    7 Products

    Hazardous Location Equipment-Cooling Fans

    Safely cool electronics and equipment where explosive gases could be present due to equipment failure. ATEX certified, these fans meet European standards for hazardous locations. They’re also IP rated, so they seal out dust and are protected from water if briefly submersed. All have ball bearings that decrease noise for quiet operation. Their bearings reduce heat as they run as well, extending their life.
    Square
    Image of Product. Front orientation. Fans. Hazardous Location Equipment-Cooling Fans, Square.
    Overall
    Mounting
    Airflow
    Temp. Range,
    ° F
    Volume
    Current
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole Dia.
    Enclosure
    Rating
    Certification
    Each
    100V AC to 240V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminal
    124 ft³/min0 to 15549 dBA0.18 amp4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)PlasticPlasticATEX II 3 G Ex Ec IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    7311N15000000
     
    100V AC to 240V AC, Single Phase, 50Hz/60Hz—Wire Leads
    124 ft³/min0 to 15549 dBA0.18 amp4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)PlasticPlasticATEX II 3 G Ex Ec IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    7311N1600000
     
    115V AC to 230V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminal
    50 ft³/min0 to 15543 dBA0.08 amp3.62" (92 mm)3.62" (92 mm)1.5" (38 mm)PlasticPlasticATEX II 3 G Ex nA IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    7311N2200000
    106 ft³/min0 to 15543 dBA0.08 amp4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)PlasticPlasticATEX II 3 G Ex nA IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    7311N2300000
     
    115V AC to 230V AC, Single Phase, 50Hz/60Hz—Wire Leads
    19 ft³/min0 to 15531 dBA0.04 amp2.36" (60 mm)2.36" (60 mm)0.98" (25 mm)PlasticPlasticATEX II 3 G Ex nA IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    7311N1300000
    50 ft³/min0 to 15543 dBA0.08 amp3.62" (92 mm)3.62" (92 mm)1.5" (38 mm)PlasticPlasticATEX II 3 G Ex nA IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    7311N1400000
     
    Oblong
    Image of Product. Front orientation. Fans. Hazardous Location Equipment-Cooling Fans, Oblong.
    Overall
    Mounting
    Airflow
    Temp. Range,
    ° F
    Volume
    Current
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole Dia.
    Enclosure
    Rating
    Certification
    Each
    115V AC to 230V AC, Single Phase, 50Hz/60Hz—Wire Leads
    220 ft³/min-4 to 15857 dBA0.27 amp5.91" (150 mm)6.77" (172 mm)2.01" (51 mm)AluminumPlasticATEX II 3 G Ex nA IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.16" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    7311N24000000
     