    23 Products

    Panel-Mount Timer Switches

    Image of Product. 15 amp Switching Current. Front orientation. Timer Switches. Panel-Mount Timer Switches, 1 Circuit Controlled, 15 amp Switching Current.
    Image of Product. 20 amp Switching Current. Front orientation. Timer Switches. Panel-Mount Timer Switches, 1 Circuit Controlled, 20 amp Switching Current.

    15 amp Switching

    Current

    20 amp Switching

    Current

    Install these switches in a panel cutout to automatically turn electrical equipment on or off after a set interval.
    Set Time Recall—Switches with set time recall retain the last setting; push the button to start the timer over at the same interval, eliminating the need to reset the dial with every use.
    Wire
    Leads
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current
    @ Voltage
    Set Time
    Input Voltage,
    V AC
    Dia.
    Dp.
    For Panel
    Cutout Dia.
    For Max.
    Panel Thk.
    Wire Connection
    No. of
    Terminals
    No.
    of
    Lg.
    Each
    Dial Reset
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 min. to 30 min.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K610000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 hr. to 12 hr.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K63000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 hr. to 60 hr.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K65000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC2 hr. to 24 hr.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K64000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC5 min. to 60 min.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K62000000
    11 Off or 1 On
    20 amp @ 120V AC/240V AC1 min. to 15 min.120/2402 9/16"1 9/16"13/32"1/8"Screw Terminal35559N12000000
    11 Off or 1 On
    20 amp @ 120V AC/240V AC1 min. to 30 min.120/2402 3/4"1 5/8"2 19/32"1/4"Screw Terminal35559N11000000
     
    Push Reset with Set Time Recall
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 min. to 30 min.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K71000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 hr. to 12 hr.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K73000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 hr. to 60 hr.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K75000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC2 hr. to 24 hr.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K74000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC5 min. to 60 min.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"7366K72000000
     
    Replacement Knobs

    Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches, 24-Hr. Timing Cycle.
    Image of Product. Front orientation. Timer Switches. Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches, 7-Day Timing Cycle.

    24-Hr. Timing Cycle

    7-Day Timing Cycle

    Mount these switches to a flat surface or attach to DIN rail. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
    24-Hr. Timing Cycle—24-hour switches repeat the same program daily. They control two circuits and can apply a different program to each circuit.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Mounting
    For Panel
    Cutout
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    With
    Override
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    No. of
    Holes
    For DIN
    Rail Ht., mm
    Ht.
    Wd.
    Wire
    Connection
    Certification
    Each
    24-Hr. Timing Cycle—With Battery Backup
    215 amp @ 250V AC120V AC/240V AC121Push ButtonYesSPST-NO
    3.8"3.8"2.2"No2353.62"3.62"Screw TerminalUL Recognized Component, CSA Certified
    70395K710000000
     
    7-Day Timing Cycle—With Battery Backup
    115 amp @ 277V AC12V AC/24V AC/24V DC201Push ButtonYesSPDT
    4.1"2.9"2.2"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K161000000
    115 amp @ 277V AC120V AC/277V AC201Push ButtonYesSPDT
    4.1"2.9"2.2"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K171000000
    115 amp @ 277V AC120V AC/277V AC501Push ButtonYesSPDT
    4.1"2.9"2.2"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K211000000
     

    Energy-Saving Panel-Mount Timer Switches

    Image of Product. Front orientation. Timer Switches. Energy-Saving Panel-Mount Timer Switches.
    Push and release the button to activate—no electricity required.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current
    @ Voltage
    Set Time
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    No. of
    Terminals
    Dp. Behind
    Panel
    For Panel
    Cutout Dia.
    For Max.
    Panel Thk.
    Each
    11 Off or 1 On
    10 amp @ 120V AC/240V AC2 sec. to 1 min.1 7/16"1"1 1/2"Tab Terminal41 1/16"15/32"3/16"8008K330000000

    Panel-Mount Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Panel-Mount Time and Day Activated Switches.
    Install these switches in a panel cutout and program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. As UL and C-UL Recognized Components that are also CE Marked, these switches meet American, Canadian, and European safety standards.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week. They come with an override to bypass their programmed settings.
    For Panel
    Cutout
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage,
    V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time
    Timing Adjustment
    Style
    Tripper
    Type
    With
    Override
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Wire Connection
    Certification
    Each
    24-Hr. Timing Cycle
    121 amp @ 250V AC1204815 min.TripperCaptiveSPDT
    2.8"2.8"1.5"2.63"2.63"Quick-Disconnect TerminalUL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    7797K11000000
     
    7-Day Timing Cycle
    121 amp @ 250V AC12062 hr.TripperCaptiveYesSPDT
    2.8"2.8"1.5"2.63"2.63"Quick-Disconnect TerminalUL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    7797K12000000
     

    Panel-Mount Set-to-the-Minute Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Panel-Mount Set-to-the-Minute Time and Day Activated Switches, 7-Day Timing Cycle, 1 Circuit Controlled.
    Image of Product. Front orientation. Timer Switches. Panel-Mount Set-to-the-Minute Time and Day Activated Switches, 7-Day Timing Cycle, 2 Circuits Controlled.

    7-Day Timing Cycle

    1 Circuit Controlled

    7-Day Timing

    Cycle, 2 Circuits

    Controlled

    Install these switches in a panel cutout. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. The seven-day timing cycle can perform a different program each day of the week. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
    2 Circuits Controlled—Two-circuit switches can apply a different program to each circuit.
    For Panel
    Cutout
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    With
    Override
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Wire
    Connection
    Certification
    Each
    7-Day Timing Cycle—With Battery Backup
    115 amp @ 277V AC12V AC/24V AC/24V DC201Push ButtonYesSPDT
    2.8"2.8"1.5"2.63"2.63"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K910000000
    115 amp @ 277V AC120V AC/277V AC201Push ButtonYesSPDT
    2.8"2.8"1.5"2.63"2.63"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K111000000
    215 amp @ 250V AC120V AC/240V AC201Push ButtonYesSPST-NO
    2.8"2.8"2.2"2.68"2.68"Screw TerminalUL Recognized Component, CSA Certified
    70395K81000000
     
    back to top