About Calculating the Airflow Required for Air Cleaning
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Portable Air Cleaners
Small enough to carry from job to job. Cleaners remove odors when paired with an optional odor-removal filter and an optional 1" prefilter.
Add duct (sold separately) to exhaust filtered air outside of the space that you are cleaning.
For Duct | Overall | Housing | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Inlet Dia. | Outlet Dia. | Ht. | Wd. | Dp. | Material | Color | Includes | For Removing | Each | |
700 | 73 dBA @ 5 ft. | 1/2 | 120V AC | 3A | 14" | 14" | 23" | 26" | 17" | Plastic | Blue | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles, Odors and Fumes | 00000000 | 000000000 |
Per Ft. | ||
Blo-N-Vent Duct Hose | 0000000 | 000000 |
Portable Air Cleaners with Hose
Carry these cleaners to job sites to remove odors and fumes from the air. Use the hose to direct cleaning.
Overall | Hose | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Includes | For Removing | Each | |
110 | 82 dBA @ 5 ft. | 1/4 | 120V AC | 7A | 2 1/4" | 17" | 23 1/2" | 12" | Steel | 12 | Rubber | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Odors and Fumes | 0000000 | 000000000 |
225 | 82 dBA @ 5 ft. | 1/2 | 120V AC | 14A | 2 1/4" | 17" | 23 1/2" | 12" | Steel | 12 | Rubber | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Odors and Fumes | 0000000 | 00000000 |
Combination Mobile/Bench-Top Air Cleaners
Roll this air cleaner to the contaminant source or place it on a bench top. Attach the included plastic hood to use as an air cleaning booth.
Includes a prefilter; all other filters sold separately.
Standard filter captures 95% of particles down to 3 microns.
HEPA filter captures 99.97% of particles down to 0.3 microns.
Odor-removal filter has carbon to remove odors. It includes a pleated filter that captures 60% of particles down to 3 microns.
Add an odor-removal after-filter to standard and HEPA filters for light duty odor control.
Overall | Hose | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Includes | For Removing | Each | |
350 | 58 dBA @ 15 ft. | 1/4 | 120V AC | 2.8A | 2 1/2" | 19 1/2" | 12 1/2" | 12 1/2" | Powder-Coated Steel | 4 | Plastic | Disposable Prefilter, Plastic Hood | Dust and Particles, Odors and Fumes | 0000000 | 000000000 |
Replacement Carbon for Odor-Removal Filters and After-Filters | 0000000 | Each | 0000000 |
Odor-Removal After-Filters | 0000000 | Each | 000000 |
Odor-Removal Filters | 0000000 | Each | 000000 |
Replacement Prefilters(Pkg. of 4) | 0000000 | Pkg. | 000000 |
Replacement Pleated Filters for Odor-Removal Filters and After-Filters | 0000000 | Each | 00000 |
HEPA Filters | 0000000 | Each | 000000 |
Standard Filters | 0000000 | Each | 000000 |
Mobile Air Cleaners
These air cleaners roll to where you need them.
For Inlet Duct | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Wd. | Ht. | For Outlet Duct Dia. | Ht. | Wd. | Dp. | No. of Speeds | Includes | For Removing | Each | |
2,000 | 64 dB @ 15 ft. | 3/4 | 120V AC | 15A | 24" | 25" | 12" | 31" | 26" | 42" | Three | Disposable After-Filter, Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles | 0000000 | 000000000 |
Office Air Cleaners
Purify the air in spaces with light cleaning needs.
Bench-top cleaners are often used for small rooms or individual workstations. They require one filter (included).
Freestanding cleaners can be used in meeting spaces and large offices. They require three HEPA filters (included).
Overall | Housing | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Mounting Location | Ht. | Wd. | Dp. | Material | Color | Control Type | No. of Speeds | Includes | For Removing | Each | |
62 | 50 dBA @ 3 ft. | 120V AC | 0.28A | Bench Top | 6 5/8" | 12 11/16" | 9 3/4" | Plastic | White | Knob | Three | Disposable HEPA/Odor-Removal Filter (Captures 99% of particles down to 2 microns) | Dust and Particles, Odors and Fumes | 0000000 | 000000 |
330 | 60 dBA @ 3 ft. | 120V AC | 1.1A | Freestanding | 22 3/8" | 20" | 10 13/16" | Plastic | White | Touchpad | Four | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Odor-Removal Filter | Dust and Particles, Odors and Fumes | 00000000 | 000000 |
3D Printer Portable Air Cleaners
Draw particles and filament fumes away from open-frame 3D printers without cooling off printed parts. Unlike standard air cleaners, which create airflow strong enough to cool the print area and warp your parts, these low-airflow cleaners won’t disrupt your print. A three-part filtering process keeps you from breathing harmful emissions: a prefilter traps large particles, then a combination HEPA and activated carbon filter captures both fine particles and fumes. These CE marked cleaners meet health, safety, and environmental protection standards for products.
Attach the included hose and funnel to the cleaner to pull fumes directly from your printer. These compact, lightweight cleaners fit into most work areas, and are quiet enough for office use. The powder-coated steel housing holds up over a long service life.
Overall | Hose | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Current, A | Voltage | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Cord Lg., ft. | Includes | Each | |
26 | 44 dBA @ 3 ft. | 0.2 | 120V AC | 2" | 13 1/4" | 11 1/4" | 11" | Powder-Coated Steel | 6 | Plastic | 6 | Combination HEPA/Chemical Filter (Captures 99.99% of particles down to 0.03 microns), Disposable Prefilter | 0000000 | 0000000 |
Smoke Removal Blowers
Quickly ventilate smoke, gas, and other fumes by forcing fresh air into your space instead of exhausting air out. These fans improve air quality and manage temperature and moisture levels.
Gas-powered blowers generate higher airflow than battery-powered blowers. They cannot be sold to Canada due to import regulations.
Blowers with an aluminum housing are easy to roll and lift. Blowers with a plastic housing have good corrosion resistance.
Overall | Capacity, oz. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Run Time, min. | Engine Displacement, cu. in. | Fuel | Oil | Temp. Range, °F | Housing Material | Cannot Be Sold To | Each | |
Mobile | |||||||||||||||
14,700 | 95 dBA @ 15 ft. | 4 3/4 | 24 1/4" | 22 3/4" | 21" | 85 | 75 | 9.9 | 105 | 19.5 | 5° to 110° | Powder-Coated Steel | Canada | 0000000 | 000000000 |
Overall | Battery Charger | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Run Time, min. | Batteries Included | Included | Voltage | Temp. Range, °F | Housing Material | Environmental Rating | Each | |
Mobile—Totally Enclosed Motor Enclosure | |||||||||||||||||
10,800 | 73 dBA @ 15 ft. | 3,200 | Variable | 3/4 | 24 3/8" | 22 7/8" | 11 3/4" | 51 | 45 | Yes | Yes | 120V AC | 0° to 110° | Powder-Coated Aluminum | IP65 | 0000000 | 000000000 |
Portable—Totally Enclosed Motor Enclosure | |||||||||||||||||
10,900 | 73 dBA @ 15 ft. | 2,350 | Variable | 3/4 | 21" | 22" | 11" | 51 | 50 | Yes | Yes | 120V AC | 0° to 110° | Plastic | IP66 | 0000000 | 00000000 |
10,900 | 73 dBA @ 15 ft. | 2,350 | Variable | 3/4 | 21" | 22" | 11" | 51 | 50 | Yes | Yes | 240V AC | 0° to 110° | Plastic | IP66 | 0000000 | 00000000 |
Voltage | Cap., amp-hrs. | Each | |
Lithium Ion (Li-Ion) | |||
---|---|---|---|
20V DC/60V DC | 9 | 000000000 | 0000000 |
Voltage | Cap., amp-hrs. | Each | |
Lithium Ion (Li-Ion) | |||
---|---|---|---|
48V DC | 12.5 | 0000000 | 000000000 |