to 11.5 ft. H₂O±0.5%7 psi @ 70° F3 1/4"5 1/4"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N15000000
    0 to 10 psi / 0 to 23 ft. H₂O±0.5%15 psi @ 70° F3 1/4"5 1/4"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N16000000
    0 to 15 psi / 0 to 34 ft. H₂O±0.5%22 psi @ 70° F3 1/4"5 1/4"32 to 1406012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N17000000
    0 to 20 psi / 0 to 46 ft. H₂O±0.5%30 psi @ 70° F3 1/4"5 1/4"32 to 1406012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N18000000
     

    Ultrasonic Transmitters

    Measure the distance to objects and the level of liquids and materials despite size, shape, or surface finish, and send that information to other parts of your system. Unlike photoelectric switches, which use light to detect objects, these transmitters emit high-frequency sound waves that target small spots, so the surface and structure of your object won’t affect results. This makes them great for materials with uneven surfaces, such as granules and powder. They also sense objects in dirty and wet places, but they don’t work well where there’s wind, since it could disrupt their sound waves. Use their plug to quickly connect and disconnect to cables with a socket (sold separately). UL listed, C-UL listed, and CE marked, they meet American, Canadian, and European safety standards.
    All transmitters have an analog output, which means they continuously send measurements to monitor status and manage components in your system.
    Rated IP67, all of these transmitters seal out dust and water if briefly submersed.
    Straight
    Image of Product. Front orientation. Ultrasonic Sensors. Ultrasonic Transmitters, Straight.
    Image of Specification. 4-Pole M12 Plug. Front orientation. 4 Poles.

    4-Pole

    M12

    Plug

    Digital—Some transmitters also have a digital output that signals your controller to turn components on or off whenever an object is detected or a set level is reached.
    IO-Link Communication Protocol—Transmitters with IO Link connect to a programmable logic controller (PLC), so you can remotely change settings and receive error messages. You need an IO-Link controller (not included) to connect.
    Sensors
    Cables
    with Socket
    No. of
    Outputs
    Signal
    Output
    Output
    Signal
    Sensing Distance,
    mm
    Input Voltage,
    V DC
    Communication
    Protocol
    Dia.,
    mm
    Lg.,
    mm
    Housing
    Material
    Circuit Protection
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Each
    With 4-Pole M12 Plug-In Connection
     
    Analog
    14 mA to 20 mA40 to 30010 to 301861Stainless Steel
    Overload, Reverse Polarity, Short Circuit0 to 155IP67
    7635N1500000006897K36000000
    14 mA to 20 mA80 to 1.210 to 301861Stainless Steel
    Overload, Reverse Polarity, Short Circuit0 to 155IP67
    7635N160000006897K3600000
     
    Digital/Analog
    2PNP4 mA to 20 mA150 to 1.610 to 30IO-Link1898Stainless Steel
    Overload, Reverse Polarity, Short Circuit0 to 155IP67
    7635N170000006897K3600000
    2PNP4 mA to 20 mA250 to 3.510 to 30IO-Link30103Stainless Steel
    Overload, Reverse Polarity, Short Circuit0 to 155IP67
    7635N180000006897K3600000
     
    90° Elbow
    Image of Product. Front orientation. Ultrasonic Sensors. Ultrasonic Transmitters, 90° Elbow.
    Image of Specification. 4-Pole M12 Plug. Front orientation. 4 Poles.

    4-Pole

    M12

    Plug

    90° elbow transmitters are compact to fit in tight spaces. They’re best for conveyors.
    Digital—Some transmitters also have a digital output that signals your controller to turn components on or off whenever an object is detected or a set level is reached.
    Sensors
    Cables
    with Socket
    No. of
    Outputs
    Signal
    Output
    Output Signal
    Sensing Distance,
    mm
    Input Voltage,
    V DC
    Dia.,
    mm
    Lg.,
    mm
    Wd.,
    mm
    Ht.,
    mm
    Housing
    Material
    Circuit Protection
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Each
    With 4-Pole M12 Plug-In Connection
     
    Digital/Analog
    2PNP4 mA to 20 mA40 to 30010 to 3018382053PlasticOverload, Reverse Polarity, Short Circuit0 to 155IP67
    7635N1100000006897K36000000
    2PNP4 mA to 20 mA80 to 1.210 to 3018382053PlasticOverload, Reverse Polarity, Short Circuit0 to 155IP67
    7635N120000006897K3600000
    2PNP0V DC to 10V DC40 to 30010 to 3018382053PlasticOverload, Reverse Polarity, Short Circuit0 to 155IP67
    7635N130000006897K3600000
    2PNP0V DC to 10V DC80 to 1.210 to 3018382053PlasticOverload, Reverse Polarity, Short Circuit0 to 155IP67
    7635N140000006897K3600000
     

    Hazardous-Location Submersible Liquid-Level Transmitters

    Image of Product. Front orientation. Liquid-Level Transmitters. Hazardous-Location Submersible Liquid-Level Transmitters, For Liquids.
    Image of Product. Front orientation. Liquid-Level Transmitters. Hazardous-Location Submersible Liquid-Level Transmitters, For Liquids with Solids.

    For Liquids

    For Liquids with Solids

    FM and C-FM approved, these transmitters safely measure liquid levels where explosive gas or dust may be present. Set them at the bottom of your tank in applications that make traditional mounting difficult. They sense liquid levels by measuring the pressure from the weight of the liquid above them. All continuously send measurements, so you can monitor status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
    For Liquids with Solids—Transmitters for liquids with solids have an unobstructed sensing element that resists clogging and sludge buildup in water with particulate and sewage.
    Overall
    For Pressure
    Accuracy
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    For Container
    Type
    Electrical
    Connection
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    4 mA to 20 mA Output Current
     
    For Liquids
    0 psi to 1 psi / 0 to 3 ft. H₂O±0.25%10 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K510000000
    0 to 2 psi / 0 to 5 ft. H₂O±0.25%20 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K53000000
    0 to 4 psi / 0 to 10 ft. H₂O±0.25%40 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K55000000
    0 to 6 psi / 0 to 15 ft. H₂O±0.25%60 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K57000000
    0 to 13 psi / 0 to 30 ft. H₂O±0.25%125 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K59000000
     
    For Liquids with Solids
    0 psi to 1 psi / 0 to 3 ft. H₂O±0.25%10 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3100000000
    0 to 2 psi / 0 to 5 ft. H₂O±0.25%20 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3300000000
    0 to 4 psi / 0 to 10 ft. H₂O±0.25%40 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3500000000
    0 to 6 psi / 0 to 15 ft. H₂O±0.25%60 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3700000000
    0 to 13 psi / 0 to 30 ft. H₂O±0.25%125 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3900000000
     