About Safety Ratings for Electrical Testing
More
Magnetic Hangers for Fluke Multimeters


Free up your hands while using your Fluke multimeter by suspending it from this hanger.
Manufacturer Model Number | For Fluke Model Number | Each | |
TPAK | 77IV, 83V, 87V, 88V, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 789, 1577, 1587 | 0000000 | 000000 |
Carrying Cases for Fluke Multimeters


Fluke Data-Logging Multimeters
Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
To download and analyze data on a computer, software is required (not included).
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 50,000-count multimeters show numbers up to 49,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.

Manufacturer Model Number | Data Log Capacity | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
Multimeters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 0000000 |
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 |
Multimeters with Calibration Certificate | |||||||||||||
True RMS AC Calculation | |||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 |
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 00000000 |
Download and analyze data from a Fluke data-logging multimeter. Connect your multimeter to a computer with the included USB cord.
Manufacturer Model Number | For Fluke Model Number | For Operating System | Each | |
FVF-SC2 | 287, 289 | Windows 7 and earlier | 0000000 | 0000000 |
Data-Logging Multimeters

Identify intermittent issues such as voltage spikes and temporary power flow problems—this meter records measurements from electrical tests over time. Review data in real time or save it for future analysis.
This true RMS multimeter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. This 10,000-count multimeter shows numbers up to 9,999.
Data Log Capacity | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Display Count | Includes | Each | |
True RMS AC Calculation | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
50,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | 10,000 | Alligator Clips, Test Leads | 0000000 | 0000000 |
Power Consumption Meters


Measure the amount of power your devices draw and calculate energy costs with these consumption meters. Plug them directly into an outlet, and plug your tool or appliance into the front of the meter. To track your power costs, enter the local price per kilowatt-hour (kWh) into the meter, and they’ll display the total amount you’re spending. They also help you monitor the quality of electricity coming from your outlet.
These meters meet U.S. and international safety standards. Rated CAT II, 150V, they can be safely used with most single-phase AC appliances and tools.
Max. Power, W | Max. AC Voltage | AC Voltage Accuracy | Max. AC Current, A | Current Accuracy | Max. Frequency, Hz | Max. Power Consumption, kWh | Max. Electrical Cost | Ht. | Wd. | Dp. | Specifications Met | Plug Type | Features | Each | |
1,800 | 150V AC | 1% | 15 | 1% | 65 | 9,999 | $9,999 | 5.1" | 2.6" | 1 1/2" | UL Listed, CSA Certified, CE Marked, ETL Listed | Three Prong | Backup Battery | 0000000 | 000000 |
Fluke Test Lead Kits

These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Manufacturer Model Number | For Fluke Model Number | AC Voltage | DC Voltage | Current, A | Safety Rating | Includes | Cord Lg. | Color | Each | |
TL220 | 27 II, 28 II, 83V, 87V, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 373, 374, 787, 789 | 1,000 | 1,000 | 10 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug, Two Needle Tips, Two Insulated Plunger Style Alligator Clips | 59" | Black, Red | 0000000 | 0000000 |
Fluke Test Sensors
Take temperature readings with a Fluke multimeter.
Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.

Manufacturer Model Number | For Fluke Model Number | Temperature Range, ° F | Test End | Connection End | Cord Lg. | Test End Insulation Material | Each | |
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40° to 500° | Needle Tip | Sheathed Banana Jack | 39" | PTFE | 0000000 | 000000 |
Voltage and Current Loggers
Record data over time to monitor energy consumption and troubleshoot intermittent problems such as voltage spikes. These loggers connect to a computer to download data for later analysis.
Set the sampling interval to determine how often the logger takes measurements. True RMS loggers take more accurate AC measurements than other loggers.

Batteries | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data Log Capacity | Electrical Phase | AC Voltage | AC Voltage Accuracy | Current, A | Current Accuracy | Sampling Interval | Includes | For Operating System | Software Included | Included | Size | No. Required | Each | |
10,750 | Single | 0-500 | 1V | 0-300 | 5% | 1 sec. to 18 hrs. | Carrying Case, Clamp-On Probe with 1.1" Jaw Opening, Test Leads with Alligator Clips | Windows 10 and earlier | No, Required | No | 9V | 1 | 0000000 | 0000000 |

Data Log Capacity | AC Calculation | Electrical Phase | Safety Rating | AC Voltage | AC Voltage Accuracy | DC Voltage | DC Voltage Accuracy | Sampling Interval | Includes | For Operating System | Software Included | Batteries Included | Each | |
240,000 | True RMS | Single | CAT IV, 300V | 0-600 | 0.5% | 0 to 600 | 0.5% | 125 ms to 24 hrs. | Test Leads with Alligator Clips, USB Cord | Windows 10 and earlier | Yes | Yes | 0000000 | 0000000 |
Fluke Scopemeters

Perform electrical tests, record data, and see a graph of electrical waveforms with this combination multimeter and oscilloscope. Fluke scopemeters are known for quality and durability.
To download and analyze data on a computer, software is required (not included).
When used as an oscilloscope, the scopemeter is most accurate when the frequency is at least five times the maximum signal frequency you intend to measure.
The multimeter function is true RMS, so it accurately takes AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. This 5,000-count scopemeter shows numbers up to 4,999.
Manufacturer Model Number | No. of Digital Channels | Frequency | Safety Rating | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Display Count | Data Log Capacity | Includes | Specifications Met | Measures | Batteries Included | Each | |
True RMS AC Calculation | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
123B | 2 | 0-20 MHz | CAT IV, 600V | 600 | 600 | 0.5% | 5,000 | 512 | Alligator Clips, Battery Charger, BNC Adapter, Probe Tips, Test Leads | CSA Certified | AC Voltage, Capacitance, Continuity, DC Voltage, Temperature | Yes | 0000000 | 000000000 |