    21 Products

    Enclosed DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. Enclosed DC Motor Drives.
    Housed in a durable steel enclosure, these drives convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors.
    Heat Sinks—A heat sink (sold separately) is required with outputs greater than 5 amps.
    Drives
    Heat Sinks
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Each
    Single-Phase Input
     
    Nonreversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    108"6"Screw TerminalYes0.19" (3)On/Off SwitchIndoor OnlyNEMA 1
    C-UL Listed, UL Listed
    7793K5100000007793K550000000
     

    VFDs

    Image of Product. Front orientation. VFDs. VFDs.
    Set these VFDs to automatically adjust motor speed. Wire a potentiometer (not included) for remote manual control.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Current,
    amp
    Voltage,
    V AC
    Freq.,
    Hz
    Input Analog Signal
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1115/2304.20 to 2300 to 5000 to 10V DC, 4 to 20 mA7.5"3.9"No0.22" (4)Wet, Indoor OnlyNEMA 1, IP31
    UL Listed
    C-UL Listed
    CE Marked
    7786K490000000
    2200 to 2407.32300 to 1200 to 10V DC, 4 to 20 mA7.5"3"Yes0.2" (4)Thermal Overload ProtectionIndoor OnlyNEMA 1, IP20
    UL Listed
    C-UL Listed
    CE Marked
    7786K431000000
    3200 to 240100 to 2300 to 5000 to 10V DC, 4 to 20 mA7.9"4"No0.22" (4)Indoor OnlyNEMA 1, IP20
    UL Listed
    C-UL Listed
    CE Marked
    7786K221000000
     
    Single-Phase Input/Three-Phase Input
     
    Reversing Motor
    2200 to 2407.30 to 2300 to 5000 to 10V DC, 4 to 20 mA7.9"4"No0.22" (4)Indoor OnlyNEMA 1, IP20
    UL Listed
    C-UL Listed
    CE Marked
    7786K241000000
     

    DIN-Rail Mount VFDs

    Image of Product. Front orientation. VFDs. DIN-Rail Mount VFDs.
    Mount these VFDs to DIN rail inside a control panel. Set them to automatically adjust motor speed. Wire a potentiometer (not included) for remote manual control.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Current,
    amp
    Voltage,
    V AC
    Freq.,
    Hz
    Input Analog Signal
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1/2100 to 12031150 to 4000 to 10V DC, 4 to 20 mA5.98"2.83"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K6510000000
    1100 to 1204.81150 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.22" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K652000000
    1200 to 2404.82300 to 4000 to 10V DC, 4 to 20 mA5.98"2.83"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K658000000
    2200 to 2407.82300 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K655000000
    3200 to 240112300 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.22" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K656000000
     

    Reversing Enclosed DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. Reversing Enclosed DC Motor Drives.
    Use these drives with motors that run forward and backward, such as motors for conveyor belts. They convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors. Housed in a durable steel enclosure.
    Heat Sinks—A heat sink (sold separately) is required with outputs greater than 5 amps.
    Drives
    Heat Sinks
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Each
    Single-Phase Input
     
    Reversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    108"6"Screw TerminalYes0.19" (3)On/Off SwitchIndoor OnlyNEMA 1
    C-UL Listed, UL Listed
    7793K5200000007793K550000000
     

    DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. DC Motor Drives.
    Convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors.
    Heat Sinks—A heat sink (sold separately) is required with outputs greater than 5 amps.
    Drives
    Heat Sinks
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Certification
    Each
    Each
    Single-Phase Input
     
    Nonreversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    103.6"4.3"Screw TerminalYes0.19" (6)C-UL Listed, UL Listed
    7793K1200000007793K65000000
     

    Washdown DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. Washdown DC Motor Drives.
    A NEMA 4X rated enclosure protects these drives from corrosion and washdowns. They convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors.
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Single-Phase Input
     
    Nonreversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    107.5"5.63"Screw TerminalYes0.19" (4)On/Off SwitchCorrosive, Dusty, Outdoor, Washdown, WetNEMA 4X
    C-UL Listed, UL Listed
    7793K630000000
     

    Washdown VFDs

    Image of Product. Front orientation. VFDs. Washdown VFDs.
    Rated NEMA 4, these VFDs are protected from washdowns. Set them to automatically adjust motor speed. Wire a potentiometer (not included) for remote manual control.
    NEMA 12 Enclosure Rating—Controls rated NEMA 12 also protect against splashes of oil and coolant when used indoors only.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Current,
    amp
    Voltage,
    V AC
    Freq.,
    Hz
    Input Analog Signal
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure Rating
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1200 to 2404.2200 to 2400 to 1200 to 10V DC, 4 to 20 mA8"6.5"No0.25" (4)Corrosive, Oily, Outdoor, Washdown, Wet, DustyNEMA 4, NEMA 12, IP65
    UL Listed
    C-UL Listed
    CE Marked
    7786K720000000
     
    Single-Phase Input/Three-Phase Input
     
    Reversing Motor
    2200 to 2407200 to 2400 to 5000 to 10V DC, 4 to 20 mA8"6.28"Yes0.2" (4)Thermal Overload ProtectionOutdoor, Washdown, Wet, DustyNEMA 4, IP65
    UL Listed
    C-UL Listed
    CE Marked
    7786K39000000
     

    Reversing Washdown DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. Reversing Washdown DC Motor Drives.
    Use these drives with motors that run forward and backward, such as motors for conveyor belts. They have a NEMA 4X rated enclosure to withstand corrosion and washdowns. Use them to convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors.
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    107.5"5.63"Screw TerminalYes0.19" (4)On/Off SwitchCorrosive, Dusty, Outdoor, Washdown, WetNEMA 4X
    C-UL Listed, UL Listed
    7793K640000000
     

    Open Frame VFDs

    Image of Product. Front orientation. VFDs. Open Frame VFDs.
    Vary the speed of three-phase AC motors. Mount these VFDs inside a machine or control cabinet. They’re often used in packaging machines, conveyors, and vacuum equipment. Operate VFDs manually or remotely with an electrical signal.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Voltage,
    V AC
    Freq.,
    Hz
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1/2115/2302300 to 1203"4.3"Yes0.19" (6)Maximum Speed Setting, Run and Jog Modes, Torque BoostUL Listed
    C-UL Listed
    6488K210000000
    1115/2302300 to 1204.4"6.9"Yes0.19" (6)Maximum Speed Setting, Run and Jog Modes, Torque BoostUL Listed
    C-UL Listed
    6488K22000000
     