    25 Products

    Adjustable-Flow Easy-Stroke Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Easy-Stroke Drum Pumps for Water and Chemicals, 304 Stainless Steel Housing.

    304 Stainless

    Steel Housing

    These pumps have a selectable flow rate, so you can adjust flow for different dispensing applications. A lever handle maximizes output with each stroke for low-effort dispensing.
    Whenever working with flammable liquids, always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.
    Intake
    Flow Rate, fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    For Discharge
    Tube ID
    Spout
    Type
    Each
    304 Stainless Steel Intake Tube and 304 Stainless Steel Housing
    6, 8, 10, 1215 to 552,000Not Rated1401 1/2 NPT, 2 NPTDrum Connector1 1/8"18 1/2" to 32 1/2"11/16"Removable00000000000000
     

    Drum Pumps for Fuel and Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Fuel and Flammable Liquid.
    All of these pumps have bonding and grounding wires, while some also have an internal flame arrester, to pump fuel, cleaning solvents, and lacquer thinners.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Steel Housing—Steel pumps work with fuels and flammable liquids, but not especially aggressive and corrosive chemicals.
    316 Stainless Steel Housing—Stainless steel pumps handle aggressive and corrosive liquids that steel pumps cannot.
    For 5 gal. Containers—Pumps for 5-gallon containers have a drum connector that fits Rieke flex spouts and two screw cap adapters: 1 3/4" and 2 1/8".
    Pump Repair Kits—Repair kits include components such as gaskets and pistons.
    Drum Pumps
    Pump Repair Kits
    Intake
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Max. Temp.,
    ° F
    For Drum Opening Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Features
    Each
    Each
    Steel Housing
    45110Not Rated1 3/4", 2 1/8", 2 1/4", 2 7/8"Drum Connector, Flex Spout Adapter, Two Screw Cap Adapters (1 3/4" & 2 1/8")1/2"16"Bonding and Grounding Wires, Internal Flame Arrester0000000000000000000000000000
    855110Not Rated2 NPTDrum Connector1/2"22"Bonding and Grounding Wires, Internal Flame Arrester00000000000000000000000000
     
    316 Stainless Steel Housing
    105 to 76501402", 2 5/8"Drum Connector1 1/2"18"Bonding and Grounding Wires0000000000000———0
    2030 to 556501402"Drum Connector1 1/2"37 1/2"Bonding and Grounding Wires0000000000000———0
     

    Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals.
    Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
    316 Stainless Steel Housing—Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
    Temp.
    Intake
    Discharge
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    120V AC—Single Phase—Hardwire
     
    316 Stainless Steel Housing
    1815551,000Not Rated1751 1/39.12 NPT1 1/2"39"1"1 1/4"72"NEC Class I Divisions 1, 2 Group D
    IP55
    0000000000000000
     

    Siphon Drum Pumps

    Image of Product. Front orientation. Drum Pumps. Siphon Drum Pumps, Style A.

    Style A

    Since these pumps use suction to draw liquid out of your container, they continue dispensing once you get them started. They're often used with coolant and water.
    Temp.
    Intake
    Discharge
    Style
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Drum Pump
    Type
    Each
    A25150Not Rated14011/16"16"Tube End9/16"11/16"21"PolyethyleneSiphon000000000000
     

    Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
    48.55514300-402101/25.341 mm1 5/8"39"Pump BodyBarbed1"MaleC-UL Listed
    UL Listed
    00000000000000000000000000000000
     
    Pump Replacement Parts

    PVDF Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. PVDF Long-Life Air-Powered Drum Pumps for Chemicals.
    A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Pump Repair Kits—Repair kits include O-rings, valves, and diaphragms.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    13553,00040210100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT0000000000000000000000000000000
     

    Air-Powered Drum Pumps for Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Air-Powered Drum Pumps for Flammable Liquid.
    These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Features
    Each
    26551,100-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"39"Pump BodyBarbed1"MaleCE Marked
    Bonding and Grounding Wires, Hanger0000000000000000
    26551,100-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"47"Pump BodyBarbed1"MaleCE Marked
    Bonding and Grounding Wires, Hanger000000000000000
    53551,000-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"39"Pump BodyBarbed1"MaleCE Marked
    Bonding and Grounding Wires, Hanger000000000000000
    53551,000-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"47"Pump BodyBarbed1"MaleCE Marked
    Bonding and Grounding Wires, Hanger000000000000000
     
    Pump Replacement Parts
    back to top