Material Material |
---|
|
|
Body Material Body Material |
---|
|
For Pipe Material For Pipe Material |
---|
|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Drive Style Drive Style |
---|
![]() | |
Connection Style Connection Style |
---|
![]() |
Threaded |
![]() |
Clamp On |
![]() |
Socket Connect |
Environment Environment |
---|
|
|
Environmental Rating Environmental Rating |
---|
Specifications Met Specifications Met |
---|
|
How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
Cleanout Plugs


Close off your drain cleanout pipe with these threaded plugs. Note: If you do not know your pipe size, measure the OD of your existing cleanout plug or the ID of your cleanout fitting and match to the value listed.
For technical drawings and 3-D models, click on a part number.
Black ABS Plastic | ||||
---|---|---|---|---|
Recessed | ||||
For Pipe Size | Thread Type | Cleanout Plug OD/Fitting ID | Each | |
__ | NPT | 4 31/32" | 0000000 | 00000 |
1 1/2 | NPT | 1 7/8" | 0000000 | 0000 |
2 | NPT | 2 3/8" | 0000000 | 0000 |
2 1/2 | NPT | 2 27/32" | 0000000 | 0000 |
3 | NPT | 3 15/32" | 0000000 | 0000 |
3 1/2 | NPT | 3 31/32" | 0000000 | 0000 |
4 | NPT | 4 15/32" | 0000000 | 00000 |
6 | UNC | 6 19/32" | 0000000 | 00000 |
Driver for Recessed Plugs | 000000 | Each | 000000 |
Stoppers for Sink Drains

For Drain ID | Color | Each | |
Plastic | |||
---|---|---|---|
1 3/4" | Black | 0000000 | 00000 |
Sink Drains


Styles F and G are chemical resistant and often used for lab sinks. Style F have a thin top—choose these drains for stainless steel sinks. Style G have a thick top that’s best for epoxy resin sinks.
For technical drawings and 3-D models, click on a part number.


Drains | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Drain | Replacement Stoppers | |||||||||
Style | For Sink Drain Opening Dia. | Top Dia. | Ht. | Pipe Size | Thread Type | Gender | Each | Each | ||
Black Plastic | ||||||||||
F | 1 7/8"-3" | 3 3/8" | 2 1/4" | 2 | NPS | Male | 0000000 | 0000000 | 000000 | 00 |
F | 1 7/8"-3" | 3 3/8" | 3 3/4" | 1 1/2 | NPS | Male | 0000000 | 00000 | 0000000 | 00000 |
G | 1 7/8"-3" | 3 3/8" | 3 3/4" | 1 1/2 | NPS | Male | 0000000 | 00000 | 000000 | 00 |
White Plastic | ||||||||||
F | 1 7/8"-3" | 3 3/8" | 3 3/4" | 1 1/2 | NPS | Male | 0000000 | 00000 | 000000 | 00 |
G | 1 7/8"-3" | 3 3/8" | 3 3/4" | 1 1/2 | NPS | Male | 0000000 | 00000 | 000000 | 00 |
Plastic Sink Drains with Adjustable-Height P-Trap

This drain is chemical resistant and often used in lab sinks. The P-trap prevents vapors from returning up through the drain.
Outlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Sink Drain Opening Dia. | Top Dia. | Max. Vertical Adjustment | Pipe Size | Thread Type | Gender | Color | Trap Color | Specifications Met | Each | |
Drains with Plastic Stopper | ||||||||||
1 7/8"-3" | 3 3/8" | 5 1/2" | 1 1/2 | NPT | Male | Black | White | ASTM F1412 | 0000000 | 0000000 |
Plastic Sink Drains with Collection Trap
Often used in laboratory applications, these drains have a removable collection trap that catches sediment and objects. Traps also block vapors from returning up through the drain.
Drains with slip-joint connection include an adapter tube with an unthreaded male outlet for use as an extension to another slip-joint connection. Trap withstands frost, boiling water, and detergents.
Drain with pipe connection has a semi-clear trap so you can see when it needs to be emptied. Trap withstands harsh chemicals.

Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
Cap., fl. oz. | Dia. | Ht. | For Sink Drain Opening Dia. | Top Dia. | Outlet OD | Color | Trap Color | Each | |
Drains with Adapter Tube and Plastic Stopper | |||||||||
8 | 3 3/8" | 10 5/8" | 1 7/8"-3" | 3 3/8" | 1 1/2" | White | White | 000000 | 0000000 |

Overall | Outlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Dia. | Ht. | For Sink Drain Opening Dia. | Top Dia. | Pipe Size | Thread Type | Gender | Color | Trap Color | Specifications Met | Each | |
Drains with Plastic Stopper | ||||||||||||
1 | 7 1/2" | 11 3/4" | 1 7/8"-3" | 3 3/8" | 1 1/2 | NPT | Male | Black | Semi-Clear | ASTM F1412 | 0000000 | 0000000 |
2 | 7 1/2" | 17" | 1 7/8"-3" | 3 3/8" | 1 1/2 | NPT | Male | Black | Semi-Clear | ASTM F1412 | 0000000 | 000000 |
Floor Drain Plugs

Often used to prevent spills from going down your drain, these plugs resist oil and most chemicals. They are nonabsorbent, washable, and reusable. An eyebolt at the top makes these plugs easy to insert and remove.
Sewer Drain Grate Guards

Placed under a grate, these guards have filter strips to catch oil, sediment, and other pollutants.
For Max. Drain Grate | ||||
---|---|---|---|---|
Lg. | Wd. | Spill Cap., gal. | Each | |
Polypropylene Plastic | ||||
44" | 32" | 1 3/8 | 0000000 | 000000 |
Anti-Clog Shower Stoppers

Prevent clogs from ever forming. Push the top of this stopper 3 to 5 times to plunge and cut trapped material.
For technical drawings and 3-D models, click on a part number.
Material | Dia. | Ht. | Each | |
Plastic | 2" | 2 11/16" | 0000000 | 000000 |
Enclosure Drains


Mount these drains at the bottom of your enclosure to let moisture drip out and keep electronics dry.
Style A drains have a gasket that seals out air, water, and dust during high-pressure washdowns or when submerged. They also meet UL 94 V-0 for flame retardance.
Style B drains are for use in dusty and wet environments.
Thread Size | Thread Pitch, mm | For Hole Diameter | Head Diameter | For Maximum Panel Thickness | Environmental Rating | Environment | Material | Specifications Met | Each | ||
A | M50 | 1.5 | 2" | 2 3/8" | 3/16" | IP66, IP67, IP69K | Damp, Dusty, Washdown, High-Pressure Washdown, Outdoor, Submersible, Wet Location | Plastic | UL 746C f1, UL 94 V-0 | 0000000 | 000000 |
B | M3 | 0.5 | 5/8" | 15/16" | 0.079" | IP55 | Damp, Dusty, Washdown | Plastic | __ | 00000000 | 0000 |
Drain Vents

Mount to the outside of your enclosure to prevent moisture from being trapped inside. Rated NEMA 4X for protection from washdowns and corrosion.
Ht. | Wd. | Dp. | Environmental Rating | Material | Mounting Fasteners Included | Color | Each | |
2 3/4" | 2" | 11/16" | NEMA 4X | Fiberglass | Yes | Gray | 000000 | 000000 |
Hazardous Location Drain Vents

Safe for use around hazardous gasses and dust, these vents maintain steady pressure and prevent moisture buildup from temperature changes inside enclosures. They allow air to flow through the enclosures while protecting the contents from washdowns, dirt, and weather. Install these vents at the lowest point on an enclosure, so moisture can drip out.
Increased-safety drains keep sparks, high temperatures, or current creepage inside an enclosure, so they won’t ignite flammable gasses and dust.
Glass-filled nylon drains are lightweight yet durable. They’re good for most areas.
For technical drawings and 3-D models, click on a part number.
Thread Size | Thread Pitch, mm | Height | Environmental Rating | Nut Material | O-Ring Material | Color | Maximum Temperature, °F | Specifications Met | Each | |
Increased-Safety Drains | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Glass-Filled Nylon Plastic | ||||||||||
M20 | 1.5 | 1 1/4" | NEMA 4X; IP66; NEC Class I Division 2 Groups A, B, C, D | Brass | Buna-N Rubber | Black | 185° | ATEX II 2DG IECEx Ex tb IIIC Db IECEx Exe II Gb | 0000000 | 000000 |
Aboveground Standard-Wall PVC Pipe Fittings for Drain, Waste, and Vent

- For Use With: Water
- Max. Temperature: 140° F
- Specifications Met: ASTM D1784, ASTM D2665
- Pipe Nipples and Pipe: Use Schedule 40 PVC Plastic
- Flanges: Use Schedule 40 PVC Plastic
These Schedule 40 fittings are the industry standard for gravity-flow drain, waste, and vent (DWV) applications. Fittings are PVC, which has good corrosion resistance. They meet ASTM D1784 and ASTM D2665 specifications and testing requirements for material quality.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
Sealants cannot be sold to Colorado, Connecticut, District of Columbia, Delaware, Illinois, Indiana, Massachusetts, Maryland, Maine, Michigan, New Hampshire, New Jersey, Northern Virginia, New York, Ohio, Pennsylvania, Rhode Island, or Utah due to local VOC (Volatile Organic Compounds) regulations.
For technical drawings and 3-D models, click on a part number.

To prevent leaks in threaded connections, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic threaded connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
.
Underground PVC Pipe Fittings for Drain, Waste, and Vent

- For Use With: Water
- Max. Temperature: 140° F
- Specifications Met: ASTM D2729, ASTM D3034
With thinner walls than Schedule 40 fittings, these are lighter in weight and have more space on the inside for high-flow applications, such as underground gravity-flow sewer and storm drainage lines. They are also known as SDR 35 fittings. Fittings are PVC, which has good corrosion resistance. Fittings meet ASTM D2729 and ASTM D3034 specifications and testing requirements for material quality.
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
Sealants cannot be sold to Colorado, Connecticut, District of Columbia, Delaware, Illinois, Indiana, Massachusetts, Maryland, Maine, Michigan, New Hampshire, New Jersey, Northern Virginia, New York, Ohio, Pennsylvania, Rhode Island, or Utah due to local VOC (Volatile Organic Compounds) regulations.
For technical drawings and 3-D models, click on a part number.

To prevent leaks in threaded connections, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic threaded connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
.
Underground Snap-Lock Polyethylene Pipe Fittings for Drain, Waste, and Vent
- For Use With: Water
- Specifications Met: ASTM F667
The snap-together design allows you to quickly connect these fittings to pipe with no cement required. Fittings are typically used in gravity-flow drainage applications. Made of high-density polyethylene (HDPE), they stand up to freeze/thaw cycles and resist corrosion and stress cracking. Fittings meet ASTM F667 specifications and testing requirements for material quality as well as soil conservation service (SCS) standards for use in underground drain lines.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas. Do not expose fittings to direct sunlight.
For technical drawings and 3-D models, click on a part number.
Drain, Waste, and Vent ABS Pipe Fittings for Chemicals

- For Use With: Sodium Hydroxide
- Max. Temperature: 180° F
- Specifications Met: ASTM D2661, ASTM D3311, ASTM D3965, ASTM F1498
- Pipe Nipples and Pipe: Use Schedule 40 ABS Plastic
- Flanges: Use Schedule 40 ABS Plastic
These Schedule 40 fittings are an economical option for gravity-flow chemical waste systems. They are ABS plastic, which has excellent strength and impact resistance and good chemical resistance. Fittings meet ASTM D2661, ASTM D3311, ASTM D3965, and ASTM F1498 specifications and testing requirements for material quality and product dimensions.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
Sealants cannot be sold to Colorado, Connecticut, District of Columbia, Delaware, Illinois, Indiana, Massachusetts, Maryland, Maine, Michigan, New Hampshire, New Jersey, Northern Virginia, New York, Ohio, Pennsylvania, Rhode Island, or Utah due to local VOC (Volatile Organic Compounds) regulations.
For technical drawings and 3-D models, click on a part number.

To prevent leaks in threaded connections, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic threaded connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
Low-Pressure Clamp-On Connectors for Drain, Waste, and Vent
Tighten the bands on these connectors to form a strong seal on pipe or fittings.
For technical drawings and 3-D models, click on a part number.

- For Use With: Air, Water
- Temperature Range: -40° to 120° F
- Specifications Met: ASTM D5926
- For Pipe Material: Stainless Steel, Iron, Steel, Aluminum, PVC Plastic, CPVC Plastic
For Pipe OD | For Pipe Size | Max. Pressure | Material | Clamp Material | Flexibility | Each | |
Pipe | |||||||
---|---|---|---|---|---|---|---|
1.9" | 1 1/2 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 0000000 | 00000 |
2 3/8" | 2 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 0000000 | 0000 |
3 1/2" | 3 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 0000000 | 0000 |
4 1/2" | 4 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 0000000 | 0000 |
5.6" | 5 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 00000000 | 00000 |
6.6" | 6 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 00000000 | 00000 |
8 1/2" | 8 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 00000000 | 00000 |
10.47" | 10 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 00000000 | 00000 |
12.7" | 12 | 4 psi @ 72° F | PVC Plastic | 300 Series Stainless Steel | Flexible | 00000000 | 000000 |
Magnetic Spill-Control Drain Covers

Stop oil, chemicals, and other spills from going down the drain with these magnetic covers. Powerful magnets hold them in place on metal grates and drains for a tight seal that stays put. The durable vinyl construction won’t tear or degrade from exposure to spills or repeated washing.
Dia. | Thick. | Material | Color | Each | |
12" | 1/4" | Vinyl Plastic | Yellow | 0000000 | 000000 |
Spill-Control Drain Covers

Block grates and manholes to stop liquids from going in, or seal inactive drains to keep odors from leaking out. Wash and reuse these polyurethane covers for multiple jobs—this durable material doesn’t tear easily and won’t degrade in water, oil, or chemicals.
36” wd. × 60” lg. covers are designed to fit over trench-style drains.
Wd. | Lg. | Dia. | Thick. | Material | Color | Each | |
__ | __ | 12" | 1/4" | Polyurethane Rubber | Red | 0000000 | 000000 |
18" | 18" | __ | 1/4" | Polyurethane Rubber | Red | 0000000 | 000000 |
24" | 24" | __ | 1/4" | Polyurethane Rubber | Red | 0000000 | 000000 |
36" | 36" | __ | 1/4" | Polyurethane Rubber | Red | 0000000 | 000000 |
36" | 60" | __ | 1/4" | Polyurethane Rubber | Red | 0000000 | 000000 |
48" | 48" | __ | 1/4" | Polyurethane Rubber | Red | 0000000 | 000000 |
Curb-Style Storm Drain Filters

Prevent rainwater from carrying trash, debris, and sediment into sewers. These filters are often used on construction sites. They mount inside curb openings, keeping them out of the way of vehicles.
Push the foam anchors on 36" and 48" filters into a curb opening to hold them securely in place, even during heavy rainstorms. Connect them side by side or cut them to length to fit any drain width.