McMaster-Carr logo
    Filter by
    Probe Type
    Thermocouple Probe Type
    For DIN Panel Cutout Size
    Number of Outputs
    Measurement Unit
    Total Number of Outputs
    Mounting Location
    Thermocouple Probe Connection
    Maximum Temperature for Type K Probe
    Number of Actuation Points
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Display Type
    Maximum Temperature for Type T Probe
    Maximum Temperature for RTD Probe
    Panel Cutout Width
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    65 Products

    Autotuning Temperature Controllers

    Ideal in systems with rapid, unpredictable, or complex temperature changes, these controllers turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. They work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. You can also manually select the PID variables. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, other settings.
    All meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open).
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1710000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K75000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K181000000
    B, E, J, K, L, N, R, S, T2Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K78000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K182000000
    B, E, J, K, N, R, S, T
    3Heating/Cooling—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO5 amp @ 110V ACThermocouple, RTDAutomatic90 to 2641 7/8"1 7/8"4 3/16"38615K71000000
    B, E, J, K, L, N, R, S, T4Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K183000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K191000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K86000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K194000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K83000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K271000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K89000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K281000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K93000000
    B, E, J, K, L, N, R, S, T4Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K282000000
    B, E, J, K, N, R, S, T
    4Heating/Cooling—2 Mechanical Relays
    Alarming—2 Mechanical Relays
    SPST-NO5 amp @ 110V ACThermocouple, RTDAutomatic90 to 2643 3/4"3 3/4"3 1/2"38615K72000000
     
    Accessories for Temperature Controllers
    Solid State Relay Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They have a longer service life than mechanical and signal relays. Use them for more precise and rapid control switching than mechanical relays.
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1720000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K76000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K184000000
    B, E, J, K, L, N, R, S, T2Heating—1 5V DC Solid State Relay
    Cooling—1 5V DC Solid State Relay
    Thermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K185000000
    B, E, J, K, L, N, R, S, T2Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K79000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K81000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K192000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K87000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K195000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K84000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K272000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K91000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K283000000
    B, E, J, K, L, N, R, S, T2Heating—1 5V DC Solid State Relay
    Cooling—1 5V DC Solid State Relay
    Thermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K284000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K94000000
    B, E, J, K, L, N, R, S, T4Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K96000000
     
    Accessories for Temperature Controllers
    Analog Signal Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1730000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K77000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K186000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling—1 4 mA to 20 mA Analog Signal
    Thermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K187000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K82000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K193000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K88000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K196000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K85000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K273000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K92000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K285000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling—1 4 mA to 20 mA Analog Signal
    Thermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K286000000
    B, E, J, K, N, R, S, T
    3Heating/Cooling—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    5 amp @ 110V ACThermocouple, RTDAutomatic90 to 2643 3/4"3 3/4"3 1/2"38615K74000000
     
    Accessories for Temperature Controllers

    Washdown Autotuning Temperature Controllers

    The faceplate on these controllers is sealed to meet NEMA 4X and IP66 for protection in washdown environments with splashing water, corrosive liquid, and dust. The rear case meets IP20, which prevents objects about the size of a finger from coming into contact with a live circuit.
    Because they have proportional-integral-derivative (PID) software, these controllers are ideal for turning heating equipment on and off in systems with rapid, unpredictable, and complex temperature changes. They help you achieve precise and stable temperature control with fuzzy logic that learns system behavior and automatically compensates for changes. Use the autotuning function to cycle and identify the ideal PID variables for your system to achieve the most precise control. These controllers read temperature with a highly sensitive thermocouple probe (sold separately) in critical process applications. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, and other settings.
    Controllers with Mechanical Relay Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN

    Panel Cutout Size

    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Mechanical relay outputs actuate circuits directly.
    SPDT—Single pole, double throw (SPDT) relays can be set to turn the circuit from off to on (normally open) or from on to off (normally closed).
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    1Heating—1 Mechanical RelayHeating—SPST-NO
    Heating— 3 amp @ 220V ACThermocoupleAutomatic100 to 240IP20, IP66, NEMA 4X
    7981K810000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPST-NO
    Alarm—SPST-NO
    Heating—3 amp @ 250V AC
    Alarming—1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K16000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPDT
    Alarm—SPST-NO
    Heating— 5 amp @ 250V AC
    Alarming— 1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K51000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPDT
    Alarm—SPST-NO
    Heating—3 amp @ 250V AC
    Alarming—1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K61000000
     
    Accessories for Temperature Controllers
    Controllers with Solid State Relay Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN

    Panel Cutout Size

    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They last longer than mechanical and analog signal relays. Use them for more precise and rapid control switching than mechanical relays.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    1Heating—1 15V DC Solid State RelayThermocoupleAutomatic100 to 240IP20, IP66, NEMA 4X
    7981K820000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K18000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K54000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K64000000
     
    Accessories for Temperature Controllers
    Controllers with Analog Signal Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/16 DIN

    Panel Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Analog signal outputs send 4-20 mA current to actuate equipment on a current loop. They are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K170000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K53000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K63000000
     
    Accessories for Temperature Controllers

    DIN-Rail-Mount Autotuning Temperature Controllers

    Image of ProductInUse. Front orientation. Temperature Controllers. DIN-Rail-Mount Autotuning Temperature Controllers.
    Mount these temperature controllers directly onto DIN rail for controlling systems with rapid, unpredictable, or complex temperature changes. They turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    All meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open).
    For Alarming and For Cooling—Those with cooling/alarm outputs can also be used to turn cooling equipment on or off at a specified temperature.
    For Alarming—Alarm outputs can be configured to actuate alarms or other simple devices.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N110000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N12000000
     
    Solid State Relay Output
    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They last longer than mechanical and analog signal relays. Use them for more precise and rapid control switching than mechanical relays.
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N130000000
     
    Analog Signal Output
    Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N140000000
     
    back to top