Filter by
Measures
For Testing
Sensor Type
Meter Type
For Use With
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Certification
Battery Chemistry
Maximum Conductivity
Air Particle Counters
Battery | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures | Measurement Precision, μm | Flow Rate, ft³/min | Temp. Range, ° F | Features | Includes | Certification | Specs. Met | JIS Specification | Life, hr. | Charger Included | Batteries Included | Each | ||
| Air Particles by Volume, Air Particles Over Time | 0.3 0.5 1 2 5 10 | 0.1 | 50 to 100 | Backlit Display Isokinetic Sensor Probe Memory Storage | Carrying Case Ethernet Cable Filter Adapter Protective Cap USB Cable Zero Count Filter | CE Marked | ISO 21501 | JIS B 9921 | 10 | Yes | Yes | 5750N11 | 000000000 | |
Environmental-Monitoring Modules for Development Boards
Modules with Air Quality Sensor
Output Data | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resolution, bit | Freq., Hz | Measures | Relative Volatile Organic Compound Index | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Each | |||
I²C Communication Protocol—Qwiic Connection | |||||||||||||
| 16 | 33 | Relative Volatile Organic Compound Concentration | 0 to 500 | 1.7 to 3.6 | 0x59 | Solder | 2 | 1" | 1" | 7126N13 | 000000 | ||
Modules with Temperature, Humidity, and Air Quality Sensor
Output Data | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resolution, bit | Freq., Hz | Measures | Temp. Range, ° C | RH | Carbon Dioxide Concentration Measured, ppm | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Each | |||
I²C Communication Protocol—Qwiic Connection | |||||||||||||||
| 16 | 0.2 | Temperature, Relative Humidity, Carbon Dioxide Level | -10 to 60 | 0% to 100% | 0 to 40,000 | 2.4 to 5.5 | 0x62 | Solder | 2 | 1" | 1" | 7126N11 | 000000 | ||
Modules with Temperature, Humidity, Air Quality, and Barometer Sensor
Measures | Temp. Range, ° C | RH | Equiv. Carbon Dioxide Concentration Measured, ppm | Total Volatile Organic Compound, ppb | Barometric Pressure, in. Hg | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
I²C Communication Protocol—Qwiic Connection | |||||||||||||||
| Temperature, Relative Humidity, Equivalent Carbon Dioxide, Total Volatile Organic Compound Concentration, Air Quality Index, Barometric Pressure | 0 to 65 | 20% to 80% | 400 to 650,000 | 0 to 65,000 | 8.9 to 32.5 | 1.2 to 3.6 | 0x52 0x53 0x76 0x77 | Solder | 2 | 1" | 1" | 7126N14 | 000000 | ||
Sanitary Conductivity Sensors
Sensor | Conductivity | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., mm | Material | Dia., mm | Lg., mm | Range | Accuracy | Electrical Connection Type | Pipe Size | Thread Type | Gender | ATC Range, ° F | Enclosure Rating | Certification | Food Industry Std. | Cannot Be Sold To | Each | |||
For Use With Liquids | ||||||||||||||||||
| 37 | PEEK | 3.6 | 26 | 0 to 1,000 mS 0 to 500 mS 0 to 500 μS | ±1.5% ±1% ±1.5% | Threaded M12 Plug (Two 4-Pole Connections) | 1 | BSPP | Male | -4 to 302 | IP67, IP69K | CE Marked, EHEDG Certified | 3-A Certified 74-07, FDA Compliant 21 CFR 177.2415 | Canada | 6352N21 | 000000000 | ||
| 60 | PEEK | 3.6 | 26 | 0 to 1,000 mS 0 to 500 mS 0 to 500 μS | ±1.5% ±1% ±1.5% | Threaded M12 Plug (Two 4-Pole Connections) | 1 | BSPP | Male | -4 to 302 | IP67, IP69K | CE Marked, EHEDG Certified | 3-A Certified 74-07, FDA Compliant 21 CFR 177.2415 | Canada | 6352N22 | 00000000 | ||
Bench-Top TDS Meters
For Testing Total Dissolved Solids (TDS)
Total Dissolved Solids (TDS) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | ATC Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Each | |||
For Use With Dirty Liquids | |||||||||||
| Plastic | 0 to 50 ppm 0 to 500 ppm 0 to 5,000 ppm | ±2% | 50 to 160 | 4" | 3 1/2" | 4 1/2" | Yes | 1128T16 | 0000000 | ||
Water-Resistant Multifunction Chemistry Meters
For Testing Chlorine, Oxidation Reduction Potential (ORP), and pH
Oxidation Reduction Potential (ORP) | pH | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, mV | Accuracy | Range, pH | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean Liquids | |||||||||||||||
| Glass | -999 to 999 | ±1 mV | 0 to 14 | ±0.01 pH | 23 to 194 | IP57 | CE Marked | 6 7/8" | Yes | Canada | LCD | 1160T11 | 0000000 | ||
For Testing Conductivity, Salinity, and Total Dissolved Solids (TDS)
Conductivity | Salinity | Total Dissolved Solids (TDS) | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | Range, ppm | Accuracy | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean and Dirty Liquids | |||||||||||||||||||
| Plastic | 0 to 199.9 μS 200 to 1,999 μS 2 to 19.99 mS | ±2% | 0 to 99.9 | ±2% | 0 to 99.9 ppm 100 to 999 ppm 1 to 9.99 ppt | ±2% | 32 to 149 | IP57 | CE Marked | 6 3/4" | 1 3/8" | 1 5/8" | Yes | Canada | LCD | 13945T52 | 0000000 | ||
Easy-Read Bench-Top Multifunction Chemistry Meters
For Testing Conductivity, Resistivity, and Total Dissolved Solids (TDS)
Conductivity | Resistivity | Total Dissolved Solids (TDS) | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | Range | Accuracy | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean Liquids | |||||||||||||||||||
| Plastic | 0 to 9,999 μS 10 to 200 S | ±1% | 10 kohm to 30 Mohm | ±1% | 0 to 9,999 ppm 10 to 200 ppt | ±1% | 32 to 160 | IP67, NEMA 6 | CE Marked | 2 1/2" | 2 3/4" | 7 3/4" | Yes | Canada | LCD | 1134T6 | 0000000 | ||
For Testing Conductivity, Oxidation Reduction Potential (ORP), pH, Resistivity, and Total Dissolved Solids (TDS)
Conductivity | Resistivity | Oxidation Reduction Potential (ORP) | pH | Total Dissolved Solids (TDS) | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | Range | Accuracy | Range, mV | Accuracy | Range, pH | Accuracy | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean Liquids | |||||||||||||||||||||||
| Glass | 0 to 9,999 μS 10 to 200 mS | ±1% | 10 kohm to 30 Mohm | ±1% | -999 to 999 | ±1 mV | 0 to 14 | ±0.01 pH | 0 to 9,999 ppm 10 to 200 ppt | ±1% | 32 to 160 | IP67, NEMA 6 | CE Marked | 2 1/2" | 2 3/4" | 7 3/4" | Yes | Canada | LCD | 1134T8 | 000000000 | ||
Water-Resistant TDS Meters
For Testing Total Dissolved Solids (TDS)
Total Dissolved Solids (TDS) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean Liquids | |||||||||||||||
| 304 Stainless Steel | 0 ppm to 1,000 ppm | ±1.5% | 32 to 122 | IP67 | CE Marked | 7 3/8" | 1 7/8" | 1 1/2" | Yes | Canada | LCD | 13945T82 | 0000000 | ||
Bench-Top Conductivity Meters
For Testing Conductivity
Conductivity | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | ATC Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Each | |||
For Use With Dirty Liquids | |||||||||||
| Plastic | 0 to 0.5 μS 0 to 5 μS 0 to 50 μS 0 to 500 μS 0 to 5,000 μS | ±2% | 32 to 120 | 4" | 3 1/2" | 4 1/2" | Yes | 1128T14 | 0000000 | ||
| Plastic | 0 to 10 μS 0 to 100 μS 0 to 1,000 μS 0 to 10,000 μS | ±2% | 50 to 160 | 4" | 3 1/2" | 4 1/2" | Yes | 1128T137 | 000000 | ||
Bench-Top Multifunction Chemistry Meters
For Testing Conductivity and pH
Conductivity | pH | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | Range, pH | Accuracy | ATC Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Each | |||
For Use With Clean Liquids | ||||||||||||||
| Glass | 0 to 10 μS 0 to 100 μS 0 to 1,000 μS 0 to 10,000 μS | ±2% | 2 to 12 | ±0.2 pH | 50 to 160 | 4" | 3 1/2" | 4 1/2" | Yes | Canada | 13485T64 | 0000000 | ||
ORP Meters
For Testing Oxidation Reduction Potential (ORP)
Oxidation Reduction Potential (ORP) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, mV | Accuracy | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Dirty Liquids | ||||||||||||
| Plastic | -999 to 999 | ±2 mV | 7" | 1 1/2" | 1 1/2" | Yes | Canada | LCD | 1196T99 | 0000000 | ||
pH Meters
For Testing pH
pH | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, pH | Accuracy | ATC Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Dirty Liquids | |||||||||||||
| Glass | 0 to 14 | ±0.1 pH | 32 to 122 | 7" | 1 1/2" | 1 1/4" | Yes | Canada | LCD | 1196T35 | 000000 | ||
Remote-Reading Multifunction Chemistry Meters
For Testing Conductivity, Salinity, Temperature, and Total Dissolved Solids (TDS)
Conductivity | Salinity | Total Dissolved Solids (TDS) | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range | Accuracy | Range, ppt | Accuracy | Temp. Accuracy | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean and Dirty Liquids | |||||||||||||||||||
| 0 to 19.99 μS 20 to 199.9 μS 200 to 1,999 μS 2 to 19.99 mS 20 to 199.9 mS | ±1% ±1% ±1% ±1% ±1% | 0 to 100 | ±1% | ±0.9° F | 0 ppm to 0.1 ppm | ±1% | 32 to 212 | IP57 | CE Marked | 7 1/2" | 3 9/16" | 1 5/16" | Yes | Canada | LCD | 1122T12 | 0000000 | ||
For Testing Oxidation Reduction Potential (ORP), pH, and Temperature
Oxidation Reduction Potential (ORP) | pH | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range, mV | Accuracy | Range, pH | Accuracy | Temp. Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean and Dirty Liquids | |||||||||||||||||
| -1,000 to 1,000 | ±0.2% | 0 to 14 | ±0.01 pH | ±0.9° F | 32 to 212 | IP57 | CE Marked | 7 1/2" | 3 9/16" | 1 5/16" | Yes | Canada | LCD | 1122T14 | 0000000 | ||
Remote-Reading Multifunction Chemistry Meters with PC Output
For Testing Conductivity, Resistivity, Salinity, Temperature, and Total Dissolved Solids (TDS)
Conductivity | Resistivity | Salinity | Total Dissolved Solids (TDS) | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range | Accuracy | Range, Mohm | Accuracy | Range, ppt | Accuracy | Temp. Accuracy | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean and Dirty Liquids | |||||||||||||||||||||
| 0 mS to 200 mS | ±1.5% | 0 to 20 | ±1.5% | 0 to 100 | ±1.5% | ±0.9° F | 0 ppt to 100 ppt | ±0.1% | 32 to 212 | IP67 | CE Marked | 6 5/16" | 3 3/16" | 1 5/8" | Yes | Canada | LCD | 14345T44 | 000000000 | ||
Remote-Reading pH Meters
For Testing pH
Chemistry Meters | Buffer Solutions | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pH | |||||||||||||||||
Sensor Material | Range, pH | Accuracy | ATC Range, ° F | Data Connection | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Each | Each | ||||
For Use With Dirty Liquids | |||||||||||||||||
| Plastic | 0 to 14 | ±0.02 pH | 32 to 176 | Bluetooth | IP67 | CE Marked | 8 7/8" | 1" | 7/8" | Yes | Canada | 1131T51 | 000000000 | 21315T398 | 000000 | ||
Remote-Reading pH Meters with PC Output
For Testing pH and Temperature
pH | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, pH | Accuracy | ATC Range, ° F | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean Liquids | ||||||||||||||
| Plastic | -2 to 16 | ±0.01 pH | -22 to 260 | CE Marked | 6 5/16" | 3 3/16" | 1 5/8" | Yes | Canada | LCD | 14345T72 | 0000000 | ||
Water-Resistant Conductivity Meters
For Testing Conductivity
Conductivity | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean Liquids | |||||||||||||||
| 304 Stainless Steel | 0 μS to 1,999 μS | ±1.5% | 32 to 122 | IP67 | CE Marked | 7 3/8" | 1 7/8" | 1 1/2" | Yes | Canada | LCD | 13945T81 | 0000000 | ||
Water-Resistant Dissolved Oxygen Meters
For Testing Dissolved Oxygen
Dissolved Oxygen, ppm | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean Liquids | |||||||||||||||
| Plastic | 0 to 20 | 0.4 | 32 to 122 | IP57 | CE Marked | 6 7/8" | 1 3/8" | 1 5/8" | Yes | Canada | LCD | 13945T62 | 0000000 | ||
Water-Resistant ORP Meters
For Testing Oxidation Reduction Potential (ORP)
Oxidation Reduction Potential (ORP) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, mV | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Dirty Liquids | |||||||||||||||
| Glass | -1,000 to 1,000 | ±2 mV | 32 to 140 | IP67 | CE Marked | 8" | 4" | 3" | Yes | Canada | LCD | 13945T18 | 0000000 | ||
Water-Resistant pH Meters
For Testing pH
pH | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, pH | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Cannot Be Sold To | Display Type | Each | |||
For Use With Clean Liquids | |||||||||||||||
| Glass | 0 to 14 | ±0.1 pH | 32 to 122 | IP67 | CE Marked | 6 1/2" | 1 1/2" | 3/4" | Yes | Canada | LCD | 13945T12 | 0000000 | ||
For Use With Dirty Liquids | |||||||||||||||
| Glass | -2 to 16 | ±0.01 pH | 32 to 122 | IP67 | CE Marked | 7" | — | — | Yes | Canada | LCD | 13945T19 | 000000 | ||