About Selecting Temperature Sensors
More
Noncontact Infrared Temperature Sensors
Monitor the temperature of hazardous, sensitive, and hard-to-reach surfaces without touching them. IP or NEMA rated, these sensors are protected against dust and washdowns.
Sensors for nonmetal surfaces measure the temperature of plastics, fabrics, ceramics, and hot adhesives.
Sensors for metal surfaces measure the temperature of both solid metals, such as heating elements, and molten metals.
Sensors with a thermocouple output communicate with devices that read thermocouple signals, so they work as replacements for thermocouples with the same output type.
Sensors with a micro USB cord and terminal block connect to your computer. Use the downloadable software to change the measurement temperature range and the output scale.
Sensors with a close focus lens hone in on small, precise areas. Use them to take the temperature of chips on circuit boards, the tips on soldering irons, and other small components.
Secure your sensor with a mounting bracket or mounting stud. Mounting brackets attach to flat surfaces. Mounting studs thread into holes.
Air purges flush dust, moisture, and other contaminants from the sensor lens to prevent inaccurate readings.
Sensor | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temp. Measuring Range, °F | Min. Object Size Detected | Max. Sensing Distance | Wavelength, microns | Resolution | Accuracy | Response Time, sec. | Lg. | Dia. | Cable Lg., ft. | Input Voltage | For Panel Cutout Dia. | Thread Size | Includes | Environmental Rating | Each | |
0-5V DC, 0-10V DC, Thermocouple Type K Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
| -40° to 1,886° | 0.03" | 1.57" | 8-14 | 15:1 | ±3° F below 200° F ±1.5% above 200° F | 0.025 | 3 1/2" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus Lens | IP65 | 3889K12 | 0000000 |
| -40° to 1,886° | 0.24" | 2.6ft. | 8-14 | 15:1 | ±3° F below 200° F ±1.5% above 200° F | 0.025 | 3 1/2" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65 | 3889K41 | 000000 |
4-20 mA Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
| -58° to 1,886° | 0.03" | 1.57" | 8-14 | 15:1 | ±2° F below 200° F ±1% above 200° F | 0.014 | 1 1/8" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus Lens | IP65, NEMA 4 | 3889K13 | 000000 |
| -58° to 1,886° | 0.26" | 3.2ft. | 8-14 | 15:1 | ±2° F below 200° F ±1% above 200° F | 0.014 | 1 1/8" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65, NEMA 4 | 3889K42 | 000000 |
Thermocouple Type J Output Signal | ||||||||||||||||
Fixed Emissivity (0.95) | ||||||||||||||||
| 32° to 662° | 0.17" | 4ft. | 7-18 | 4:1 | ±6° F below 241° F ±5% between 241° F to 440° F Not Rated above 440° F | 0.35 | 3 1/2" | 3/4" | 3.25 | 12V DC-24V DC | 3/4" | 3/4"-16 | __ | IP65, NEMA 4 | 3889K111 | 000000 |
| 86° to 932° | 0.17" | 4ft. | 7-18 | 4:1 | ±10° F below 212° F ±6° F between 212° to 300° F ±2% above 300° F | 0.35 | 3 1/2" | 3/4" | 3.25 | 12V DC-24V DC | 3/4" | 3/4"-16 | __ | IP65, NEMA 4 | 3889K211 | 000000 |
Sensor | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temp. Measuring Range, °F | Min. Object Size Detected | Max. Sensing Distance | Wavelength, microns | Resolution | Accuracy | Response Time, sec. | Lg. | Dia. | Cable Lg., ft. | Input Voltage | For Panel Cutout Dia. | Thread Size | Includes | Environmental Rating | Each | |
4-20 mA Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
| 122° to 662° | 0.2" | 15.7" | 2.3 | 22:1 | ±(0.3% of Temperature Measured + 3.6° F) | 0.02 | 1 1/4" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus Lens | IP65, NEMA 4 | 3889K14 | 0000000 |
| 122° to 662° | 0.26" | 3.6ft. | 2.3 | 22:1 | ±(0.3% of Temperature Measured + 3.6° F) | 0.02 | 1 1/4" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65, NEMA 4 | 3889K43 | 000000 |
Thread | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| For Sensor Dia. | Size | Pitch, mm | Lg. | Ht. | Wd. | Dp. | Material | Each | |
| 1/2" | M12 | 1 | 1/4" | 7/8" | 3/4" | 1/2" | 303 Stainless Steel | 3889K48 | 000000 |

For Sensor Connection Thread | ||||
|---|---|---|---|---|
| Size | Pitch | Material | Each | |
| M12 | 1 mm | 303 Stainless Steel | 3889K45 | 000000 |
Clamp-On Noncontact Temperature Sensors for Pipe

Check the inside temperature of your pipe from the outside. A good choice for when contamination is a concern, these sensors don’t touch what’s inside your line. They sit on the outside, so they won’t corrode, gunk up, or break from your line's flow. A clamp makes them quick to attach and easy to reposition—there’s no need to drill into your pipe or drain your line. They have internal sensors to record the pipe’s thermal conductivity, which is used to calculate your line’s temperature. The information is sent through a 4-20 mA signal, so you can read the temperature on controllers and data loggers.
Sensors for metal pipe are preconfigured for Schedule 40 stainless steel pipe. They won’t work with plastic pipe.
Sensors for plastic pipe are preconfigured for Schedule 40 PVC pipe. They won’t work with metal pipe.
Use communication cords (sold separately) to calibrate these sensors on your computer when your pipe isn’t the default thickness or material. Download free software and material presets to help you calibrate the sensor. If you know your pipe’s thermal conductivity, you can add another material. The software also lets you monitor and log temperature.
For Pipe | M12 Male Electrical Connection | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Size | Schedule | Temperature Measuring Range, °F | Accuracy, °F | Response Time, sec. | Ht. | Wd. | Dp. | No. of Poles | Coding | Housing Material | Operating Temperature Range, °F | Environmental Rating | Each | ||
4-20 mA Output Signal | |||||||||||||||
For Metal Pipe | |||||||||||||||
| 1 | 40 | -4° to 212° | ±0.9° | 5 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon Plastic | 32° to 100° | IP67 | Male | 5780N11 | 0000000 |
| 2 | 40 | -4° to 212° | ±0.9° | 5 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon Plastic | 32° to 100° | IP67 | Male | 5780N13 | 000000 |
| 2 1/2 | 40 | -4° to 212° | ±0.9° | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon Plastic | 32° to 100° | IP67 | Male | 5780N15 | 000000 |
| 3 | 40 | -4° to 212° | ±0.9° | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon Plastic | 32° to 100° | IP67 | Male | 5780N16 | 000000 |
| 4 | 40 | -4° to 212° | ±0.9° | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon Plastic | 32° to 100° | IP67 | Male | 5780N17 | 000000 |
For Plastic Pipe | |||||||||||||||
| 1 | 40 | -4° to 212° | ±2.7° | 30 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon Plastic | 32° to 100° | IP67 | Male | 5780N12 | 000000 |
| 2 | 40 | -4° to 212° | ±2.7° | 30 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon Plastic | 32° to 100° | IP67 | Male | 5780N14 | 000000 |

| No. of Poles | USB Standard | Lg., ft. | Max. Current | Operating System Compatibility | Specifications Met | Each | |
M12 Female × USB A Male | |||||||
|---|---|---|---|---|---|---|---|
| 8 | 2.0 | 6 1/2 | 100mA | Windows 10 or Later | CE Marked | 5780N18 | 000000 |
Noncontact Temperature Sensors for Tanks
Take your tank’s internal temperature with these sensors that sit on the outside walls. Since they don’t touch your tank’s contents, they won’t cause contamination or corrode. To attach the sensor to your tank, weld the included studs to your tank's walls, or stick them on your tank using adhesive. Either way you mount them, you don’t need to drill or drain your tank, saving you from scheduled downtime.
These sensors are preconfigured for stainless steel tanks with 1/8"-thick walls. They have internal sensors to record the tank’s thermal conductivity, which is used to calculate your tank's internal temperature. The information is sent through a 4-20 mA signal, so you can read the temperature on controllers and data loggers.
Use communication cords (sold separately) to calibrate these sensors on your computer when your tank isn’t the default thickness or material. Download free software and material presets to help you calibrate the sensor. If you know your tank’s thermal conductivity, you can add another material. The software also lets you monitor and log temperature.

For Tank | M12 Male Electrical Connection | Mounting Holes | Mounting Slots | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Wall Thick. | Min. Dia., ft. | Temp. Measuring Range, °F | Accuracy, °F | Response Time, sec. | Ht. | Wd. | Dp. | No. of Poles | Coding | Housing Material | Mounting Fasteners Included | No. of | Dia. | No. of | Wd. | Environmental Rating | Each | ||
4-20 mA Output Signal | |||||||||||||||||||
| 1/8" | 2 | -4° to 212° | ±0.9° | 5 | 4 3/8" | 2 5/8" | 1 5/8" | 8 | A | Nylon Plastic | Yes | 1 | 5/16" | 1 | 5/16" | IP67 | Male | 5753N11 | 0000000 |

| No. of Poles | USB Standard | Lg., ft. | Max. Current | Operating System Compatibility | Specifications Met | Each | |
M12 Female × USB A Male | |||||||
|---|---|---|---|---|---|---|---|
| 8 | 2.0 | 6 1/2 | 100mA | Windows 10 or Later | CE Marked | 5780N18 | 000000 |
Infrared Thermometer Transmitters
Monitor the temperature of molten steel, furnaces, glass, and other hazardous surfaces without touching them. A built-in transmitter reads surface energy levels and converts them to analog and digital output values that can be read by a receiving device, such as a PLC. Because of this, you can use these transmitters for measuring and switching applications.
Adjust set points, emissivity range, and other settings on-site using the buttons on the transmitters. Connect transmitters to an IO-link controller (not included) to change settings remotely and alert you to errors on PLCs and human-machine interfaces.
Plug these transmitters into shielded M12 sockets since they're extremely prone to signal interference. These transmitters connect using two wires to send a 4-20mA current output and four wires to use the switching output and IO-link. Connect to pin 5 to utilize the test function to verify that the transmitter's signal processing is working correctly. To view transmitter wiring diagrams, select a part number and click Product Detail.
Their lenses resist scratches, which could cause transmitters to lose focus. All are IP-rated for protection against dust and low-pressure jets of water. Made of 303 stainless steel, these transmitters resist corrosion.
Transmitters can be used on all surfaces. For best results when measuring at an angle or working on round or uneven surfaces, use transmitters with laser sight.
Transmitters with a wavelength range of 0.78–1.06 microns are best for use with glass. Use transmitters with a wavelength range of 1–1.7 microns on metal, ceramics, and graphite. Transmitters with a wavelength range of 8–14 microns are useful for plastic, fabrics, food products, and other metal-free surfaces.
Add accessories to protect your infrared thermometer transmitter in hot or dirty environments. Air purges flush out dust, moisture, and other contaminants on transmitter lenses that can interfere with infrared radiation focus and cause inaccurate readings. Cooling jackets connect to a compressed air or water line to keep temperature transmitters from overheating. Protective covers prevent dirt buildup and excessive exposure to light, which can cause transmitters to lose focus. Insulating tubes prevent overheating by protecting thermometers against heat from mounting brackets or other surfaces.



Transmitters | Mounting Brackets | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Wavelength Range, microns | Temperature Range | Resolution | Accuracy | Digital Display Type | Emissivity | Response Time, sec. | Length | Diameter | Housing Material | Output Type | Each | Each | ||
Bracket Mount with Scratch-Resistant Lens | ||||||||||||||
| 0.78 - 1.06 | 932° to 4532° F/500° to 2500° C | 1° F/1° C | ±0.3% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N115 | 000000000 | 55205K13 | 000000 |
| 1 - 1.7 | 482° to 2912° F/250° to 1600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N113 | 00000000 | 55205K13 | 00000 |
| 8 - 14 | 32° to 1831° F/0° to 1000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 7 1/2" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N111 | 00000000 | 55205K13 | 00000 |
Bracket Mount with Scratch-Resistant Lens and Laser Sight | ||||||||||||||
| 1 - 1.7 | 482° to 2912° F/250° to 1600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 9 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N114 | 00000000 | 55205K13 | 00000 |
| 8 - 14 | 32° to 1831° F/0° to 1000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 8 1/8" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N112 | 00000000 | 55205K13 | 00000 |