Output Voltage Output Voltage | Show |
---|
|
Output Voltage Output Voltage | Hide |
---|
Transformer Type Transformer Type |
---|
|
Output Connection Type Output Connection Type |
---|
![]() | Hardwire |
Electrical Phase Electrical Phase |
---|
|
Transformer Voltage Function Transformer Voltage Function |
---|
|
Application Application |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Output Wire Connection Type Output Wire Connection Type |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Input Connection NEMA Style Input Connection NEMA Style |
---|
|
Input Plug Type Input Plug Type |
---|
|
Mounting Location Mounting Location |
---|
|
Input Wire Connection Type Input Wire Connection Type |
---|
|
For Fuse Type For Fuse Type |
---|
|
About AC to AC Voltage Transformers
For single-phase equipment, use this formula to find power output: VA = Volts × Amps
For three-phase equipment, use this formula to find power output: VA = Volts × Amps × 1.73
More
Low-Current AC to AC Transformers


Power low-voltage devices such as alarms and sensors.
Voltage | |||||||||
---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Input Plug Type (NEMA Style) | Ht. | Wd. | Dp. | Specifications Met | Each | |
Single Phase—Plug Input and Screw Terminals Output | |||||||||
Step Down Voltage | |||||||||
120V AC | 12V AC | 20 | Two Prong (1-15) | 3.2" | 2.6" | 1.9" | UL Listed | 0000000 | 000000 |
Harsh Environment High-Inrush Panel-Mount AC to AC Transformers


Sealed coils protect against dust, dirt, oil, and moisture. These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers. Choose a transformer with multiple output voltages to simultaneously power multiple devices that require different output voltages.
Voltage | For Fuse | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Type | O'all Dia. | Specifications Met | Each | |
Single Phase—Screw Terminals Input and Output | ||||||||||
Step Down Voltage—Input Fuse Block | ||||||||||
120V AC/240V AC | 12V AC/24V AC | 50 | 4" | 3" | 3.8" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 75 | 4" | 3" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
120V AC/240V AC | 12V AC/24V AC | 100 | 4.4" | 3.4" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 150 | 4.7" | 3.8" | 4.4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 250 | 5.3" | 4 1/2" | 4.6" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 500 | 6" | 5.3" | 5.3" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
Step Down Voltage—Output Fuse Block | ||||||||||
120V AC/240V AC | 12V AC | 50 | 3.1" | 3" | 3.8" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
120V AC/240V AC | 12V AC | 75 | 3.1" | 3" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
120V AC/240V AC | 12V AC | 100 | 3 1/2" | 3.4" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC | 150 | 3.8" | 3.8" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 12V AC | 50 | 3.1" | 3" | 3.8" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
240V AC/480V AC | 12V AC | 150 | 3.8" | 3.8" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
High-Inrush Panel-Mount AC to AC Transformers
These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers.
Input and output fuse blocks are built-in and top-mounted to save panel space and allow quick installation.

Voltage | ||||||||
---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Specifications Met | Each | |
Step Down Voltage | ||||||||
120V AC/240V AC | 12V AC/24V AC | 50 | 2.8" | 3" | 3.3" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 75 | 2.8" | 3" | 3.8" | UL Listed, C-UL Listed | 0000000 | 00000 |
120V AC/240V AC | 12V AC/24V AC | 100 | 3.1" | 3.4" | 3.8" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 150 | 3.4" | 3.8" | 4.3" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 250 | 4" | 4 1/2" | 4 1/2" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 350 | 4" | 4 1/2" | 5.3" | UL Listed, CSA Certified | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 500 | 4.6" | 5.3" | 5.8" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 750 | 4.7" | 5.3" | 7" | UL Listed, C-UL Listed | 0000000 | 000000 |

Voltage | For Fuse | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Type | O'all Dia. | Specifications Met | Each | |
Step Down Voltage | ||||||||||
120V AC/240V AC | 12V AC/24V AC | 50 | 4" | 3" | 3.6" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 0000000 |