    About Selecting Thermal Insulation
    industrial info icon

    Compare R-value and temperature range to find the insulation material that best suits your application.

    Fiberglass Pipe Insulation

    When foam can't handle the heat, go with fiberglass insulation. It withstands temperatures hundreds of degrees hotter than rubber or polyethylene foam, so it's often used on hot water supply and steam lines.
    Slit 90° Elbows
    Image of Product. Without Jacket. Front orientation. Pipe Insulation. Fiberglass Pipe Insulation, Slit 90° Elbows.
    Image of Product. Front orientation. Pipe Insulation. Fiberglass Pipe Insulation, Slit 90° Elbows, PVC Jacket.

    Without Jacket

    PVC Jacket

    Ready to fit over right-angle pipe bends. Just pull open the insulation, snap it around your pipe, and seal it closed with the included ties.
    PVC Jacket—A tough shell prevents damage from bumps and scuffs during maintenance, as well as from equipment vibration.
    Insulation Tapes—Wrap around pipe insulation for a tighter seal.
    Pipe Insulation
    Insulation Tapes
    ID
    For Pipe
    Size
    For Copper
    Tube Size
    Temp. Range,
    ° F
    Insulation
    R Value
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Flexibility
    Each
    Each
    Without Jacket
     
    1" Thick Wall
    5/8"3/8
    1/2
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K711000000———0
    7/8"1/2
    3/4
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K71400000———0
    1 1/8"3/4
    1
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K74500000———0
    1 3/8"1
    1 1/4
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K71700000———0
    1 5/8"1 1/4
    1 1/2
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K72100000———0
    1 7/8"1 1/2
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K74800000———0
    2 1/8"2
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K72400000———0
    2 3/8"2
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K75200000———0
    2 5/8"2 1/2
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K72700000———0
    2 7/8"2 1/2
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K75500000———0
    3 1/2"3
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K77600000———0
    4 1/2"4
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K77900000———0
    5 1/2"5
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K78300000———0
    6 5/8"6
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K78600000———0
    8 5/8"8
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K78900000———0
    10 3/4"10
    0 to 1,0004.30.23 BTU/hr @ 75° F5Rigid5556K802000000———0
     
    1 1/2" Thick Wall
    5/8"3/8
    1/2
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K71200000———0
    7/8"1/2
    3/4
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K71500000———0
    1 1/8"3/4
    1
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K74600000———0
    1 3/8"1
    1 1/4
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K71800000———0
    1 5/8"1 1/4
    1 1/2
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K72200000———0
    1 7/8"1 1/2
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K74900000———0
    2 1/8"2
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K72500000———0
    2 3/8"2
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K75300000———0
    2 5/8"2 1/2
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K72800000———0
    2 7/8"2 1/2
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K75600000———0
    3 1/2"3
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K77700000———0
    4 1/2"4
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K78100000———0
    5 1/2"5
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K78400000———0
    6 5/8"6
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K78700000———0
    8 5/8"8
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K799000000———0
    10 3/4"10
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K803000000———0
    12 3/4"12
    0 to 1,0006.50.23 BTU/hr @ 75° F5Rigid5556K806000000———0
     
    2" Thick Wall
    5/8"3/8
    1/2
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K71300000———0
    7/8"1/2
    3/4
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K71600000———0
    1 1/8"3/4
    1
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K74700000———0
    1 3/8"1
    1 1/4
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K71900000———0
    1 5/8"1 1/4
    1 1/2
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K72300000———0
    1 7/8"1 1/2
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K75100000———0
    2 1/8"2
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K72600000———0
    2 3/8"2
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K75400000———0
    2 5/8"2 1/2
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K72900000———0
    2 7/8"2 1/2
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K75700000———0
    3 1/2"3
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K77800000———0
    4 1/2"4
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K78200000———0
    5 1/2"5
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K78500000———0
    6 5/8"6
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K788000000———0
    8 5/8"8
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K801000000———0
    10 3/4"10
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K804000000———0
    12 3/4"12
    0 to 1,0008.70.23 BTU/hr @ 75° F5Rigid5556K807000000———0
     
    PVC Jacket
     
    1" Thick Wall
    7/8"1/2
    3/4
    0 to 1,0004.30.23 BTU/hr @ 75° F6Rigid5556K4410000076145A19000000
    1 1/8"3/4
    1
    0 to 1,0004.30.23 BTU/hr @ 75° F6Rigid5556K4420000076145A1900000
    1 3/8"1
    1 1/4
    0 to 1,0004.30.23 BTU/hr @ 75° F6Rigid5556K4430000076145A1900000
    1 5/8"1 1/4
    1 1/2
    0 to 1,0004.30.23 BTU/hr @ 75° F6Rigid5556K4440000076145A1900000
    1 7/8"1 1/2
    0 to 1,0004.30.23 BTU/hr @ 75° F6Rigid5556K4450000076145A1900000
    2 3/8"2
    0 to 1,0004.30.23 BTU/hr @ 75° F6Rigid5556K4460000076145A1900000
     

    PVC Pipe Insulation Jacketing

    Protect insulation from light impact and moisture with this durable PVC jacketing. When selecting size, use the OD of the insulation you are jacketing. Seal with sealant or tape (sold separately).
    45° Elbows
    Image of Product. Front orientation. Pipe Insulation Jacketing. PVC Pipe Insulation Jacketing, 45° Elbows.
    For Pipe Insulation
    OD
    Flexibility
    Includes
    Temp. Range,
    ° F
    Color
    Flammability Rating
    Each
    1 7/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K15100000
    2 1/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K560000
    2 3/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1520000
    2 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K570000
    2 7/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1530000
    3 1/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K580000
    3 3/8" to 3 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1540000
    3 7/8" to 4 1/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1750000
    4 3/8" to 4 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1760000
    4 7/8" to 5 3/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1770000
    5 1/2" to 5 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1780000
    5 7/8" to 6 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K17900000
    6 7/8" to 7 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K19500000
    7 7/8" to 8 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K19600000
    8 7/8" to 9 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K12200000
    10 1/8" to 10 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K19800000
    11 1/8" to 11 3/4"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1300000
    12 1/8" to 12 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1400000
    Accessories for Pipe Insulation Jacketing
    90° Elbows
    Image of Product. Front orientation. Pipe Insulation Jacketing. PVC Pipe Insulation Jacketing, 90° Elbows.
    For Pipe Insulation
    OD
    Flexibility
    Includes
    Temp. Range,
    ° F
    Color
    Flammability Rating
    Each
    1 7/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K12300000
    2 1/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K180000
    2 3/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1250000
    2 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K190000
    2 7/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1270000
    3 1/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K210000
    3 3/8" to 3 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1290000
    3 7/8" to 4 1/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1330000
    4 3/8" to 4 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1410000
    4 7/8" to 5 3/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K1420000
    5 1/2" to 5 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K14300000
    5 7/8" to 6 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K14500000
    6 7/8" to 7 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K14700000
    7 7/8" to 8 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K14800000
    8 7/8" to 9 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K12400000
    10 1/8" to 10 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K15500000
    11 1/8" to 11 3/4"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K2600000
    12 1/8" to 12 5/8"Flexible1 1/2" Thick Piece of Fiberglass Insulation0 to 140WhiteASTM E84 25/50 for Flame and Smoke
    45315K2800000
    Accessories for Pipe Insulation Jacketing

    Rubber Foam Pipe Insulation

    Easy to cut and shape, this highly flexible insulation fits a variety of pipe layouts. It repels moisture to keep temperatures stable and protect pipes from corroding, extending your system's life.
    Solid 90° Elbows
    Image of Product. Front orientation. Pipe Insulation. Rubber Foam Pipe Insulation, Solid 90° Elbows.
    Slide these elbows over new right-angle pipe bends as you assemble a line. You can also cut them wherever you need to make custom splits.
    Buna-N/PVC Foam—Lighter and more durable than EPDM foam, this foam also withstands exposure to oil. However, it's less flexible than EPDM.
    Coatings—Add a coating of acrylic paint to repel moisture and protect against UV and ozone damage.
    Contact Adhesives—Secure insulation to pipes and seal gaps between sections.
    Pipe Insulation
    Coatings
    Contact
    Adhesives
    ID
    For Pipe
    Size
    For Copper
    Tube Size
    Temp. Range,
    ° F
    Insulation
    R Value
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Flexibility
    Each
    Each
    Each
    Buna-N/PVC Foam
     
    1/2" Thick Wall
    1/2"1/4
    3/8
    -40 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K11000004530K1830000004463K211000000
    3/4"5/8
    -40 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K1200004530K183000004463K21100000
    3 5/8"3
    3 1/2
    -40 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K18000004530K183000004463K21100000
     
    3/4" Thick Wall
    1/2"1/4
    3/8
    -40 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K2200004530K183000004463K21100000
    3/4"5/8
    -40 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K2400004530K183000004463K21100000
    3 5/8"3
    3 1/2
    -40 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K57000004530K183000004463K21100000
     
    1" Thick Wall
    1/2"1/4
    3/8
    -40 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6100004530K183000004463K21100000
    3/4"5/8
    -40 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6300004530K183000004463K21100000
    3 5/8"3
    3 1/2
    -40 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K96000004530K183000004463K21100000
     
    Slit 90° Elbows
    Image of Product. Front orientation. Pipe Insulation. Rubber Foam Pipe Insulation, Slit 90° Elbows.
    Ready to fit over right-angle pipe bends. Just pull open the insulation and snap it around your pipe.
    Buna-N/PVC Foam—Lighter and more durable than EPDM foam, this foam also withstands exposure to oil. However, it's less flexible than EPDM.
    Coatings—Add a coating of acrylic paint to repel moisture and protect against UV and ozone damage.
    Contact Adhesives—Secure insulation to pipes and seal gaps between sections.
    Pipe Insulation
    Coatings
    Contact
    Adhesives
    ID
    For Pipe
    Size
    For Copper
    Tube Size
    Temp. Range,
    ° F
    Insulation
    R Value
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Flexibility
    Each
    Each
    Each
    Buna-N/PVC Foam
     
    3/8" Thick Wall
    5/8"3/8
    1/2
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K31000004530K1830000004463K211000000
    7/8"1/2
    3/4
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K3300004530K183000004463K21100000
    1 1/8"3/4
    1
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K3500004530K183000004463K21100000
    1 3/8"1
    1 1/4
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K3700004530K183000004463K21100000
    1 5/8"1 1/4
    1 1/2
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K3900004530K183000004463K21100000
    1 7/8"1 1/2
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K3200004530K183000004463K21100000
     
    1/2" Thick Wall
    5/8"3/8
    1/2
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K7100004530K183000004463K21100000
    7/8"1/2
    3/4
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K7300004530K183000004463K21100000
    1 1/8"3/4
    1
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K7500004530K183000004463K21100000
    1 3/8"1
    1 1/4
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K7700004530K183000004463K21100000
    1 5/8"1 1/4
    1 1/2
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K7900004530K183000004463K21100000
    1 7/8"1 1/2
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K7200004530K183000004463K21100000
    2 1/8"2
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K7400004530K183000004463K21100000
    2 3/8"2
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K1300004530K183000004463K21100000
    2 5/8"2 1/2
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K1400004530K183000004463K21100000
    2 7/8"2 1/2
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K1500004530K183000004463K21100000
    3 3/8"3
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K1700004530K183000004463K21100000
    4 1/8"3 1/2
    4
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K19000004530K183000004463K21100000
    4 3/8"4
    -295 to 22020.25 BTU/hr @ 75° F4.5Flexible93715K21000004530K183000004463K21100000
     
    3/4" Thick Wall
    5/8"3/8
    1/2
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K2300004530K183000004463K21100000
    7/8"1/2
    3/4
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K2500004530K183000004463K21100000
    1 1/8"3/4
    1
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K2600004530K183000004463K21100000
    1 3/8"1
    1 1/4
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K2700004530K183000004463K21100000
    1 5/8"1 1/4
    1 1/2
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K2800004530K183000004463K21100000
    1 7/8"1 1/2
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K2900004530K183000004463K21100000
    2 1/8"2
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K5100004530K183000004463K21100000
    2 3/8"2
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K52000004530K183000004463K21100000
    2 5/8"2 1/2
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K5300004530K183000004463K21100000
    3 1/8"3
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K55000004530K183000004463K21100000
    3 3/8"3
    -295 to 22030.25 BTU/hr @ 75° F4.5Flexible93715K56000004530K183000004463K21100000
     
    1" Thick Wall
    5/8"3/8
    1/2
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6200004530K183000004463K21100000
    7/8"1/2
    3/4
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6400004530K183000004463K21100000
    1 1/8"3/4
    1
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6500004530K183000004463K21100000
    1 3/8"1
    1 1/4
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6600004530K183000004463K21100000
    1 5/8"1 1/4
    1 1/2
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6700004530K183000004463K21100000
    1 7/8"1 1/2
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6800004530K183000004463K21100000
    2 1/8"2
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K6900004530K183000004463K21100000
    2 3/8"2
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K91000004530K183000004463K21100000
    2 5/8"2 1/2
    -295 to 22040.25 BTU/hr @ 75° F4.5Flexible93715K92000004530K183000004463K21100000
     
    Slit Tees
    Image of Product. Front orientation. Pipe Insulation. Rubber Foam Pipe Insulation, Slit Tees.
    Ready to fit over pipe tees. Just pull open the insulation and snap it around your pipe.
    Buna-N/PVC Foam—Lighter and more durable than EPDM foam, this foam also withstands exposure to oil. However, it's less flexible than EPDM.
    Coatings—Add a coating of acrylic paint to repel moisture and protect against UV and ozone damage.
    Contact Adhesives—Secure insulation to pipes and seal gaps between sections.
    Pipe Insulation
    Coatings
    Contact
    Adhesives
    ID
    For Pipe
    Size
    For Copper
    Tube Size
    Temp. Range,
    ° F
    Insulation
    R Value
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Flexibility
    Each
    Each
    Each
    Buna-N/PVC Foam
     
    3/8" Thick Wall
    7/8"1/2
    3/4
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K43000004530K1830000004463K211000000
    1 1/8"3/4
    1
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K4500004530K183000004463K21100000
    1 3/8"1
    1 1/4
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K4700004530K183000004463K21100000
    1 5/8"1 1/4
    1 1/2
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K4900004530K183000004463K21100000
    1 7/8"1 1/2
    -295 to 2201.50.25 BTU/hr @ 75° F4.5Flexible93715K4200004530K183000004463K21100000
     

    Metal Pipe Insulation Jacketing

    Guard insulation from heavy impact and chemical exposure. This metal jacketing is corrosion resistant and often used outdoors. Install with banding (not included).
    Aluminum Tubes
    Image of Product. Front orientation. Pipe Insulation Jacketing. Metal Pipe Insulation Jacketing, Tube.
    Tubes are coated in a film that creates a moisture barrier.
    3 ft. Long
    For Pipe Insulation
    OD
    Color
    Flexibility
    Specs.
    Met
    Each
    3"SilverFlexibleASTM B2094569K2200000
    3 1/2"SilverFlexibleASTM B2094569K2300000
    4"SilverFlexibleASTM B2094569K2400000
    4 1/2"SilverFlexibleASTM B2094569K2500000
    5"SilverFlexibleASTM B2094569K2600000
    5 1/2"SilverFlexibleASTM B2094569K2700000
    6 1/2"SilverFlexibleASTM B2094569K2800000
     
    Aluminum 90° Elbows
    Image of Product. Front orientation. Pipe Insulation Jacketing. Metal Pipe Insulation Jacketing, 90° Elbow.
    For Pipe Insulation
    OD
    Color
    Flexibility
    Specs.
    Met
    Each
    2 1/2" to 3"SilverFlexibleASTM B2094569K11000000
    3 1/8" to 3 5/8"SilverFlexibleASTM B2094569K1200000
    3 3/4" to 4"SilverFlexibleASTM B2094569K1300000
    4 1/8" to 4 3/8"SilverFlexibleASTM B2094569K1400000
    4 1/2" to 5"SilverFlexibleASTM B2094569K1500000
    5 1/8" to 5 5/8"SilverFlexibleASTM B2094569K1600000
    5 3/4" to 6 5/8"SilverFlexibleASTM B2094569K1700000
    6 3/4" to 7 5/8"SilverFlexibleASTM B2094569K1800000
    7 3/4" to 8 5/8"SilverFlexibleASTM B2094569K1900000
    8 3/4" to 9 5/8"SilverFlexibleASTM B2094569K2100000
     

    Polyethylene Foam Pipe Insulation

    An economical choice, this insulation is ideal for light duty plumbing and HVAC. Like rubber foam insulation, it repels moisture to keep temperatures stable and protect pipes from corroding. However, it's less flexible.
    Slit 90° Elbows
    Image of Product. Front orientation. Pipe Insulation. Polyethylene Foam Pipe Insulation, Slit 90° Elbows.
    Ready to fit over right-angle pipe bends. Just pull open the insulation and snap it around your pipe.
    Coatings—Add a coating of acrylic paint to repel moisture and protect against UV and ozone damage.
    Contact Adhesives—Secure insulation to pipes and seal gaps between sections.
    Pipe Insulation
    Coatings
    Contact
    Adhesives
    ID
    For Pipe
    Size
    For Copper
    Tube Size
    Temp. Range,
    ° F
    Insulation
    R Value
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Flexibility
    Each
    Each
    Each
     
    3/8" Thick Wall
    5/8"3/8
    1/2
    -330 to 2101.50.245 BTU/hr @ 75° F1.5Flexible9619K11000004530K1830000004463K211000000
    7/8"1/2
    3/4
    -330 to 2101.50.245 BTU/hr @ 75° F1.5Flexible9619K1300004530K183000004463K21100000
    1 1/8"3/4
    1
    -330 to 2101.50.245 BTU/hr @ 75° F1.5Flexible9619K1500004530K183000004463K21100000
    1 3/8"1
    1 1/4
    -330 to 2101.50.245 BTU/hr @ 75° F1.5Flexible9619K1700004530K183000004463K21100000
    1 5/8"1 1/4
    1 1/2
    -330 to 2101.50.245 BTU/hr @ 75° F1.5Flexible9619K1900004530K183000004463K21100000
    2 1/8"2
    -330 to 2101.50.245 BTU/hr @ 75° F1.5Flexible9619K1400004530K183000004463K21100000
     
    1/2" Thick Wall
    5/8"3/8
    1/2
    -330 to 21020.245 BTU/hr @ 75° F1.5Flexible9619K3100004530K183000004463K21100000
    7/8"1/2
    3/4
    -330 to 21020.245 BTU/hr @ 75° F1.5Flexible9619K3300004530K183000004463K21100000
    1 1/8"3/4
    1
    -330 to 21020.245 BTU/hr @ 75° F1.5Flexible9619K3500004530K183000004463K21100000
    1 3/8"1
    1 1/4
    -330 to 21020.245 BTU/hr @ 75° F1.5Flexible9619K3700004530K183000004463K21100000
    1 5/8"1 1/4
    1 1/2
    -330 to 21020.245 BTU/hr @ 75° F1.5Flexible9619K3900004530K183000004463K21100000
    1 7/8"1 1/2
    -330 to 21020.245 BTU/hr @ 75° F1.5Flexible9619K3200004530K183000004463K21100000
    2 1/8"2
    -330 to 21020.245 BTU/hr @ 75° F1.5Flexible9619K3400004530K183000004463K21100000
     

    Ultra-Thermally-Insulating Polyisocyanurate Foam Pipe Insulation

    Our best pipe insulation for maintaining temperatures. Use it on long runs where temperatures must stay constant, such as in refrigeration systems or to move liquified natural gas. Polyisocyanurate insulation resists moisture, so it maintains its thermal performance and prevents corrosion underneath.
    Slit 90° Elbows
    Image of Product. Front orientation. Pipe Insulation. Ultra-Thermally-Insulating Polyisocyanurate Foam Pipe Insulation, Slit 90° Elbows.
    Ready to fit over right-angle pipe bends. Just pull open the insulation, snap it around your pipe, and seal it closed with contact adhesives or insulation tape (not included).
    ID
    For Pipe
    Size
    For Copper
    Tube Size
    Temp. Range,
    ° F
    Insulation
    R Value
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Flexibility
    Each
     
    1" Thick Wall
    7/8"1/2
    3/4
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T11000000
    1 1/8"3/4
    1
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T1200000
    1 3/8"1
    1 1/4
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T1300000
    1 5/8"1 1/4
    1 1/2
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T1400000
    1 7/8"1 1/2
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T1500000
    2 3/8"2
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T1600000
    2 7/8"2 1/2
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T1700000
    3 1/2"3
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T1800000
    4"3 1/2
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T1900000
    4 1/2"4
    -295 to 3005.90.17 BTU/hr @ 75° F2Rigid9097T2100000
     
    2" Thick Wall
    7/8"1/2
    3/4
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T31100000
    1 1/8"3/4
    1
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T32100000
    1 3/8"1
    1 1/4
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T33100000
    1 5/8"1 1/4
    1 1/2
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T34100000
    1 7/8"1 1/2
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T35100000
    2 3/8"2
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T36100000
    2 7/8"2 1/2
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T37100000
    3 1/2"3
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T38100000
    4"3 1/2
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T39100000
    4 1/2"4
    -295 to 30011.80.17 BTU/hr @ 75° F2Rigid9097T41100000
     

    Chemical-Resistant Cellular Glass Pipe Insulation

    Absorbs no moisture, so it’s immune to organic solvents, most acids, and corrosive environments. It's often used in chemical-processing systems and underground lines.
    Slit 90° Elbows
    Image of Product. Front orientation. Pipe Insulation. Chemical-Resistant Cellular Glass Pipe Insulation, Slit 90° Elbows.
    Ready to fit over right-angle pipe bends. Just pull open the insulation and snap it around your pipe.
    Jackets—An added defense against moisture for pipes in damp outdoor and underground environments. These metal jackets keep moisture from sneaking past, preventing corrosion and temperature loss.
    Insulation Tapes—Wrap around pipe insulation to seal shut.
    Pipe Insulation
    Jackets
    Insulation Tapes
    ID
    For Pipe
    Size
    For Copper
    Tube Size
    Temp. Range,
    ° F
    Insulation
    R Value
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Flexibility
    Choose a Fitting
    Connection
    Each
    Each
    Each
     
    1" Thick Wall
    1 1/8"3/4
    1
    -450 to 9003.40.29 BTU/hr @ 75° F7.5RigidThreaded, Weld Socket6140K7200000045565K31400000045565K315000000
    1 3/8"1
    1 1/4
    -450 to 9003.40.29 BTU/hr @ 75° F7.5RigidThreaded, Weld Socket6140K730000045565K3140000045565K31500000
    1 5/8"1 1/4
    1 1/2
    -450 to 9003.40.29 BTU/hr @ 75° F7.5RigidThreaded, Weld Socket6140K740000045565K3140000045565K31500000
    1 7/8"1 1/2
    -450 to 9003.40.29 BTU/hr @ 75° F7.5RigidThreaded, Weld Socket6140K750000045565K3140000045565K31500000
    2 3/8"2
    -450 to 9003.40.29 BTU/hr @ 75° F7.5RigidThreaded, Weld Socket6140K760000045565K3140000045565K31500000
     
    1 1/2" Thick Wall
    5 5/8"5
    -450 to 9005.20.29 BTU/hr @ 75° F7.5RigidThreaded6140K5470000045565K3140000045565K31500000
     
    2" Thick Wall
    1 3/8"1
    1 1/4
    -450 to 9006.90.29 BTU/hr @ 75° F7.5RigidThreaded6140K2130000045565K3140000045565K31500000
    2 3/8"2
    -450 to 9006.90.29 BTU/hr @ 75° F7.5RigidThreaded, Weld Socket6140K1160000045565K3140000045565K31500000
     
    back to top