McMaster-Carr logo
    Filter by
    For Use With
    Thread Type
    Valve Position
    Body Material
    Actuation
    Maximum Pressure @ Temperature
    Mounting Position
    For Use Outdoors
    Flow Coefficient (Cv)
    Industrial Info Snippet
    Fitting Connection
    Frequency
    Valve Function
    Manual Override
    Maximum Actuator Temperature
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Compare
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    8 Products
    About Actuated On/Off Valves
    industrial info icon

    Choose the right automatic on/off valve based on power source, pressure, and flow rate.

    Anti-Water-Hammer Solenoid On/Off Valves

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Anti-Water-Hammer Solenoid On/Off Valves.
    Avoid pressure surges and system shocks that can damage piping by installing these valves that open and close slowly. They operate on electricity to automatically start and stop flow. All are fail closed unless actuated. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Rated NEMA 4X, they resist washdowns, splashing water, corrosive liquid, and dust.
    These valves are pressure drop assisted, so they require a minimum pressure drop between the inlet and the outlet for operation. The upstream pressure must be greater than the downstream pressure.
    With Manual Override—Valves with a manual override can be operated during power outages.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Each
    Brass Body with Wire Lead Connection
     
    Fail Closed—24V DC
    1/2
    FemaleNPT
    2.5150 psi @ 70° FPressure Drop Assisted, SolenoidNo35 to 185Buna-N
    2"3 9/16"NEMA 4X
    UL Listed, C-UL Listed, CSA Certified
    4241T5100000002894N19000000
    3/4
    FemaleNPT
    9.6230 psi @ 70° FPressure Drop Assisted, SolenoidYes35 to 185Buna-N
    3 15/16"4 3/4"NEMA 4X
    UL Listed, C-UL Listed, CSA Certified
    4241T520000002894N1900000
    1
    FemaleNPT
    12.5230 psi @ 70° FPressure Drop Assisted, SolenoidYes35 to 185Buna-N
    3 15/16"4 3/4"NEMA 4X
    UL Listed, C-UL Listed, CSA Certified
    4241T530000002894N1900000
     
    Fail Closed—120V AC
    3/8
    FemaleNPT
    2.5150 psi @ 70° FPressure Drop Assisted, SolenoidNo35 to 185Buna-N
    2 3/16"3 9/16"NEMA 4X
    UL Listed, C-UL Listed, CSA Certified
    4241T540000002894N1800000
    1 1/2
    FemaleNPT
    29230 psi @ 70° FPressure Drop Assisted, SolenoidYes35 to 185Buna-N
    5 1/2"5 11/16"NEMA 4X
    UL Listed, CSA Certified
    4241T45000000002894N1800000
    2
    FemaleNPT
    38.6230 psi @ 70° FPressure Drop Assisted, SolenoidYes35 to 185Buna-N
    5 15/16"6 1/4"NEMA 4X
    UL Listed, CSA Certified
    4241T46000000002894N1800000
     