McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    16 Products

    Sanitary and Washdown Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Face-Mount AC Motors, Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure.
    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Face-Mount AC Motors, Totally Enclosed Nonventilated (TENV) Motor Enclosure.

    Totally Enclosed Fan-Cooled

    (TEFC) Motor Enclosure

    Totally Enclosed Nonventilated

    (TENV) Motor Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Face-Mount AC Motors.
    Bolt these motors directly to conveyors and other machines to power equipment on food and sanitary lines. They help you meet Good Manufacturing Practices (GMP) since they have many features that make them safe for sanitary and washdown environments. Smooth contours and a laser-marked nameplate limit the space where bacteria could grow. They don’t have feet, so they’re easy to rinse down thoroughly. A stainless steel enclosure, epoxy resin lined interior, and IP69 rating mean they withstand hot spraying water, harsh cleaners, and sanitizers common to food plants. A two-barrier seal keeps water from getting in through the shaft. If water does seep in, drain plugs let it out.
    These motors are also called C-face motors. They’re rated for continuous duty, so they’ll run equipment that never turns off. Inverter rated, they also work with variable frequency drive (VFD) to run at different speeds. You can wire for clockwise or counterclockwise rotation; instructions are included. Their conduit box also rotates to connect conduit from any side without needing to reroute power.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan-cooled) motors have a fan that cools the housing.
    Totally Enclosed Nonventilated (TENV) Motor Enclosure—TENV (totally enclosed nonventilated) motors don’t need a fan or ventilation. They have even fewer places for water and contaminants to get in than TEFC motors.
    Overall
    Shaft
    Insulation
    Torque @ 460V
    AC, in·lbf
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Starting
    Torque
    Continuous Operating
    Torque
    Enclosure
    Rating
    Each
    208V AC/230V AC/460V AC, Three Phase
     
    NEMA 56C—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    1/21,8001.9 amp/1.8 amp/0.9 ampNo13"9 7/8"6 1/2"5/8"1 7/8"3 1/4"KeyedH3566117.8IP69
    3540N12000000000
     
    NEMA 56C—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box
    3/43,6002.1 amp/2.0 amp/1.0 ampYes11 3/4"9 7/8"6 1/2"5/8"1 7/8"3 1/4"KeyedH35656.813.5IP69
    3540N1300000000
     
    230V AC/460V AC, Three Phase
     
    NEMA 56C—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    3/41,8002.6 amp/1.3 ampYes14"9 7/8"6 1/2"5/8"1 7/8"3 1/4"KeyedH35696.126.8IP69
    3540N1400000000
    21,8005.6 amp/2.8 ampYes14"9 7/8"6 1/2"5/8"2"3 1/4"KeyedH35620872.1IP69
    3540N2500000000
     
    NEMA 56C—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box
    13,6002.8 amp/1.4 ampNo11 3/4"9 7/8"6 1/2"5/8"1 7/8"3 1/4"KeyedH35696.118.2IP69
    3540N1500000000
    1 1/23,6003.6 amp/1.8 ampYes13 3/4"9 7/8"6 1/2"5/8"2"3 1/4"KeyedH356122.427.7IP69
    3540N1800000000
    23,6004.8 amp/2.4 ampNo15"9 7/8"6 1/2"5/8"2"3 1/4"KeyedH356165.635.8IP69
    3540N2300000000
     
    NEMA 143TC—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    21,8005.6 amp/2.8 ampYes14"9 7/8"6 1/2"7/8"2 1/8"3 1/4"KeyedH35620872.1IP69
    3540N2600000000
     
    NEMA 145TC—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    33,6007.4 amp/3.7 ampYes16 1/4"9 7/8"6 1/2"7/8"2 1/8"3 1/4"KeyedH35620454IP69
    3540N2700000000
     

    Sanitary and Washdown Base/Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Base/Face-Mount AC Motors, Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure.
    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Base/Face-Mount AC Motors, Totally Enclosed Nonventilated (TENV) Motor Enclosure.

    Totally Enclosed Fan-Cooled

    (TEFC) Motor Enclosure

    Totally Enclosed Nonventilated

    (TENV) Motor Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Base/Face-Mount AC Motors.
    Image of Specification. Front orientation. Contains Annotated. 9 3/4" Overall Width. Sanitary and Washdown Base/Face-Mount AC Motors.
    For versatility in food and sanitary lines, these motors mount by their feet or bolt directly to equipment to power pumps and other machines. Many features make them safe for sanitary and washdown environments: Smooth contours and a laser-marked nameplate limit where bacteria could grow. A stainless steel enclosure, epoxy resin lined interior, and IP69 rating mean they stand up to hot spraying water, chemicals, and harsh cleaners often used in food plants. A two-barrier seal on the shaft stops water from getting in. If water does seep in, drain plugs let it out.
    Rated for continuous duty, these motors run equipment that never turns off. They’re also inverter rated, so they work with variable frequency drive (VFD) to run at different speeds. You can wire for clockwise or counterclockwise rotation; instructions are included. The conduit box also rotates, so there’s no need to reroute power when connecting conduit.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan-cooled) motors have a fan that cools the housing.
    Totally Enclosed Nonventilated (TENV) Motor Enclosure—TENV (totally enclosed nonventilated) motors don’t need a fan or ventilation. They have even fewer places for water and contaminants to get in than TEFC motors.
    Overall
    Shaft
    Insulation
    Torque @ 460V
    AC, in·lbf
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Starting
    Torque
    Continuous Operating
    Torque
    Enclosure
    Rating
    Each
    208V AC/230V AC/460V AC, Three Phase
     
    NEMA 56C—Totally Enclosed Nonventilated (TENV)
    1/21,8001.9 amp/1.8 amp/0.9 ampYes11 3/4"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH35661.117.9IP69
    3548N12000000000
     
    230V AC/460V AC, Three Phase
     
    NEMA 56C—Totally Enclosed Fan-Cooled (TEFC)
    23,6005.0 amp/2.5 ampYes14 7/8"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH356165.635.9IP69
    3548N2300000000
     
    NEMA 56C—Totally Enclosed Nonventilated (TENV)
    3/41,8002.2 amp/1.1 ampYes12 3/4"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH35697.226.9IP69
    3548N1400000000
    11,8003.0 amp/1.5 ampYes12 3/4"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH35611436IP69
    3548N1600000000
    1 1/23,6003.6 amp/1.8 ampYes13 5/8"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH356122.427.7IP69
    3548N1800000000
     
    NEMA 145TC—Totally Enclosed Fan-Cooled (TEFC)
    33,6007.4 amp/3.7 ampYes16 1/4"9 3/4"6 3/4"7/8"2 1/8"3 1/2"KeyedH35620454IP69
    3548N2700000000
     

    Motor Cleaners

    Image of Product. Front orientation. Motor Cleaners.
    Keep electric motors and generators working efficiently by removing dirt, grease, oil, gum, and wax.
    NSF Registered K2—These cleaners are NSF registered K2 for use in food-processing environments.
    Each
    Solvent
    Power, Kb
    Container
    Net Wt., oz.
    Harshness
    For Use On
    For Removing
    Temp. Range,
    ° F
    Dielectric Strength,
    V/mil
    Food Industry
    Std.
    1-11
    12-Up
    Aerosol Can—Nonflammable (Solvent Based)
    12918HarshAluminum, Brass, Bronze, Ceramic, Chrome, Copper, Galvanized Steel, Stainless Steel, SteelDirt, Grease, Oil, Gum, Wax-20 to 45015,000NSF Registered K2
    3422K21000000000000
     
    back to top