McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    33 Products
    About Temperature Sensors
    industrial info icon

    Choose between RTDs and thermocouples based on your application's maximum temperature, duration, and environment.

    Noncontact Infrared Temperature Sensors

    Monitor the temperature of hazardous, sensitive, and hard-to-reach surfaces without touching them. IP or NEMA rated, these sensors are protected against dust and washdowns.
    Sensors with a thermocouple output communicate with devices that read thermocouple signals, so they work as replacements for thermocouples with the same output type.
    For Nonmetal Surfaces with 3.25 ft. Long Cable
    Image of Product. Front orientation. Noncontact Temperature Sensors. Noncontact Infrared Temperature Sensors, For Nonmetal.
    Sensors for nonmetal surfaces measure the temperature of plastics, fabrics, ceramics, and hot adhesives.
    3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)—Sensors with a micro USB cord and terminal block connect to your computer. Use the downloadable software to change the measurement temperature range and the output scale.
    Close Focus Lens—Sensors with a close focus lens hone in on small, precise areas. Use them to take the temperature of chips on circuit boards, the tips on soldering irons, and other small components.
    Sensor
    Temp. Measurement
    Range, ° F
    Min. Object
    Size Detected
    Max. Sensing
    Distance
    Wavelength,
    μm
    Optical
    Resolution
    Accuracy @ Temperature
    Response
    Time, sec.
    Lg.
    Dia.
    Input Voltage,
    V DC
    For Panel
    Cutout Dia.
    Thread
    Size
    Includes
    Enclosure
    Rating
    Each
    0 to 5V DC, 0 to 10V DC, Type K Thermocouple Output Signal
     
    Adjustable Emissivity (0.1 to 1.1)
    -40 to 1,8860.03"1.57"8 to 1415:1±3° F Below 200° F
    ±1.5% Above 200° F
    0.0253 1/2"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus LensIP65
    3889K120000000
    -40 to 1,8860.24"2.6 ft.8 to 1415:1±3° F Below 200° F
    ±1.5% Above 200° F
    0.0253 1/2"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)IP65
    3889K41000000
     
    4 to 20 mA Output Signal
     
    Adjustable Emissivity (0.1 to 1.1)
    -58 to 1,8860.03"1.57"8 to 1415:1±2° F Below 200° F
    ±1.5% Above 200° F
    0.0141 1/8"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus LensIP65, NEMA 4
    3889K13000000
    -58 to 1,8860.26"3.2 ft.8 to 1415:1±2° F Below 200° F
    ±1.5% Above 200° F
    0.0141 1/8"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)IP65, NEMA 4
    3889K42000000
     
    Type J Thermocouple Output Signal
     
    Fixed Emissivity (0.95)
    32 to 6620.17"4 ft.7 to 184:1±6° F Below 241° F
    ±5% Between 241° F to 440° F
    Not Rated Above 440° F
    0.353 1/2"3/4"12 to 243/4"3/4"-16
    IP65, NEMA 4
    3889K111000000
    86 to 9320.17"4 ft.7 to 184:1±10° F Below 212° F
    ±6° F Between 212° F to 300° F
    ±2% Above 300° F
    0.353 1/2"3/4"12 to 243/4"3/4"-16
    IP65, NEMA 4
    3889K211000000
     
    Accessories for Noncontact Temperature Sensors
    For Metal Surfaces with 3.25 ft. Long Cable
    Image of Product. Front orientation. Noncontact Temperature Sensors. Noncontact Infrared Temperature Sensors, For Metal.
    Sensors for metal surfaces measure the temperature of both solid metals, such as heating elements, and molten metals.
    3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)—Sensors with a micro USB cord and terminal block connect to your computer. Use the downloadable software to change the measurement temperature range and the output scale.
    Close Focus Lens—Sensors with a close focus lens hone in on small, precise areas. Use them to take the temperature of chips on circuit boards, the tips on soldering irons, and other small components.
    Sensor
    Temp. Measurement
    Range, ° F
    Min. Object
    Size Detected
    Max. Sensing
    Distance
    Wavelength,
    μm
    Optical
    Resolution
    Accuracy @ Temperature
    Response
    Time, sec.
    Lg.
    Dia.
    Input Voltage,
    V DC
    For Panel
    Cutout Dia.
    Thread
    Size
    Includes
    Enclosure
    Rating
    Each
    4 to 20 mA Output Signal
     
    Adjustable Emissivity (0.1 to 1.1)
    122 to 6620.2"15.7"2.322:1±(0.3% of Temperature Measured + 3.6° F)0.021 1/4"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus LensIP65, NEMA 4
    3889K140000000
    122 to 6620.26"3.6 ft.2.322:1±(0.3% of Temperature Measured + 3.6° F)0.021 1/4"1/2"5 to 301/2"M12 × 1 mm3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters)IP65, NEMA 4
    3889K43000000
     
    Accessories for Noncontact Temperature Sensors

    Infrared Thermometer Transmitters

    Image of Product. Front orientation. Noncontact Temperature Sensors. Infrared Thermometer Transmitters.
    Image of Specification. Front orientation. Contains Border. LED Display.
    Image of Specification. Front orientation. Contains Annotated. Digital.

    LED Display

    Monitor the temperature of molten steel, furnaces, glass, and other hazardous surfaces without touching them. A built-in transmitter reads surface energy levels and converts them to analog and digital output values that can be read by a receiving device, such as a PLC. Because of this, you can use these transmitters for measuring and switching applications.
    Adjust set points, emissivity range, and other settings on-site using the buttons on the transmitters. Connect transmitters to an IO-link controller (not included) to change settings remotely and alert you to errors on PLCs and human-machine interfaces.
    Plug these transmitters into shielded M12 sockets since they're extremely prone to signal interference. These transmitters connect using two wires to send a 4-20mA current output and four wires to use the switching output and IO-link. Connect to pin 5 to utilize the test function to verify that the transmitter's signal processing is working correctly. To view transmitter wiring diagrams, select a part number and click Product Detail.
    Their lenses resist scratches, which could cause transmitters to lose focus. All are IP-rated for protection against dust and low-pressure jets of water.
    Transmitters can be used on all surfaces.
    Add accessories to protect your infrared thermometer transmitter in hot or dirty environments.
    Laser Sight—For best results when measuring at an angle or working on round or uneven surfaces, use transmitters with laser sight.
    0.78 μm to 1.06 μm Wavelength Range—Transmitters with a wavelength range of 0.78–1.06 microns are best for use with glass.
    1 μm to 1.7 μm Wavelength Range—Use transmitters with a wavelength range of 1–1.7 microns on metal, ceramics, and graphite.
    8 μm to 14 μm Wavelength Range—Transmitters with a wavelength range of 8–14 microns are useful for plastic, fabrics, food products, and other metal-free surfaces.
    303 Stainless Steel Housing—Made of 303 stainless steel, these transmitters resist corrosion.
    Transmitters
    Brackets
    Wavelength
    Range, μm
    Temperature Range
    Resolution
    Accuracy
    Digital Display
    Type
    Emissivity
    Response
    Time, sec.
    Lg.
    Dia.
    Housing Material
    Output Type
    Each
    Each
    Bracket Mount with Scratch-Resistant Lens
    0.78 to 1.06932° F to 4,532° F/500° C to 2,500° C1° F/1° C±0.3%LED0.1 to 1.10.0028 7/16"1 3/16"303 Stainless Steel
    Digital/Analog4680N11500000000055205K13000000
    1 to 1.7482° F to 2,912° F/250° C to 1,600° C1° F/1° C±0.5%LED0.1 to 1.10.0028 7/16"1 3/16"303 Stainless Steel
    Digital/Analog4680N1130000000055205K1300000
    8 to 1432° F to 1,831° F/0° C to 1,000° C1° F/0.5° C±1%LED0.1 to 1.10.17 1/2"1 3/16"303 Stainless Steel
    Digital/Analog4680N1110000000055205K1300000
     
    Bracket Mount with Scratch-Resistant Lens and Laser Sight
    1 to 1.7482° F to 2,912° F/250° C to 1,600° C1° F/1° C±0.5%LED0.1 to 1.10.0029 7/16"1 3/16"303 Stainless Steel
    Digital/Analog4680N1140000000055205K1300000
    8 to 1432° F to 1,831° F/0° C to 1,000° C1° F/0.5° C±1%LED0.1 to 1.10.18 1/8"1 3/16"303 Stainless Steel
    Digital/Analog4680N1120000000055205K1300000
     
    Accessories for Transmitters

    Noncontact Temperature Sensors for Tanks

    Image of Product. Back orientation. Noncontact Temperature Sensors. Noncontact Temperature Sensors for Tanks.
    Take your tank’s internal temperature with these sensors that sit on the outside walls. Since they don’t touch your tank’s contents, they won’t cause contamination or corrode. To attach the sensor to your tank, weld the included studs to your tank's walls, or stick them on your tank using adhesive. Either way you mount them, you don’t need to drill or drain your tank, saving you from scheduled downtime.
    They have internal sensors to record the tank’s thermal conductivity, which is used to calculate your tank's internal temperature.
    4 mA to 20 mA Output Signal—The information is sent through a 4-20 mA signal, so you can read the temperature on controllers and data loggers.
    For 1/8" Tank Wall Thickness—These sensors are preconfigured for stainless steel tanks with ⅛"-thick walls.
    For Tank
    M12 Male
    Electrical Connection
    Mounting
    Holes
    Mounting
    Slots
    Wall
    Thk.
    Min. Dia.,
    ft.
    Temp. Measurement
    Range, ° F
    Accuracy
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    No. of
    Poles
    Coding
    Housing
    Material
    Operating
    Temp. Range, ° F
    Mounting Fasteners
    Included
    No.
    of
    Dia.
    No.
    of
    Wd.
    Enclosure
    Rating
    Electrical Connection
    Gender
    Each
    4 mA to 20 mA Output Signal
    1/8"2-4 to 212±0.9° F54 3/8"2 5/8"1 5/8"8A
    Nylon
    32 to 100Yes15/16"15/16"IP67
    Male5753N110000000
     
    Adapters

    Pocket Infrared Thermometers

    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers, Style C.
    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers, Style E.

    Style C

    Style E

    Keep these small thermometers in your pocket or toolkit to spot check the temperature of dangerous, hard-to-reach, and moving surfaces without touching them.
    Warning: These infrared thermometers are not intended for medical use.
    Adjustable Emissivity—Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
    Laser Sight—Thermometers with laser sight have a red beam of light to indicate the precise area being measured.
    Maximum Distance—Maximum working distance is the distance a one inch target can be reliably measured.
    Batteries
    Style
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Max.
    Distance
    Emissivity
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Includes
    Thermometer Features
    Enclosure
    Rating
    Certification
    Included
    Size
    No.
    of
    Each
    For Dark Surfaces
     
    Fixed Emissivity
    C-13° F to 482° F/-25° C to 250° C0.1/0.1° C±2%Not Rated9513 1/8"1 1/4"3/4"PlasticCarrying CaseMin./Max. MemoryIP65
    CE Marked
    YesCR203219212T220000000
     
    For Dark, Light, and Shiny Surfaces
     
    Adjustable Emissivity
    E32° F to 932° F/0° C to 500° C1° F/1° C±3.6° F/±2° C15 ft.0.7 to 0.9516 5/16"1 11/16"1 11/16"PlasticAutomatic Shutoff, Laser SightIP67
    CE Marked
    Yes9V16614T31000000
     

    Clamp-On Noncontact Temperature Sensors for Pipe

    Image of ProductInUse. Sensor Shown Installed (Adapter Sold Separately). Back orientation. Noncontact Temperature Sensors. Clamp-On Noncontact Temperature Sensors for Pipe.

    Sensor Shown Installed

    (Adapter Sold Separately)

    Check the inside temperature of your pipe from the outside. A good choice for when contamination is a concern, these sensors don’t touch what’s inside your line. They sit on the outside, so they won’t corrode, gunk up, or break from your line's flow. A clamp makes them quick to attach and easy to reposition—there’s no need to drill into your pipe or drain your line. They have internal sensors to record the pipe’s thermal conductivity, which is used to calculate your line’s temperature.
    4 mA to 20 mA Output Signal—The information is sent through a 4-20 mA signal, so you can read the temperature on controllers and data loggers.
    For Metal Pipes—Sensors for metal pipe are preconfigured for Schedule 40 stainless steel pipe. They won’t work with plastic pipe.
    For Plastic Pipes—Sensors for plastic pipe are preconfigured for Schedule 40 PVC pipe. They won’t work with metal pipe.
    For
    Pipe
    M12 Male
    Electrical Connection
    Size
    Schedule
    Temp. Measurement
    Range, ° F
    Accuracy
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    No. of
    Poles
    Coding
    Housing
    Material
    Operating
    Temp. Range, ° F
    Enclosure
    Rating
    Electrical Connection
    Gender
    Each
    4 mA to 20 mA Output Signal
     
    For Metal Pipes
    1
    40
    -4 to 212±0.9° F52 3/8"2 1/2"2"8A
    Nylon
    32 to 100IP67
    Male5780N110000000
    2
    40
    -4 to 212±0.9° F52 3/8"2 1/2"2"8A
    Nylon
    32 to 100IP67
    Male5780N13000000
    2 1/2
    40
    -4 to 212±0.9° F52 3/8"2 1/2"1 7/8"8A
    Nylon
    32 to 100IP67
    Male5780N15000000
    3
    40
    -4 to 212±0.9° F52 3/8"2 1/2"1 7/8"8A
    Nylon
    32 to 100IP67
    Male5780N16000000
    4
    40
    -4 to 212±0.9° F52 3/8"2 1/2"1 7/8"8A
    Nylon
    32 to 100IP67
    Male5780N17000000
     
    For Plastic Pipes
    1
    40
    -4 to 212±2.7° F302 3/8"2 1/2"2"8A
    Nylon
    32 to 100IP67
    Male5780N12000000
    2
    40
    -4 to 212±2.7° F302 3/8"2 1/2"2"8A
    Nylon
    32 to 100IP67
    Male5780N14000000
     
    Adapters
    back to top