    44 Products

    Horizontal-Mount Float Switches for Fuels and Oils

    Image of Product. Front orientation. Float Switches. Horizontal-Mount Float Switches for Fuels and Oils, Style A.
    Image of Product. Style D. Front orientation. Style D. Horizontal-Mount Float Switches for Fuels and Oils.
    Image of Product. Style E. Front orientation. Style E. Horizontal-Mount Float Switches for Fuels and Oils.
    Image of Product. Style F. Front orientation. Style F. Horizontal-Mount Float Switches for Fuels and Oils.

    Style A

    Style D

    Style E

    Style F

    Image of Attribute. Front orientation. Contains Annotated. Float Switches. Horizontal-Mount Float Switches for Fuels and Oils.
    Install these switches into a threaded connection in your tank wall from outside the tank. They activate process equipment such as pumps or motors when the diesel fuel, hydraulic fluid, or oil level in your tank reaches the float. Choose switches with a metal body for durability in harsh conditions.
    Pipe
    Conduit
    Style
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Float Material
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Each
    120V AC/240V AC Input Voltage
     
    Polybutylene Body
    A1/2
    NPT
    Male0.85100 psi @ 70° F-40 to 1452 3/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACPolybutyleneWire Leads1/2
    NPT
    Male50205K32000000
     
    316 Stainless Steel Body
    D1/2
    NPT
    Male0.55100 psi @ 70° F-40 to 2253 11/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACPolypropylene
    Wire Leads1/2
    NPT
    Male46515K12000000
    D1/2
    NPT
    Male0.65100 psi @ 70° F-40 to 2503 11/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACNylon
    Wire Leads1/2
    NPT
    Male5123K22000000
    E1
    NPT
    Male0.85500 psi @ 70° F-40 to 3005 5/16"1 Off or 1 On
    SPDT
    0.17 amp @ 120V AC304 Stainless Steel
    Wire Leads1/2
    NPT
    Male46815K14000000
    F1
    NPT
    Male0.9900 psi @ 70° F-40 to 3004 1/8"1 Off or 1 On
    SPDT
    0.17 amp @ 120V AC316 Stainless Steel
    Wire Leads1/2
    NPT
    Male46815K12000000
     
    Brass Body
    E1
    NPT
    Male0.8150 psi @ 70° F-40 to 1803 7/8"1 Off or 1 On
    SPDT
    0.17 amp @ 120V ACBuna-N
    Wire Leads1/2
    NPT
    Male5126K19000000
     

    Speed-Monitoring Switches

    Image of System. Front orientation. Contains Annotated. Speed-Monitoring Switches. Speed-Monitoring Switches.
    Image of Product. Front orientation. Contains Annotated. Speed-Monitoring Switches. Speed-Monitoring Switches.
    Detect unwanted slowdowns in a rotary shaft that could cause machine damage and downtime. These switches are often used on drivetrains, conveyors, and other power-driven components. They come with a pulser disc, which you’ll need to attach to the shaft by drilling and tapping a hole. Once mounted, the disc rotates with the shaft and creates magnetic signals that the switch senses. When the speed falls below a set point, the switch will trigger an alarm or turn off the system.
    Switches are UL listed and rated NEC Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. They have an explosion-proof housing and are also rated NEMA 4X for washdown and corrosion protection.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Switching
    Input
    Conduit
    Mounting
    Slot
    Activation
    Point Range, rpm
    Current,
    amp
    Voltage,
    V AC
    Voltage,
    V AC
    Freq.,
    Hz
    No. of
    Terminals
    Trade
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    No.
    of
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Housing
    Material
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    1 Off (Normally Open), 1 On (Normally Closed) Starting Switch Position
     
    SPDT
    5 to 10051201206051
    NPT
    Female1 1/4"0.32"24.4"3.7"4.8"YesAluminum
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    6177K110000000
     

    Ultrasonic Noncontact Level Sensor Switches for Chemicals

    Image of Product. Front orientation. Level Sensor Switches. Ultrasonic Noncontact Level Sensor Switches for Chemicals.
    Use high-frequency sound waves to detect chemical level. This switch has three relays that can be programmed for multiple set points. Use it to activate several alarms or to automate tank filling and emptying. It’s rated NEMA 4X for protection from corrosion and washdowns.
    Pipe
    Conduit
    Size
    Thread
    Type
    Gender
    Sensing Distance,
    ft.
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Lg.
    Wd.
    Electrical
    Connection
    Enclosure
    Rating
    Trade
    Size
    Thread
    Type
    Gender
    Each
    95V AC to 250V AC Input Voltage
     
    Polycarbonate Body
    1
    NPT
    Male0.33 to 9.830 psi @ 70° F-5 to 1401 Off or 1 On
    SPDT
    0.17 amp @ 120V AC3 15/16"5 3/16"Screw TerminalIP65, NEMA 4X
    1/2
    NPT
    Female3785K13000000000
     

    Hazardous Location Float Switches for Water

    Image of Product. Front orientation. Contains Annotated. Float Switches. Hazardous Location Float Switches for Water.
    For use in locations with flammable gases and combustible dust, these switch are UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount them vertically through the top of your tank. They're rated NEMA 4 for protection from washdowns.
    Pipe
    Float
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Lg.
    Dia.
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    Brass Body and 316 Stainless Steel Float
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2755 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N130000000
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2757 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N16000000
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    4914K96000000
    2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N11000000
     

    Hazardous Location Vibration Switches

    Image of Product. Front orientation. Contains Annotated. Vibration Switches. Hazardous Location Vibration Switches.
    Get NEMA 4 and IP66 protection from dirt and water. These switches are rated for hazardous locations for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. If vibration or shock exceeds a set activation point, the contacts actuate to either shut down your machine or activate an alarm. Reset the switch with the push of a button. The activation point is adjustable between 0 to 5 gravity units (g) at 0 to 60 Hz.
    Activation
    Point
    Switching
    Housing
    Conduit
    Mounting
    Slot
    Range,
    g
    Freq. Range,
    Hz
    Current,
    amp
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Trade
    Size
    Thread
    Type
    Gender
    Mounting Fasteners
    Included
    No. of Mounting
    Holes
    Lg.
    Wd.
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    1 Off or 1 On Switch Starting Position
     
    SPDT
    0 to 50 to 6015125
    480
    4.2"4 3/4"6"-40 to 1553/4
    NPT
    FemaleNo43/4"3/8"NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP66
    NEMA 4
    UL Listed, C-UL Listed, CSA-US Certified, CSA Certified, CE Marked
    1188T310000000
     

    Horizontal-Mount Float Switches for Food and Beverage

    Image of Product. Front orientation. Float Switches. Horizontal-Mount Float Switches for Food and Beverage.
    Image of Attribute. Front orientation. Contains Annotated. Horizontal-Mount Float Switches for Food and Beverage.
    Install these switches into a threaded connection in your tank wall from outside the tank. Often used in food-processing applications, they meet NSF/ANSI Standard 169.
    Pipe
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    Polypropylene Body and Float
    1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2202 3/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/2
    NPT
    MaleUL Recognized Component, CSA Certified
    46515K41000000
     

    Vertical-Mount Hazardous Location Float Switches for Fuels and Oils

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Hazardous Location Float Switches for Fuels and Oils.
    For use in locations with flammable gases and combustible dust, these switches are UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount them vertically through the top of your tank. They're rated NEMA 4 for protection from washdowns.
    Pipe
    Float
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Lg.
    Dia.
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    316 Stainless Steel Body and Float
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    4914K97000000000
     

    Float Liquid-Level Transmitters

    Image of Product. Front orientation. Liquid-Level Transmitters. Float Liquid-Level Transmitters.
    Easy to set up and use, these transmitters measure liquid levels using a standard float gauge. They continuously send measurements to a receiving device, such as a programmable logic controller, so you can monitor status and manage components in your system.
    Pipe
    Overall
    For Tank
    Dp.
    Size
    Type
    Gender
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    For Container Type
    Electrical
    Connection
    Certification
    Each
    4 mA to 20 mA Output Signal
     
    Polypropylene Float
    19"1 1/2
    NPT
    Male100 psi @ 70° F1 7/8"21"-40 to 220212 to 30Closed Tank, Open TankWire LeadsC-UL Recognized Component, CE Marked, UL Recognized Component
    3966N110000000
     
    316 Stainless Steel Float
    24"2
    NPT
    Male200 psi @ 70° F2 3/8"27"-40 to 220212 to 30Closed Tank, Open TankWire LeadsC-UL Recognized Component, CE Marked, UL Recognized Component
    3966N12000000
     

    Horizontal-Mount Float Switches for Chemicals

    Image of Product. Switch. Front orientation. Horizontal-Mount Float Switches for Chemicals.
    Image of Product. Switch with Splash Guard. Front orientation. Horizontal-Mount Float Switches for Chemicals, Splash Guard.
    Image of Attribute. Front orientation. Contains Annotated. Float Switches. Horizontal-Mount Float Switches for Chemicals.

    Switch

    Switch with Splash Guard

    Install these switches into a threaded connection in your tank wall from outside the tank. They activate process equipment such as pumps or motors when the chemical level in your tank reaches the float.
    Splash Guard—Switches with splash guard minimize false switch activation caused by splashing liquid.
    Pipe
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Each
    120V AC/240V AC Input Voltage
     
    PVDF Body and Float
    1/2
    NPT
    Male0.85100 psi @ 70° F-40 to 2202 3/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/2
    NPT
    Male5082K21000000
     
    PVDF Body and Float with Splash Guard
    1
    NPT
    Male0.85100 psi @ 70° F-40 to 2201 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/2
    NPT
    Male5082K22000000
     
    Polypropylene Body and Float
    1/2
    NPT
    Male0.7100 psi @ 70° F-40 to 2202 3/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/4
    NPT
    Male46515K4300000
     
    Polypropylene Body and Float with Splash Guard
    1
    NPT
    Male0.7100 psi @ 70° F-40 to 2201 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/2
    NPT
    Male46515K8100000
     

    Paddle Level Switches for Dry Materials

    Image of Product. Front orientation. Contains Annotated. Paddle Level Switches. Horizontal Mount.
    Image of Product. Front orientation. Contains Annotated. Paddle Level Switches. Vertical Mount.

    Horizontal Mount

    Vertical Mount

    Monitor the level of dry material in surge bins, tanks, and silos to avoid overspills and outages. With a long paddle, these switches extend farther into large storage containers to detect material levels where other types of switches can’t reach. You can even adjust the paddle's sensitivity to materials of different sizes and shapes, such as powders, plastic pellets, and wood chips. Install multiple switches on the same container to monitor levels at various points. They are rated NEMA 4X and IP66 for protection from corrosion and washdowns.
    Horizontal Mount—Commonly installed near the bottom of containers to indicate low levels as material flows out. These switches start to rotate when material falls low enough to uncover the paddle, triggering a conveyor, pump, or other piece of equipment to prevent the container from emptying.
    Vertical Mount—Mount to the roof of containers to indicate high levels when loading material. For domed roofs, you can extend these switches farther down by connecting the paddle to your desired length of 1/8 NPT Schedule 40 pipe. The paddle rotates freely until material rises to its level and stops it, triggering a conveyor, pump, or other piece of equipment to prevent overfilling.
    With Alarm—Switches with an alarm alert you to potential malfunctions before they occur. They continuously perform self-diagnostics to detect everything from motor failure to seized bearings. When they detect an error, an LED light flashes in a corresponding code, so maintenance workers will immediately know which problem they need to fix.
    Paddle
    Switch
    Insertion
    Dp.
    Material Wt. Cap.
    Range, lb/ft³
    Max. Pressure
    @ Temp.
    Speed,
    rpm
    Lg.
    Wd.
    Material
    Starting
    Position
    Designation
    Current @
    Voltage
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Horizontal Mount
     
    Without Alarm
    6 5/8"3.4 to 3030 psi @ 70° F17"2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    20 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K510000000
     
    With Alarm
    6 5/8"3.4 to 3030 psi @ 70° F17"2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    8 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K26000000
     
    Vertical Mount
     
    Without Alarm
    12"30 to 7030 psi @ 70° F15"1 1/2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    20 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K52000000
     
    With Alarm
    12"30 to 7030 psi @ 70° F15"1 1/2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    8 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K36000000
     
    Replacements for Paddle Level Switches

    Hazardous Location Float Switches for Chemicals

    Image of Product. Style A. Front orientation. Float Switches. Hazardous Location Float Switches for Chemicals, 316 Stainless Steel Body and Float, Style A.
    Image of Product. Style B. Front orientation. Float Switches. Hazardous Location Float Switches for Chemicals, 316 Stainless Steel Body and Float, Style B.

    Style A

    Style B

    Image of Attribute. Front orientation. Contains Annotated. Hazardous Location Float Switches for Chemicals.
    Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall.
    Style A—Style A meet Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
    Style B—Style B meet Class I, Divisions 1 and 2, Groups C and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
    Pipe
    Conduit
    Style
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    316 Stainless Steel Body and Float
    A1/2
    NPT
    Male0.7300 psi @ 70° F0 to 3904 5/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/4
    NPT
    MaleUL Recognized Component, CSA Certified, CE Marked
    46815K110000000
    A1/2
    NPT
    Male0.7300 psi @ 70° F0 to 3904 5/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/2
    NPT
    MaleUL Recognized Component, CSA Certified, CE Marked
    46815K22000000
    A1
    NPT
    Male0.7300 psi @ 70° F0 to 3904 5/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/2
    NPT
    MaleUL Recognized Component, CSA Certified, CE Marked
    46815K21000000
    B1 1/2
    NPT
    Male0.41,500 psi @ 70° F0 to 3003 1/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.83 amp @ 120V ACWire Leads1/2
    NPT
    MaleCSA Certified, FM Approved
    5300K55000000
    B2
    NPT
    Male0.41,500 psi @ 70° F0 to 3003 1/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.83 amp @ 120V ACWire Leads1/2
    NPT
    MaleCSA Certified, FM Approved
    5300K58000000
     

    Horizontal-Mount Float Switches for Water

    Image of Product. PPS. Side1 orientation. Float Switches. Horizontal-Mount Float Switches for Water, PPS Body.
    Image of Product. Front orientation. Float Switches. Horizontal-Mount Float Switches for Water, 303 Stainless Steel Body.
    Image of Product. Front orientation. Float Switches. Horizontal-Mount Float Switches for Water, Brass Body.

    PPS

    303 Stainless Steel Body

    Brass Body

    Image of Product. Front orientation. Float Switches. Horizontal-Mount Float Switches for Water, 304 Stainless Steel Body.
    Image of Product. Front orientation. Float Switches. Horizontal-Mount Float Switches for Water, 316 Stainless Steel Body.
    Image of Attribute. Front orientation. Contains Annotated. Float Switches. Horizontal-Mount Float Switches for Water.

    304 Stainless Steel Body

    316 Stainless Steel Body

    Install these switches into a threaded connection in your tank wall from outside the tank. They activate process equipment such as pumps or motors when the water level in your tank reaches the float. Some meet European safety standards.
    Choose switches with a brass or stainless steel body for durability in harsh conditions.
    Pipe
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Float Material
    Electrical
    Connection
    Trade
    Size
    Pipe
    Size
    Thread
    Type
    Gender
    Each
    120V AC Input Voltage
     
    303 Stainless Steel Body
    1
    NPT
    Male0.7350 psi @ 70° F40 to 2001 3/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V AC304 Stainless Steel
    Wire Leads1/8
    NPT
    Male48255K310000000
     
    Brass Body
    1
    NPT
    Male0.91,000 psi @ 70° F40 to 2001 3/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACPolypropylene
    Wire Leads1/8
    NPT
    Male48255K26000000
     
    120V AC/240V AC Input Voltage
     
    PPS Body
    1
    NPT
    Male0.6150 psi @ 70° F40 to 2104 3/4"1 Off or 1 On
    SPDT
    5 amp @ 120V ACPPSWire Leads1/2
    NPT
    Male46235K25000000
     
    304 Stainless Steel Body—CE Marked
    1/2
    NPT
    Male0.85360 psi @ 70° F0 to 2503 1/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V AC304 Stainless Steel
    Wire Leads1/2
    NPT
    Male48255K11100000
     
    316 Stainless Steel Body
    1
    NPT
    Male0.751,000 psi @ 70° F-30 to 3005"1 Off or 1 On
    SPDT
    0.16 amp @ 120V AC316 Stainless Steel
    Wire Leads1/2
    NPT
    Male48255K112000000
     

    Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils

    Image of Product. Style A. Front orientation. Style A. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.
    Image of Product. Style B. Front orientation. Style B. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.

    Style A

    Style B

    Image of Product. Style C. Front orientation. Style C. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.
    Image of Attribute. Front orientation. Contains Annotated. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.

    Style C

    Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall. All are rated NEMA 4 for protection from washdowns. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” or from “on” to “off”.
    Switches with a stainless steel body are more corrosion resistant than switches with a brass body.
    Pipe
    Conduit
    Style
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Current @
    Voltage
    Float Material
    Trade
    Size
    Thread
    Type
    Gender
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    120V AC/240V AC Input Voltage
     
    Brass Body
    A1
    NPT
    Male0.7350 psi @ 70° F0 to 2201 3/4"5 amp @ 120V AC304 Stainless Steel
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K120000000
    A1
    NPT
    Male0.91,000 psi @ 70° F0 to 2201 3/4"5 amp @ 120V ACPolypropylene
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K63000000
    B1
    NPT
    Male0.5200 psi @ 70° F0 to 2202 7/8"5 amp @ 120V AC304 Stainless Steel
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K11000000
    C1 1/2
    NPT
    Male0.7100 psi @ 70° F0 to 27513 3/16"10 amp @ 120V AC316 Stainless Steel
    3/4
    NPT
    FemaleNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP56
    NEMA 4
    4914K86000000
     
    303 Stainless Steel Body
    A1
    NPT
    Male0.92,000 psi @ 70° F0 to 2201 3/4"5 amp @ 120V ACPolypropylene
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K65000000
    B1
    NPT
    Male0.5200 psi @ 70° F0 to 2202 7/8"5 amp @ 120V AC304 Stainless Steel
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K13000000
     
    316 Stainless Steel Body
    C1 1/2
    NPT
    Male0.7100 psi @ 70° F0 to 27513 3/16"10 amp @ 120V AC316 Stainless Steel
    3/4
    NPT
    FemaleNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP56
    NEMA 4
    4914K8700000000
     
    back to top