    Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style B.
    Image of Product. Style C (Shown with Connector). Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style C.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style D.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style E.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style F.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style G.

    Style B

    Style C (Shown

    with Connector)

    Style D

    Style E

    Style F

    Style G

    Push the plunger to pump water, cleaners, and chemicals.
    Style B
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style B.
    Style B are for thin liquids with a maximum viscosity of 700 or 750 centipoise.
    Pumps
    Replacement
    Connectors
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    Pipe
    Size
    Each
    PVC Piston
    857504012070 mmDrum Connector3/4"13"Tube End7/16"5/8"22"PVC
    9918K1120000002 NPT9918K111000000
     
    Style C
    Image of Product. Style C (Shown with Connector). Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style C.

    Style C (Shown

    with Connector)

    Style C are rated for liquids up to 2,500 centipoise. They are often used as hand pumps and do not come with a connector. To attach them to a container, select an optional connector.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    CSM Piston
    55 to 152,500351201/2"18"Tube End7/16"9/16"9"PVC
    4938K11000000
     
    Connectors
    Style D
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style D.
    Style D are rated for liquids up to 2,500 centipoise.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    CSM Piston
    652,5003512061 mmDrum Connector1/2"14 1/2"Tube End7/16"9/16"36"PVC
    9975K13000000
    652,5003512063 mmDrum Connector1/2"14 1/2"Tube End7/16"9/16"36"PVC
    9975K1400000
    652,5003512070 mmDrum Connector1/2"14 1/2"Tube End7/16"9/16"36"PVC
    9975K1600000
     
    Style E
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style E.
    Style E are rated for liquids up to 2,500 centipoise.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    CSM Piston
    85 to 302,500351202 NPTDrum Connector1/2"18"Tube End7/16"9/16"48"PVC
    9975K17000000
     
    Viton® Fluoroelastomer Piston
    55 to 552,500351202 NPTDrum Connector9/16"36"Tube End7/16"9/16"9"PVC
    9975K1200000
     
    Style F
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style F.
    Style F are rated for liquids up to 2,500 centipoise.
    Pumps
    Connectors
    Replacement
    Connectors
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    Connection
    Each
    Pipe
    Size
    Each
    Buna-N Piston
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Vinyl Plastic9918K310000000———0———0
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Vinyl Plastic9918K35000000———0———0
     
    Viton® Fluoroelastomer Piston
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Polyethylene9918K750000002 5/8"-5 Buttress9918K450000002 NPT9918K43000000
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Polyethylene9918K760000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
    28552,500351202"Drum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Polyethylene9918K120000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
    28552,500351202"Drum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Polyethylene9918K1150000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
     
    Style G
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style G.
    Style G are for thin liquids with a maximum viscosity of 700 or 750 centipoise.
    Temp.,
    ° F
    Intake
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Each
    Polyethylene Piston
    85 to 55750401202 NPTDrum Connector5/8"32"Spout End9918K113000000
    165 to 55750401202 NPTDrum Connector5/8"32"Spout End9918K11400000
     

    Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    12V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional2.2 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K430000000
     
    24V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional1.4 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K44000000
     

    Electric Drum Pumps for Water, Oil, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps for Water, Oil, and Chemicals, Style A.
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps for Water, Oil, and Chemicals, Style B.

    Style A

    Style B

    Drain and transfer liquid more quickly and easily than hand-operated pumps and siphon pumps.
    Style A
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps for Water, Oil, and Chemicals, Style A.
    Temp.,
    ° F
    Intake
    Discharge
    Electrical
    For Container
    Size, gal.
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—Plug In—With Thermal Overload Protection
    1 to 57, 17830001500.1521 1/2"1 1/4"16"3/4"1"60"Straight Blade23420K210000000
    307, 17830001500.1521 1/2"1 1/4"40"3/4"1"60"Straight Blade23420K22000000
     
    Style B
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps for Water, Oil, and Chemicals, Style B.
    Pumps
    Repair Kits
    Temp.
    Intake
    Discharge
    Electrical
    For Container
    Size, gal.
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Connection
    No. of
    Blades
    Each
    Each
    120V AC—Single Phase—Plug In
    551771,000Not Rated1801/26.32 NPTDrum Connector1 1/2"39 1/2"1"1 1/4"60"Straight Blade32539K5800000002539K120000000
     
    Pump Replacement Parts

    Compact Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Compact Drum Pumps for Water and Chemicals, Style A.

    Style A

    Designed to move low volumes of caustic liquids in confined areas, these pumps have a thin intake tube and a small handle. They are often used to pump cleaning fluids, acid-washing solutions, and bleach.
    Style A—Style A pumps have a selectable flow rate, so you can adjust flow for different dispensing applications.
    Temp.
    Intake
    Style
    Flow Rate, fl oz/stroke
    For Container
    Size, gal.
    Max.
    Viscosity
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Spout
    Type
    Drum Pump
    Type
    Each
    A2, 4, 6, 85Not RatedNot Rated1253/4 NPT5/8"18 1/4"Spout EndFixedPlunger4368K15000000
    A2, 4, 6, 815 to 55Not RatedNot Rated1253/4 NPT, 2 NPTTwo Drum Connectors5/8"33"Spout EndFixedPlunger4368K1300000
    A4, 8, 12, 1615 to 55Not RatedNot Rated1253/4 NPT, 2 NPTTwo Drum Connectors5/8"33"Spout EndFixedPlunger4368K1400000
     

    Siphon Drum Pumps

    Image of Product. Front orientation. Drum Pumps. Siphon Drum Pumps, Style A.
    Image of Product. Front orientation. Drum Pumps. Siphon Drum Pumps, Style B.

    Style A

    Style B

    Since these pumps use suction to draw liquid out of your container, they continue dispensing once you get them started. They're often used with coolant and water.
    5 gpm to 7 gpm Flow Rate—Adjust pumps with a 5-7 gpm flow rate for different dispensing applications.
    Temp.
    Intake
    Discharge
    Style
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Drum Pump
    Type
    Each
    A25150Not Rated14011/16"16"Tube End9/16"11/16"21"PolyethyleneSiphon9894K4400000
    A515 to 5588Not Rated1402 NPTDrum Connector7/8"34"Tube End13/16"1"48"PolyethyleneSiphon4270K2100000
    A715 to 5588Not Rated1402 NPTDrum Connector1"34"Tube End13/16"1"48"PolyethyleneSiphon4270K2200000
    B5 to 75650Not Rated1402 NPS, 70 mmDrum Connector1 1/2"16"Tube End1"1 1/4"60"PVC
    Siphon4270K2400000
    B5 to 75 to 6650Not Rated1402 NPSDrum Connector1 1/2"16"Tube End1"1 1/4"60"PVC
    Siphon4270K2500000
    B5 to 715650Not Rated1402 NPSDrum Connector1 1/2"24"Tube End1"1 1/4"60"PVC
    Siphon4270K2600000
     
    Connectors

    Fixed-Flow-Rate Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Fixed-Flow-Rate Peristaltic Pumps for Chemicals.
    Also known as tubing pumps, these maintain a fixed flow rate. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount them up to 25 feet above your liquid source. All can run dry. Do not use with solids.
    Viton® Fluoroelastomer Wetted Parts—Pumps with Viton® Fluoroelastomer tubing withstand oil such as gasoline and hydraulic oil.
    Pumps
    Replacement
    Pump Heads
    Overall
    Flow Rate, gal./day
    (For Tube ID)
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp.,
    ° F
    Power
    Current,
    amp
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    115V AC, Single Phase—Plug In
     
    PVDF and Viton® Fluoroelastomer Wetted Parts
    0.02 (1/32")
    0.07 (1/16")
    0.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K211000000043045K116000000
    0.11 (1/32")
    0.34 (1/16")
    1.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21200000043045K11600000
    0.87 (1/16")
    3.53 (1/8")
    6.84 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21600000043045K12200000
    1.75 (1/16")
    7.07 (1/8")
    13.68 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21700000043045K12200000
    22.8 (3/16")
    38 (1/4")
    1550032 to 122Fractional0.525"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22200000043045K24900000
    45.6 (3/16")
    76 (1/4")
    1520032 to 122Fractional0.655"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22300000043045K24900000
    228 (3/16")
    380 (1/4")
    155032 to 122Fractional1.745"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22400000043045K24900000
     
    Replacement Pump Intake Tubes

    Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K410000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K42000000
     

    Air-Powered Drum Pumps for Water, Oil, Coolants, and Chemicals

    These pumps have a nonsparking air-powered motor for applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump. They're often used with ammonia, etching and cleaning solutions, and other caustics.
    With NPT Discharge
    Image of Product. Front orientation. Drum Pumps. Air-Powered Drum Pumps for Water, Oil, Coolants, and Chemicals, With NPT Discharge.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Gender
    Pipe
    Size
    Each
    14551,500-3030040 to 80272 NPTDrum Connector1/8 Female NPT1 1/2"39"Female3/4
    42905K740000000
    With Tube-End Discharge
    Image of Product. Front orientation. Drum Pumps. Air-Powered Drum Pumps for Water, Oil, Coolants, and Chemicals, With Tube-End Discharge.
    Temp.,
    ° F
    Intake
    Discharge
    (Tube End)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    ID
    Lg.,
    ft.
    Each
    15303003515040272 NPTDrum Connector1/4 Female NPT1 1/4"27"3/4"58165K70000000
    15553003515040272 NPTDrum Connector1/4 Female NPT1 1/4"40"3/4"58165K8000000

    High-Flow Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. High-Flow Peristaltic Pumps for Chemicals.
    For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
    Intake
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    For Tube
    ID
    Connection
    For Tube
    ID
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    120V AC, Single Phase
     
    Plug In
    2,592201,00035 to 1601/43.11/2"Barbed
    1/2"Barbed
    10"5 1/2"10"10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61)4306K64000000000
     
    Replacements for Pumps

    Precision Flow-Adjustment Valves with Push-to-Connect Fittings for Chemicals

    Insert tubing into the fittings on these valves—no heat, solder, or flux required. With a fluoroelastomer seal and a PVDF body, they can withstand aggressive and corrosive solutions in chemical-processing applications. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control. Threads and a hex nut below the handle allow you to install these valves in instrument panels. They have a nut that can be tightened to compress the packing if it leaks.
    PVDF Body
    Image of Product. Front orientation. Flow-Adjustment Valves. Precision Flow-Adjustment Valves with Push-to-Connect Fittings for Chemicals.
    Overall
    For Tube
    ID
    For Tube
    OD
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Ht.
    Lg.
    Seal Material
    Panel Cutout
    Dia.
    Packing
    Material
    Needle
    Material
    End-to-End
    Lg.
    For Use With
    Valve
    Type
    Each
    Push to Connect × Push to Connect
    1/8" 1/4" 0.3125 psi @ 140° F2 5/8"2 11/16"Fluoroelastomer
    7/8"PTFE
    PVDF2 11/16"Water, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XyleneNeedle3112N11000000
    1/4" 3/8" 0.4125 psi @ 140° F2 5/8"2 11/16"Fluoroelastomer
    7/8"PTFE
    PVDF2 11/16"Water, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XyleneNeedle3112N1200000
     

    Threaded Precision Flow-Adjustment Valves for Chemicals

    To withstand aggressive and corrosive solutions in chemical-processing applications, these valves have a fluoroelastomer seal and a plastic body. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control.
    White PVDF Body
    Image of Product. Front orientation. Flow-Adjustment Valves. Threaded Precision Flow-Adjustment Valves for Chemicals, White, Straight.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Panel Cutout
    Dia.
    Seat
    Material
    End-to-End
    Lg.
    Valve
    Type
    For Use With
    Seal Material
    Needle
    Material
    Each
    NPT Female × NPT Female
    1/4 0.64150 psi @ 70° F3001 5/16"PTFE2 1/2"NeedleWater, Oil, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol (Methyl Alcohol), Mineral Spirits, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric AcidFluoroelastomer
    Polypropylene2547N110000000
    3/8 0.72150 psi @ 70° F3001 5/16"PTFE2 1/2"NeedleWater, Oil, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol (Methyl Alcohol), Mineral Spirits, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric AcidFluoroelastomer
    Polypropylene2547N12000000
    1/2 0.79150 psi @ 70° F3001 5/16"PTFE2 1/2"NeedleWater, Oil, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol (Methyl Alcohol), Mineral Spirits, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric AcidFluoroelastomer
    Polypropylene2547N13000000
     

    Constant-Flow-Rate Gear Pumps without Motor for Oil

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps without Motor for Oil.
    A cast iron housing and steel gears allow these gear pumps to be used to dispense oil and fuel such as hydraulic oil and diesel fuel. Select your own motor to tailor them to your application. Use an air or electric motor with a coupling and belt/pulley drive. They produce a smooth flow of liquid for applications such as engine lubrication. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Required
    hp, hp
    Intake (NPT)
    Discharge (NPT)
    Overall
    Shaft
    Max. Flow Rate @
    25 psi, gpm
    Max. Flow
    Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    @ 25
    psi
    @ 100
    psi
    Pipe
    Size
    Connection
    Gender
    Pipe
    Size
    Connection
    Gender
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 1,725 rpm Maximum Motor Speed
    8.99 gpm46220020,000-20 to 4003/411/2
    ThreadedFemale1/2
    ThreadedFemale7 1/4"3 7/16"4 1/2"5/8"1 9/16"3"41915K72000000000
     

    Harsh Environment Self-Priming Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Harsh Environment Self-Priming Dewatering Pumps.
    This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
    Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Size
    Discharge Size
    Ht.
    Wd.
    Lg.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug with 8 ft. Long Cord
    5 4/5301/4"Not Rated12560 to 1801/44.21/2 NPT Female, 3/4 GHT Male1/2 NPT Female, 3/4 GHT Male9"5 5/8"7 3/8"4381K670000000
     

    Nondrip Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Nondrip Drum Pumps for Water and Chemicals.
    Image of Product. Front orientation. Pump Tap Kits. Nondrip Drum Pumps for Water and Chemicals.

    Tap Kits

    Eliminate leaks and waste with a faucet-style nondrip nozzle that quickly starts and stops flow. Pressurize your container with a few pumps of the plunger handle, and use the one-touch nozzle to manage flow. Hold down the nozzle for intermittent dispensing, open the nozzle fully for continuous flow, and close the nozzle to stop flow entirely.
    Tap Kits—Remote tap kits extend your pump's reach for transferring liquid to tanks, mixers, and sprayers.
    Pumps
    Tap Kits
    Temp.,
    ° F
    Intake
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Drum Pump
    Type
    Nozzle
    Type
    Each
    Each
    4.52 to 55270351102 NPTDrum Connector5/8"40"NozzlePlungerNondrip9743T1100000009743T930000000
     

    Precision Flow-Adjustment Valves with Barbed Fittings for Chemicals

    Image of Product. Front orientation. Flow-Adjustment Valves. Precision Flow-Adjustment Valves with Barbed Fittings for Chemicals.
    Barbs grip onto tubing, providing a secure hold. To withstand aggressive and corrosive solutions in chemical-processing applications, these valves have a PTFE seal and a PVDF body. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control. Threads and a hex nut below the handle allow you to install these valves in instrument panels. They have a nut that can be tightened to compress the packing if it leaks.
    For Tube
    ID
    For Tube
    OD
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Panel Cutout
    Dia.
    End-to-End
    Lg.
    Valve
    Type
    For Use With
    Seal
    Material
    Packing
    Material
    Needle
    Material
    Each
    Black PVDF Body
     
    Barbed × Barbed
    1/4" 3/8" 0.3125 psi @ 140° F1407/8"3 5/16"NeedleWater, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XylenePTFE
    PTFE
    PVDF3010N11000000
    3/8" 1/2" 0.3125 psi @ 140° F1407/8"3 5/16"NeedleWater, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XylenePTFE
    PTFE
    PVDF3010N1200000
    1/2"5/8" 0.4125 psi @ 140° F1407/8"3 5/16"NeedleWater, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XylenePTFE
    PTFE
    PVDF3010N1300000
     

    Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style B

    Alter the flow rate for versatile dispensing. These pumps do not include a drum connector.
    Pump Body
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style B

    Pumps
    Repair Kits
    Connectors
    Temp.
    Intake
    Discharge
    (Pump Body)
    Electrical
    Style
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Connection
    For Tube
    ID
    Connection
    No. of
    Blades
    Each
    Each
    Each
    120V AC—Single Phase—Plug In—With Thermal Overload Protection
    B0 to 3516551,500Not Rated13018.52"1 5/8"39"Barbed
    1"Straight Blade32850K350000000002850K7100000002850K62000000
    B0 to 3516551,500Not Rated13018.52"1 5/8"47"Barbed
    1"Straight Blade32850K36000000002850K710000002850K6200000
    B0 to 3516551,500Not Rated17518.52"1 1/2"39"Barbed
    1"Straight Blade32850K55000000002850K910000002850K94000000
    B0 to 3516551,500Not Rated17518.52"1 1/2"47"Barbed
    1"Straight Blade32850K56000000002850K910000002850K94000000
    B0 to 3516551,500Not Rated17518.52"1 5/8"39"Barbed
    1"Straight Blade32850K41000000002850K720000002850K6200000
     
    Pump Replacement Parts

    PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals

    With all PTFE wetted parts, these pumps offer the best chemical resistance of all our air-powered double diaphragm pumps and can handle solvents and petroleum-based fluids that PVDF pumps can’t. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All can run dry.
    Threaded Side Intake and Threaded Side Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals, Threaded Side Intake and Threaded Side Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Overall
    Max. Flow
    Rate, gpm
    Max. Solids
    Dia.
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    6.70.08"9.31/8 Female NPT3/8 Female NPT3/8 Female NPT3 1/2"5 7/8"7 5/8"2925N20000000002666N2900000002666N220000000
    160.16"291/4 Female NPT1/2 Female NPT1/2 Female NPT6"9 3/16"8"2925N3000000002666N310000002666N2300000000
    390.24"461/4 Female NPT1 Female NPT1 Female NPT8"10 7/8"10 3/8"2925N4000000002666N320000002666N2400000000
     

    Hand-Operated Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Hand-Operated Dewatering Pumps.
    Install these pumps right in your line and engage the lever handle to start pumping. They have few moving parts that can fail for an extended service life. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
    Intake
    Discharge
    Overall
    Max. Flow Rate,
    fl oz/stroke
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    For Hose
    ID
    Connection
    Gender
    For Hose
    ID
    Connection
    Gender
    Ht.
    Wd.
    Lg.
    Each
    15351/8"100,00035 to 1501"Barbed
    Male1"Barbed
    Male4 3/8"4 3/8"12 3/4"4332K31000000
    17351/8"100,00035 to 1501 1/2"Barbed
    Male1 1/2"Barbed
    Male4 1/4"4 3/8"13 1/8"4332K33000000
     

    PVDF Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. PVDF Long-Life Air-Powered Drum Pumps for Chemicals.
    A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Repair Kits—Repair kits include O-rings, valves, and diaphragms.
    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    13553,00040210100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT2534K540000000008281K1110000000
     

    Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Contains Annotated. Drum Pumps. Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals.
    A filter/lubricator ensures efficiency and reduces wear on the pump. They have a chemically resistant seal for use with hydraulic oil and motor oil in addition to acidic and alkaline liquids such as ammonia and etching and cleaning solutions. Pumps have a nonsparking motor for use in applications where electricity is unavailable or dangerous.
    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube Lg.,
    ft.
    Tube
    Material
    Features
    Each
    Each
    16552,000-2015080 to 100322 NPTDrum Connector1/4 Female NPT1 1/2"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler8243K210000000008243K620000000
    16552,0003515080 to 100322 NPTDrum Connector1/4 Female NPT1 5/8"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler8243K31000000008243K62000000
    22553303516080 to 100322 NPTDrum Connector1/4 Female NPT2"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler4296K4100000000———0
    22553303516080 to 100322 NPTDrum Connector1/4 Female NPT2"48"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler4296K4800000000———0
     
    Couplings

    High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    Designed to move 40 gallons of liquid per minute, these pumps quickly empty drum contents. They're often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions.
    Temp.,
    ° F
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—Plug In
    403035500351601/25.72 NPTDrum Connector2"27"Tube End1"1 5/16"60"PVC
    Straight Blade36800K12000000000
    405535500-202201/25.72 NPTDrum Connector2"40"Tube End1"1 5/16"60"PVC
    Straight Blade36800K3400000000
    405535500-202201/25.72 NPTDrum Connector2"48"Tube End1"1 5/16"60"PVC
    Straight Blade36800K3800000000
    405535500351601/25.72 NPTDrum Connector2"40"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1400000000
    405535500351601/25.72 NPTDrum Connector2"48"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1800000000
     
    Pump Replacement Parts

    Polypropylene Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. Polypropylene Long-Life Air-Powered Drum Pumps for Chemicals.
    The polypropylene housing provides good resistance to caustics such as ammonia, electropolishing solutions, and detergents and cleaning fluids. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/regulator to ensure efficiency and reduce wear on the pump.
    PTFE Diaphragm—Choose a pump with a PTFE diaphragm for superior resistance to a wider variety of concentrated chemicals than Santoprene.
    Repair Kits—Repair kits include components such as O-rings, valves, balls, and diaphragms.
    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    Santoprene Diaphragm
    13553,00030180100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT2534K1800000008281K460000000
    31558,00030180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT36"Pump BodyThreaded3/4 Female NPT8281K55000000008281K47000000
     
    PTFE Diaphragm
    13553,00040180100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT8281K520000008281K111000000
    28558,00040180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT36"Pump BodyThreaded3/4 Female NPT8281K57000000008281K48000000
     

    Stainless Steel Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Stainless Steel Circulation Pumps for Chemicals.
    A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    322210441001/8"501/35.6 amp/2.8 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K8100000004320K110000000
    32323220621003/32"503/410.6 amp/5.3 amp1 1/4 Female NPT3/4 Female NPT16"9"7 3/4"4320K84000000004320K14000000
    363022541001/8"501/27.6 amp/3.8 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K820000004320K12000000
    38332718591001/8"503/410.6 amp/5.3 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K830000004320K13000000
    90826335601003/32"50112.6 amp/6.3 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K95000000004320K14000000
     
    240V AC/460V AC, Three Phase—With Thermal Overload Protection
     
    Hardwire
    754715341003/16"5012.9 amp/1.4 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K96000000004320K11000000
    95805520491003/16"501 1/23.9 amp/2 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K88000000004320K13000000
    110100805828701003/32"501 1/23.9 amp/2 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K87000000004320K15000000
    11555521003/16"5025.3 amp/2.7 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K91000000004320K16000000
    1309060821003/32"5025.3 amp/2.7 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K92000000004320K17000000
    1309555791003/16"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K94000000004320K19000000
    1408555881003/32"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K93000000004320K18000000
     
    Repair Kits