    Power Consumption Data Loggers

    Track power consumption over time. These loggers tap into a circuit and connect with PC software to visualize energy use and generate reports. They’re often used by energy auditors and facility managers to monitor equipment runtimes, optimize HVAC performance, and troubleshoot voltage spikes.
    Set the sampling interval to determine how often the logger takes measurements. A faster sampling interval will take more readings at the expense of battery life.
    Measures AC Voltage and Current
    Image of Product. Front orientation. Power Consumption Data Loggers. Measures AC Voltage and Current.
    A compact, economical choice for monitoring AC energy consumption. Includes test leads and a clamp-on probe for tapping into wiring without interrupting circuits. Requires one 9V battery as well as software for device setup and data exports, each sold separately.
    Batteries
    Data Log
    Cap.
    Electrical
    Phase
    AC Voltage,
    V AC
    AC Voltage
    Accuracy, V AC
    Current,
    amp
    Current
    Accuracy
    Sampling
    Interval
    Includes
    For Operating System
    Software
    Included
    Included
    Size
    No.
    Req.
    Each
    10,750Single0 to 500-1 to 10 to 3005%1 sec. to 18 hr.Carrying Case, Clamp-On Probe with 1.1" Jaw Opening, Test Leads with Alligator ClipsWindows 10 or EarlierNoNo9V100000000000000
    Measures AC and DC Voltage
    Image of Product. Front orientation. Power Consumption Data Loggers. Measures AC and DC Voltage.
    Measure, log, and track either AC or DC voltage with industry-leading accuracy. Our AC/DC logger can take as many as eight readings per second with a margin of error of just ±0.5%. Software is included for setup and analysis, along with test leads, batteries, and a USB cable to connect with your PC.
    True RMS AC Calculation—True RMS loggers take more accurate AC measurements than regular loggers because they can adapt to irregular waveform readings. They’re ideal for computers, adjustable-speed drives, and other devices that distort the shape of the AC sine wave by drawing current in short pulses.
    Batteries
    Data Log
    Cap.
    AC
    Calculation
    Electrical
    Phase
    Electrical Safety
    Rating
    AC Voltage,
    V AC
    AC Voltage
    Accuracy
    DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Sampling
    Interval
    Includes
    For Operating System
    Software
    Included
    Included
    Size
    No.
    Req.
    Each
    240,000True RMSSingleCAT IV, 300V0 to 600-0.5% to 0.5%0 to 6000.5%125 ms to 24 hr.Test Leads with Alligator Clips, USB CordWindows 10 or EarlierYesYesAA200000000000000

    Power Consumption Meters

    Image of Product. Front orientation. Power Consumption Meters.
    Image of Specification. Front orientation. ZoomedIn view. Digital Display.

    Digital Display

    Measure the amount of power your devices draw and calculate energy costs with these consumption meters. Plug them directly into an outlet, and plug your tool or appliance into the front of the meter. To track your power costs, enter the local price per kilowatt-hour (kWh) into the meter, and they’ll display the total amount you’re spending. They also help you monitor the quality of electricity coming from your outlet.
    These meters meet U.S. and international safety standards. Rated CAT II, 150V, they can be safely used with most single-phase AC appliances and tools.
    Plug Type
    Max. Power,
    W
    Max. AC Voltage,
    V AC
    AC Voltage
    Accuracy
    Max. AC Current,
    amp
    Current
    Accuracy
    Max. Freq.,
    Hz
    Max. Power Consumption,
    kWh
    Max. Electrical
    Cost
    Ht.
    Wd.
    Dp.
    Display
    Type
    Certification
    No. of
    Blades
    Electrical
    Connection
    Features
    Each
    1,800150-1% to 1%151%659,999$9,9995.1"2.6"1 1/2"DigitalUL Listed, CSA Certified, CE Marked, ETL Listed3Straight BladeBackup Battery0000000000000

    Data-Logging Multimeters

    Image of Product. Front orientation. Multimeters. Data-Logging Multimeters.
    Identify intermittent issues such as voltage spikes and temporary power flow problems—these meters record measurements from electrical tests over time. Review data in real time or save it for future analysis.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Data Log
    Cap.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Display
    Count
    Includes
    Each
    True RMS AC Calculation
    50,000CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.025%101010,000Alligator Clips, Test Leads00000000000000
     

    Fluke Data-Logging Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Data-Logging Multimeters.
    Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Software—To download and analyze data on a computer, software is required (not included). Connect your multimeter to a computer with the included USB cord.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Data Log
    Cap.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Hardware Features
    Display
    Count
    Includes
    Each
    Each
    True RMS AC Calculation
    28710,000CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.025%1010Overload Protection50,000Alligator Clips, Test Leads0000000000000000000000000000
    28915,000CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance, Temperature1,0001,0000.025%1010Overload Protection50,000Alligator Clips, Test Leads0000000000000000000000000000
     

    Fluke Oscilloscope/Multimeters

    Image of Product. Front orientation. Oscilloscope/Multimeters.
    Perform electrical tests, record data, and see a graph of electrical waveforms with this combination multimeter and oscilloscope. Fluke oscilloscope/multimeters are known for quality and durability.
    To download and analyze data on a computer, software is required (not included).
    When used as an oscilloscope, the oscilloscope/multimeter is most accurate when the frequency is at least five times the maximum signal frequency you intend to measure.
    True RMS AC Calculation—The multimeter function is true RMS, so it accurately takes AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. This 5,000-count oscilloscope/multimeter shows numbers up to 4,999.
    Mfr. Model
    No.
    No. of Digital
    Channels
    Freq.,
    MHz
    Electrical Safety
    Rating
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Display
    Count
    Data Log
    Cap.
    Includes
    Certification
    Measures
    Batteries
    Included
    Each
    True RMS AC Calculation
    123B20 to 20CAT IV, 600V6006000.5%5,000512Alligator Clips, Battery Charger, BNC Adapter, Probe Tips, Test LeadsCSA Certified
    AC Voltage, Capacitance, Continuity, DC Voltage, TemperatureYes0000000000000000
     

    Fluke Multimeter Cases

    Image of Product. Front orientation. Multimeter Cases. Fabric Case.
    Image of Product. Front orientation. Multimeter Cases. Tool Bag.

    Fabric Case

    Tool Bag

    Mfr. Model
    No.
    Case Type
    For Fluke Model No.
    Each
    C116Fabric Case233, 287, 2890000000000000
    C550Tool Bag27 II, 28 II, 77IV, 83V, 87V, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 324, 355, 373, 374, 376, 381, 787, 789, 1577, 1587, 3000 FC, T5-600, T5-10000000000000000

    Fluke Test Lead Sensors

    Image of Product. Front orientation. Test Lead Sensors. Fluke Test Lead Sensors, Model Number 80BK-A.

    Model Number 80BK-A

    Take temperature readings with a Fluke multimeter.
    Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
    Mfr. Model
    No.
    For Fluke Model No.
    Temp. Range,
    ° F
    Test End
    Component
    Connection End
    Cord
    Lg.
    Test End Insulation
    Material
    Each
    80BK-A28 II, 87V, 116, 179, 233, 287, 289-40 to 500Needle TipSheathed Standard Banana Jack39"PTFE
    0000000000000

    Fluke Test Lead Kits

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Kits.
    These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
    The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
    Mfr. Model
    No.
    For Fluke Model No.
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Current,
    amp
    Electrical Safety
    Rating
    Includes
    Cord
    Lg.
    Color
    Each
    TL22027 II, 28 II, 83V, 87V, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 373, 374, 787, 7891,0001,00010CAT II, 1,000VTwo Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug
    Two Needle Tips
    Two Insulated Plunger Style Alligator Clips
    59"Black, Red00000000000000

    Magnetic Fluke Multimeter Hangers

    Image of ProductInUse. Front orientation. Multimeter Hangers.
    Image of Product. Front orientation. Multimeter Hangers.
    Free up your hands while using your Fluke multimeter by suspending it from this hanger.
    Mfr. Model
    No.
    For Fluke Model No.
    Each
    TPAK77IV, 83V, 87V, 88V, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 789, 1577, 15870000000000000