    74 Products

    Low-Profile Power-Conditioning Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies. Low-Profile Power-Conditioning Backup Power Supplies.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.

    NEMA

    5-15

    Socket

    Smaller in height than standard backup power supplies, these fit in tight spaces. They transfer power to a built-in battery during brownouts and blackouts with only a momentary loss of power during transfer. They also protect against line noise and power surges. All have a USB connection and cord so you can save data and safely shut down an unattended computer during outage. Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Output NEMA Sockets
    Output USB
    Sockets
    Power
    Current,
    amp
    Voltage,
    V AC
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    No. of Outlets with
    Battery Backup
    Electrical
    Connection
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Each
    350 VA/210 W2.9120825-15
    Straight Blade35-15
    63USB-B14.1"4.3"7.3"7530K620000000
    550 VA/300 W4.612051.25-15
    Straight Blade35-15
    105USB-A, USB-B24.1"4.3"7.3"7530K63000000
    750 VA/450 W6.3120112.55-15
    Straight Blade35-15
    126USB-A13.1"12.2"6.9"7530K44000000

    Enclosed Isolating Transformers

    These transformers have isolated primary and secondary coils to protect your sensitive equipment from input voltage spikes.
    Single Phase—Plug Input and Socket Output Connection
    Image of Product. Front orientation. Transformers. Enclosed Isolating Transformers, Single Phase—Plug Input and Socket Output Connection.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15. Enclosed Isolating Transformers.
    Image of Specification. NEMA 6-15 Plug. Front orientation. NEMA 6-15. Enclosed Isolating Transformers.

    NEMA

    5-15

    Plug

    NEMA

    6-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. NEMA 5-15. Enclosed Isolating Transformers.

    NEMA

    5-15

    Socket

    Constant Voltage—When wired as constant-voltage transformers, they filter out voltage spikes and electrical noise.
    Voltage,
    V AC
    Input
    Output
    Input
    Output
    Power Output,
    VA
    Plug Connection
    Connection
    NEMA Type
    Socket
    Connection
    Connection
    NEMA Type
    Ht.
    Wd.
    Dp.
    Features
    Each
    Constant Voltage
    1151151503-Blade Straight5-15
    3-Slot Straight5-15
    3.9"3.1"4.2"Isolated Coils70245K710000000
    1151152503-Blade Straight5-15
    3-Slot Straight5-15
    4.7"3.8"4.4"Isolated Coils70245K72000000
    1151151,0003-Blade Straight5-15
    3-Slot Straight5-15
    5.3"4 1/2"8.1"Isolated Coils70245K74000000
     
    Step-Down Voltage
    2301151003-Blade Straight6-15
    3-Slot Straight5-15
    3 1/2"2.8"3.6"Isolated Coils70245K81000000
    2301152503-Blade Straight6-15
    3-Slot Straight5-15
    4.7"3.8"4.4"Isolated Coils70245K83000000
    2301155003-Blade Straight6-15
    3-Slot Straight5-15
    4.7"3.8"6"Isolated Coils70245K84000000
     

    Power-Conditioning Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies. Power-Conditioning Backup Power Supplies, 12 amp Current Output.

    12 amp Current Output

    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.

    NEMA

    5-15

    Socket

    Protect sensitive equipment—these conditioners raise or lower current to keep it at a stable level during dips and surges. There is no battery transfer time during a power dip. During brownouts and blackouts, they transfer power to a built-in battery with only a momentary loss of power during transfer. Power supplies also protect against line noise and power surges. They have a USB connection and cord so you can save data and safely shut down an unattended computer during outage.
    Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Output NEMA Sockets
    Output USB
    Sockets
    Power
    Current,
    amp
    Voltage,
    V AC
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    No. of Outlets with
    Battery Backup
    Electrical
    Connection
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Each
    1,440 VA/900 W121201235-15
    Straight Blade35-15
    105USB-A211"3.9"16.1"70475K340000000

    International Transformers

    Image of Product. Output for Europe and United States. Front orientation. Europe. International Transformers.
    Image of Product. Output for Germany, Spain, and United States. Front orientation. Germany. International Transformers.

    Output for Europe and United States

    Output for Germany, Spain, and

    United States

    Image of Specification. 2-Blade Straight Plug. Front orientation. 2 Input Blades. International Transformers, Straight Blade.
    Image of Specification. CEE 7/3 Socket. Front orientation. CEE 7/3. International Transformers.

    2-Blade

    Straight

    Plug

    CEE 7/3

    Socket

    Image of Specification. Universal Socket. Front orientation. Universal. International Transformers.
    Image of Specification. NEMA 5-15 Socket. Front orientation. NEMA 5-15. International Transformers.

    Universal

    Socket

    NEMA

    5-15

    Socket

    These transformers continuously operate at 80% of the rated power output. They convert voltage to run American appliances in Europe or European appliances in the United States. These transformers are CE Marked, which means they meet European Union safety standards.
    Input
    Output
    Power Output,
    VA
    Plug Connection
    Plug Style
    Socket
    Connection
    Socket Style
    No. of
    Outputs
    Freq., Hz
    Ht.
    Wd.
    Dp.
    Plug Adapter Type (Style)
    Each
    Single Phase—Step-Up/Step-Down Voltage, 110V AC/220V AC Input and Output Voltage
    1002-Blade StraightCEE 7/7 (Europe)2-Slot Straight
    3-Slot Straight
    CEE 7/3 (Type F) (Germany, Spain)
    NEMA 5-15 (United States)
    1
    1
    50/603"3"5"NEMA 1-15 (United States), NEMA 5-15 (United States)70285K111000000
    2002-Blade StraightCEE 7/7 (Europe)2-Slot Straight
    3-Slot Straight
    CEE 7/3 (Type F) (Germany, Spain)
    NEMA 5-15 (United States)
    1
    1
    50/603 1/4"3 1/2"5 3/4"NEMA 1-15 (United States), NEMA 5-15 (United States)70285K11200000
    3002-Blade StraightCEE 7/7 (Europe)2-Slot Straight
    3-Slot Straight
    CEE 7/3 (Type F) (Germany, Spain)
    NEMA 5-15 (United States)
    1
    2
    50/603 1/2"3 3/4"6"NEMA 1-15 (United States), NEMA 5-15 (United States)70285K81000000
    5002-Blade StraightCEE 7/7 (Europe)2-Slot Straight
    3-Slot Straight
    CEE 7/3 (Type F) (Germany, Spain)
    NEMA 5-15 (United States)
    1
    2
    50/603 1/2"4"6 1/2"NEMA 1-15 (United States), NEMA 5-15 (United States)70285K82000000
    8002-Blade StraightCEE 7/7 (Europe)2-Slot Straight
    3-Slot Straight
    CEE 7/3 (Type F) (Germany, Spain)
    NEMA 5-15 (United States)
    1
    2
    50/604 1/2"5 1/4"7 1/2"NEMA 1-15 (United States), NEMA 5-15 (United States)70285K113000000
    1,0002-Blade StraightCEE 7/7 (Europe)2-Slot Straight
    3-Slot Straight
    CEE 7/3 (Type F) (Germany, Spain)
    NEMA 5-15 (United States)
    1
    2
    50/604 3/4"6 1/4"9"NEMA 1-15 (United States), NEMA 5-15 (United States)70285K83000000
    1,5002-Blade StraightCEE 7/7 (Europe)2-Slot Straight
    3-Slot Straight
    CEE 7/3 (Type F) (Germany, Spain)
    NEMA 5-15 (United States)
    2
    2
    50/605 3/4"6 3/4"9 3/4"NEMA 1-15 (United States), NEMA 5-15 (United States)70285K114000000
    2,0002-Blade StraightCEE 7/7 (Europe)2-Slot Straight
    3-Slot Straight
    CEE 7/3 (Type F) (Germany, Spain)
    NEMA 5-15 (United States)
    2
    2
    50/606"7 1/2"9 3/4"NEMA 1-15 (United States), NEMA 5-15 (United States)70285K84000000
    3,0002-Blade StraightCEE 7/7 (Europe)3-Slot Straight
    3-Slot Straight
    Universal (Europe)
    NEMA 5-15 (United States)
    1
    1
    50/605 3/4"7"9 3/4"NEMA 1-15 (United States), NEMA 5-15 (United States), BS 1363 (Type G) (United Kingdom)70285K115000000
     

    Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.

    NEMA

    5-15

    Socket

    Transfer power to a built-in battery during brownouts and blackouts with only a momentary loss of power during transfer. With a USB connection and cord, you can save data and safely shut down an unattended computer during an outage with these supplies. They also protect against line noise and power surges. Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC. Power supplies cannot be sold to the regions listed due to local energy efficiency requirements.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Output USB
    Sockets
    Output
    Ethernet Sockets
    Power
    Current,
    amp
    Voltage,
    V AC
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    Electrical
    Connection
    No. of
    Outlets
    Connection
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Cannot Be Sold To
    Each
    700 VA/350 W5.81201035-15
    Straight Blade35-15
    6USB-A1RJ4519.8"4.8"13.6"Colorado, Vermont, Washington7530K380000000

    Uninterruptible Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies. Uninterruptible Backup Power Supplies.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.
    Image of Specification. NEMA 5-20 Plug. Front orientation. NEMA 5-20.
    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.

    NEMA

    5-15

    Plug

    NEMA

    5-20

    Plug

    NEMA

    5-15

    Socket

    Image of Specification. NEMA 5-20 Socket. Front orientation. NEMA 5-20.
    Image of Specification. NEMA L5-20 Socket. Front orientation. NEMA L5-20.

    NEMA

    5-20

    Socket

    NEMA

    L5-20

    Socket

    Protect sensitive and critical electronic equipment—these uninterruptible power supplies (UPS) do not suffer a loss of power when switching from your power source to the UPS during an outage. They also protect against frequency variation and waveform distortion. All have USB and DB9 connections with cords so you can save data and safely shut down an unattended computer during outages. Choose a power output that is equal to or greater than the power your equipment requires.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Input Voltage
    Range, V AC
    Power
    Current,
    amp
    Voltage,
    V AC
    Voltage
    Accuracy
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Specs.
    Met
    Each
    100 to 1201,000 VA/900 W9.1120±1%18.26.35-15
    Straight Blade35-15
    83.5"17.4"17.8"UL 177870485K31000000000
    100 to 1201,500 VA/1,350 W12.5120±1%16.55.85-15
    Straight Blade35-15
    83.5"17.4"17.8"UL 177870485K3200000000
    100 to 1202,200 VA/1,800 W18.3120±1%20.27.75-20
    Straight Blade35-20
    L5-20
    6
    1
    3.5"17.4"23.9"UL 177870485K2400000000

    Bench-Top Variable-Voltage Transformers

    Mount these portable transformers to any flat surface. Turn the dial to adjust the voltage you need within a given range. Also known as variacs, they are often used in laboratories to vary power, heat, speed, or force.
    Single Phase—Plug Input and Socket Output Connection
    Image of Product. Front orientation. Transformers. Bench-Top Variable-Voltage Transformers.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15. Bench-Top Variable-Voltage Transformers.
    Image of Specification. NEMA 5-20 Plug. Front orientation. NEMA 5-20. Bench-Top Variable-Voltage Transformers.
    Image of Specification. NEMA 6-15 Plug. Front orientation. NEMA 6-15. Bench-Top Variable-Voltage Transformers.

    NEMA

    5-15

    Plug

    NEMA

    5-20

    Plug

    NEMA

    6-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. NEMA 5-15. Bench-Top Variable-Voltage Transformers.
    Image of Specification. NEMA 5-20 Socket. Front orientation. NEMA 5-20. Bench-Top Variable-Voltage Transformers.
    Image of Specification. NEMA 6-15 Socket. Front orientation. NEMA 6-15. Bench-Top Variable-Voltage Transformers.

    NEMA

    5-15

    Socket

    NEMA

    5-20

    Socket

    NEMA

    6-15

    Socket

    Constant Voltage—When wired for constant voltage, transformers filter out voltage spikes and electrical noise.
    Voltage,
    V AC
    Input
    Output
    Input
    Output
    Power Output,
    VA
    Plug Connection
    Connection
    NEMA Type
    Socket
    Connection
    Connection
    NEMA Type
    Max. Current,
    amp
    Ht.
    Wd.
    Dp.
    Features
    Certification
    Each
    Step-Up/Step-Down/Constant Voltage
    1200 to 1323303-Blade Straight5-15
    3-Slot Straight5-15
    2.55.3"6.1"4.1"Fuse, Power-Indicating LightCSA Certified
    6994K110000000
    1200 to 1407003-Blade Straight5-15
    3-Slot Straight5-15
    55.3"6.1"4.1"Fuse, Power-Indicating Light6994K14000000
    1200 to 1401,4003-Blade Straight5-15
    3-Slot Straight5-15
    107"4.6"5 1/2"Fuse, Power-Indicating LightCSA Certified
    6994K17000000
    1200 to 1402,1003-Blade Straight5-15
    3-Slot Straight5-15
    159.4"6.2"6"Fuse, Power-Indicating LightCSA Certified
    6994K2100000000
    1200 to 1403,0803-Blade Straight5-20
    3-Slot Straight5-20
    2210.9"8"6.3"Fuse, Power-Indicating Light6994K2300000000
    2400 to 2809803-Blade Straight6-15
    3-Slot Straight6-15
    3.57"4.6"5 1/2"Fuse, Power-Indicating Light6994K18000000
    2400 to 2802,6603-Blade Straight6-15
    3-Slot Straight6-15
    9.59.4"6.2"6"Fuse, Power-Indicating Light6994K2200000000
     
    Step-Down/Constant Voltage
    1200 to 1201,4403-Blade Straight5-15
    3-Slot Straight5-15
    127"4.6"5 1/2"Fuse, Power-Indicating LightCSA Certified
    6994K24000000
    2400 to 2401,2003-Blade Straight6-15
    3-Slot Straight6-15
    57"4.6"5 1/2"Fuse, Power-Indicating LightCSA Certified
    6994K19000000
     

    Low-Current Transformers

    Power low-voltage devices such as alarms and sensors.
    Single Phase—Plug Input and Screw-Terminal Output Connection
    Image of Product. Front orientation. Transformers. Low-Current Transformers, Single Phase—Plug Input and Screw-Terminal Output Connection, NEMA 1-15.
    Image of Product. NEMA 5-15. Front orientation. Transformers. Low-Current Transformers, Single Phase—Plug Input and Screw-Terminal Output Connection, NEMA 5-15, Auto Reset, Power-Indicating Light.

    NEMA 1-15

    NEMA 5-15

    Image of Specification. NEMA 1-15 Plug. Front orientation. NEMA 1-15. Low-Current Transformers.

    NEMA

    1-15

    Plug

    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15. Low-Current Transformers.

    NEMA

    5-15

    Plug

    Voltage,
    V AC
    Input
    Input
    Output
    Power Output,
    VA
    Plug Connection
    Connection
    NEMA Type
    Ht.
    Wd.
    Dp.
    Features
    Certification
    Each
    Step-Down Voltage
    12012202-Blade Straight1-15
    3.2"2.6"1.9"UL Listed
    5600K31000000
    12016202-Blade Straight1-15
    3.1"2.1"1.9"UL Listed
    5600K3200000
    12016403-Blade Straight5-15
    3.6"2.6"2.1"Auto Reset, Power-Indicating LightUL Listed
    5600K1900000
    12024203-Blade Straight5-15
    3.2"2.6"1.9"Auto Reset, Power-Indicating LightUL Listed
    5600K3300000
    12024403-Blade Straight5-15
    3.6"2.6"2.1"Auto Reset, Power-Indicating LightUL Listed
    5600K1800000
     

    Ultra-Low-Noise Bench-Mount Power Supplies

    Change AC voltage to DC voltage to power extremely sensitive audio, measuring, and testing devices while keeping electronic interference—often called output or ripple noise—from passing on to the device. The lower the output noise value, the less interference the power supplies will create. Although they create less noise than other power supplies, these power supplies are larger, heavier, and give off more heat.
    Designed with linear voltage regulation, these power supplies produce the same voltage regardless of changes in the input voltage or the amount of current being drawn. They are also known as linear power supplies.
    View the output on a digital or analog display.
    If you exceed the maximum load or current, all of these power supplies will shut down to protect both the power supply and the connected device.
    With 1 Output Power Connection—Digital Display
    Image of Product. Front orientation. Power Supplies. Ultra-Low-Noise Bench-Mount Power Supplies, With 1 Output Power Connection—Digital Display.
    Digital displays are often easier to read than analog displays, so you can quickly see if you need to make adjustments.
    Over Temperature—Those with overvoltage or over temperature protection will shut down if you exceed the maximum voltage or temperature.
    Output
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Output Connection
    Location
    Output Features
    Ht.
    Wd.
    Dp.
    Electrical Protection Type
    Each
    Single Phase—120/240V AC Input Voltage
    Standard Banana Socket0V DC to 18V DC0 amp to 5 amp0 W to 90 W4 mV DCFrontConstant Current, Constant Voltage5.5"6.5"10.4"Over Temperature, Overcurrent, Overload7686K250000000
    Standard Banana Socket0V DC to 30V DC0 amp to 3 amp0 W to 90 W4 mV DCFrontConstant Current, Constant Voltage5.5"6.5"10.4"Over Temperature, Overcurrent, Overload7686K24000000
    Standard Banana Socket0V DC to 30V DC0 amp to 6 amp0 W to 180 W5 mV DCFrontConstant Current, Constant Voltage5.5"6.5"10.4"Over Temperature, Overcurrent, Overload7686K27000000
    Standard Banana Socket1V DC to 18V DC0 amp to 3 amp0 W to 54 W2 mV DCFrontConstant Current, Constant Voltage4.3"9.4"6"Overcurrent, Overload5773N12000000
    Standard Banana Socket1V DC to 30V DC0 amp to 1 amp0 W to 30 W2 mV DCFrontConstant Current, Constant Voltage4.3"9.4"6"Overcurrent, Overload5773N11000000
     
    With 1 Output Power Connection—Analog Display
    Image of Product. Front orientation. Power Supplies. Ultra-Low-Noise Bench-Mount Power Supplies, With 1 Output Power Connection—Analog Display.
    Analog displays are better than digital displays for monitoring fast output changes, such as dips and spikes.
    Output Voltage Selector Switch—Power supplies with an output voltage selector switch let you toggle between two voltage and current output ranges.
    Output
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Output Connection
    Location
    Output Features
    Ht.
    Wd.
    Dp.
    Electrical Protection
    Type
    Each
    Single Phase—120/240V AC Input Voltage
    Standard Banana Socket0V DC to 30V DC0 amp to 2 amp0 W to 60 W5 mV DCFrontConstant Current, Constant Voltage4.3"8"8.3"Overcurrent, Overload7686K210000000
    Standard Banana Socket0V DC to 18V DC, 0V DC to 36V DC0 amp to 7 amp, 0 amp to 3.5 amp0 W to 126 W4 mV DCFrontConstant Current, Constant Voltage, Output Voltage Selector Switch5.5"12.1"10.5"Overcurrent, Overload7686K26000000
     
    With 2 Output Power Connections—Analog Display
    Image of Product. Front orientation. Power Supplies. Ultra-Low-Noise Bench-Mount Power Supplies, With 2 Output Power Connections—Analog Display.
    Analog displays are better than digital displays for monitoring fast output changes, such as dips and spikes.
    Over Temperature—Those with overvoltage or over temperature protection will shut down if you exceed the maximum voltage or temperature.
    Output
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Output Connection
    Location
    Output Features
    Ht.
    Wd.
    Dp.
    Electrical Protection Type
    Each
    Single Phase—120/240V AC Input Voltage
    Standard Banana Socket0V DC to 30V DC
    0V DC to 30V DC
    0 amp to 3 amp
    0 amp to 3 amp
    0 W to 90 W
    0 W to 90 W
    5 mV DC
    5 mV DC
    FrontConstant Current, Constant Voltage5.5"12.1"10.5"Over Temperature, Overcurrent, Overload7686K290000000
     
    With 3 Output Power Connections—Digital Display
    Image of Product. Front orientation. Power Supplies. Ultra-Low-Noise Bench-Mount Power Supplies, With 3 Output Power Connections—Digital Display.
    Digital displays are often easier to read than analog displays, so you can quickly see if you need to make adjustments.
    Overvoltage—Those with overvoltage or over temperature protection will shut down if you exceed the maximum voltage or temperature.
    UL Listed and C-UL Listed—UL and C-UL listed power supplies meet U.S. and Canadian safety standards.
    Output
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Output Connection
    Location
    Output Features
    Ht.
    Wd.
    Dp.
    Electrical Protection Type
    Certification
    Includes
    Each
    Single Phase—120/240V AC Input Voltage
    Standard Banana Socket0V DC to 30V DC
    0V DC to 30V DC
    4V DC to 6.5V DC
    0 amp to 2 amp
    0 amp to 2 amp
    5 amp
    0 W to 60 W
    0 W to 60 W
    20 W to 32.5 W
    3 mV DC
    3 mV DC
    6 mV DC
    FrontConstant Current, Constant Voltage5.7"10.5"15"Overcurrent, Overload, OvervoltageUL Listed
    C-UL Listed
    Two Pairs of Test Leads (Banana Jack to Alligator Clip)5775N120000000
    Standard Banana Socket0V DC to 32V DC
    0V DC to 32V DC
    5V DC
    0 amp to 3 amp
    0 amp to 3 amp
    3 amp
    0 W to 96 W
    0 W to 96 W
    15 W
    1 mV DC
    1 mV DC
    1 mV DC
    FrontConstant Current, Constant Voltage6.7"9"12.2"OverloadTwo Pairs of Test Leads (Banana Jack to Alligator Clip)5775N21000000
    Standard Banana Socket0V DC to 60V DC
    0V DC to 60V DC
    2V DC to 6.5V DC
    0 amp to 2 amp
    0 amp to 2 amp
    5 amp
    0 W to 120 W
    0 W to 120 W
    10 W to 32.5 W
    3 mV DC
    3 mV DC
    6 mV DC
    FrontConstant Current, Constant Voltage5.7"10.5"15"Overcurrent, Overload, OvervoltageTwo Pairs of Test Leads (Banana Jack to Alligator Clip)5775N13000000
     
    With 4 Output Power Connections—Digital Display
    Image of Product. Front orientation. Power Supplies. Ultra-Low-Noise Bench-Mount Power Supplies, With 4 Output Power Connections—Digital Display.
    Digital displays are often easier to read than analog displays, so you can quickly see if you need to make adjustments.
    Output
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Output Connection
    Location
    Output Features
    Ht.
    Wd.
    Dp.
    Electrical Protection
    Type
    Includes
    Each
    Single Phase—120/240V AC Input Voltage
    Standard Banana Socket0V DC to 30V DC
    0V DC to 30V DC
    3V DC to 6.5V DC
    8V DC to 15V DC
    0 amp to 5 amp
    0 amp to 5 amp
    1 amp
    3 amp
    0 W to 150 W
    0 W to 150 W
    9 W to 19.5 W
    8 W to 15 W
    3 mV DC
    3 mV DC
    6 mV DC
    6 mV DC
    FrontConstant Current, Constant Voltage6.3"10.2"14.6"Overcurrent, OverloadFour Pairs of Test Leads (Banana Jack to Alligator Clip)5773N130000000
     

    Programmable Bench-Mount Power Supplies

    Image of Product. Front orientation. Power Supplies. Programmable Bench-Mount Power Supplies.
    Use your computer to remotely control these power supplies that convert AC voltage to DC voltage for powering electronics from simple prototypes to advanced testing equipment. All of these power supplies include a USB cable and Windows-compatible software to control, monitor, and record the voltage, current, and power outputs of your device. You can also create programs with up to 20 steps that change voltage and current outputs at set times. A selector switch lets you quickly choose up to three defined settings for voltage and current outputs. The power supplies have an auxiliary output connection, but it will take on the same settings as the primary outputs. View the outputs on their digital display.
    These power supplies use switching regulation, which means they produce the stated voltage despite fluctuations in your input power and the power being drawn by your system, and they won’t become too hot. If you exceed the maximum voltage, current, load, or temperature, the power supplies will shut down to protect both the power supply and the connected device.
    Remote Voltage Sensing—Power supplies with remote voltage sensing check for any drops in the voltage as they send power to a device. If the voltage dips, they can compensate with extra power, so connected devices always receive the correct voltage.
    Maximum Output Noise Peak-to-Peak—Maximum output noise is also known as ripple noise. When power supplies convert AC voltage to DC voltage, some noise from the AC voltage will carry into the output. While this noise won't affect most applications, it can interfere with other signals in extremely sensitive audio, measuring, and testing equipment. The lower the output noise, the less interference it creates.
    Output
    Front
    Auxiliary Output
    Display
    Type
    No. of Power
    Connections
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Ht.
    Wd.
    Dp.
    Electrical Protection Type
    Output Connection
    Location
    Output Features
    Voltage,
    V DC
    Current,
    amp
    Each
    Single Phase—120V AC Input Voltage
    Digital1Standard Banana Socket1V DC to 16V DC0 amp to 60 amp0 W to 960 W50 mV DC3.5"7.9"10.8"Over Temperature, Overcurrent, Overload, OvervoltageBackConstant Current, Constant Voltage, Remote Voltage Sensing1 to 160 to 55774N140000000
    Digital1Standard Banana Socket1V DC to 32V DC0 amp to 30 amp0 W to 960 W50 mV DC3.5"7.9"10.8"Over Temperature, Overcurrent, Overload, OvervoltageBackConstant Current, Constant Voltage1 to 320 to 55774N15000000
    Digital1Standard Banana Socket1V DC to 60V DC0 amp to 15 amp0 W to 900 W100 mV DC3.5"7.9"10.8"Over Temperature, Overcurrent, Overload, OvervoltageBackConstant Current, Constant Voltage1 to 600 to 55774N16000000
     
    Single Phase—120, 240V AC Input Voltage
    Digital1Standard Banana Socket1V DC to 18V DC0 amp to 20 amp0 W to 360 W50 mV DC3.5"7.9"8.2"Over Temperature, Overcurrent, Overload, OvervoltageBackConstant Current, Constant Voltage1 to 180 to 55774N13000000
    Digital1Standard Banana Socket1V DC to 36V DC0 amp to 10 amp0 W to 360 W50 mV DC3.5"7.9"8.2"Over Temperature, Overcurrent, Overload, OvervoltageBackConstant Current, Constant Voltage1 to 360 to 55774N12000000
    Digital1Standard Banana Socket1V DC to 60V DC0 amp to 5 amp0 W to 300 W50 mV DC3.5"7.9"8.2"Over Temperature, Overcurrent, Overload, OvervoltageBackConstant Current, Constant Voltage1 to 600 to 55774N11000000
     

    Bench-Mount Power Supplies

    Convert AC voltage into the DC voltages needed to test, design, and prototype a wide variety of electrical circuits and equipment. These power supplies let you adjust the output to the exact voltage needed to power your equipment. You can also set limits on the maximum current to protect your equipment from damage. Keep an eye on the voltage and current drawn by your connected components with the digital display.
    Since these use switching regulation, they produce the stated voltage despite fluctuations in your input power and the power being drawn by your system, and won’t become too hot.
    When these power supplies convert AC voltage to DC voltage, some noise from the AC voltage will carry into the output. While this won't affect most applications, this noise can interfere with other signals in extremely sensitive applications. The lower the output noise, the less interference it creates.
    These power supplies are CE Marked, which means they meet European Union safety standards. If your power supply exceeds the maximum current, voltage, or load, they’ll shut down to protect both the power supply and the connected equipment. Some also protect against excessive temperatures.
    Connect the banana plugs on your equipment to the socket output connections.
    1 Output Power Connection—Banana Jack Socket
    Image of Product. Front orientation. Power Supplies. Bench-Mount Power Supplies, 1 Output Power Connection—Banana Jack Socket.
    Output Voltage Selector Switch—Power supplies with output voltage selector switch let you choose either an adjustable output, which you control with a dial, or an output fixed at 13.8V DC.
    Output
    Front
    Auxiliary Output
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Output Connection
    Location
    Output Features
    Voltage,
    V DC
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Electrical Protection Type
    Each
    Single Phase—120V AC Input Voltage
    Standard Banana Socket1V DC to 30V DC1 amp to 20 amp1 W to 600 W50 mV DCBackConstant Current, Constant Voltage1 to 301 to 53.5"7.9"8.5"Over Temperature, Overcurrent, Overload, Overvoltage5772N160000000
    Standard Banana Socket13.8V DC, 3V DC to 15V DC40 amp552 W, 120 W to 600 W30 mV DCFrontConstant Current, Constant Voltage, Output Voltage Selector Switch4.4"11.9"8.6"Over Temperature, Overcurrent, Overload, Overvoltage5772N12000000
     
    Single Phase—120/240V AC Input Voltage
    Standard Banana Socket1V DC to 15V DC60 amp60 W to 900 W40 mV DCBackConstant Current, Constant Voltage, Remote Signaling1 to 151 to 34.3"8.7"14.2"Over Temperature, Overcurrent, Overload, Overvoltage5772N13000000
    Standard Banana Socket1V DC to 30V DC30 amp30 W to 900 W40 mV DCBackConstant Current, Constant Voltage, Remote Signaling1 to 301 to 54.3"8.7"14.2"Over Temperature, Overcurrent, Overload, Overvoltage5772N14000000
     
    2 Output Power Connections—Banana Jack Socket and USB-A Socket
    Image of Product. Front orientation. Power Supplies. Bench-Mount Power Supplies, 2 Output Power Connections.
    USB-A—Power supplies with USB-A output connections can also charge phones and other devices with USB-A ports. You can use more than one output at the same time, but you can’t adjust them independently—all outputs are set to the voltage you select.
    Output
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Output Connection
    Location
    Output Features
    Ht.
    Wd.
    Dp.
    Electrical Protection Type
    Each
    Single Phase—120V AC Input Voltage
    Standard Banana Socket
    USB-A Socket
    1V DC to 36V DC
    5V DC
    0 amp to 3 amp
    0.4 amp
    0 W to 108 W
    2 W
    50 mV DC
    8 mV DC
    FrontConstant Current, Constant Voltage6"2.9"9.9"Over Temperature, Overcurrent, Overload, Overvoltage5772N110000000
     
    3 Output Power Connections—Banana Jack Socket and Lever-Clamp Terminals
    Image of Product. Front orientation. Power Supplies. Bench-Mount Power Supplies, 3 Output Power Connections.
    Output
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Output Connection
    Location
    Output Features
    Ht.
    Wd.
    Dp.
    Electrical Protection Type
    Each
    Single Phase—120/240V AC Input Voltage
    Standard Banana Socket
    Lever-Clamp Terminal
    Lever-Clamp Terminal
    0V DC to 30V DC
    12V DC
    5V DC
    0 amp to 5 amp
    0.5 amp
    0.5 amp
    0 W to 150 W
    6 W
    2.5 W
    15 mV DC
    15 mV DC
    15 mV DC
    FrontConstant Current, Constant Voltage5"8.5"11.5"Overcurrent, Overload, Overvoltage5772N150000000
     

    Desktop Computer Power Supplies

    Image of Product. Front orientation. Power Supplies. Desktop Computer Power Supplies.
    Image of Specification. Front orientation. ZoomedIn view. 4+4 Pin ATX. Desktop Computer Power Supplies.
    Image of Specification. Front orientation. ZoomedIn view. 20+4 Pin ATX. Desktop Computer Power Supplies.
    Image of Specification. Floppy-Disk Drive Molex Mini-Fit 4 Pin. Front orientation. ZoomedIn view. Floppy-Disk Drive. Desktop Computer Power Supplies, Molex Mini-Fit, 4.

    4+4 Pin ATX

    20+4 Pin ATX

    Floppy-Disk

    Drive Molex

    Mini-Fit 4 Pin

    Image of Specification. PCI-E 6+2 Pin Molex Mini-Fit. Front orientation. ZoomedIn view. PCI-E. Desktop Computer Power Supplies.
    Image of Specification. Peripheral AMP. Front orientation. ZoomedIn view. Peripheral. Desktop Computer Power Supplies.
    Image of Specification. Front orientation. ZoomedIn view. Standard SATA. Desktop Computer Power Supplies.

    PCI-E 6+2 Pin

    Molex Mini-Fit

    Peripheral AMP

    Standard SATA

    Convert AC voltage to DC voltage to power components inside desktop computers. These power supplies meet ATX industry standards, so they fit into most desktop computers. The higher the energy efficiency of a power supply, the lower the operating costs will be. These power supplies generate enough power for PCs with dedicated graphics cards and computers used for intensive tasks such as video editing and CAD design.
    Output
    Voltage
    Current
    Power,
    W
    Standby Current
    @ Voltage
    Plug Type (No. of)
    Energy Efficiency
    Rating
    Efficiency @ Voltage
    Ht.
    Wd.
    Dp.
    Cable Lg.,
    ft.
    Each
    100V AC to 240V AC Input Voltage
    3.3V DC
    5V DC
    12V DC
    22 amp
    17 amp
    42 amp
    6002.5 amp @ 5V DC4+4 Pin ATX (1)
    20+4 Pin ATX (1)
    Floppy-Disk Drive Molex Mini-Fit 4 Pin (3)
    PCI-E 6+2 Pin Molex Mini-Fit (2)
    Peripheral AMP (1)
    Standard ATA Molex Mini-Fit 5 (6)
    80 PLUS Bronze82% @ 115V AC
    82% @ 230V AC
    3.4"5.9"5.5"23737N12000000
     

    Rack-Mount Power Supplies

    Image of Product. With Digital Display. Front orientation. Power Supplies. Rack-Mount Power Supplies, Single Phase, Digital Display.

    With Digital Display

    Image of Product. With Analog Display. Front orientation. Power Supplies. Rack-Mount Power Supplies, Single Phase, Analog Display.

    With Analog Display

    Mount these power supplies into standard 19”-wide electronics racks, which can hold multiple electronic devices and keep your benchtop clear. These power supplies change AC voltage to DC voltage to power highly sensitive audio, measuring, and testing devices while keeping electronic interference—known as output or ripple noise—from passing on to the device. The lower the output noise value, the less interference the power supplies will create.
    Designed with linear voltage regulation, these power supplies produce the same voltage regardless of changes in the input voltage or the amount of current being drawn. They are also known as linear power supplies. As they send power to a device, they use remote voltage sensing to check for any drops in the voltage. If the voltage dips, they can compensate with extra power, so connected devices always receive the correct voltage.
    If you exceed the maximum current or load, these power supplies will shut down to protect both the power supply and the connected device.
    View the output on a digital or analog display.
    Digital Display—Digital displays are often easier to read than analog displays, so you can quickly see if you need to make adjustments.
    Analog Display—Analog displays are better than digital displays for monitoring fast output changes, such as dips and spikes.
    Output
    Mounting
    Display
    Type
    No. of Power
    Connections
    Connection
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Ht.
    Wd.
    Dp.
    Electrical Protection
    Type
    Output Connection
    Location
    Output Features
    Fasteners
    Included
    Number
    of Holes
    Each
    Single Phase—120, 240V AC Input Voltage
    Digital1Standard Banana Socket0V DC to 20V DC0 amp to 25 amp0 W to 500 W8 mV DC5.8"19"12.8"Overcurrent, OverloadFrontConstant Current, Constant Voltage, Remote Voltage SensingNo47686K410000000
    Analog1Standard Banana Socket0V DC to 30V DC0 amp to 12 amp0 W to 360 W8 mV DC5.8"19"13.5"Overcurrent, OverloadFrontConstant Current, Constant Voltage, Remote Voltage SensingNo47686K28000000
     

    AC to DC Electromagnet Transformers

    Image of Product. Front orientation. Power Supplies. AC to DC Electromagnet Transformers.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15. AC to DC Electromagnet Transformers.

    NEMA

    5-15

    Plug

    Flip the switch to reverse the magnetic current and release your electromagnet's hold. Choose a power output wattage equal to or greater than the watts of your electromagnet. These transformers are rated NEMA 12 for protection from oil/coolant dripping.
    Output
    Mounting
    Input Voltage,
    V AC
    Voltage,
    V DC
    Power,
    W
    Input No. of Blades
    (NEMA Type)
    Ht.
    Wd.
    Dp.
    Number
    of Holes
    Hole
    Diameter
    Fasteners
    Included
    Housing
    Material
    Max. Temp.,
    ° F
    Each
    Single Phase—Plug Input and Wire Leads Output Connection
     
    Step-Down Voltage
    12012483-Blade (NEMA 5-15)3 1/2"6"4"49/32"NoSteel14057245K750000000
    12024483-Blade (NEMA 5-15)3 1/2"6"4"49/32"NoSteel14057245K85000000
    1201108003-Blade (NEMA 5-15)3 1/2"6"4"49/32"NoSteel14057245K96000000
     

    Fixed-Voltage Bench-Mount Power Supplies

    Image of Product. Front orientation. Power Supplies. Fixed-Voltage Bench-Mount Power Supplies.
    Image of Specification. Stud Terminal on Back. Back orientation. Contains Border. Power Supplies. Fixed-Voltage Bench-Mount Power Supplies.

    Stud

    Terminal on

    Back

    No need to adjust the voltage on these power supplies—they’re specifically designed to convert 120V AC to 13.8V DC. This voltage is common in radio transmitters, battery chargers, and automotive electrical systems, so these power supplies are often used to develop and test electronics that will be used in those applications. Since they are not adjustable, there’s no risk of supplying the wrong voltage and damaging your equipment. Power supplies have a stud terminal output connection to work with wire leads. Wrap the wire around the stud and secure with the included nuts, or attach alligator clips to the studs.
    These power supplies have linear voltage regulation, which means they produce the same voltage regardless of changes in the input voltage or the amount of current being drawn. They are also known as linear power supplies. They have extremely low noise output, meaning that they keep electronic interference (also known as output noise or ripple noise) from being passed on to your device. However, these power supplies are larger, use more energy, and give off more heat than switching power supplies with a similar output.
    If you exceed the maximum load or current, they’ll shut down to protect both the power supply and the connected equipment.
    Overvoltage—Power supplies with overvoltage protection will also shut down if you exceed the maximum voltage.
    Output
    No. of Power
    Connections
    Voltage
    Current
    Power
    Max. Noise
    Peak-to-Peak
    Ht.
    Wd.
    Dp.
    Electrical Protection Type
    Output Connection
    Location
    Output Features
    Each
    Single Phase—120V AC Input Voltage
     
    Stud-Terminal Output Connection
    113.8V DC25 amp331.2 W16 mV DC6.8"6.3"10.3"Overcurrent, Overload, OvervoltageBackConstant Voltage5770N180000000
    113.8V DC40 amp532.3 W30 mV DC6.8"10.5"11.5"Overcurrent, Overload, OvervoltageBackConstant Voltage5770N2000000
    113.8V DC60 amp780.5 W28 mV DC6.8"10.5"11.5"Overcurrent, Overload, OvervoltageBackConstant Voltage5770N22000000
     

    Sealed Power Supplies

    Image of Product. 3-Pole M22 Plug Input and 4-Pole M22 Socket Output. Front orientation. 4-Pole Electrical Socket. Sealed Power Supplies.
    Image of Product. 3-Pole M22 Plug Input and 5-Pole M22 Socket Output. Front orientation. 5-Pole Electrical Socket. Sealed Power Supplies.

    3-Pole M22 Plug Input and

    4-Pole M22 Socket Output

    3-Pole M22 Plug Input and

    5-Pole M22 Socket Output

    Image of Specification. 3-Pole M22 Plug. Front orientation. 3 Poles. Sealed Power Supplies.
    Image of Specification. 4-Pole M22 Socket. Front orientation. 4-Pole Electrical Socket. Sealed Power Supplies.

    3-Pole

    M22

    Plug

    4-Pole

    M22

    Socket

    Image of Specification. 5-Pole M22 Socket. Front orientation. 5-Pole Electrical Socket. Sealed Power Supplies.

    5-Pole

    M22

    Socket

    Completely sealed and protected from dust and water, these power supplies don't need a separate electrical panel or enclosure. Instead, mount them directly to machine tools, process control equipment, conveyors, and other equipment found in harsh industrial areas. They convert AC voltage to deliver DC power right at the point of need, reducing the need for complex wiring.
    Rated IP67, all of these power supplies are safe for use in dusty, humid, and wet locations, as well as in applications where the power supply may be briefly submerged in water.
    Although sealed in a housing, these power supplies have excellent heat dissipation, so they run reliably even as temperatures rise. They use switching regulation, which means they produce the stated voltage despite fluctuations in your input power and the power being drawn by your system, and they won’t create much heat. Some of these power supplies are also SEMI F47 compliant, which means they meet standards for maintaining output voltage when input voltage dips. This is commonly known as voltage sag immunity.
    If you exceed the maximum voltage or load, these power supplies shut down to protect both the power supply and the connected equipment. They also meet the voltage requirements for use in a SELV (separated extra low voltage) circuit. With various domestic and international certifications, such as UL listing and CE marking, you can be sure they meet stringent safety standards.
    IP66 Enclosure Rating—IP66-rated power supplies can also withstand frequent washdowns.
    Cannot Be Sold to California and Cannot Be Sold to Vermont—Power supplies that cannot be sold to California and Vermont do not meet energy efficiency requirements.
    Output Peak Current—Power supplies with an output peak current briefly boost power above their maximum operating current for starting motors, actuating solenoid valves, and other applications that require a higher starting current than their operating current.
    Maximum Output Noise Peak-to-Peak—Maximum output noise is also known as ripple noise. The lower the value, the less interference the power supply creates. For most applications, a value over 100mVpp isn’t a problem. However, when using to power extremely sensitive electronics, such as audio equipment and high-precision measuring and testing equipment, you’ll want an output noise around 5mVpp or less.
    Power Factor @ Voltage—Power factor shows how effectively a power supply draws AC power from the main electrical supply. The higher the power factor—up to a maximum score of 1—the lower your operating cost.
    Efficiency @ Voltage—Efficiency describes how good a power supply is at converting the AC power it draws from your main electrical supply into DC power. High-efficiency power supplies cost less money to operate and produce less heat, meaning cooler temperatures in your electrical cabinet.
    Output
    Voltage,
    V DC
    Current,
    amp
    Peak Current,
    amp
    Peak Current
    Duration, sec.
    Power,
    W
    Max. Noise Peak-to-Peak,
    mV DC
    No. of Output
    Connections per Circuit
    Power Factor
    @ Voltage
    Efficiency @ Voltage
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Cannot Be Sold To
    Each
    Single Phase—90-265V AC Input Voltage
     
    3-Pole M22 Plug Input and 5-Pole M22 Socket Output
    244649630010.98 @ 230V AC91.7% @ 115V AC
    92.4% @ 230V AC
    2.1"4.4"5.6"IP67
    California, Vermont3580N150000000
    2481249630010.95 @ 230V AC93% @ 115V AC
    94.2% @ 230V AC
    2.1"4.4"6.9"IP67
    California, Vermont3580N16000000
     
    Single Phase—100-240V AC Input Voltage
     
    3-Pole M22 Plug Input and 4-Pole M22 Socket Output
    243.81005010.9 @ 230V AC84% @ 115V AC
    84% @ 230V AC
    1.9"7.2"4.9"IP66, IP67
    California, Vermont3580N13000000
    247.61005040.9 @ 230V AC85% @ 115V AC
    85% @ 130V AC
    3.4"7.2"4.9"IP66, IP67
    California, Vermont3580N1400000000
     