McMaster-Carr logo
    Filter by
    Power Source
    Electrical Phase
    Actuation Pressure
    Outlet Thread Type
    Industrial Info Compare
    With Relief Valve
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    76 Products
    About Air Compressors
    industrial info icon

    Choose air compressors with the right pressure and airflow rates to power your tools.

    Portable Oil-Free Electric Air Compressors

    Image of Product. Front orientation. Air Compressors. Portable Oil-Free Electric Air Compressors.
    Nothing but good, clean air to power tools all around your jobsite. These compressors don’t require lubrication, so there’s no risk of oil contaminating the air or downstream filters—reducing maintenance and downtime. Compact and lightweight compared to standard air compressors, they’re easy to carry and tuck away when you’re finished.
    As single-stage compressors, they’re best for infrequent use. They require a cooling period between uses so they don’t overheat. Plug them into a standard outlet. These compressors turn on when tank pressure drops to the actuation point and off when it reaches the maximum.
    Pressure,
    psi
    Outlet
    Overall
    Max.
    Actuation
    Max. Flow Rate @ Pressure
    Tank Cap.,
    gal.
    Power,
    hp
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    No. of
    Handles
    Wt.,
    lb.
    Includes
    Each
    Intermittent Duty (45 Minutes On, 15 Minutes Off)
     
    Single Phase, 120V AC
    1501203 ft³/min @ 50 psi
    3 ft³/min @ 75 psi
    3 ft³/min @ 90 psi
    3 ft³/min @ 100 psi
    4 ft³/min @ 25 psi
    60.4510821/4
    NPT
    Female16"16"18"134Outlet Pressure Gauge
    Tank Pressure Gauge
    Two Quick-Disconnect Fittings
    9965K620000000
     

    Portable Low-Noise Oil-Free Electric Air Compressors

    Image of Product. Front orientation. Air Compressors. Portable Low-Noise Oil-Free Electric Air Compressors.
    As quiet as a ventilation fan humming, these compressors power drills, saws, and other tools without the headache. They don’t require lubrication, so there’s no risk of oil contaminating the air or downstream filters—reducing maintenance and downtime. Compact and lightweight compared to standard air compressors, use their handle to move them where you need and store them when you’re finished. As single stage compressors, they’re best for infrequent use. Plug them into a standard outlet. They turn on when tank pressure drops to the actuation point and off when it reaches the maximum.
    Continuous Duty—Compressors for continuous duty can run without a cooling period. They’re designed for applications that require a constant supply of compressed air.
    Intermittent Duty—Compressors for intermittent duty require a cooling period between uses so they don’t overheat.
    Cannot Be Sold To—Products that cannot be sold Outside the United States are restricted due to product regulations. Products that cannot be sold to Canada are restricted due to product labeling requirements.
    Pressure,
    psi
    Outlet
    Overall
    Max.
    Actuation
    Max. Flow Rate
    @ Pressure
    Tank Cap.,
    gal.
    Power,
    hp
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    No. of
    Handles
    Wt.,
    lb.
    Cannot Be Sold To
    Includes
    Each
    Intermittent Duty (30 Minutes On, 30 Minutes Off)
     
    Single Phase, 120V AC
    1351050.7 ft³/min @ 90 psi11/22.9581/4
    NPT
    Male12 7/8"14 1/2"11 1/8"127.6Outside United StatesAir Intake Filter
    One Quick-Disconnect Fitting
    Outlet Pressure Gauge
    Tank Pressure Gauge
    8796N1110000000
    1351052 ft³/min @ 90 psi216.6601/4
    NPT
    Male17 3/8"16 7/8"13 5/8"145.2Outside United StatesAir Intake Filter
    One Quick-Disconnect Fitting
    Outlet Pressure Gauge
    Tank Pressure Gauge
    8796N112000000
    1351052.6 ft³/min @ 90 psi31 1/29.1601/4
    NPT
    Male18"19"13 3/4"152.5Outside United StatesAir Intake Filter
    Outlet Pressure Gauge
    Tank Pressure Gauge
    Two Quick-Disconnect Fittings
    8796N113000000
     
    Continuous Duty
     
    Single Phase, 120V AC
    120850.53 ft³/min @ 120 psi11/32.1581/4
    BSPP
    Female12"16"13"134Air Intake Filter
    Outlet Pressure Gauge
    Tank Pressure Gauge
    8796N11400000000
    120851.2 ft³/min @ 120 psi11/25.7631/4
    BSPP
    Female12"16"13"140CanadaAir Intake Filter
    Outlet Pressure Gauge
    Tank Pressure Gauge
    8796N11500000000
     

    Oil-Free DC Electric Air Compressor/Vacuum Pumps

    Image of Product. Front orientation. Air Compressor/Vacuum Pumps. Oil-Free DC Electric Air Compressor/Vacuum Pumps, Style A.
    Image of Product. Front orientation. Air Compressor/Vacuum Pumps. Oil-Free DC Electric Air Compressor/Vacuum Pumps, Style B.

    Style A

    Style B

    Generate only as much compressed air or vacuum as you need for precise control in low-flow applications. These pumps deliver a stable output without large fluctuations, so they’re an energy efficient choice. Use a vehicle battery or a DC generator (both not included) to power them. Since they don't require lubrication, there’s no risk of oil contamination in the air.
    These pumps come with two ports: one for pressure and one for vacuum. To switch from an air compressor to a vacuum pump, disconnect from the outlet port and connect to the inlet. Make sure the outlet port is open to atmosphere or vented.
    24V DC—NPT Female Inlet and Outlet
    Image of Product. Front orientation. Air Compressor/Vacuum Pumps. Oil-Free DC Electric Air Compressor/Vacuum Pumps, Style A.

    Style A

    Style A—Style A pumps are built for rugged environments. Use them in a variety of power applications—from air brakes to septic aeration systems. Since they’re manually actuated and lack a relief valve, you’ll need to monitor their operation to prevent pressure buildup.
    Overall
    Pipe
    Size
    Controller
    Max. Pressure,
    psi
    Max. Flow Rate
    @ Pressure
    Vacuum Rating,
    in. Hg
    Power,
    hp
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Mounting
    Location
    Ht.
    Wd.
    Dp.
    Lubricant
    Req.
    Actuation
    Features
    Each
    Style A—Wire Lead Connection
     
    Without Relief Valve
    1251.14 ft³/min @ 125 psi271/221.6669 9/16"5"7 1/16"45 to 1001/4
    1/4
    Surface6 1/2"2 5/8"4"NoManualMotor Speed Controller8244N121000000000
     
    24V DC—BSPT Female Inlet and Outlet
    Image of Product. Front orientation. Air Compressor/Vacuum Pumps. Oil-Free DC Electric Air Compressor/Vacuum Pumps, Style B.

    Style B

    Style B—Style B pumps generate air for delicate suction and gripping common in robots, medical devices, and industrial automation. A digital pressure switch and relief valve automatically turn them on or off based on pressure levels. Use the included brackets to mount their controller on a 35 mm DIN rail.
    Overall
    Pipe
    Size
    Controller
    Max. Pressure,
    psi
    Max. Flow Rate
    @ Pressure
    Vacuum Rating,
    in. Hg
    Power,
    hp
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Mounting
    Location
    Ht.
    Wd.
    Dp.
    Lubricant
    Req.
    Actuation
    Features
    Each
    Style B—Lever-Clamp-Terminal Wire Connection
     
    With Relief Valve
    790.35 ft³/min @ 79 psi201/84.5556 1/16"3 15/16"5 1/4"45 to 1001/8
    1/8
    DIN Rail7 1/8"4 5/16"1 13/16"NoPressure, VacuumDigital Pressure Switch8265N122000000000
     

    Miniature Oil-Free DC Electric Air Compressor/Vacuum Pumps

    Our tiniest option—these DC-powered pumps generate compressed air or vacuum. Their low flow rate makes them a good choice for precise jobs—like medical device or electronics assembly—where too much force could damage components. Since they don't require lubrication, there’s no risk of oil contamination in the air.
    These pumps come with two ports: one for pressure and one for vacuum. To switch from an air compressor to a vacuum pump, disconnect from the outlet port and connect to the inlet. Make sure the outlet port is open to atmosphere or vented.
    Barbed Male Inlet and Outlet
    Image of Product. Front orientation. Contains SizingReference. Air Compressor/Vacuum Pumps. Miniature Oil-Free DC Electric Air Compressor/Vacuum Pumps.
    Overall
    For
    Tube ID
    Max. Pressure,
    psi
    Max. Flow Rate @ Pressure
    Vacuum Rating,
    in. Hg
    Full Load
    Current, mA
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Inlet
    Outlet
    Lubricant
    Req.
    Wire
    Connection
    Each
    12V DC
    30.019 ft³/min @ 3 psi
    0.042 ft³/min @ 0 psi
    1240451 3/4"15/16"1 5/16"0.14"0.14"NoWire Leads4404K140000000
    100.064 ft³/min @ 10 psi
    0.117 ft³/min @ 0 psi
    22442453 1/16"1 3/16"2 3/16"0.16"0.16"NoSpade Terminal4404K25000000
     
    3.5V DC to 7V DC
    20.008 ft³/min @ 2 psi
    0.013 ft³/min @ 0 psi
    1232 to 37451 5/8"11/16"1"0.12"0.12"NoWire Leads4404K12000000
     
    NPT Female Inlet and Outlet
    Image of Product. Front orientation. Contains SizingReference. Air Compressor/Vacuum Pumps. Miniature Oil-Free DC Electric Air Compressor/Vacuum Pumps.
    Overall
    Pipe
    Size
    Max. Pressure,
    psi
    Max. Flow Rate @ Pressure
    Vacuum Rating,
    in. Hg
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Inlet
    Outlet
    Lubricant
    Req.
    Wire
    Connection
    Each
    12V DC
    120.148 ft³/min @ 12 psi
    0.254 ft³/min @ 0 psi
    252.3524 7/8"1 7/8"3 1/16"1/8
    1/8
    NoWire Leads4404K290000000
     

    High-Flow Low-Pressure Compressed Air Blowers

    Also known as regenerative blowers, use these to produce high-flow compressed air with low pressure or vacuum to operate pump drives, lift tables, and conveying systems. Compressed air blowers are also used for drying, exhausting, and aeration.
    Air circulates inside the blower housing to compress air, which generates pressure or vacuum.
    Single Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Compressed Air Blowers, Single Stage.
    Single-stage blowers circulate air once and then exhaust.
    Inverter Rated—Inverter-rated blowers have a motor that can run at slow speeds without overheating, so they can be used with a motor speed control (variable frequency drive).
    Blowers
    Air Intake
    Filters
    Valves
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume
    (Sound)
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Each
    Each
    Each
    Single Phase, 120/208/230V AC
     
    NPT Female Inlet and Outlet
    1 psi
    29 in. H₂O
    27 ft³/min @ 0 psi1.9 in. Hg
    27 in. H₂O
    1/82.3 amp @ 115V AC
    1.2 amp @ 208V AC
    1.2 amp @ 230V AC
    57 dBA9"8"9"32 to 1001
    1
    9960K5100000009960K82300000009960K8210000000
    1 psi
    39 in. H₂O
    42 ft³/min @ 0 psi2.6 in. Hg
    35 in. H₂O
    1/33.8 amp @ 115V AC
    2 amp @ 208V AC
    1.9 amp @ 230V AC
    63 dBA10"9"9"32 to 1001
    1
    9960K52000000009960K8230000009960K821000000
    1 psi
    52 in. H₂O
    156 ft³/min @ 0 psi3.8 in. Hg
    51 in. H₂O
    219.7 amp @ 115V AC
    10.6 amp @ 208V AC
    9.9 amp @ 230V AC
    71 dB14"13"14"5 to 1002
    2
    4393K5100000000———04393K41000000
    2 psi
    42 in. H₂O
    52 ft³/min @ 0 psi3 in. Hg
    40 in. H₂O
    1/26 amp @ 115V AC
    3.2 amp @ 208V AC
    3 amp @ 230V AC
    68 dBA13"10"10"32 to 1001 1/4
    1 1/4
    9960K54000000009960K8240000009960K821000000
    2 psi
    52 in. H₂O
    92 ft³/min @ 0 psi3.5 in. Hg
    48 in. H₂O
    19.8 amp @ 115V AC
    5.2 amp @ 208V AC
    4.9 amp @ 230V AC
    68 dBA13"11"12"32 to 1001 1/2
    1 1/2
    9960K57000000009960K8250000009960K821000000
    2 psi
    65 in. H₂O
    127 ft³/min @ 0 psi4.4 in. Hg
    60 in. H₂O
    1 1/217.5 amp @ 115V AC
    10 amp @ 208V AC
    9 amp @ 230V AC
    74 dBA16"13"14"32 to 1001 1/2
    1 1/2
    9960K58000000009960K8250000009960K821000000
     
    Single Phase, 120/230V AC (Not Inverter Rated)
     
    BSPP Female Inlet and Outlet
    2 psi
    56 in. H₂O
    57 ft³/min @ 0 psi3.8 in. Hg
    52 in. H₂O
    1/27 amp @ 115V AC
    3.4 amp @ 230V AC
    56 dBA10"10"10"5 to 1001 1/4
    1 1/4
    1010K4100000000———0———0
    3 psi
    76 in. H₂O
    102 ft³/min @ 0 psi5.3 in. Hg
    72 in. H₂O
    1 1/216 amp @ 115V AC
    8 amp @ 230V AC
    64 dBA12"11"12"5 to 1001 1/2
    1 1/2
    1010K4200000000———0———0
     
    Three Phase, 190/230/380/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    2 psi
    56 in. H₂O
    103 ft³/min @ 0 psi4.1 in. Hg
    56 in. H₂O
    14.4 amp @ 190V AC
    3.7 amp @ 230V AC
    2.2 amp @ 380V AC
    2.1 amp @ 460V AC
    64 dBA11"11"12"32 to 1001 1/2
    1 1/2
    1010K3500000000———0———0
    3 psi
    79 in. H₂O
    150 ft³/min @ 0 psi6.5 in. Hg
    88 in. H₂O
    2 3/47.5 amp @ 190V AC
    7.3 amp @ 230V AC
    4.3 amp @ 380V AC
    4.4 amp @ 460V AC
    70 dBA14"13"15"32 to 1002
    2
    1010K3600000000———0———0
    3 psi
    92 in. H₂O
    221 ft³/min @ 0 psi7.1 in. Hg
    96 in. H₂O
    4 1/212.5 amp @ 190V AC
    12.6 amp @ 230V AC
    7.2 amp @ 380V AC
    7.3 amp @ 460V AC
    72 dBA15"15"17"32 to 1002
    2
    1010K3800000000———0———0
    4 psi
    116 in. H₂O
    150 ft³/min @ 0 psi7.7 in. Hg
    104 in. H₂O
    3 1/49.7 amp @ 190V AC
    10.3 amp @ 230V AC
    5.6 amp @ 380V AC
    6 amp @ 460V AC
    70 dBA14"13"15"32 to 1002
    2
    1010K3700000000———0———0
     
    Three Phase, 208/230/460V AC
     
    NPT Female Inlet and Outlet
    2 psi
    43 in. H₂O
    53 ft³/min @ 0 psi2.9 in. Hg
    40 in. H₂O
    1/22 amp @ 208V AC
    2 amp @ 230V AC
    1 amp @ 460V AC
    68 dBA11"10"10"32 to 1001 1/4
    1 1/4
    9960K45000000009960K8240000009960K821000000
    2 psi
    52 in. H₂O
    92 ft³/min @ 0 psi3.5 in. Hg
    48 in. H₂O
    13.4 amp @ 208V AC
    3.2 amp @ 230V AC
    1.6 amp @ 460V AC
    68 dBA13"11"12"32 to 1001 1/2
    1 1/2
    9960K56000000009960K8250000009960K821000000
    2 psi
    65 in. H₂O
    127 ft³/min @ 0 psi4.4 in. Hg
    60 in. H₂O
    1 1/25.1 amp @ 208V AC
    4.9 amp @ 230V AC
    2.5 amp @ 460V AC
    74 dBA14"13"14"32 to 1001 1/2
    1 1/2
    9960K59000000009960K8250000009960K821000000
    2 psi
    65 in. H₂O
    160 ft³/min @ 0 psi4.4 in. Hg
    60 in. H₂O
    2 1/26.6 amp @ 208V AC
    6.2 amp @ 230V AC
    3.1 amp @ 460V AC
    75 dBA15"14"14"32 to 1001 1/2
    1 1/2
    9960K6200000000———0———0
     
    Three Phase, 208/230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    1 psi
    52 in. H₂O
    156 ft³/min @ 0 psi3.8 in. Hg
    51 in. H₂O
    25.7 amp @ 208V AC
    5.7 amp @ 230V AC
    2.8 amp @ 460V AC
    71 dB14"13"14"5 to 1002
    2
    4393K5200000000———04393K41000000
    2 psi
    80 in. H₂O
    156 ft³/min @ 0 psi6.6 in. Hg
    89 in. H₂O
    38.2 amp @ 208V AC
    8.3 amp @ 230V AC
    4.1 amp @ 460V AC
    71 dB14"13"14"5 to 1002
    2
    4393K5300000000———04393K41000000
    3 psi
    110 in. H₂O
    216 ft³/min @ 0 psi8.1 in. Hg
    110 in. H₂O
    5 1/214.6 amp @ 208V AC
    15.1 amp @ 230V AC
    7.5 amp @ 460V AC
    74 dB15"15"15"5 to 1002
    2
    4393K5400000000———04393K41000000
    4 psi
    105 in. H₂O
    207 ft³/min @ 0 psi6.5 in. Hg
    88 in. H₂O
    513 amp @ 208V AC
    12 amp @ 230V AC
    6 amp @ 460V AC
    72 dBA19"15"15"32 to 1002
    2
    9960K63000000009960K8260000009960K821000000
    4 psi
    110 in. H₂O
    265 ft³/min @ 0 psi6.6 in. Hg
    90 in. H₂O
    616 amp @ 208V AC
    15 amp @ 230V AC
    7.5 amp @ 460V AC
    79 dBA17"17"18"32 to 1002
    2
    9960K64000000009960K8260000009960K821000000
    4 psi
    110 in. H₂O
    307 ft³/min @ 0 psi8.9 in. Hg
    121 in. H₂O
    7 1/219.8 amp @ 208V AC
    19.5 amp @ 230V AC
    9.7 amp @ 460V AC
    75 dBA22"18"19"5 to 1003
    3
    4393K8500000000———04393K41000000
    5 psi
    125 in. H₂O
    420 ft³/min @ 0 psi8.1 in. Hg
    110 in. H₂O
    1035 amp @ 208V AC
    29.5 amp @ 230V AC
    15 amp @ 460V AC
    78 dBA22"18"20"32 to 1002 1/2
    2 1/2
    9960K65000000009960K8270000009960K821000000
     
    Three Phase, 220/275/380/480V AC (Inverter Rated)
     
    BSPP Female Inlet and Outlet
    2 psi
    64 in. H₂O
    57 ft³/min @ 0 psi4.4 in. Hg
    60 in. H₂O
    1/22.6 amp @ 200V AC
    2.6 amp @ 275V AC
    1.5 amp @ 380V AC
    1.5 amp @ 480V AC
    56 dBA10"10"10"5 to 1001 1/4
    1 1/4
    1010K2400000000———0———0
     
    Three Phase, 230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    4 psi
    105 in. H₂O
    795 ft³/min @ 0 psi7 in. Hg
    95 in. H₂O
    1852 amp @ 230V AC
    26 amp @ 460V AC
    79 dBA29"18"20"32 to 1002 1/2
    4
    9960K66000000009960K8270000009960K82200000000
     
    Two Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Compressed Air Blowers, Two Stage.
    Two-stage blowers circulate air twice and then exhaust, creating higher pressure or vacuum than single-stage blowers with the same horsepower.
    Inverter Rated—Inverter-rated blowers have a motor that can run at slow speeds without overheating, so they can be used with a motor speed control (variable frequency drive).
    Blowers
    Valves
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume
    (Sound)
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Each
    Each
    Single Phase, 120/208/230V AC
     
    NPT Female Inlet and Outlet
    3 psi
    98 in. H₂O
    35 ft³/min @ 0 psi7.2 in. Hg
    97 in. H₂O
    3/48.3 amp @ 115V AC
    4.1 amp @ 208V AC
    4.2 amp @ 230V AC
    64 dB14"10"11"5 to 1003/4
    3/4
    4393K560000000004393K410000000
    4 psi
    120 in. H₂O
    35 ft³/min @ 0 psi8.1 in. Hg
    110 in. H₂O
    19.4 amp @ 115V AC
    5.5 amp @ 208V AC
    5 amp @ 230V AC
    64 dB16"10"11"5 to 1003/4
    3/4
    4393K58000000004393K41000000
    5 psi
    140 in. H₂O
    65 ft³/min @ 0 psi11.1 in. Hg
    151 in. H₂O
    219.7 amp @ 115V AC
    10.6 amp @ 208V AC
    9.9 amp @ 230V AC
    72 dB15"13"14"5 to 1001 1/4
    1 1/4
    4393K63000000004393K41000000
    5 psi
    141 in. H₂O
    81 ft³/min @ 0 psi11.1 in. Hg
    151 in. H₂O
    329.4 amp @ 115V AC
    16.6 amp @ 208V AC
    14.8 amp @ 230V AC
    73 dB15"14"15"5 to 1001 1/4
    1 1/4
    4393K65000000004393K41000000
    5 psi
    161 in. H₂O
    41 ft³/min @ 0 psi10.3 in. Hg
    140 in. H₂O
    1 1/214.6 amp @ 115V AC
    7.6 amp @ 208V AC
    7.3 amp @ 230V AC
    69 dB14"11"12"5 to 1001 1/4
    1 1/4
    4393K61000000004393K41000000
     
    Three Phase, 208/230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    3 psi
    98 in. H₂O
    35 ft³/min @ 0 psi7.2 in. Hg
    97 in. H₂O
    3/42.3 amp @ 208V AC
    2.2 amp @ 230V AC
    1.3 amp @ 460V AC
    64 dB14"10"11"5 to 1003/4
    3/4
    4393K57000000004393K41000000
    4 psi
    120 in. H₂O
    35 ft³/min @ 0 psi8.1 in. Hg
    110 in. H₂O
    12.9 amp @ 208V AC
    2.9 amp @ 230V AC
    1.4 amp @ 460V AC
    64 dB16"10"11"5 to 1003/4
    3/4
    4393K59000000004393K41000000
    5 psi
    140 in. H₂O
    65 ft³/min @ 0 psi11.1 in. Hg
    151 in. H₂O
    25.8 amp @ 208V AC
    5.2 amp @ 230V AC
    2.8 amp @ 460V AC
    72 dBA16"13"14"5 to 1001 1/4
    1 1/4
    4393K47000000004393K41000000
    5 psi
    140 in. H₂O
    147 ft³/min @ 0 psi11.8 in. Hg
    160 in. H₂O
    5 1/214.6 amp @ 208V AC
    15.1 amp @ 230V AC
    7.5 amp @ 460V AC
    77 dBA17"18"19"5 to 1002
    2
    4393K87000000004393K41000000
    5 psi
    141 in. H₂O
    81 ft³/min @ 0 psi11.1 in. Hg
    151 in. H₂O
    38.3 amp @ 208V AC
    7.4 amp @ 230V AC
    4 amp @ 460V AC
    73 dBA16"14"15"5 to 1001 1/4
    1 1/4
    4393K38000000004393K41000000
    5 psi
    161 in. H₂O
    41 ft³/min @ 0 psi10.3 in. Hg
    140 in. H₂O
    1 1/24.3 amp @ 208V AC
    4.3 amp @ 230V AC
    2.1 amp @ 460V AC
    69 dB14"11"12"5 to 1001 1/4
    1 1/4
    4393K62000000004393K41000000
    6 psi
    191 in. H₂O
    65 ft³/min @ 0 psi11.1 in. Hg
    151 in. H₂O
    38.2 amp @ 208V AC
    8.3 amp @ 230V AC
    4.1 amp @ 460V AC
    73 dB15"13"14"5 to 1001 1/4
    1 1/4
    4393K64000000004393K41000000
    7 psi
    201 in. H₂O
    81 ft³/min @ 0 psi11.1 in. Hg
    151 in. H₂O
    410.9 amp @ 208V AC
    11.1 amp @ 230V AC
    5.5 amp @ 460V AC
    73 dB15"14"15"5 to 1001 1/4
    1 1/4
    4393K66000000004393K41000000
    7 psi
    200 in. H₂O
    177 ft³/min @ 0 psi13.3 in. Hg
    180 in. H₂O
    1026.1 amp @ 208V AC
    25 amp @ 230V AC
    12.5 amp @ 460V AC
    78 dBA19 1/2"19"20"5 to 1002
    2
    4393K89000000004393K41000000
    8 psi
    220 in. H₂O
    147 ft³/min @ 0 psi13.3 in. Hg
    180 in. H₂O
    7 1/219.8 amp @ 208V AC
    19.5 amp @ 230V AC
    9.7 amp @ 460V AC
    78 dBA18"18"19"5 to 1002
    2
    4393K88000000004393K41000000
     

    Portable Battery-Powered Air Compressors

    Power pneumatic tools in the shop or out in the field. Compact and lightweight, these air compressors are easy to carry and store out of the way when not in use. They automatically kick on when their tank pressure drops to the actuation point, then turn off when it reaches the maximum.
    These compressors use the same battery and chargers as other tools in your lineup. Choose from compressors with and without a battery and charger depending on your needs. You can also add an extra battery if you want a backup.
    Makita
    Image of Product. Front orientation. Air Compressors. Portable Battery-Powered Air Compressors, Makita.
    Cannot Be Sold To—Makita compressors with battery/charger included cannot be sold outside the United States due to product restrictions.
    Air Compressors
    Batteries
    Chargers
    Pressure,
    psi
    Outlet
    Overall
    Max.
    Actuation
    Max. Flow Rate
    @ Pressure
    Voltage,
    V DC
    Tank Cap.,
    gal.
    Volume (Sound),
    dBA
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Wt.,
    lb.
    Includes
    Cannot Be Sold To
    Each
    Each
    Each
    AC001GM1—Battery/Charger Included
     
    45 min. Battery Charging Time
    1351051.2 ft³/min @ 90 psi402681/4
    NPT
    Female16 1/2"15"13"23One Quick-Disconnect Fitting
    Outlet Pressure Gauge
    Start-Up Kit
    Tank Pressure Gauge
    Outside United States7780N12000000027875A102000000027875A2010000000
     
    AC001GZ—Battery/Charger Not Included
    1351051.2 ft³/min @ 90 psi402681/4
    NPT
    Female16 1/2"15"13"21One Quick-Disconnect Fitting
    Outlet Pressure Gauge
    Tank Pressure Gauge
    Outside United States7780N1500000027875A10200000027875A201000000
     
    Milwaukee
    Image of Product. Front orientation. Air Compressors. Portable Battery-Powered Air Compressors, Milwaukee.
    Air Compressors
    Batteries
    Chargers
    Pressure,
    psi
    Outlet
    Overall
    Max.
    Actuation
    Max. Flow Rate
    @ Pressure
    Voltage,
    V DC
    Tank Cap.,
    gal.
    Volume (Sound),
    dBA
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Wt.,
    lb.
    Includes
    Certification
    Each
    Pkg.
    Qty.
    Pkg.
    Each
    2840-20—Battery/Charger Included
     
    60 min. Battery Charging Time
    1351008.5 ft³/min @ 90 psi182681/4
    NPT
    Female18 1/2"16"10 1/2"33One Quick-Disconnect Fitting
    Tank Pressure Gauge
    UL Listed
    C-UL Listed
    7780N140000000129735A79000000029735A128000000
     
    2840-20—Battery/Charger Not Included
    1351008.5 ft³/min @ 90 psi182681/4
    NPT
    Female18 1/2"16"10 1/2"31One Quick-Disconnect Fitting
    Tank Pressure Gauge
    UL Listed
    C-UL Listed
    7780N13000000129735A7900000029735A12800000
     

    High-Flow Low-Pressure Hazardous Location Compressed Air Blowers

    Safely produce high-flow compressed air with low pressure or vacuum in environments with flammable gases and combustible dust, such as propane and carbon-based dust. These blowers have an explosion-proof motor and are UL listed for use in hazardous locations. Also known as regenerative blowers, they are commonly used to operate pump drives, lift tables, and conveying systems. They can also be used for drying, exhausting, and aerating.
    Single Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Hazardous Location Compressed Air Blowers.
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Hazardous Location Rating
    Each
    Three Phase, 208/230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    2 psi
    50 in. H₂O
    556 ft³/min @ 0 psi3.7 in. Hg
    50 in. H₂O
    1024.3 amp @ 208V AC
    22.4 amp @ 230V AC
    11.2 amp @ 460V AC
    8125"20"22"5 to 1004
    4
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K74000000000
    2 psi
    60 in. H₂O
    471 ft³/min @ 0 psi4.4 in. Hg
    59 in. H₂O
    1024.3 amp @ 208V AC
    22.4 amp @ 230V AC
    11.2 amp @ 460V AC
    8125"19"22"5 to 1004
    4
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7300000000
    2 psi
    68 in. H₂O
    381 ft³/min @ 0 psi5 in. Hg
    67 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    8023"18"19"5 to 1003
    3
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7200000000
    4 psi
    116 in. H₂O
    294 ft³/min @ 0 psi8.8 in. Hg
    119 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    8023"16"19"5 to 1003
    3
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7100000000
     
    Two Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Hazardous Location Compressed Air Blowers.
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Hazardous Location Rating
    Each
    Three Phase, 208/230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    3 psi
    110 in. H₂O
    220 ft³/min @ 0 psi8.1 in. Hg
    110 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    7827"19"22"5 to 1004
    4
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K77000000000
    4 psi
    115 in. H₂O
    274 ft³/min @ 0 psi8.5 in. Hg
    115 in. H₂O
    1024.3 amp @ 208V AC
    22.4 amp @ 230V AC
    11.2 amp @ 460V AC
    8127"20"22"5 to 1004
    4
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7800000000
    5 psi
    150 in. H₂O
    167 ft³/min @ 0 psi11 in. Hg
    149 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    7723"18"19"5 to 1002
    2
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7600000000
    8 psi
    240 in. H₂O
    128 ft³/min @ 0 psi11.9 in. Hg
    161 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    7527"16"19"5 to 1002
    2
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7500000000
     
    back to top