Filter by
Pressure Set Point
Maximum Switching Current @ Voltage
Approximate Difference Between Set Point and Reset Point
Measurement Unit
Wire Connection
Housing Material
Connection Material
Operation Type
REACH
U.S.–Mexico–Canada Agreement (USMCA) Qualifying
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Certification
Electrical Connection
Pressure and Vacuum Switches
Set Point | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Vacuum, in. Hg | Approx. Difference Between Set Point and Reset Point, psi | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current @ Voltage | Process Temp. Range, ° F | Connection Material | For Use With | Enclosure Rating | Each | |||
Screw-Terminal Wire Connection | ||||||||||||||
1/4 NPT Female | ||||||||||||||
| 0 to 15 | 0 to 30 | 1.5 | 15 | 250 | ±1% | 15 amp @ 125V AC 15 amp @ 250V AC 15 amp @ 480V AC 6 amp @ 30V DC 500 mA @ 125V DC 250 mA @ 250V DC | 20 to 300 | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66, NEMA 4X | 3871N11 | 0000000 | ||
| 0 to 30 | 0 to 30 | 2.25 | 30 | 250 | ±1% | 15 amp @ 125V AC 15 amp @ 250V AC 15 amp @ 480V AC 6 amp @ 30V DC 500 mA @ 125V DC 250 mA @ 250V DC | 20 to 300 | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66, NEMA 4X | 3871N12 | 000000 | ||
| 0 to 60 | 0 to 30 | 4 | 60 | 250 | ±1% | 15 amp @ 125V AC 15 amp @ 250V AC 15 amp @ 480V AC 6 amp @ 30V DC 500 mA @ 125V DC 250 mA @ 250V DC | 20 to 300 | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66, NEMA 4X | 3871N13 | 000000 | ||
Electronic Pressure and Vacuum Switches for Compressed Air
Set Point | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Vacuum, in. Hg | Approx. Difference Between Set Point and Reset Point | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current @ Voltage | Process Temp. Range, ° F | Connection Material | For Use With | Enclosure Rating | Each | |||
Switches (PNP) | ||||||||||||||
Wire Leads—1/8 NPT Male | ||||||||||||||
| 0 to 14 1/2 | 0 to 29 | Adjustable | 14.5 | 72 | ±0.2% | 25 mA @ 24V DC | 25 to 120 | Nickel-Plated Brass | Air, Argon, Inert Gas, Nitrogen | IP40 | 3875N11 | 000000 | ||
Switches with 1 Configurable Output (PNP, NPN, IO-Link) | ||||||||||||||
Wire Leads—1/8 NPT Male | ||||||||||||||
| 0 to 14 1/2 | 0 to 29 | Adjustable | 14.5 | 72 | ±0.2% | 35 mA @ 24V DC | 25 to 120 | Nickel-Plated Brass | Air, Argon, Inert Gas, Nitrogen | IP65 | 3875N12 | 00000 | ||
Dual-Setpoint Electronic Pressure and Vacuum Switches for Compressed Air
Set Point | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Vacuum, in. Hg | Approx. Difference Between Set Point and Reset Point | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Output Digital Signal | Accuracy | Max. Switching Current @ Voltage | Process Temp. Range, ° F | Connection Material | For Use With | Enclosure Rating | Each | |||
Wire Lead Connection | |||||||||||||||
1/8 NPT Male | |||||||||||||||
| 0 to 14 1/2 | 0 to 29 | Adjustable | 14.5 | 72 | PNP | ±0.2% | 35 mA @ 24V DC | 25 to 120 | Nickel-Plated Brass | Air, Argon, Inert Gas, Nitrogen | IP65 | 3878N11 | 0000000 | ||