Distribution Blocks
With the help of distribution blocks, you can take a high-current wire from your power source and connect it to one or more electrical devices.
Blocks with a screw-clamp terminal input wire connection have a current rating based on NEC table 310-16 using 75° C copper wire.
Choose blocks with a bus-bar input wire connection to distribute power from flat conductors without the need for an adapter.
Extendable blocks attach to each other to create custom-sized distribution blocks.
Blocks with a jumper cable terminal connect to other blocks to increase the number of outputs.
Blocks with a quick-disconnect load connection let you attach an auxiliary device, such as a horn or light.
Blocks with a detachable cover prevent accidental contact with live circuits.
End stops (sold separately) mount at the end of a group of blocks to prevent movement.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/636/6367t11-1609766340-p9@halfx_637453415623016932.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/764/7641k35-p2225-@halfx_637111277223885079.png?ver=imagenotfound)
Distribution Blocks | End Stops | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Connections Per Circuit | Each | |||||||||||||
Current Per Circuit, A | Voltage | Input (For Wire Gauge) | Output (For Wire Gauge) | Wd. | Ht. | Dp. | Environmental Rating | Specifications Met | Features | Each | 1-24 | 25-Up | ||
DIN-Rail Mount | ||||||||||||||
1-Circuit Blocks | ||||||||||||||
80 | 1,000V AC/1,000V DC | 3 (14-4) | 4 (14-10) | 1 1/8" | 2 5/8" | 2" | IP20, NEMA 1 | UL Recognized Component, CE Marked | Jumper Cable Terminal | 0000000 | 000000 | 0000000 | 00000 | 00000 |
115 | 600V AC/600V DC | 1 (14-2) | 1 (14-2) | 3/4" | 4 1/8" | 1 11/16" | IP20 | UL Listed, CE Marked, UL 94 V-0 | __ | 0000000 | 00000 | 000000 | 00 | 00 |
115 | 600V AC/600V DC | 1 (14-2) | 4 (14-10) | 3/4" | 4 1/8" | 1 11/16" | IP20 | UL Listed, CSA Certified, CE Marked, UL 94 V-0 | __ | 0000000 | 00000 | 000000 | 00 | 00 |
115 | 1,000V AC/1,000V DC | 1 (8-2) | 1 (10-6), 6 (14-6) | 1 1/8" | 3" | 2" | IP20, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | Jumper Cable Terminal | 0000000 | 00000 | 0000000 | 000 | 000 |
160 | 1,000V AC/1,000V DC | 1 (6-2/0) | 1 (10-6), 6 (14-6) | 1 1/8" | 3" | 2" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | Jumper Cable Terminal | 0000000 | 00000 | 0000000 | 000 | 000 |
175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 1" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, UL 94 V-0, C-UL Listed | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 1" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, UL 94 V-0, C-UL Listed | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 1" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, C-UL Listed | Detachable Cover, Quick-Disconnect Load Connection | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 1" | 3 1/4" | 3 3/16" | __ | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 1,000V AC/1,000V DC | 2 (6-2/0) | 10 (14-6) | 1 13/16" | 2 7/8" | 2 1/16" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | Jumper Cable Terminal | 0000000 | 00000 | 0000000 | 000 | 000 |
200 | 600V AC/600V DC | 1 (14-3/0) | 4 (14-2) | 1 1/8" | 3 5/8" | 2 11/16" | IP20 | UL Listed, CSA Certified, CE Marked, UL 94 V-0 | __ | 0000000 | 00000 | 000000 | 00 | 00 |
230 | 1,000V AC/1,000V DC | 1 (2-250 MCM) | 2 (14-2), 5 (14-6), 4 (14-8) | 1 13/16" | 3 3/4" | 2 3/8" | __ | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | __ | 0000000 | 00000 | 0000000 | 000 | 000 |
335 | 600V AC/600V DC | 1 (6-400 MCM) | 8 (14-2) | 2 1/4" | 4 3/4" | 3 5/16" | IP20 | UL Recognized Component, CE Marked, UL 94 V-0 | __ | 0000000 | 00000 | 000000 | 00 | 00 |
335 | 1,000V AC/1,000V DC | 1 (3/0-400 MCM) | 2 (14-2), 5 (14-6), 4 (14-8) | 1 13/16" | 3 3/4" | 2 3/8" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | Jumper Cable Terminal | 0000000 | 00000 | 0000000 | 000 | 000 |
2-Circuit Blocks | ||||||||||||||
175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 2" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, UL 94 V-0, C-UL Listed | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, UL 94 V-0, C-UL Listed | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, C-UL Listed | Detachable Cover, Quick-Disconnect Load Connection | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 2" | 3 1/4" | 3 3/16" | __ | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
3-Circuit Blocks | ||||||||||||||
115 | 1,000V AC/1,000V DC | 1 (8-2) | 1 (10-6), 6 (14-6) | 3 5/16" | 3" | 2" | IP20, NEMA 1 | UL Recognized Component, CE Marked | __ | 0000000 | 00000 | 0000000 | 000 | 000 |
175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 2 5/8" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, UL 94 V-0, C-UL Listed | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2 5/8" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, UL 94 V-0, C-UL Listed | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2 5/8" | 3 1/4" | 3 3/16" | __ | UL Listed, CE Marked, C-UL Listed | Detachable Cover, Quick-Disconnect Load Connection | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 2 5/8" | 3 1/4" | 3 3/16" | __ | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | Detachable Cover | 0000000 | 00000 | 000000 | 00 | 00 |
175 | 1,000V AC/1,000V DC | 1 (6-2/0) | 1 (10-6), 6 (14-6) | 3 5/16" | 3" | 2" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | __ | 0000000 | 00000 | 0000000 | 000 | 000 |
Surface Mount | ||||||||||||||
1-Circuit Blocks | ||||||||||||||
335 | 600V AC/600V DC | 2 (14-4/0) | 8 (14-2) | 2 1/4" | 4 3/8" | 3 3/16" | IP20 | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | Extendable | 0000000 | 00000 | 000000 | 00 | 00 |
760 | 600V AC | 2 (4-4/0) | 8 (14-2/0) | 2 1/2" | 4.63" | 3 3/8" | IP20 | UL Listed, CSA Certified, CE Marked, UL 94 V-0 | Extendable | 0000000 | 00000 | 000000 | 00 | 00 |
760 | 600V AC/600V DC | 2 (4-4/0) | 12 (14-4) | 2 1/2" | 4.63" | 3 3/8" | IP20 | UL Listed, CSA Certified, CE Marked, UL 94 V-0 | Extendable | 0000000 | 00000 | 000000 | 00 | 00 |
3-Circuit Blocks | ||||||||||||||
335 | 600V AC/600V DC | 1 (14-4/0) | 6 (14-2) | 5 5/8" | 5" | 3 15/16" | __ | UL Listed, C-UL Listed | __ | 0000000 | 000000 | 000000 | 00 | 00 |
350 | 600V AC/600V DC | 2 (14-2/0) | 6 (14-4) | 5 5/8" | 5" | 3 15/16" | __ | UL Listed, C-UL Listed | __ | 0000000 | 000000 | 000000 | 00 | 00 |
510 | 600V AC/600V DC | 2 (6-4/0) | 8 (14-2) | 5 5/8" | 5" | 3 15/16" | __ | UL Listed, C-UL Listed | __ | 0000000 | 000000 | 000000 | 00 | 00 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/636/6367t35-@halfx_1688745828.png?ver=imagenotfound)
No. of Connections Per Circuit | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Current Per Circuit, A | Voltage | Input (For Wire Gauge) | Output (For Wire Gauge) | Terminal Size | Wd. | Ht. | Dp. | Specifications Met | Features | Each | |
DIN-Rail Mount | |||||||||||
1-Circuit Blocks | |||||||||||
200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 1" | 3 1/4" | 3 3/16" | CE Marked, UL Listed, C-UL Listed | Detachable Cover | 0000000 | 000000 |
2-Circuit Blocks | |||||||||||
200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 2" | 3 1/4" | 3 3/16" | CE Marked, UL Listed, C-UL Listed | Detachable Cover | 0000000 | 00000 |
3-Circuit Blocks | |||||||||||
200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 2 5/8" | 3 1/4" | 3 3/16" | CE Marked, UL Listed, C-UL Listed | Detachable Cover | 0000000 | 00000 |
Surface Mount | |||||||||||
1-Circuit Blocks | |||||||||||
310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 2" | 4" | 3 1/2" | CE Marked, UL Listed, C-UL Listed | Detachable Cover | 0000000 | 00000 |
2-Circuit Blocks | |||||||||||
310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 3 5/8" | 4" | 3 1/2" | CE Marked, UL Listed, C-UL Listed | Detachable Cover | 0000000 | 00000 |
3-Circuit Blocks | |||||||||||
310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 5 3/8" | 4" | 3 1/2" | CE Marked, UL Listed, C-UL Listed | Detachable Cover | 0000000 | 000000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/636/6367t55--3879ee87f651618853028-p9@halfx_637544319804616467.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/764/7641k35-p2225-@halfx_637111277223885079.png?ver=imagenotfound)
Distribution Blocks | End Stops | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Connections Per Circuit | Bus Bar, mm | Each | |||||||||||||
Current Per Circuit, A | Voltage | Input | Output (For Wire Gauge) | Wd. | Ht. | Dp. | Wd. | Thick. | Environmental Rating | Specifications Met | Each | 1-24 | 25-Up | ||
DIN-Rail Mount | |||||||||||||||
1-Circuit Blocks | |||||||||||||||
160 | 1,000V AC/1,000V DC | 1 | 6 (14-6) | 1 1/8" | 3" | 2" | 12 | 4 | IP20, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | 0000000 | 000000 | 0000000 | 00000 | 00000 |
420 | 1,000V AC/1,000V DC | 1 | 2 (14-2), 4 (14-8), 5 (14-6) | 1 13/16" | 4" | 2 3/8" | 25 | 10 | IP20, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked, UL 94 V-0 | 0000000 | 00000 | 0000000 | 000 | 000 |
Harsh Environment High-Current Distribution Bars
![](/prerenderstable/mvPRE/contents/gfx/imagecache/929/9290t32c1-d01b-digital1560950893-p9@halfx_636965297071133507.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/929/9290t12c1-d01b-digital-master1560545336-p9@halfx_636961267597904853.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/929/9290t14c1-d01b-digital-master1560888673-p9@halfx_636964674755355566.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/929/9290t11--67d762d37061567171283-p9@halfx_637027501043449800.png?ver=imagenotfound)
Protect connections against corrosion. These bars are tin-plated copper and have stainless steel terminals. Also known as bus bars, they serve as connection points between wires with ring or spade terminals. The underside is sealed, so the bars can be safely mounted to conductive surfaces.
Covers protect the top of the bar and prevent accidental contact with live circuits.
For technical drawings and 3-D models, click on a part number.
Distribution Bars | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current | Terminals | Mounting Holes | Covers | |||||||||||
300V AC | 48V DC | No. Per Circuit | Size | Lg. | Wd. | Ht. | Mounting Fasteners Included | Dia. | No. of | Specifications Met | Each | Each | ||
Stud Terminals | ||||||||||||||
1-Circuit Bars | ||||||||||||||
100A | 100A | 4 | No. 10 | 4 3/16" | 7/8" | 1 1/8" | No | 0.21" | 2 | CE Marked | 0000000 | 000000 | 0000000 | 00000 |
130A | 150A | 4 | 1/4" | 5 7/8" | 1 1/4" | 1 1/2" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 0000 |
250A | 250A | 4 | 5/16" | 5 7/8" | 1 1/2" | 1 11/16" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 00000 |
250A | 250A | 6 | 5/16" | 7 3/4" | 1 1/2" | 1 11/16" | No | 0.21" | 2 | CE Marked | 000000 | 00000 | 0000000 | 00000 |
Distribution Bars | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current | Terminals | Mounting Holes | Covers | |||||||||||
300V AC | 48V DC | No. Per Circuit | Size | Lg. | Wd. | Ht. | Mounting Fasteners Included | Dia. | No. of | Specifications Met | Each | Each | ||
Screw Terminals | ||||||||||||||
2-Circuit Blocks | ||||||||||||||
100A | 100A | 5 | No. 8 | 3" | 1 13/16" | 9/16" | No | 0.21" | 2 | CE Marked | 0000000 | 000000 | 0000000 | 000000 |
100A | 100A | 10 | No. 8 | 5 1/16" | 1 13/16" | 9/16" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 00000 |
Distribution Bars | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current | Stud Terminals | Screw Terminals | Mounting Holes | Covers | ||||||||||||
300V AC | 48V DC | No. Per Circuit | Size | No. Per Circuit | Size | Lg. | Wd. | Ht. | Mounting Fasteners Included | Dia. | No. of | Specifications Met | Each | Each | ||
Stud and Screw Terminals | ||||||||||||||||
1-Circuit Bars | ||||||||||||||||
100A | 100A | 2 | No. 10 | 5 | No. 8 | 4 3/16" | 7/8" | 1 1/8" | No | 0.21" | 2 | CE Marked | 0000000 | 000000 | 0000000 | 00000 |
130A | 150A | 2 | 1/4" | 10 | No. 8 | 5 7/8" | 1 1/4" | 1 1/2" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 0000 |
130A | 150A | 2 | 1/4" | 20 | No. 8 | 9 1/8" | 1 1/4" | 1 1/2" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 0000 |
250A | 250A | 2 | 5/16" | 6 | No. 10 | 5 7/8" | 1 1/2" | 1 11/16" | No | 0.21" | 2 | CE Marked | 000000 | 00000 | 0000000 | 00000 |
250A | 250A | 2 | 5/16" | 12 | No. 10 | 7 3/4" | 1 1/2" | 1 11/16" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 00000 |
545A | 600A | 4 | 3/8" | 4 | No. 8 | 7" | 2" | 2" | No | 0.26" | 4 | CE Marked | 000000 | 000000 | 0000000 | 00000 |
545A | 600A | 8 | 3/8" | 4 | No. 8 | 11 3/8" | 2" | 2" | No | 0.39" | 4 | CE Marked | 000000 | 000000 | 000000 | 00 |
2-Circuit Bars | ||||||||||||||||
130A | 150A | 2 | 1/4" | 5 | No. 10 | 4 7/8" | 2 9/16" | 1 1/4" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 000000 | 00 |
Modular Distribution Bars
![](/prerenderstable/mvPRE/contents/gfx/imagecache/152/1529t11p1-d01bl1553883106@halfx_636894649280346043.png?ver=imagenotfound)
Build your own distribution system for neutral and grounding applications by adding terminal blocks to these bars. Slide blocks onto the bar, also known as a bus bar, and then attach mounting brackets to the bar. All wires make contact with the bar, distributing the current among the terminal blocks.
Terminal blocks have screw-clamp terminals that secure the wire as well as the block to the bar. Blocks are UL recognized for grounding applications.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/152/1529t11p1-d01b-digital@halfx_636876563595789325.png?ver=imagenotfound)
Terminal Blocks | Blank Marker Cards | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits | For Wire Gauge | Wire Connection Type | Wd., mm | Lg., mm | Ht., mm | Specifications Met | Pkg. Qty. | Pkg. | Pkg. Qty. | Pkg. | ||
1 | 22-10 | Screw-Clamp Terminals | 7.5 | 30 | 23.3 | UL Recognized Component | 5 | 0000000 | 00000 | 100 | 0000000 | 00000 |
1 | 10-4 | Screw-Clamp Terminals | 9.8 | 36 | 23.3 | UL Recognized Component | 5 | 0000000 | 0000 | 100 | 0000000 | 0000 |
1 | 8-2 | Screw-Clamp Terminals | 14.5 | 45 | 27.3 | UL Recognized Component | 5 | 0000000 | 0000 | 100 | 0000000 | 0000 |
Distribution Blocks for Nano M8 and Micro M12 Cords
![](/prerenderstable/mvPRE/contents/gfx/imagecache/248/2481n1p1-d01b-digital@halfx_636582863800000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/248/2481n3p1-d01b-digital@halfx_636582863860000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/713/7138k51l1-d01b--master1559752476-p9@halfx_636953312833576356.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/689/6897k35l4-digital-master1559829102-p9@halfx_636954079786823513.png?ver=imagenotfound)
Connect multiple devices to these distribution blocks to create a network between equipment. They’re rated IP67 for protection from dust and submersion and IP65 for protection from low-pressure washdown.
Socket | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal Output Type | Housing Thread Size | No. of Outlets | No. of Poles | Coding | Face Dia. | Cord Lg., ft. | Current, A | Voltage | Wire Gauge | Cord OD | Environmental Rating | Specifications Met | Temp. Range, °F | Color | Each | |
Socket (Internal Thread) with Wire Leads | ||||||||||||||||
PNP | M8 | 4 | 3 | __ | 0.2" | 16 | 2 | 24V DC | 22 | 0.27" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 0000000 |
PNP | M8 | 4 | 3 | __ | 0.2" | 32 | 2 | 24V DC | 22 | 0.27" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 8 | 3 | __ | 0.2" | 16 | 2 | 24V DC | 22 | 0.34" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 8 | 3 | __ | 0.2" | 32 | 2 | 24V DC | 22 | 0.34" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M12 | 4 | 4 | A | 0.3" | 16 | 4 | 24V DC | 22 | 0.33" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 4 | 4 | A | 0.3" | 32 | 4 | 24V DC | 22 | 0.33" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 8 | 4 | A | 0.3" | 16 | 4 | 24V DC | 22 | 0.36" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 8 | 4 | A | 0.3" | 32 | 4 | 24V DC | 22 | 0.36" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |