Choosing an Electrical Switch
More
Air-Actuated Foot Switches
Switch
Switch with Guard
Press these switches with your foot for convenient, hands-free operation. They use air pressure to turn circuits on or off, keeping live electrical circuits away from work areas. Use the three-prong outlet to plug a device directly into the switch.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Dia. | Lg. | Wd. | Ht. | Guard Material | Includes | Each | |
With Three-Prong Outlet | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 15 A @ 120 V AC | 3 3/4" | __ | __ | 1 1/2" | __ | 10 ft. Tubing | 0000000 | 000000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 15 A @ 120 V AC | 3 3/4" | __ | __ | 1 1/2" | __ | 10 ft. Tubing | 0000000 | 00000 |
With Three-Prong Outlet and Guard | |||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 15 A @ 120 V AC | __ | 6" | 6 1/2" | 4 11/16" | Plastic | 10 ft. Tubing | 0000000 | 00000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 15 A @ 120 V AC | __ | 6" | 6 1/2" | 4 11/16" | Plastic | 10 ft. Tubing | 0000000 | 00000 |
Build-Your-Own Air-Actuated Foot Switches
Combine a foot-pedal actuator with a switching mechanism to build a complete switch that allows for convenient, hands-free operation. These switches use air pressure to turn circuits on or off, keeping live electrical circuits away from work areas.
Switching Mechanisms
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Quick-Disconnect Tab Wd. | Specifications Met | Each | |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | 3 | SPDT | 21 A @ 250 V AC | 0.25" | CE Marked, CSA Certified, UL Listed, UL 508 | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 21 A @ 250 V AC | 0.25" | CE Marked, CSA Certified, UL Listed, UL 508 | 0000000 | 00000 |
2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Springs Back (Momentary) | 6 | DPDT | 21 A @ 250 V AC | 0.25" | UL Listed, UL 508 | 0000000 | 00000 |
2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPDT | 21 A @ 250 V AC | 0.25" | CE Marked, CSA Certified, UL Listed, UL 508 | 0000000 | 00000 |