Extended-Life Immersion Circulation Pumps for Water and Coolants
A sealless construction means these pumps have few moving parts that can fail and shorten service life. The intake can be completely submerged in liquid. Pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/312/3128n11-@halfx_636942196188829847.png?ver=imagenotfound)
Intake | Discharge | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ 10 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Electrical Connection Type | hp | Current | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | Each | |
24V DC—Without Thermal Overload Protection | |||||||||||||||||||
2.7 | 0.5 | 11 | 50 | 5 | 32° to 190° | Hardwire | Subfractional | 0.5A | 1/4 | Male | NPT | 1/4 | Male | NPT | 4 15/16" | 2 1/4" | 3 1/4" | 0000000 | 0000000 |
Self-Priming Stainless Steel Circulation Pumps for Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/101/1019n11p1-c01a-digital@halfx_636899899472627433.png?ver=imagenotfound)
Self-priming up to 6 ft., these pumps have a stainless steel housing sealed with PTFE to resist chemicals such as ammonia and detergents as well as harsh solvents including methyl ethyl ketone (MEK). The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
1 | 68 | 54 | 41 | __ | __ | __ | 50 | 75 | 20 | 3/4 | 9/5 | 1 1/2 | Female | 1 1/2 | Female | 15 3/4" | 8 3/4" | 9 1/2" | 0000000 | 000000000 |
2 | 100 | __ | 65 | 45 | __ | __ | 50 | 75 | 20 | 1 1/2 | 18/9 | 1 1/2 | Female | 1 1/2 | Female | 16 1/2" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
3 | 68 | 54 | 41 | __ | __ | __ | 50 | 75 | 20 | 3/4 | 3/2 | 1 1/2 | Female | 1 1/2 | Female | 15 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
4 | 100 | __ | 65 | 45 | __ | __ | 50 | 75 | 20 | 1 1/2 | 5/3 | 1 1/2 | Female | 1 1/2 | Female | 16 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
5 | 132 | __ | __ | 82 | 60 | 14 | 63 | 75 | 20 | 2 | 6/3 | 1 1/2 | Female | 1 1/2 | Female | 17 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
Polypropylene Air-Powered Transfer Pumps for Chemicals
Resistant to chemicals such as ammonia, detergents, and cleaning fluids, these pumps have a Santoprene diaphragm and polypropylene housing. They can be used to move thick sludges and slurries. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/415/4157k56-from-k54-@halfx_1712146711.png?ver=imagenotfound)
Max. Flow Rate, gpm | Flange (Class 125) | Bolt | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Size | Discharge Pipe Size | OD | Thick. | Circle Dia. | Hole Dia. | Lg. | Wd. | Ht. | Each | |
231 Max. ft. of Head—100 psi Max. Discharge Pressure | |||||||||||||||||
63 | 53 | 40 | 35 | 20,000 | 35 | 1/2 Female | 1 | 1 | 4 1/4" | 3/4" | 3 1/8" | 9/16" | 12" | 17" | 21" | 0000000 | 000000000 |
PTFE Air-Powered Transfer Pumps for Harsh Chemicals
With all PTFE wetted parts, these pumps offer the best chemical resistance of all our air-powered transfer pumps and can handle solvents and petroleum-based fluids that PVDF pumps can’t. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/292/2925n1-@halfx_636936834691763439.png?ver=imagenotfound)
Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
231 Max. ft. of Head—100 psi Max. Discharge Pressure | |||||||||
2.5 | 4.8 | 1/8 Female | 1/4 Female | 1/4 Female | 3 3/8" | 5 1/2" | 6 1/2" | 000000 | 000000000 |
6.7 | 9.3 | 1/8 Female | 3/8 Female | 3/8 Female | 3 1/2" | 5 7/8" | 7 5/8" | 000000 | 00000000 |
16 | 29 | 1/4 Female | 1/2 Female | 1/2 Female | 6" | 9 3/16" | 8" | 000000 | 00000000 |
39 | 46 | 1/4 Female | 1 Female | 1 Female | 8" | 10 7/8" | 10 3/8" | 000000 | 00000000 |
Fluid-Side Maintenance Kit for 2925N1 | 0000000 | Each | 0000000 |
Air-Motor Maintenance Kit for 2925N1 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 2925N4 | 0000000 | Each | 00000000 |
Air-Motor Maintenance Kit for 2925N4 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 2925N2 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 2925N2 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 2925N3 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 2925N3 | 0000000 | Each | 000000 |
316 Stainless Steel Air-Powered Transfer Pumps
for Chemicals, Fuel, and Flammable Liquids
With a 316 stainless steel housing and a PTFE diaphragm, these pumps resist a variety of acids, alkalies, and flammable liquids such as phosphoric acid, acetone, and methyl ethyl ketone (MEK). They're designed for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/994/9948k27p1-c01a-digital@halfx_636899929215322932.png?ver=imagenotfound)
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female | 1/2 Female | 9" | 10" | 10" | 00000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 00000000 | 00000000 |
106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 00000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 00000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 00000000 | 000000000 |
Fluid-Side Maintenance Kit for 41655K32 | 0000000 | Each | 000000000 |
Air-Motor Maintenance Kit for 41655K29, 41655K31, 41655K32 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 41655K27 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 41655K27 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K31 | 0000000 | Each | 00000000 |
Air-Motor Maintenance Kit for 41655K28 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K28 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K29 | 0000000 | Each | 00000000 |
Aluminum Air-Powered Transfer Pumps for Oil, Chemicals, and Fuel
These pumps have a PTFE diaphragm compatible with oil, fuel, and chemicals such as mineral spirits, methyl ethyl ketone (MEK), and xylene. They have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/994/9948k27p1-c01a-digital@halfx_636899929215322932.png?ver=imagenotfound)
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female, 1/2 Female | 1/2 Female, 1/2 Female | 9" | 10" | 12" | 0000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 0000000 | 00000000 |
106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 0000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 0000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 0000000 | 00000000 |
Fluid-Side Maintenance Kit for 9948K21 | 0000000 | Each | 000000000 |
Air-Motor Maintenance Kit for 9948K21, 9948K23 and 9948K24 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K16 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 9948K16 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K23 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 9948K24 | 0000000 | Each | 00000000 |
Aluminum Air-Powered Transfer Pumps for Water and Chemicals
The Santoprene diaphragm resists cracking for a long service life and stands up to water and chemicals such as ammonium hydroxide. These pumps have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/994/9948k27p1-c01a-digital@halfx_636899929215322932.png?ver=imagenotfound)
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female | 1/2 Female | 9" | 10" | 12" | 00000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 0000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 0000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 0000000 | 00000000 |
Fluid-Side Maintenance Kit for 9948K13 | 0000000 | Each | 0000000 |
Air-Motor Maintenance Kit for 9948K13 and 9948K14 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K12 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K12 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K14 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K111 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K111 | 0000000 | Each | 00000000 |
Compact Air-Powered Transfer Pumps
Small enough to fit in the palm of your hand, these pumps transfer water, detergents, and chemicals. They have a chemical-resistant polypropylene housing. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps can run dry.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/275/2753n11-@halfx_636936837722707295.png?ver=imagenotfound)
Max. Flow Rate, gpm | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 1 ft. of Head | @ 3 ft. of Head | @ 4 ft. of Head | @ 5 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection ID | Intake Tube Connection | Discharge Tube connection | Diaphragm Material | Lg. | Wd. | Ht. | Each | |
15 ft. of Head—100 psi Max. Discharge Pressure | |||||||||||||||
5 | 5 | 3.7 | 2.9 | 1.8 | 700 | 1.5 | 1/4" Male | 3/8" Male | 3/8" Male | Santoprene Rubber | 4 9/16" | 1 13/16" | 5 13/16" | 0000000 | 0000000 |
5 | 5 | 3.7 | 2.9 | 1.8 | 700 | 1.75 | 1/4" Male | 1/2" Male | 1/2" Male | Santoprene Rubber | 4 9/16" | 1 13/16" | 5 13/16" | 0000000 | 000000 |
Plastic Air-Powered Transfer Pumps for Fuel and Flammable Liquids
These pumps can be grounded to dissipate static electricity and are rated for use with flammable liquids such as gasoline, kerosene, isopropyl alcohol, and mineral spirits. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/134/13465k25p1-c01a-digital@halfx_636899904269196539.png?ver=imagenotfound)
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connections (NPT) | Discharge Pipe Connections (NPT) | Lg. | Wd. | Ht. | Each | |
231 ft. of Head—100 psi Max. Discharge Pressure | |||||||||||||
4 | 3.5 | 2 | 1 | 5,000 | 6 | 1/4 Female | 1/4 Female, 1/2 Male | 1/4 Female, 1/2 Male | 6" | 7" | 8" | 00000000 | 0000000 |
14 | 12 | 8 | 5 | 10,000 | 16 | 1/4 Female | 1/2 Female, 1 Male | 1/2 Female, 1 Male | 7" | 10" | 12" | 00000000 | 00000000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/260/2604k51p2-@halfx_636971534993109495.png?ver=imagenotfound)
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connections (NPT) | Discharge Pipe Connections (NPT) | Lg. | Wd. | Ht. | Each | |
288 ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
5.3 | 3.2 | 2.3 | 1.7 | Not Rated | 6.1 | 1/4 Female | 1/4 Female, 3/4 Male | 1/4 Female, 3/4 Male | 7" | 5" | 7" | 0000000 | 0000000 |
Pulsation Dampers for Air-Powered Transfer Pumps
![](/prerenderstable/mvPRE/contents/gfx/imagecache/306/3062n11-@halfx_636936804796076033.png?ver=imagenotfound)
Absorb pulsation caused by air-powered transfer pumps, reducing wear and preventing damage to inline components such as regulators, sensors, and gauges. Damping pulsation, or vibration, in your pipeline keeps instruments functional and readable. Install the damper as near to the pump’s discharge as possible.
Overall | |||||||
---|---|---|---|---|---|---|---|
Intake Pipe Connections (NPT) | Air Connection (NPT) | Housing Material | Dia. | Ht. | Includes | Each | |
Threaded Bottom Intake | |||||||
150 psi Max. Discharge Pressure | |||||||
1/2 Female | 1/8 Female | 316L Stainless Steel | 10 5/8" | 6 7/16" | 1 NPT to 1/2 NPT Adapter | 0000000 | 0000000 |
3/4 Female | 1/8 Female | 316L Stainless Steel | 10 5/8" | 6 7/16" | 1 NPT to 3/4 NPT Adapter | 0000000 | 000000 |
1 Female | 1/8 Female | 316L Stainless Steel | 10 5/8" | 6 7/16" | __ | 0000000 | 00000000 |
1 1/2 Female | 1/8 Female | 316L Stainless Steel | 13 3/4" | 8 3/16" | __ | 0000000 | 00000000 |
2 Female | 1/8 Female | 316L Stainless Steel | 13 3/4" | 8 3/16" | __ | 0000000 | 00000000 |
Selectable-Flow-Rate Easy-Stroke Drum Pumps for Water and Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/251/2515k46-@halfx_637195139720153662.png?ver=imagenotfound)
These pumps have a selectable flow rate, so you can adjust flow for different dispensing applications. A lever handle maximizes output with each stroke for low-effort dispensing.
Whenever working with flammable liquids, always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Intake | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | For Discharge Tube ID | Spout Type | Each | |
Stainless Steel Intake Tube and Housing | ||||||||||||
6, 8, 10, 12 | 15-55 | 2,000 | Not Rated | 140° | 1 1/2 NPT, 2 NPT | Drum Connector | 1 1/8" | 18 1/2"-32 1/2" | 11/16" | Removable | 0000000 | 0000000 |
Compact Drum Pumps for Water and Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/436/4368k13-c01a1558708500@halfx_636942898762236477.png?ver=imagenotfound)
Designed to move low volumes of caustic liquids in confined areas, these pumps have a thin intake tube and a small handle. They are often used to pump cleaning fluids, acid-washing solutions, and bleach.
Style A pumps have a selectable flow rate, so you can adjust flow for different dispensing applications.
Temp. Range, °F | Intake | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Spout Type | Each | |
A | 2, 4, 6, 8 | 5 | Not Rated | Not Rated | 125° | 3/4 NPT | __ | 5/8" | 18 1/4" | Fixed | 0000000 | 000000 |
A | 2, 4, 6, 8 | 15-55 | Not Rated | Not Rated | 125° | 2 NPT, 3/4 NPT | Two Drum Connectors | 5/8" | 33" | Fixed | 0000000 | 00000 |
A | 4, 8, 12, 16 | 15-55 | Not Rated | Not Rated | 125° | 2 NPT, 3/4 NPT | Two Drum Connectors | 5/8" | 33" | Fixed | 0000000 | 00000 |
Drum Pumps for Harsh Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/302/3024n1-@halfx_636942930913907044.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/302/3024n2-@halfx_636942135007975376.png?ver=imagenotfound)
Made with PTFE components, these pumps stand up to aggressive chemicals our other drum pumps can't, such as hydrochloric acid, bleach, sodium hydroxide, and methyl ethyl ketone (MEK). A stopcock prevents fluid and vapor from leaking after use.
Drum Pumps for Fuel and Flammable Liquid
![](/prerenderstable/mvPRE/contents/gfx/imagecache/425/4259k31p1-@halfx_637208300044302706.png?ver=imagenotfound)
All of these pumps have bonding and grounding wires, while some also have an internal flame arrester, to pump fuel, cleaning solvents, and lacquer thinners.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Steel pumps work with fuels and flammable liquids, but not especially aggressive and corrosive chemicals.
Stainless steel pumps handle aggressive and corrosive liquids that steel pumps cannot.
Pumps for 5-gallon containers have a drum connector that fits Rieke flex spouts and two screw cap adapters: 1 3/4" and 2 1/8".
Repair kits include components such as extension tubes, gaskets, and pistons.
Intake | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Max. Temp. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Features | Each | |
Steel | ||||||||||
4 | 5 | 110 | Not Rated | 1 3/4", 2 1/4", 2 1/8", 2 7/8" | Drum Connector, Flex Spout Adapter, Two Screw Cap Adapters (1 3/4" & 2 1/8") | 1/2" | 16" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 0000000 |
8 | 55 | 110 | Not Rated | 2 NPT | Drum Connector | 1/2" | 22" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
316 Stainless Steel | ||||||||||
10 | 5-7 | 650 | 140° F | 2 5/8", 2" | Drum Connector | 1 1/2" | 18" | Bonding and Grounding Wires | 0000000 | 000000 |
20 | 30-55 | 650 | 140° F | 2" | Drum Connector | 1 1/2" | 37 1/2" | Bonding and Grounding Wires | 0000000 | 000000 |
Repair Kit for Steel Pumps with 110 cP Max. Viscosity | 0000000 | Each | 0000000 |
Nondrip Drum Pumps for Fuel and Flammable Liquid
![](/prerenderstable/mvPRE/contents/gfx/imagecache/974/9743t11p1-@halfx_637209013117051884.png?ver=imagenotfound)
Eliminate leaks and waste with a faucet-style nondrip nozzle that quickly starts and stops flow. Pressurize your container with a few pumps of the plunger handle, and use the one-touch nozzle to manage flow. Hold down the nozzle for intermittent dispensing, open the nozzle fully for continuous flow, and close the nozzle to stop flow entirely.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
NFPA approved pumps are rated for use with Class I and II flammable and combustible liquids such as fuels, alcohols, and acetone.
Temp. Range, °F | Intake | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Features | Flammability Rating | Each | |
4.5 | 2-55 | 270 | 35° | 110° | 2 NPT | Drum Connector | 5/8" | 40" | Bonding and Grounding Wires | NFPA 30 18.4.4.1 | 0000000 | 0000000 |
Drum Pumps for Food and Beverage
![](/prerenderstable/mvPRE/contents/gfx/imagecache/424/4249k32-@halfx_1684879137.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/304/3047k38-@halfx_637523658513940302.png?ver=imagenotfound)
Use these pumps in food and beverage applications.
Style B-E pumps are FDA compliant for direct contact with food. Style B and C pumps have a colorful strap for color-coding your drums, which makes it easy to identify the drum contents.
Temp. Range, °F | Intake | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Discharge Location | Specifications Met | Strap Color | Each | |
A | 1 | 1 | 10,000 | 0° | 140° | 38 mm | Drum Connector | 1/4" | 6 1/2" | Spout End | FDA Compliant 21 CFR 177.1520 | __ | 0000000 | 00000 |
A | 1 | 5 | 10,000 | 0° | 140° | 38 mm | Drum Connector | 1/4" | 15" | Spout End | FDA Compliant 21 CFR 177.1520 | __ | 0000000 | 0000 |
B | 12 | 5 | 8,800 | 35° | 140° | 2 NPT | 5 Gallon Pail Adapter, Drum Connector | 1 5/8" | 16 1/2" | Spout End | FDA Compliant 21 CFR 174.5; FDA Compliant 21 CFR 177.1520; FDA Compliant 21 CFR 178.2010; FDA Compliant 21 CFR 178.3297; FDA Compliant 21 CFR 178.3400 | White | 0000000 | 00000 |
Siphon Drum Pumps
Since these pumps use suction to draw liquid out of your container, they continue dispensing once you get them started. They're often used with coolant and water.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/427/4270k21p1-@halfx_637208302406463773.png?ver=imagenotfound)
Temp. Range, °F | Intake | Discharge | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | ||
A | 2 | 5 | 150 | Not Rated | 140° | 11/16" | 16" | 9/16" | 11/16" | 21" | 0000000 | 00000 |
Air-Powered Drum Pumps for Flammable Liquid
![](/prerenderstable/mvPRE/contents/gfx/imagecache/282/2824k39-@halfx_637244628212960894.png?ver=imagenotfound)
These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Each | |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 000000000 |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
High-Pressure Air-Powered Drum Pumps for Fuel and Flammable Liquid
![](/prerenderstable/mvPRE/contents/gfx/imagecache/430/4304k51p1-@halfx_637208978741330804.png?ver=imagenotfound)
Use these pumps with fuel and flammable liquids, such as acetone, ethanol, and gasoline. They handle nearly twice the amount of pressure as other air-powered drum pumps to move high-viscosity liquids. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Air Connection | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
4 | 55 | 7,500 | 40° | 200° | 0-150 | 10 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2 1/8" | 33 11/16" | 3/4 | Female | NPT | 0000000 | 000000000 |
PVDF Extended-Life Air-Powered Drum Pumps for Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/828/8281k52p1-c01a-digital@halfx_636899923183446475.png?ver=imagenotfound)
A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Repair kits include O-rings, valves, and diaphragms.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
13 | 55 | 3,000 | 40° | 210° | 100 | 12 | 2 NPT | 1/4 | Female | NPT | 1/2 | Female | NPT | 36" | 1/2 | Female | NPT | 0000000 | 000000000 |
Repair Kit | 00000000 | Each | 0000000 |
Stainless Steel Extended-Life Air-Powered Drum Pumps for Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/828/8281k16p1-@halfx_637209008761515033.png?ver=imagenotfound)
A stainless steel construction allows these pumps to be used with aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Repair kits include balls, O-rings, and diaphragms.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
28 | 55 | 8,000 | 40° | 210° | 100 | 40 | 2 NPT | 1/4 | Female | NPT | 3/4 | Female | NPT | 39" | 3/4 | Female | NPT | 0000000 | 000000000 |
Repair Kit | 00000000 | Each | 0000000 |
Stainless Steel Extended-Life Air-Powered Drum Pumps for Food and Beverage
![](/prerenderstable/mvPRE/contents/gfx/imagecache/828/8281k16p1-@halfx_637209008761515033.png?ver=imagenotfound)
These pumps are designed for use in food and beverage applications. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Repair kits include balls, O-rings, and diaphragms.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Pipe Size | Gender | Thread Type | Tube Connection Type | For Tube OD | Tube Lg. | Tube Connection Type | For Tube OD | Each | |
28 | 55 | 8,000 | 40° | 210° | 100 | 40 | 2 NPT | 1/4 | Female | NPT | Quick Clamp | 1" | 39" | Quick Clamp | 1" | 0000000 | 000000000 |
Repair Kit | 0000000 | Each | 0000000 |
Aluminum Extended-Life Air-Powered Drum Pumps for Fuel
![](/prerenderstable/mvPRE/contents/gfx/imagecache/828/8281k16p1-@halfx_637209008761515033.png?ver=imagenotfound)
Pump fuel such as gasoline, kerosene, and diesel fuel. Also known as diaphragm pumps, these pumps have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Repair kits include balls, O-rings, and diaphragms.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
28 | 55 | 8,000 | 40° | 210° | 100 | 40 | 2 NPT | 1/4 | Female | NPT | 3/4 | Female | NPT | 39" | 3/4 | Female | NPT | 0000000 | 000000000 |
Repair Kit | 00000000 | Each | 0000000 |
Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/426/42675k47p1-@halfx_637208301849323560.png?ver=imagenotfound)
These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
Pumps | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Maintenance Parts | |||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Thermal Protection | Each | ||
120V AC, Single Phase | ||||||||||||||||
Hardwire | ||||||||||||||||
48.5 | 14 | 55 | 300 | -40° | 210° | 1/2 hp | 5.3 | 41 mm | 1 5/8" | 39" | Barbed | 1" | With Thermal Overload Protection | 00000000 | 000000000 | 00000000 |
Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/713/7133t25p1-@halfx_637208989092776205.png?ver=imagenotfound)
Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Environmental Rating | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||
316 Stainless Steel Housing | ||||||||||||||||
18 | 15 | 55 | 1,000 | Not Rated | 175° | 1 1/3 hp | 9.1 | 2 NPT | 1 1/2" | 39" | 1" | 1 1/4" | 72" | NEC Class I Divisions 1, 2 Group D IP55 | 0000000 | 000000000 |
Sanitary Electric Drum Pumps
![](/prerenderstable/mvPRE/contents/gfx/imagecache/373/3739n11-@halfx_637353316155149419.png?ver=imagenotfound)
Commonly used in food, beverage, pharmaceutical, and cosmetic processing, these pumps are designed for sanitary environments. The discharge connection can be easily disassembled for cleaning. Pumps do not include a drum connector.
Pumps that are 3-A certified meet sanitary design standards. Those that are CSA certified meet stringent safety standards.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size, mm | Tube OD | Tube Lg. | Tube Connection Type | For Tube OD | Thermal Protection | Specifications Met | Each | |
115V AC, Single Phase—Hardwire | ||||||||||||||||
Nylon Plastic Housing | ||||||||||||||||
31 | 10 | 55 | 1,000 | 15° | 175° | 1 hp | 4.2 | 38 | 1 1/2" | 39" | Quick Clamp | 1 1/2" | With Thermal Overload Protection | 3-A Certified 02-11; CSA Certified | 0000000 | 000000000 |