Measure how high and far your system needs to move liquid. Then compare pumps by priming methods and flow control types.
316 Stainless Steel Air-Powered Double Diaphragm Pumps for Chemicals, Fuel, and Flammable Liquids
Threaded Bottom Intake and Threaded Top Discharge
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | |||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity, cP | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | Lg. | Wd. | Ht. | Each | Each | Each | |||||
289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure | ||||||||||||||||||||
| 15 | 12 | 10 | 7 | 1/8" | 10,000 | 20 | 1/4 Female NPT | 1/2 Female NPT | 1/2 Female NPT | 9" | 10" | 10" | 41655K27 | 000000000 | 9948K58 | 0000000 | 3781K52 | 0000000 | ||
| 45 | 38 | 30 | 19 | 1/4" | 20,000 | 40 | 1/2 Female NPT | 1 Female NPT | 1 Female NPT | 13" | 10" | 13" | 41655K28 | 00000000 | 3781K68 | 000000 | 3781K47 | 000000 | ||
| 106 | 77 | 62 | 45 | 1/4" | 30,000 | 50 | 3/4 Female NPT | 1 1/2 Female NPT | 1 1/2 Female NPT | 15" | 17" | 22" | 41655K29 | 00000000 | 3781K63 | 000000 | 3781K44 | 00000000 | ||
| 150 | 104 | 76 | 53 | 1/4" | 40,000 | 100 | 3/4 Female NPT | 2 Female NPT | 2 Female NPT | 15" | 17" | 26" | 41655K31 | 00000000 | 3781K63 | 000000 | 3781K19 | 00000000 | ||
| 235 | 174 | 127 | 90 | 3/8" | 50,000 | 140 | 3/4 Female NPT | 3 Female NPT | 3 Female NPT | 17" | 20" | 32" | 41655K32 | 000000000 | 3781K63 | 000000 | 3781K39 | 00000000 | ||
Aluminum Air-Powered Double Diaphragm Pumps for Oil, Chemicals, and Fuel
Threaded Bottom Intake and Threaded Top Discharge
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | |||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity, cP | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | Lg. | Wd. | Ht. | Each | Each | Each | |||||
289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure | ||||||||||||||||||||
| 15 | 12 | 10 | 7 | 1/8" | 10,000 | 20 | 1/4 Female NPT | 1/2 Female NPT, 1/2 Female NPT | 1/2 Female NPT, 1/2 Female NPT | 9" | 10" | 12" | 9948K16 | 000000000 | 9948K58 | 0000000 | 3781K52 | 0000000 | ||
| 45 | 38 | 30 | 19 | 1/4" | 20,000 | 40 | 1/2 Female NPT | 1 Female NPT | 1 Female NPT | 13" | 10" | 13" | 9948K19 | 00000000 | 3781K68 | 000000 | 3781K47 | 000000 | ||
| 106 | 77 | 62 | 45 | 1/4" | 30,000 | 50 | 3/4 Female NPT | 1 1/2 Female NPT | 1 1/2 Female NPT | 15" | 17" | 22" | 9948K21 | 00000000 | 3781K63 | 000000 | 3781K44 | 00000000 | ||
| 150 | 104 | 76 | 53 | 1/4" | 40,000 | 100 | 3/4 Female NPT | 2 Female NPT | 2 Female NPT | 15" | 17" | 26" | 9948K23 | 00000000 | 3781K63 | 000000 | 3781K19 | 00000000 | ||
| 235 | 174 | 127 | 90 | 3/8" | 50,000 | 140 | 3/4 Female NPT | 3 Female NPT | 3 Female NPT | 17" | 20" | 32" | 9948K24 | 00000000 | 3781K63 | 000000 | 3781K39 | 00000000 | ||
Plastic Air-Powered Double Diaphragm Pumps for Oil
Threaded Bottom Intake and Threaded Top Discharge
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | |||||||||||||||||||
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity, cP | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | Lg. | Wd. | Ht. | Each | Each | Each | |||||
231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure | ||||||||||||||||||||
| 14 | 12 | 8 | 5 | 1/8" | 10,000 | 16 | 1/4 Female NPT | 1/2 Female NPT, 1 Male NPT | 1/2 Female NPT, 1 Male NPT | 7" | 10" | 12" | 4157K133 | 000000000 | 3781K72 | 0000000 | 3781K96 | 0000000 | ||
| 23 | 19 | 13 | 8 | 5/32" | 10,000 | 20 | 1/4 Female NPT | 3/4 Female NPT, 1 1/2 Male NPT | 3/4 Female NPT, 1 1/2 Male NPT | 7" | 12" | 13" | 4157K134 | 00000000 | 3781K72 | 000000 | 3781K73 | 000000 | ||
Aluminum Air-Powered Double Diaphragm Pumps for Oil, Chemicals, and Large Solids
Threaded Top Intake and Threaded Bottom Discharge
![]() | ![]() |
70 gpm Maximum Flow Rate | 140 gpm Maximum Flow Rate |
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | |||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | Lg. | Wd. | Ht. | Each | Each | Each | |||||
289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure | ||||||||||||||||||||
| 70 | 47 | 35 | 20 | 1" | Not Rated | 50 | 1/2 Female NPT | 1 Female NPT | 1 Female NPT | 11" | 17" | 16" | 8090K11 | 000000000 | 3781K58 | 0000000 | 8090K41 | 0000000 | ||
| 140 | 120 | 96 | 77 | 2" | Not Rated | 150 | 3/4 Female NPT | 2 Female NPT | 2 Female NPT | 14" | 22" | 20" | 8090K22 | 00000000 | 3781K57 | 000000 | 3781K17 | 000000 | ||
Flanged Top Intake and Flanged Bottom Discharge
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flange | Bolt | Overall | ||||||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | OD | Thk. | Pressure Class | Circle Dia. | Hole Dia. | Lg. | Wd. | Ht. | Each | Each | Each | |||||
289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure | |||||||||||||||||||||||||
| 260 | 178 | 150 | 118 | 3" | Not Rated | 120 | 3/4 Female NPT | 3 | 3 | 7 1/2" | 7/8" | 150 | 6" | 5/8" | 16" | 37" | 30" | 8090K33 | 000000000 | 3781K57 | 0000000 | 3781K22 | 000000000 | ||
PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals
Threaded Side Intake and Threaded Side Discharge
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | ||||||||||||||||
Max. Flow Rate, gpm | Max. Solids Dia. | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | Lg. | Wd. | Ht. | Each | Each | Each | |||||
231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure | ||||||||||||||||
| 6.7 | 0.08" | 9.3 | 1/8 Female NPT | 3/8 Female NPT | 3/8 Female NPT | 3 1/2" | 5 7/8" | 7 5/8" | 2925N2 | 000000000 | 2666N29 | 0000000 | 2666N22 | 0000000 | ||
| 16 | 0.16" | 29 | 1/4 Female NPT | 1/2 Female NPT | 1/2 Female NPT | 6" | 9 3/16" | 8" | 2925N3 | 00000000 | 2666N31 | 000000 | 2666N23 | 00000000 | ||
| 39 | 0.24" | 46 | 1/4 Female NPT | 1 Female NPT | 1 Female NPT | 8" | 10 7/8" | 10 3/8" | 2925N4 | 00000000 | 2666N32 | 000000 | 2666N24 | 00000000 | ||
Aluminum Air-Powered Double Diaphragm Pumps for Oil and Chemicals
Threaded Bottom Intake and Threaded Top Discharge
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | |||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity, cP | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | Lg. | Wd. | Ht. | Each | Each | Each | |||||
289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure | ||||||||||||||||||||
| 15 | 12 | 10 | 7 | 1/8" | 10,000 | 20 | 1/4 Female NPT | 1/2 Female NPT | 1/2 Female NPT | 9" | 10" | 12" | 9948K27 | 000000000 | 9948K58 | 0000000 | ——— | 0 | ||
| 45 | 38 | 30 | 19 | 1/4" | 20,000 | 40 | 1/2 Female NPT | 1 Female NPT | 1 Female NPT | 13" | 10" | 13" | 9948K18 | 00000000 | 3781K68 | 000000 | 3781K46 | 0000000 | ||
| 106 | 77 | 62 | 45 | 1/4" | 30,000 | 50 | 3/4 Female NPT | 1 1/2 Female NPT | 1 1/2 Female NPT | 15" | 17" | 22" | 9948K22 | 00000000 | 3781K63 | 000000 | 3781K43 | 000000 | ||
| 235 | 174 | 127 | 90 | 3/8" | 50,000 | 140 | 3/4 Female NPT | 3 Female NPT | 3 Female NPT | 17" | 20" | 32" | 9948K26 | 00000000 | 3781K63 | 000000 | 3781K38 | 00000000 | ||
Compact Air-Powered Double Diaphragm Pumps
Barbed Bottom Intake and Barbed Bottom Discharge
Max. Flow Rate, gpm | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 1 ft. of Head | @ 3 ft. of Head | @ 4 ft. of Head | @ 5 ft. of Head | Max. Viscosity, cP | Air Consumption, ft³/min | Air Tube Connection | Intake Tube Connection | Discharge Tube Connection | Diaphragm Material | Lg. | Wd. | Ht. | Each | |||
15 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure | |||||||||||||||||
| 5 | 5 | 3.7 | 2.9 | 1.8 | 700 | 1.75 | 1/4" Barbed Male | 1/2" Male | 1/2" Male | Fluoroelastomer | 4 9/16" | 1 13/16" | 5 13/16" | 2753N12 | 0000000 | ||
Aluminum Air-Powered Double Diaphragm Pumps for Fuel, Oil, and Large Solids
Threaded Top Intake and Threaded Bottom Discharge
![]() | ![]() |
70 gpm Maximum Flow Rate | 140 gpm Maximum Flow Rate |
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | |||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | Lg. | Wd. | Ht. | Each | Each | Each | |||||
289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure | ||||||||||||||||||||
| 70 | 47 | 35 | 20 | 1" | Not Rated | 50 | 1/2 Female NPT | 1 Female NPT | 1 Female NPT | 11" | 17" | 16" | 8090K13 | 000000000 | 3781K58 | 0000000 | 8090K42 | 000000000 | ||
| 140 | 120 | 96 | 77 | 2" | Not Rated | 150 | 3/4 Female NPT | 2 Female NPT | 2 Female NPT | 14" | 22" | 20" | 8090K25 | 00000000 | 3781K57 | 000000 | 3781K16 | 00000000 | ||
316 Stainless Steel Air-Powered Double Diaphragm Pumps for Oil, Chemicals, Fuel, and Large Solids
Threaded Top Intake and Threaded Bottom Discharge
Double Diaphragm Pumps | Air Motor Pump Repair Kits | Fluid Side Pump Repair Kits | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | |||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity | Air Consumption, ft³/min | Air Connection Size | Intake Size | Discharge Size | Lg. | Wd. | Ht. | Each | Each | Each | |||||
289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure | ||||||||||||||||||||
| 70 | 47 | 35 | 20 | 1" | Not Rated | 50 | 1/2 Female NPT | 1 Female NPT | 1 Female NPT | 11" | 17" | 16" | 2785K63 | 000000000 | 3781K58 | 0000000 | 8090K42 | 000000000 | ||
Pump Pulsation Dampers for Air-Powered Transfer Pumps
Overall | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Intake Pipe Connections (NPT) | Air Connection (NPT) | Housing Material | Dia. | Ht. | Includes | Each | |||
Threaded Bottom Intake | |||||||||
150 psi Maximum Discharge Pressure | |||||||||
| ½ Female | ⅛ Female | 316L Stainless Steel | 10 5/8" | 6 7/16" | 1 NPT to 1/2 NPT Adapter | 3062N22 | 000000000 | ||
| ¾ Female | ⅛ Female | 316L Stainless Steel | 10 5/8" | 6 7/16" | 1 NPT to 3/4 NPT Adapter | 3062N21 | 00000000 | ||
| 1 Female | ⅛ Female | 316L Stainless Steel | 10 5/8" | 6 7/16" | — | 3062N11 | 00000000 | ||
| 1 ½ Female | ⅛ Female | 316L Stainless Steel | 13 3/4" | 8 3/16" | — | 3062N12 | 00000000 | ||
| 2 Female | ⅛ Female | 316L Stainless Steel | 13 3/4" | 8 3/16" | — | 3062N13 | 00000000 | ||
Smooth-Flow Air-Powered Double Diaphragm Pumps
Barbed Bottom Intake and Barbed Top Discharge
Double Diaphragm Pumps | Air Motor Pump Repair Kits | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | ||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | Max. Viscosity, cP | Air Consumption, ft³/min | Air Tube Connection | Intake Tube Connection | Discharge Tube Connection | Diaphragm Material | Lg. | Wd. | Ht. | Each | Each | ||||
135 ft. Maximum Feet of Head—58 psi Maximum Discharge Pressure | |||||||||||||||||
| 0.6 | 0.5 | 0.4 | 2,500 | 0.48 | 1/4" Barbed Male | 3/8" Male | 3/8" Male | Buna-N | 4" | 6" | 6" | 4022K47 | 0000000 | 4022K12 | 000000 | ||
| 0.6 | 0.5 | 0.4 | 2,500 | 0.48 | 1/4" Barbed Male | 3/8" Male | 3/8" Male | Fluoroelastomer | 4" | 6" | 6" | 4022K36 | 000000 | 4022K11 | 00000 | ||
Miniature Metering Diaphragm Pumps for Chemicals
Intake | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Current, amp | Input Analog Signal | Output Analog Signal | Gender | For Tube ID | Gender | For Tube ID | For Tube OD | Lg. | Wd. | Ht. | Each | |||
12V DC—With Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
| 14 | 29 | 6 | 30 to 100 | 1.5 | 4 mA to 20 mA | 4 mA to 20 mA | Female | 1/8" | Female | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 2915N2 | 0000000 | ||
| 14 | 29 | 6 | 30 to 100 | 1.5 | 1V DC to 5V DC | — | Female | 1/8" | Female | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 2915N1 | 000000 | ||
24V DC—With Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
| 14 | 29 | 6 | 30 to 100 | 1 | 4 mA to 20 mA | 4 mA to 20 mA | Female | 1/8" | Female | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 2915N4 | 000000 | ||
| 14 | 29 | 6 | 30 to 100 | 1 | 1V DC to 5V DC | — | Female | 1/8" | Female | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 2915N3 | 000000 | ||
High-Accuracy Metering Diaphragm Pumps for Chemicals
Diaphragm Pumps | Repair Kits | Replacement Drain Valves | Replacement Flow-Adjustment Valves | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | ||||||||||||||||||||
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | ID | OD | Lg. | Wd. | Ht. | Features | Each | Each | Each | Each | ||||||
120V AC, Single Phase | |||||||||||||||||||||
Plug In | |||||||||||||||||||||
| 0.03 to 3 | 300 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 10 7/8" | 5 1/2" | 10 3/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K93 | 0000000 | 82695K39 | 0000000 | 82695K94 | 000000 | 82695K81 | 000000 | ||
| 0.05 to 5 | 250 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 10 7/8" | 5 1/2" | 10 3/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K45 | 000000 | 82695K39 | 000000 | 82695K94 | 00000 | 82695K81 | 00000 | ||
| 0.12 to 12 | 250 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 11 1/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K52 | 000000 | 82695K32 | 000000 | 82695K82 | 00000 | 82695K81 | 00000 | ||
| 0.22 to 22 | 150 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 11 1/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K53 | 000000 | 82695K33 | 000000 | 82695K82 | 00000 | 82695K81 | 00000 | ||
| 0.24 to 24 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 10 3/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K54 | 000000 | 82695K33 | 000000 | 82695K82 | 00000 | 82695K81 | 00000 | ||
| 0.42 to 42 | 150 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 11 3/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K55 | 00000000 | 82695K33 | 000000 | ——— | 0 | ——— | 0 | ||
| 0.44 to 44 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 11 1/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K56 | 00000000 | 82695K33 | 000000 | ——— | 0 | ——— | 0 | ||
| 0.94 to 94 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 3/8" | 1/2" | 11 3/4" | 5 1/2" | 11" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K57 | 00000000 | 82695K35 | 000000 | 82695K71 | 00000 | 82695K41 | 00000 | ||
| 1.2 to 120 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 3/8" | 1/2" | 12" | 6 1/4" | 11 3/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K58 | 00000000 | 82695K36 | 000000 | 82695K71 | 00000 | 82695K41 | 00000 | ||
| 1.92 to 192 | 50 | 1,000 | 35 to 150 | 11/64 | 1 | 3/8" | 1/2" | 11 1/4" | 6 1/8" | 11 3/4" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K59 | 00000000 | 82695K37 | 000000 | 82695K71 | 00000 | 82695K41 | 00000 | ||
| 2.4 to 240 | 35 | 1,000 | 35 to 150 | 11/64 | 1 | 3/8" | 1/2" | 12" | 6 1/8" | 11 3/4" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 82695K61 | 00000000 | 82695K37 | 000000 | 82695K71 | 00000 | 82695K41 | 00000 | ||
| 6 to 600 | 30 | 1,000 | 35 to 150 | 11/64 | 1 | 1/2" | 3/4" | 11 3/8" | 6 1/8" | 11" | Backflow-Prevention Valve, Foot Valve/Strainer | 82695K62 | 00000000 | 82695K38 | 000000 | 82695K42 | 000000 | ——— | 0 | ||
PVDF Long-Life Air-Powered Drum Pumps for Chemicals
Pumps | Repair Kits | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp., ° F | Intake | Discharge | |||||||||||||||||||
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, ft³/min | For Drum Opening Size | Includes | Air Connection | Connection | Pipe Size | Tube Lg. | Discharge Location | Connection | Pipe Size | Each | Each | ||||
PTFE Diaphragm | |||||||||||||||||||||
| 13 | 55 | 3,000 | 40 | 210 | 100 | 12 | 2 NPT | Drum Connector | 1/4 Female NPT | Threaded | 1/2 Female NPT | 36" | Pump Body | Threaded | 1/2 Female NPT | 2534K54 | 000000000 | 8281K111 | 0000000 | ||
Aluminum Long-Life Air-Powered Drum Pumps for Oil
Pumps | Repair Kits | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp., ° F | Intake | Discharge | |||||||||||||||||||
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, ft³/min | For Drum Opening Size | Includes | Air Connection | Connection | Pipe Size | Tube Lg. | Discharge Location | Connection | Pipe Size | Each | Each | ||||
Buna-N Diaphragm | |||||||||||||||||||||
| 31 | 55 | 8,000 | 10 | 180 | 100 | 40 | 2 NPT | Drum Connector | 1/4 Female NPT | Threaded | 3/4 Female NPT | 39" | Pump Body | Threaded | 3/4 Female NPT | 8281K13 | 000000000 | 8281K131 | 0000000 | ||
Metering Diaphragm Pumps for Coolants and Oils
Intake | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |||
120V AC, Single Phase—With Thermal Overload Protection and With Internal Relief Valve | ||||||||||||||||||
Plug In | ||||||||||||||||||
| 4.8 to 48 | 700 | 1,500 | 40 to 200 | 1/3 | 5.9 | 3/8 | NPT | Male | 3/8 | NPT | Male | 14 3/4" | 5 1/2" | 15 1/2" | 4046K53 | 000000000 | ||
| 16.8 to 168 | 900 | 1,500 | 40 to 200 | 1/3 | 5.9 | 3/8 | NPT | Male | 3/8 | NPT | Male | 14 3/4" | 5 1/2" | 15 1/2" | 4046K59 | 00000000 | ||
| 43.2 to 432 | 350 | 1,500 | 40 to 200 | 1/3 | 5.9 | 3/8 | NPT | Male | 3/8 | NPT | Male | 14 3/4" | 5 1/2" | 15 1/2" | 4046K63 | 00000000 | ||
Remote-Adjust High-Accuracy Metering Diaphragm Pumps for Chemicals
Diaphragm Pumps | Repair Kits | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | |||||||||||||||||||
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | Input Analog Signal | Output Analog Signal | Intake Tube Lg., ft. | Discharge Tube Lg., ft. | ID | OD | Lg. | Wd. | Ht. | Each | Each | ||||
120V AC, Single Phase and With LCD Display | ||||||||||||||||||||
Plug In | ||||||||||||||||||||
| 0.005 to 5 | 250 | 1,000 | 35 to 150 | 11/64 | 1 | 4 mA to 20 mA | 4 mA to 20 mA | 4 | 8 | 1/4" | 3/8" | 10 7/8" | 5 3/8" | 10 3/8" | 42855K61 | 000000000 | 82695K39 | 0000000 | ||
| 0.012 to 12 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 4 mA to 20 mA | 4 mA to 20 mA | 4 | 8 | 1/4" | 3/8" | 10 3/4" | 5 3/8" | 10 5/8" | 42855K73 | 00000000 | 82695K32 | 000000 | ||
| 0.044 to 44 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 4 mA to 20 mA | 4 mA to 20 mA | 4 | 8 | 1/4" | 3/8" | 11 1/4" | 5 3/8" | 10 5/8" | 42855K77 | 00000000 | 82695K33 | 000000 | ||
| 0.094 to 94 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 4 mA to 20 mA | 4 mA to 20 mA | 4 | 8 | 3/8" | 1/2" | 11 1/4" | 6 1/4" | 11 1/4" | 42855K79 | 00000000 | 82695K35 | 000000 | ||
| 0.24 to 240 | 35 | 1,000 | 35 to 150 | 11/64 | 1 | 4 mA to 20 mA | 4 mA to 20 mA | 4 | 8 | 3/8" | 1/2" | 11 1/4" | 6 1/8" | 11 3/4" | 42855K85 | 00000000 | 82695K37 | 000000 | ||