McMaster-Carr logo
    Filter by
    System of Measurement
    Number of Stations
    Actuation
    Number of Solenoids
    Number of Flow Ports
    Return Actuation
    Number of Flow Positions
    Number of Outlet Ports
    Outlet Pipe Size
    Industrial Info Compare
    Pipe Size
    Industrial Info Compare
    Air Directional Control Valve Type
    Inlet Pipe Size
    Industrial Info Compare
    Maximum Pressure
    Inlet Thread Type
    Industrial Info Compare
    Inlet Connection
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    109 Products
    About Directional Control Valves
    industrial info icon

    Choose the right valve for your application by matching the actions you'll power to our flow diagrams.

    Modular Air Directional Control Valves with Air Manifolds

    Image of System. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air Manifolds.
    Mount valves to a single-station base or to a manifold, which allows a single pressure source for multiple valves, then add or remove valves as your needs change. Valves with the same style can be used on the same manifold. For example, you can put a Style B, 2-position, spring-return valve and a Style B, 3-position, solenoid-return valve on the same manifold.
    3-Way Valves
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air Manifolds, 3 Way.
    3-way valves create one action, such as extending a cylinder.
    Fail-Closed Valve—Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Style
    No. of
    Valves
    No. of Flow
    Ports
    No. of Flow
    Positions
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Body
    Material
    Mounting Fasteners
    Included
    Choose a Voltage
    Each
    3/2 Flow Pattern—Fail-Closed Valve
     
    Single Solenoid—Spring Return
    A1325.9940.19-14 to 14.529.92 11/16"3/4"3 1/16"Aluminum
    Yes12V DC, 24V DC, 110V AC61975K56000000
     
    4-Way Valves
    Image of Product. Single Solenoid Valve with Wire Leads. Front orientation. Single Solenoid. Modular Air Directional Control Valves with Air Manifolds, 4 Way.
    Image of Product. Double Solenoid Valve. Front orientation. Double Solenoid. Modular Air Directional Control Valves with Air Manifolds, 4 Way.

    Single Solenoid Valve

    with Wire Leads

    Double Solenoid Valve

    4-way valves create two actions, such as extending and then retracting a double-acting cylinder.
    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    5/3 (Exhaust Center) Flow Pattern—5/3 (exhaust center) valves exhaust all air pressure in the off position, allowing equipment to return to the neutral position.
    5/3 (Pressure Center) Flow Pattern—5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Style
    No. of
    Valves
    No. of Flow
    Ports
    No. of Flow
    Positions
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Wire
    Connection
    Lg.
    Wd.
    Ht.
    Body
    Material
    Mounting Fasteners
    Included
    Choose a
    Voltage
    Each
    5/2 Flow Pattern
     
    Single Solenoid—Spring Return
    B15280.2421 to 101Not RatedWire Leads2 5/8"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K83000000
    C152200.6421 to 101Not RatedWire Leads3 3/8"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K8800000
    D15235121 to 101Not RatedWire Leads4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9400000
     
    Double Solenoid—Solenoid Return
    B15280.2421 to 101Not RatedWire Leads3 1/2"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K8400000
    C152200.6421 to 101Not RatedWire Leads4 1/4"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K8900000
    D15235121 to 101Not RatedWire Leads4 3/4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9500000
     
    5/3 (Closed Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    B15360.1829 to 101Not RatedWire Leads3 7/8"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K8500000
    C153150.4729 to 101Not RatedWire Leads4 3/4"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K9100000
    D153230.7229 to 101Not RatedWire Leads5 1/4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9600000
     
    5/3 (Exhaust Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    B15360.1829 to 101Not RatedWire Leads3 7/8"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K8600000
    C153140.4429 to 101Not RatedWire Leads4 3/4"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K9200000
    D153230.7129 to 101Not RatedWire Leads5 1/4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9700000
     
    5/3 (Pressure Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    B15380.2429 to 101Not RatedWire Leads3 7/8"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K8700000
    C153150.4829 to 101Not RatedWire Leads4 3/4"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K9300000
    D153200.6329 to 101Not RatedWire Leads5 1/4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9800000
     
    Manifolds
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air Manifolds, Manifolds.
    Manifolds connect multiple valves to a common input pressure source and exhaust port.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Number
    of Ports
    Overall
    For
    Style
    Inlet
    Exhaust
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Choose a Number
    of Stations
    Each
    Threaded Female Inlet x Threaded Female Outlet
    A221/8 NPTF1/8 NPTFThreaded1 1/2"1"Yes2, 3, 461975K42000000
    A221/8 NPTF1/8 NPTFThreaded1 1/2"1"Yes5, 6, 7, 8, 9, 1061975K4300000
    B241/8 NPT1/8 NPTThreaded2 1/4"1 1/4"Yes2, 3, 462165K400000
    B241/8 NPT1/8 NPTThreaded2 1/4"1 1/4"Yes5, 6, 7, 8, 9, 1062165K500000
    C241/4 NPT1/4 NPTThreaded2 5/8"1 1/2"Yes2, 3, 462165K600000
    C241/4 NPT1/4 NPTThreaded2 5/8"1 1/2"Yes5, 6, 7, 8, 9, 1062165K700000
    D241/4 NPT1/4 NPTThreaded2 7/8"1 5/8"Yes2, 3, 462165K800000
    D241/4 NPT1/4 NPTThreaded2 7/8"1 5/8"Yes5, 6, 7, 8, 9, 1062165K900000
     

    Modular Air Directional Control Valves with Air and Electrical Manifolds

    Image of System. Complete System Shown with M12 Electrical Connection. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds .

    Complete System Shown with M12

    Electrical Connection

    Mix and match valve styles on one manifold to meet your control needs. Mount multiple valves to a manifold to reduce piping requirements and create multiple actions from a single pressure input. Add or remove valves as your needs change.
    3-Way Valves
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , 3 Way.
    3-way valves create one action, such as extending a cylinder. They have four flow positions, which allows the valve to operate as two independent valves from a single station on the manifold.
    Fail-Closed Valve—Fail-closed valves block airflow until actuated.
    Air Return—Valves with air return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of
    Valves
    Return
    Actuation
    No. of Flow
    Ports
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Body
    Material
    Mounting Fasteners
    Included
    Each
    3/2 Flow Pattern—Fail-Closed Valve
    2Air3148.41122 to 102Not Rated244 1/16"11/16"2 3/16"ManifoldAluminum
    Yes2866N26000000
     
    4-Way Valves
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , 4 Way.
    4-way valves create two actions, such as extending and then retracting a double-acting cylinder.
    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    5/3 (Exhaust Center) Flow Pattern—5/3 (exhaust center) valves exhaust all air pressure in the off position, allowing equipment to return to the neutral position.
    5/3 (Pressure Center) Flow Pattern—5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
    Air Return—Valves with air return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of
    Valves
    Return
    Actuation
    No. of Flow
    Ports
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Body
    Material
    Mounting Fasteners
    Included
    Each
    5/2 Flow Pattern
    1Air5167122 to 102Not Rated244 1/16"11/16"2 3/16"ManifoldAluminum
    Yes2866N24000000
    1Solenoid5166.97115 to 102Not Rated244 1/16"11/16"2 3/16"ManifoldAluminum
    Yes2866N2500000
     
    5/3 (Closed Center) Flow Pattern
    1Solenoid5167129 to 102Not Rated244 5/8"3/4"2 7/8"ManifoldAluminum
    Yes2866N2700000
     
    5/3 (Exhaust Center) Flow Pattern
    1Solenoid5167129 to 102Not Rated244 5/8"3/4"2 7/8"ManifoldAluminum
    Yes2866N2800000
     
    5/3 (Pressure Center) Flow Pattern
    1Solenoid5167129 to 102Not Rated244 5/8"3/4"2 7/8"ManifoldAluminum
    Yes2866N2900000
     
    Manifolds
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , Manifolds, DB25 Connection.
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , Manifolds, M12 Connection.

    DB25 Connection

    M12 Connection

    Manifolds connect multiple valves to a common input pressure source and exhaust port.
    IP40 Enclosure Rating—IP40 rated manifolds are protected from coarse particles larger than 1 mm.
    IP67 Enclosure Rating—IP67 rated manifolds are dust tight and protected from temporary submersion.
    Number
    of Ports
    Overall
    No. of
    Stations
    No. of Flow
    Ports
    Inlet
    Outlet
    Exhaust
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Exhaust
    Connection
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Body
    Material
    For DIN
    Rail Size, mm
    Mounting Fasteners
    Included
    Each
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet
     
    DB25 (IP40)
    282423/8"1/4"Push to Connect244 1/2"4 1/2"3"Screw InAluminum
    35Yes2866N50000000
    4122823/8"1/4"Push to Connect245 1/2"4 1/2"3"Screw InAluminum
    35Yes2866N6000000
    61621223/8"1/4"Push to Connect246 3/4"4 1/2"3"Screw InAluminum
    35Yes2866N7000000
    82021623/8"1/4"Push to Connect248"4 1/2"3"Screw InAluminum
    35Yes2866N8000000
     
    M12 (IP67)
    282423/8"1/4"Push to Connect244 3/4"4 1/2"3"Screw InAluminum
    35Yes2866N1000000
    4122823/8"1/4"Push to Connect246"4 1/2"3"Screw InAluminum
    35Yes2866N20100000000
    61621223/8"1/4"Push to Connect247 1/4"4 1/2"3"Screw InAluminum
    35Yes2866N30100000000
    82021623/8"1/4"Push to Connect248 1/2"4 1/2"3"Screw InAluminum
    35Yes2866N40100000000
     

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style F.

    Style A

    Style F

    Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style F.

    Style A

    Style F

    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoid Valve Plugs
    Replacement
    Solenoids
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Manifold
    Style
    Choose a Voltage
    Each
    Each
    Each
    Single Solenoid—Spring Return
    A51/8 NPT1/8 NPT43.10.7544 to 145Not Rated5 1/8"7/8"2 1/2"Manifold, Screw In112V DC6124K27400000006124K301000006124K335000000
    A51/8 NPT1/8 NPT43.10.7544 to 145Not Rated5 1/8"7/8"2 1/2"Manifold, Screw In124V DC6124K2750000006124K30100006124K33400000
    A51/8 NPT1/8 NPT43.10.7544 to 145Not Rated5 1/8"7/8"2 1/2"Manifold, Screw In1120V AC6124K2760000006124K30100006124K33300000
    A51/8 NPTF1/8 NPTF56115 to 15028 in. Hg5 1/2"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K11000000———0———0
    A51/4 NPT1/4 NPT43.11.344 to 145Not Rated6"1"2 5/8"Manifold, Screw In312V DC6124K2770000006124K30100006124K33500000
    A51/4 NPT1/4 NPT43.11.344 to 145Not Rated6"1"2 5/8"Manifold, Screw In324V DC6124K2780000006124K30100006124K33400000
    A51/4 NPT1/4 NPT43.11.344 to 145Not Rated6"1"2 5/8"Manifold, Screw In3120V AC6124K2790000006124K30100006124K33300000
    A51/4 NPTF1/4 NPTF56115 to 15028 in. Hg5 1/2"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K13000000———0———0
    A51/4 NPTF1/4 NPTF95.21.715 to 15028 in. Hg6"1"3"Manifold, Screw In424V DC, 120V AC6425K21000000———0———0
    A53/8 NPTF3/8 NPTF95.21.715 to 15028 in. Hg6"1"3"Manifold, Screw In424V DC, 120V AC6425K23000000———0———0
     
    Double Solenoid—Solenoid Return
    F51/8 NPT1/8 NPT43.10.7529 to 145Not Rated6 7/8"7/8"2 1/2"Manifold, Screw In112V DC, 24V DC, 120V AC6124K5150000006124K3010000———0
    F51/8 NPTF1/8 NPTF56115 to 15028 in. Hg8 1/4"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K12000000———0———0
    F51/4 NPT1/4 NPT43.11.329 to 145Not Rated7 7/8"1"2 5/8"Manifold, Screw In312V DC, 24V DC, 120V AC6124K5160000006124K3010000———0
    F51/4 NPTF1/4 NPTF56115 to 15028 in. Hg8 1/4"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K14000000———0———0
    F51/4 NPTF1/4 NPTF95.21.715 to 15028 in. Hg8 7/8"1"3"Manifold, Screw In424V DC, 120V AC6425K22000000———0———0
    F53/8 NPTF3/8 NPTF95.21.715 to 15028 in. Hg8 7/8"1"3"Manifold, Screw In424V DC, 120V AC6425K24000000———0———0
     
    Accessories for Valves

    Single-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style D.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style K.

    Style A

    Style D

    Style K

    These valves create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Also known as 3-way and 3/2 valves, they direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated. Valves without an exhaust connection exhaust air to the atmosphere.
    Threaded Female Inlet × Threaded Female Outlet: Fail-Closed Valve
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style A.

    Style A

    Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoid Valve Plugs
    Replacement
    Solenoids
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Lg.
    Wd.
    Ht.
    Mount Type
    Voltage
    Each
    Each
    Each
    Single Solenoid—Spring Return
    A31/8 NPT1/8 NPTThreaded24.90.7529 to 1454 5/8"7/8"1 3/8"Manifold, Screw In12V DC6124K27100000006124K30100000———0
    A31/8 NPT1/8 NPTThreaded24.90.7529 to 1454 5/8"7/8"1 3/8"Manifold, Screw In24V DC6124K2720000006124K30100006124K334000000
    A31/8 NPT1/8 NPTThreaded24.90.7529 to 1454 5/8"7/8"1 3/8"Manifold, Screw In120V AC6124K2730000006124K30100006124K33300000
    A31/4 NPT1/4 NPTThreaded24.91.329 to 1455 1/2"1"1 5/8"Manifold, Screw In12V DC6124K2910000006124K30100006124K33500000
    A31/4 NPT1/4 NPTThreaded24.91.329 to 1455 1/2"1"1 5/8"Manifold, Screw In24V DC6124K2920000006124K30100006124K33400000
    A31/4 NPT1/4 NPTThreaded24.91.329 to 1455 1/2"1"1 5/8"Manifold, Screw In120V AC6124K2930000006124K30100006124K33300000
     
    Threaded Female Inlet × Threaded Female Outlet: Fail-Open Valve/Fail-Closed Valve
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style D.

    Style D

    Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Fail-closed valves block airflow until actuated.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoid Valve Plugs
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Lg.
    Wd.
    Ht.
    Mount Type
    Choose a
    Voltage
    Each
    Each
    Double Solenoid—Solenoid Return
    D31/8 NPT1/8 NPTThreaded24.90.7529 to 1456 1/4"7/8"1 3/8"Manifold, Screw In24V DC, 120V AC6124K51400000006124K30100000
    D31/4 NPT1/4 NPTThreaded24.91.329 to 1457 1/16"1"1 5/8"Manifold, Screw In24V DC, 120V AC6124K5180000006124K3010000
     
    Push to Connect Female Inlet × Push to Connect Female Outlet: Fail-Closed Valve
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style K.

    Style K

    Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Lg.
    Wd.
    Ht.
    Mount Type
    Choose a Voltage
    Each
    Single Solenoid—Spring Return
    K35/32"5/32"Push to Connect0.60.010 to 1201 3/8"5/8"1 3/4"Manifold, Screw In12V DC, 24V DC, 120V AC62095K2000000
    K35/32"5/32"Push to Connect1.10.020 to 1201 3/8"5/8"1 3/4"Manifold, Screw In12V DC, 24V DC, 120V AC62095K100000
     
    Accessories for Valves

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Exhausting Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Exhausting Shut-Off, NPTF Inlet Thread, NPTF Outlet Thread.

    NPTF Inlet Thread

    NPTF Outlet Thread

    In the off position, these valves exhaust all air pressure, allowing the equipment to return to the neutral position. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 5/3 exhaust-center valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is electric (solenoid), so they go back to their original position when voltage moves from the first solenoid to the second solenoid.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount Type
    For Manifold
    Style
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Choose a
    Voltage
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Double Solenoid—Solenoid Return
    51/8 NPTF1/8 NPTFThreaded56115 to 150288 5/8"7/8"2 3/4"Manifold, Screw In2No0.13"24V DC, 120V AC6425K150000000
    51/4 NPTF1/4 NPTFThreaded56115 to 150288 5/8"7/8"2 3/4"Manifold, Screw In2No0.13"24V DC, 120V AC6425K16000000
    51/4 NPTF1/4 NPTFThreaded95.21.715 to 150289 3/8"1"3"Manifold, Screw In4No0.18"24V DC, 120V AC6425K25000000
    53/8 NPTF3/8 NPTFThreaded95.21.715 to 150289 3/8"1"3"Manifold, Screw In4No0.18"24V DC, 120V AC6425K26000000
     
    Accessories for Valves

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style A.

    Style A

    These valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way and 5/3 closed center valves.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style A.

    Style A

    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoid Valve Plugs
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Manifold
    Style
    Choose a Voltage
    Each
    Each
    Double Solenoid—Solenoid Return
    A51/8 NPT1/8 NPT280.544 to 145Not Rated7 1/2"7/8"1 3/8"Manifold, Screw In112V DC, 24V DC, 120V AC6124K200000006124K30100000
    A51/8 NPTF1/8 NPTF56115 to 15028 in. Hg8 5/8"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K17000000———0
    A51/4 NPT1/4 NPT530.9544 to 145Not Rated8 1/2"1"1 5/8"Manifold, Screw In312V DC, 24V DC, 120V AC6124K30000006124K3010000
    A51/4 NPTF1/4 NPTF56115 to 15028 in. Hg8 5/8"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K18000000———0
    A51/4 NPTF1/4 NPTF95.21.715 to 15028 in. Hg9 3/8"1"3"Manifold, Screw In424V DC, 120V AC6425K27000000———0
    A53/8 NPTF3/8 NPTF95.21.715 to 15028 in. Hg9 3/8"1"3"Manifold, Screw In424V DC, 120V AC6425K28000000———0
     
    Accessories for Valves
    back to top