McMaster-Carr logo
    Filter by
    Mounting Location
    System of Measurement
    Shaft Diameter
    Attribute Image
    Electrical Phase
    Frequency
    Speed @ Continuous Operating Torque
    Shaft Type
    Insulation Class
    Power @ Maximum Speed
    Shaft Length
    Attribute Image
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    22 Products

    Base/Face-Mount DC Motors

    Image of Product. Front orientation. Electric Motors. Base/Face-Mount DC Motors , Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure.

    Totally Enclosed Fan-Cooled

    (TEFC) Motor Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Base/Face-Mount DC Motors .
    Image of Attribute. Front orientation. Contains Annotated. Base/Face-Mount DC Motors .
    With two location options for any-angle mounting, you can put these motors to work in a variety of equipment configurations. Motors are rated for continuous duty and have a keyed shaft that comes with key stock. Wire for clockwise or counterclockwise rotation; instructions are included.
    Use a motor speed control (not included) to adjust motor speed. Use an AC to DC transformer (not included) to convert AC power to DC power.
    Motors
    Replacement
    Motor Brushes
    Overall
    Shaft
    Insulation
    Power,
    hp
    Speed @ Continuous
    Operating Torque, rpm
    Max. Rotation
    Speed, rpm
    Starting Torque,
    in·lbf
    Full Load
    Current
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Pkg.
    Qty.
    Pkg.
    180V DC
     
    NEMA 145TC—Totally Enclosed Fan-Cooled (TEFC)
    1 1/21,7501,819706.66.8 amp17 1/8"7 1/4"7 7/8"7/8"2 1/4"3 1/2"RemovableF3116215K84000000000265705K82000000
    22,5002,5142,135.510 amp17 1/8"7 1/4"7 7/8"7/8"2 1/4"3 1/2"RemovableF3116215K8500000000265705K8200000
     

    Air-Powered Motors

    A safe alternative to electric motors for use in harsh environments, air-powered motors are spark-free and remain cool, even under continuous load.
    NEMA 145TC Face Mount
    Image of Product. Front orientation. Air-Powered Motors. NEMA 145TC Face Mount.
    Image of Attribute. Front orientation. Contains Annotated. NEMA 145TC Face Mount.
    Image of Attribute. Front orientation. Contains Annotated. NEMA 145TC Face Mount.
    Image of Specification. Clockwise. Front orientation. Contains Annotated. Clockwise.

    Clockwise

    Image of Specification. Counterclockwise. Front orientation. Contains Annotated. Counterclockwise.

    Counterclockwise

    Face-mount motors come with a muffler to reduce noise and filter exhaust air. They bolt directly to your equipment.
    Clockwise and Counterclockwise—Motors with reversible shaft rotation can be set to turn clockwise or counterclockwise; instructions are included.
    @ Max.
    Speed
    Overall
    Shaft
    Power,
    hp
    Torque,
    in·lbf
    Max. Speed @
    Max. Pressure, rpm
    Max. Pressure,
    psi
    Max. Air Consumption,
    ft³/min
    Noise Level,
    dBA
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    (A)
    Type
    Direction of Operation
    Pipe
    Size
    Each
    51322,5001001751059 1/2"6 1/2"8 1/4"7/8"2 1/8"3 1/4"KeyedClockwise, Counterclockwise1/2
    59785K840000000
     
    NEMA 145TC Base/Face Mount
    Image of Product. Front orientation. Air-Powered Motors. NEMA 145TC Base/Face Mount.
    Image of Attribute. Front orientation. Contains Annotated. NEMA 145TC Base/Face Mount.
    Image of Attribute. Front orientation. Contains Annotated. NEMA 145TC Base/Face Mount.
    Image of Specification. Clockwise. Front orientation. Contains Annotated. Clockwise.

    Clockwise

    Image of Specification. Counterclockwise. Front orientation. Contains Annotated. Counterclockwise.

    Counterclockwise

    Base/face-mount motors bolt directly to your equipment and have an integral base for mounting.
    Clockwise and Counterclockwise—Motors with reversible shaft rotation can be set to turn clockwise or counterclockwise; instructions are included.
    @ Max.
    Speed
    Overall
    Shaft
    Power,
    hp
    Torque,
    in·lbf
    Max. Speed @
    Max. Pressure, rpm
    Max. Pressure,
    psi
    Max. Air Consumption,
    ft³/min
    Noise Level,
    dBA
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    (A)
    Type
    Direction of Operation
    Base
    Type
    Pipe
    Size
    Each
    92902,00010027511313 3/4"8"7 1/4"7/8"2 1/8"4"KeyedClockwise, CounterclockwiseWelded1 1/4
    59785K802000000000
     

    US-Made Face-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. US-Made Face-Mount AC Motors .
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. US-Made Face-Mount AC Motors .

    Motor with Totally Enclosed

    Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. US-Made Face-Mount AC Motors .
    Image of Attribute. Side1 orientation. Contains Annotated. US-Made Face-Mount AC Motors .
    Wound, wired, and assembled in the U.S. These motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. They bolt directly to gearboxes, pumps, and other machinery. These motors are more compact than base-mount motors and the direct, rigid connection to your equipment keeps them aligned. Rated for continuous duty, they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Enclosures that are open have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Inverter Rated—When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures have an external fan that blows air over the outside of the enclosure to keep the motor cool.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 145TC
    1 1/21,7604.6 amp/2.3 ampYesTotally Enclosed Fan-Cooled (TEFC)13 1/2"9 1/2"7 1/4"7/8"2 1/4"3 5/8"KeyedF3116135K7010000000005990K4040000000
    21,7605.6 amp/2.8 ampYesTotally Enclosed Fan-Cooled (TEFC)14 1/4"9 1/2"7 1/4"7/8"2 1/4"3 5/8"KeyedF3116135K702000000005990K404000000
     

    US-Made Base/Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. US-Made Base/Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. US-Made Base/Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. US-Made Base/Face-Mount AC Motors.
    Wound, wired, and assembled in the U.S. These motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. Whether you’re switching between jobs or need flexibility during installation, these motors give you a variety of mounting options. Mount the feet to a flat surface or bolt the face directly to a gearbox, pump, or other machine. You can also do both at once for added stability in applications with high loads or vibration. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, such as fans, pumps, and conveyors.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Inverter Rated—When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures have an external fan that blows air over the outside of the enclosure to keep the motor cool.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 145TC
    21,7555.8 amp/2.9 ampYesTotally Enclosed Fan-Cooled (TEFC)14 1/4"9 1/2"7 1/4"7/8"2 1/4"3 1/2"KeyedWeldedF31159845K720000000005990K4040000000
     

    Base/Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Base/Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Base/Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Base/Face-Mount AC Motors.
    Whether you’re switching between jobs or need flexibility during installation, these motors give you a variety of mounting options. Fix the feet to a flat surface or bolt the face directly to a gearbox, pump, or other machinery. You can also do both at once for added stability in applications with high loads or vibration. These motors are rated for continuous duty, so they’re often used for equipment that requires constant power, such as fans, pumps, and conveyors.
    These motors have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—A totally enclosed fan-cooled (TEFC) enclosure means you can use them in wet and dirty environments since they don’t have vents. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Inverter Rated—These motors are also inverter-rated, so you can use them with a variable frequency drive (AC motor speed control).
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 143T/NEMA 145TC
    21,7405.2 amp/2.6 ampYesTotally Enclosed Fan-Cooled (TEFC)13 7/8"9 7/8"7 1/8"7/8"2 1/4"3 1/2"KeyedWeldedF3117026N110000000
     

    Base/Face-Mount AC Brake Motors

    Image of Product. Front orientation. Electric Motors. Base/Face-Mount AC Brake Motors.
    Image of Attribute. Front orientation. Contains Annotated. Base/Face-Mount AC Brake Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Base/Face-Mount AC Brake Motors.
    When these motors lose power, a brake engages to hold your equipment’s position, unlike standard AC motors. They’re often used with conveyors to keep items in place after a power loss, and with hoists to stop them from dropping a load. Mount them from the base or face. Rated for continuous duty, these motors can run equipment that never turns off. Their shaft is keyed, and they come with key stock.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—These motors have a TEFC (totally enclosed fan-cooled) enclosure that protects better than an ODP (open dripproof) enclosure. They aren’t airtight, but they can be used in dirty, dusty, and wet environments. To keep the motor cool, the enclosure has an external fan that blows air over the outside of the motor.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 145TC
    1 1/21,7504.8 amp/2.4 ampYesTotally Enclosed Fan-Cooled (TEFC)18 1/8"8 7/8"7 1/4"7/8"2 1/4"3 1/2"KeyedWeldedB266IP43
    4954N13000000000
    21,7405.8 amp/2.9 ampYesTotally Enclosed Fan-Cooled (TEFC)18 5/8"8 7/8"7 1/4"7/8"2 1/4"3 1/2"KeyedWeldedF311IP43
    4954N1400000000
     

    Face-Mount AC Brake Motors

    Image of Product. Front orientation. Electric Motors. Face-Mount AC Brake Motors.
    Image of Product. Side1 orientation. Contains Annotated. Face-Mount AC Brake Motors.
    Image of Attribute. Front orientation. Contains Annotated. Face-Mount AC Brake Motors.
    A built-in brake engages to hold your equipment in place when these motors lose power, unlike standard AC motors. These motors are often used with conveyors to keep items in place after a power loss, and with hoists to prevent them from dropping a load. Also known as C-face motors, these bolt directly to your equipment. They’re rated for continuous duty, so they can run equipment that never turns off. Their shaft is keyed, and they come with a key stock.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—These motors have a TEFC (totally enclosed fan-cooled) enclosure that protects better than an ODP (open dripproof) enclosure. They’re not airtight, but they can be used in dirty, wet, and dusty environments. To keep the motor cool, the enclosure has an external fan that blows air over the outside of the motor.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 145TC
    1 1/21,7504.8 amp/2.4 ampYesTotally Enclosed Fan-Cooled (TEFC)18 5/8"8 7/8"7 1/4"7/8"2"3 1/2"KeyedF311IP43
    4876N13000000000
    21,7405.8 amp/2.9 ampYesTotally Enclosed Fan-Cooled (TEFC)18 3/4"8 7/8"7 1/4"7/8"2"3 1/2"KeyedF311IP43
    4876N1400000000
     

    Sanitary and Washdown Base/Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Base/Face-Mount AC Motors, Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure.
    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Base/Face-Mount AC Motors.

    Totally Enclosed Fan-Cooled

    (TEFC) Motor Enclosure

    Image of Specification. Front orientation. Contains Annotated. 9 3/4" Overall Width. Sanitary and Washdown Base/Face-Mount AC Motors.
    For versatility in food and sanitary lines, these motors mount by their feet or bolt directly to equipment to power pumps and other machines. Many features make them safe for sanitary and washdown environments: Smooth contours and a laser-marked nameplate limit where bacteria could grow. A stainless steel enclosure, epoxy resin lined interior, and IP69 rating mean they stand up to hot spraying water, chemicals, and harsh cleaners often used in food plants. A two-barrier seal on the shaft stops water from getting in. If water does seep in, drain plugs let it out.
    Rated for continuous duty, these motors run equipment that never turns off. They’re also inverter rated, so they work with variable frequency drive (VFD) to run at different speeds. You can wire for clockwise or counterclockwise rotation; instructions are included. The conduit box also rotates, so there’s no need to reroute power when connecting conduit.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan-cooled) motors have a fan that cools the housing.
    Overall
    Shaft
    Insulation
    Torque @ 460V
    AC, in·lbf
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Starting
    Torque
    Continuous Operating
    Torque
    Enclosure
    Rating
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 145TC—Totally Enclosed Fan-Cooled (TEFC)
    33,6007.4 amp/3.7 ampYes16 1/4"9 3/4"6 3/4"7/8"2 1/8"3 1/2"KeyedH35620454IP69
    3548N27000000000
     

    Programmable Base/Face-Mount Speed-Control Motors

    Image of Product. Front orientation. Electric Motors. Programmable Base/Face-Mount Speed-Control Motors.
    Image of Attribute. Front orientation. Contains Annotated. Programmable Base/Face-Mount Speed-Control Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Programmable Base/Face-Mount Speed-Control Motors.
    These speed-control motors combine a variable-frequency drive and motor into one, saving space in your control panel and reducing the amount of wiring required. Bolt them directly to gearboxes, pumps, and other machinery, or use the welded base to mount them to a surface. You can program the drive to start, stop, change speed, and reverse direction based on inputs from a PLC or sensor. These motors are often used to start or stop a conveyor based on PLC commands or vary the speed of a fan to maintain a room’s temperature.
    The shaft is keyed and comes with key stock. These motors are rated for continuous duty, so they'll run equipment that never turns off. All have automatic overload protection, which turns motors off if they become overheated and restarts them once they’ve cooled.
    An IE5 efficiency rating means these motors and drives are rated for the highest efficiency available. From partial to full output, they'll use less electricity than motors with other ratings.
    Program these motors in a number of ways. You can download the free manufacturer software to your computer and connect to the motor via Bluetooth, or you can use a PC Connection Cord to connect your motor directly to your computer's USB port. The software allows you to control or monitor the motor in real time. To integrate them into larger control systems, these motors can be programmed using Modbus-RTU and BACnet protocols.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—A TEFC (totally enclosed fan-cooled) motor enclosure protects these motors better than ODP (open dripproof) enclosures in damp and dusty environments. The external fan keeps the motor cool.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Overload Protection
    Type
    Component
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    240V AC, Single Phase
     
    NEMA 145TC
    23,4504.4 ampYesTotally Enclosed Fan-Cooled (TEFC)13 3/8"7 1/4"11 7/8"7/8"2 1/4"3 1/2"KeyedWeldedAutomaticController, MotorF311IP54
    4886N13000000000
     
    240V AC, Three Phase
     
    NEMA 145TC
    23,4504.3 ampYesTotally Enclosed Fan-Cooled (TEFC)13 3/8"7 1/4"11 7/8"7/8"2 1/4"3 1/2"KeyedWeldedAutomaticController, MotorF311IP54
    4886N1500000000
     
    Accessories for Electric Motors

    Sanitary and Washdown Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Face-Mount AC Motors, Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure.

    Totally Enclosed Fan-Cooled

    (TEFC) Motor Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Face-Mount AC Motors.
    Bolt these motors directly to conveyors and other machines to power equipment on food and sanitary lines. They help you meet Good Manufacturing Practices (GMP) since they have many features that make them safe for sanitary and washdown environments. Smooth contours and a laser-marked nameplate limit the space where bacteria could grow. They don’t have feet, so they’re easy to rinse down thoroughly. A stainless steel enclosure, epoxy resin lined interior, and IP69 rating mean they withstand hot spraying water, harsh cleaners, and sanitizers common to food plants. A two-barrier seal keeps water from getting in through the shaft. If water does seep in, drain plugs let it out.
    These motors are also called C-face motors. They’re rated for continuous duty, so they’ll run equipment that never turns off. Inverter rated, they also work with variable frequency drive (VFD) to run at different speeds. You can wire for clockwise or counterclockwise rotation; instructions are included. Their conduit box also rotates to connect conduit from any side without needing to reroute power.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan-cooled) motors have a fan that cools the housing.
    Overall
    Shaft
    Insulation
    Torque @ 460V
    AC, in·lbf
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Starting
    Torque
    Continuous Operating
    Torque
    Enclosure
    Rating
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 145TC—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    33,6007.4 amp/3.7 ampYes16 1/4"9 7/8"6 1/2"7/8"2 1/8"3 1/4"KeyedH35620454IP69
    3540N27000000000
     

    Programmable Face-Mount Speed-Control Motors

    Image of Product. Front orientation. Electric Motors. Programmable Face-Mount Speed-Control Motors.
    Image of Attribute. Front orientation. Contains Annotated. Programmable Face-Mount Speed-Control Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Programmable Face-Mount Speed-Control Motors.
    A variable-frequency drive and motor in one unit, these motors save space in your control panel and require less wiring than separate drives and motors. They bolt directly to gearboxes, pumps, and other machinery. You can program the drive to start, stop, change speed, and reverse direction based on inputs from a PLC or sensor. These motors are often used to start or stop a conveyor based on PLC commands or vary the speed of a fan to maintain a room’s temperature.
    Rated for continuous duty, these motors can run machines that require constant power.
    An IE5 efficiency rating means these motors and drives are rated for the highest efficiency available. From partial to full output, they'll use less electricity than motors with other ratings.
    Download free software to control and monitor them in real time. Connect them to your computer via Bluetooth or use a PC connection cord to plug them into a USB port. These motors also use Modbus-RTU and BACnet protocols, so you can integrate them into building and process control systems.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—These motors have totally enclosed fan-cooled (TEFC) enclosures, which don’t have vents, so you can install them in damp and dirty environments. An external fan blows air over the outside of the enclosure to keep these motors cool. All have automatic overload protection, which turns motors off if they become overheated and restarts them once they’ve cooled.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Overload Protection
    Type
    Component
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    240V AC, Single Phase
     
    NEMA 145TC
    23,4504.4 ampYesTotally Enclosed Fan-Cooled (TEFC)13 5/8"7 1/4"11 5/8"7/8"2 1/4"3.14"KeyedAutomaticController, MotorF311IP54
    7200K103000000000
     
    240V AC, Three Phase
     
    NEMA 145TC
    23,4504.3 ampYesTotally Enclosed Fan-Cooled (TEFC)13 5/8"7 1/4"11 5/8"7/8"2 1/4"3.14"KeyedAutomaticController, MotorF311IP54
    7200K10500000000
     