Filter by
Power Consumption Data Loggers
Track power consumption over time. These loggers tap into a circuit and connect with PC software to visualize energy use and generate reports. They’re often used by energy auditors and facility managers to monitor equipment runtimes, optimize HVAC performance, and troubleshoot voltage spikes.
Set the sampling interval to determine how often the logger takes measurements. A faster sampling interval will take more readings at the expense of battery life.
Measures AC Voltage and Current
![]() |
A compact, economical choice for monitoring AC energy consumption. Includes test leads and a clamp-on probe for tapping into wiring without interrupting circuits. Requires one 9V battery as well as software for device setup and data exports, each sold separately.
Batteries | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data Log Cap. | Electrical Phase | AC Voltage, V AC | AC Voltage Accuracy, V AC | Current, amp | Current Accuracy | Sampling Interval | Includes | For Operating System | Software Included | Included | Size | No. Req. | Each | ||
10,750 | Single | 0 to 500 | -1 to 1 | 0 to 300 | 5% | 1 sec. to 18 hr. | Carrying Case, Clamp-On Probe with 1.1" Jaw Opening, Test Leads with Alligator Clips | Windows 10 or Earlier | No | No | 9V | 1 | 0000000 | 0000000 |
Measures AC and DC Voltage
![]() |
Measure, log, and track either AC or DC voltage with industry-leading accuracy. Our AC/DC logger can take as many as eight readings per second with a margin of error of just ±0.5%. Software is included for setup and analysis, along with test leads, batteries, and a USB cable to connect with your PC.
True RMS AC Calculation—True RMS loggers take more accurate AC measurements than regular loggers because they can adapt to irregular waveform readings. They’re ideal for computers, adjustable-speed drives, and other devices that distort the shape of the AC sine wave by drawing current in short pulses.
Batteries | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data Log Cap. | AC Calculation | Electrical Phase | Electrical Safety Rating | AC Voltage, V AC | AC Voltage Accuracy | DC Voltage, V DC | DC Voltage Accuracy | Sampling Interval | Includes | For Operating System | Software Included | Included | Size | No. Req. | Each | ||
240,000 | True RMS | Single | CAT IV, 300V | 0 to 600 | -0.5% to 0.5% | 0 to 600 | 0.5% | 125 ms to 24 hr. | Test Leads with Alligator Clips, USB Cord | Windows 10 or Earlier | Yes | Yes | AA | 2 | 0000000 | 0000000 |
Power Consumption Meters
![]() | ![]() |
Digital Display |
Measure the amount of power your devices draw and calculate energy costs with these consumption meters. Plug them directly into an outlet, and plug your tool or appliance into the front of the meter. To track your power costs, enter the local price per kilowatt-hour (kWh) into the meter, and they’ll display the total amount you’re spending. They also help you monitor the quality of electricity coming from your outlet.
These meters meet U.S. and international safety standards. Rated CAT II, 150V, they can be safely used with most single-phase AC appliances and tools.
Plug Type | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Power, W | Max. AC Voltage, V AC | AC Voltage Accuracy | Max. AC Current, amp | Current Accuracy | Max. Freq., Hz | Max. Power Consumption, kWh | Max. Electrical Cost | Ht. | Wd. | Dp. | Display Type | Certification | No. of Blades | Electrical Connection | Features | Each | ||
1,800 | 150 | -1% to 1% | 15 | 1% | 65 | 9,999 | $9,999 | 5.1" | 2.6" | 1 1/2" | Digital | UL Listed, CSA Certified, CE Marked, ETL Listed | 3 | Straight Blade | Backup Battery | 0000000 | 000000 |
Data-Logging Multimeters
![]() |
Identify intermittent issues such as voltage spikes and temporary power flow problems—these meters record measurements from electrical tests over time. Review data in real time or save it for future analysis.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Data Log Cap. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
50,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | 10,000 | Alligator Clips, Test Leads | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Data-Logging Multimeters
![]() |
Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Software—To download and analyze data on a computer, software is required (not included). Connect your multimeter to a computer with the included USB cord.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Data Log Cap. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 0000000 | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 | 0000000 | 00000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Oscilloscope/Multimeters
![]() |
Perform electrical tests, record data, and see a graph of electrical waveforms with this combination multimeter and oscilloscope. Fluke oscilloscope/multimeters are known for quality and durability.
To download and analyze data on a computer, software is required (not included).
When used as an oscilloscope, the oscilloscope/multimeter is most accurate when the frequency is at least five times the maximum signal frequency you intend to measure.
True RMS AC Calculation—The multimeter function is true RMS, so it accurately takes AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. This 5,000-count oscilloscope/multimeter shows numbers up to 4,999.
Mfr. Model No. | No. of Digital Channels | Freq., MHz | Electrical Safety Rating | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Display Count | Data Log Cap. | Includes | Certification | Measures | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
123B | 2 | 0 to 20 | CAT IV, 600V | 600 | 600 | 0.5% | 5,000 | 512 | Alligator Clips, Battery Charger, BNC Adapter, Probe Tips, Test Leads | CSA Certified | AC Voltage, Capacitance, Continuity, DC Voltage, Temperature | Yes | 0000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Multimeter Cases
Fluke Test Lead Sensors
![]() |
Model Number 80BK-A |
Take temperature readings with a Fluke multimeter.
Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Mfr. Model No. | For Fluke Model No. | Temp. Range, ° F | Test End Component | Connection End | Cord Lg. | Test End Insulation Material | Each | ||
---|---|---|---|---|---|---|---|---|---|
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40 to 500 | Needle Tip | Sheathed Standard Banana Jack | 39" | PTFE | 0000000 | 000000 |
Fluke Test Lead Kits
![]() |
These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Includes | Cord Lg. | Color | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
TL220 | 27 II, 28 II, 83V, 87V, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 373, 374, 787, 789 | 1,000 | 1,000 | 10 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Plunger Style Alligator Clips | 59" | Black, Red | 0000000 | 0000000 |
Magnetic Fluke Multimeter Hangers
![]() | ![]() |
Free up your hands while using your Fluke multimeter by suspending it from this hanger.
Mfr. Model No. | For Fluke Model No. | Each | ||
---|---|---|---|---|
TPAK | 77IV, 83V, 87V, 88V, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 789, 1577, 1587 | 0000000 | 000000 |