Filter by
Detects
Hazardous Location Protection Type
Environment
Measures
Volume (Sound) @ Distance
Electrical Connection
For Use On
Gas Leak Detected
Hazardous Location Rating
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Battery Chemistry
Display Type
Portable Multi-Gas Detectors
Detects (Measuring Range) | Volume (Sound) @ Distance | Temp. Range, ° F | Batteries Included | Hazardous Location Rating | Enclosure Rating | Each | ||
|---|---|---|---|---|---|---|---|---|
| Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL) Oxygen (0% to 30% Vol.) Carbon Monoxide (0 ppm to 1,999 ppm) Hydrogen Sulfide (0 ppm to 200 ppm) | 95 dBA @ 30 cm | -40 to 140 | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA AEx Da Ia IIC T4 Ga Ex Da Ia IIC T4 Ga | IP68 | 18995T42 | 000000000 |
Surface-Mount Multi-Gas Detectors
Detects (Trigger Point) | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Propane (420 ppm); Methane (5,000 ppm); Hydrogen (200 ppm); Carbon Monoxide (150 ppm) | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | 120 | 6 | No | 3/16" | Canada | 6631T18 | 0000000 |
Portable Multi-Gas Detectors with Probe
Detects (Measuring Range) | Volume (Sound) @ Distance | Temp. Range, ° F | Batteries Included | Includes | Tube Lg., ft. | Hazardous Location Rating | Enclosure Rating | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL) Oxygen (0% to 30% Vol.) Carbon Monoxide (0 ppm to 1,999 ppm) Hydrogen Sulfide (0 ppm to 200 ppm) | 95 dBA @ 30 cm | -40 to 140 | Yes | Sampling Probe, Tubing Assembly, Battery | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA AEx Da Ia IIC T4 Ga Ex Da Ia IIC T4 Ga | IP68 | 18995T44 | 000000000 |
Combustion Analyzers
Measurement Range | Calculated Range | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Use On | Ambient Temp., ° F | Flue Gas Temp., ° F | Flue Gas Oxygen | Carbon Monoxide, ppm | Combustion Efficiency | Carbon Dioxide | Air Free Carbon Monoxide, ppm | Excess Air | Accuracy | Batteries Included | Each | ||
| Kerosene, Natural Gas, Oil, Propane | 25 to 110 | -4 to 1,200 | 0% to 20.9% | 0 to 2,000 | 0.1% to 100% | 0% to 15% | 0 to 9,999 | 0% to 250% | ±0.3% of Oxygen Content | Yes | 3937K35 | 0000000 | |
Acoustic Imaging Gas Leak Detectors
Max. Working Distance, ft. | Freq. Measured Range, kHz | Diag. Screen Size | Directional Resolution Range | Data Connection | Wt., lb. | Housing Material | Temp. Range, ° F | Enclosure Rating | Gas Leak Detected | Batteries Included | Container Type | Includes | Features | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 650 | 2 to 130 | 5" | 1°-0.125° | Wi-Fi, USB-A | 3.2 | Plastic | 0 to 120 | IP54 | Ammonia, Argon, Carbon Dioxide, Helium, Hydrogen, Methane, Compressed Gas Leak | Yes | Plastic Carrying Case | Battery Charger, Charging Cord, Lanyard, USB Drive | Memory Storage, LED Flashlight | 7203N12 | 0000000000 |
Gas Leak Detectors for Hard-to-Reach Areas
Detection Trigger Point, ppm | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Methane (Natural Gas) | Propane | Hydrogen | Butane | Acetone | Methanol | Ammonia | Gasoline | Chlorine | Acetylene | Ethane | Ethylene | Hydrogen Sulfide | Batteries Included | Container Type | Cannot Be Sold To | Each | ||
| 5 | 5 | 5 | 5 | 50 | 50 | 20 | 1 | 1 | 50 | 5 | 500 | 5 | Yes | Plastic Carrying Case | Outside North America | 1140T14 | 0000000 | |
Infrared Refrigerant Leak Detectors
Housing Material | Gas Leak Detected | Probe Lg. | Performance | Batteries Included | Container Type | Certification | Includes | Features | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Plastic | Hydrofluorocarbon (HFC), Chlorofluorocarbon (CFC), Hydrochlorofluorocarbon (HCFC), R-22 Refrigerant, R-134A Refrigerant, R-410A Refrigerant | 17" | Easy Read | Yes | Plastic Carrying Case | CE Marked | Charging Cord, Earbuds | Built-In Probe | Outside North America | 7394N11 | 000000000 |
Refrigerant Leak Detectors
Detectors | Replacement Batteries | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Gas Leak Detected | Probe Lg. | Batteries Included | Container Type | Certification | Features | Specs. Met | Each | Pkg. Qty. | Pkg. | |||
| Hydrofluorocarbon (HFC), Chlorofluorocarbon (CFC), Hydrochlorofluorocarbon (HCFC), R-22 Refrigerant, R-134A Refrigerant, R-410A Refrigerant | 14" | Yes | Plastic Carrying Case | UL Recognized Component, CE Marked | Built-In Probe | SAE J2791, SAE J2913 | 1130T71 | 0000000 | 4 | 71455K53 | 00000 | |
Economy Gas Leak Detectors
Detectors | Replacement Batteries | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Detection Trigger Point, ppm | ||||||||||||||
Methane (Natural Gas) | Propane | Butane | Dia. | Lg. | Wt., oz. | Gas Leak Detected | Batteries Included | Features | Each | Pkg. Qty. | Pkg. | |||
| 10,000 | 10,000 | 10,000 | 1 1/4" | 7 1/2" | 4 | Butane, Methane, Propane | Yes | Wrist Strap | 1076T8 | 000000 | 4 | 71455K53 | 00000 | |
| 1,000 | 500 | — | 7/8" | 7" | 1 | Methane, Propane | Yes | Pocket Clip, Static Absorption Detector, Wrist Strap | 1076T11 | 00000 | 4 | 71455K62 | 0000 | |