McMaster-Carr logo
    Filter by
    System of Measurement
    Connection Location
    Dial Diameter
    Thread Type
    Industrial Info Compare
    Dial Type
    Scale Type
    Display Type
    Measures
    Connection Material
    Connects To
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Compare
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    67 Products
    About Pressure Gauges
    industrial info icon

    Find a gauge with the right connection material and dial type—many with traceable calibration certificates.

    Gas Pressure Gauges

    Use these gauges with pumps, filters, regulators, and in process lines to monitor the pressure of compressed gas. Mount them with the dial face upright. Gauges for use with acetylene can also be used in welding applications.
    Brass Case with Brass Connection—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Pressure Gauges. Gas Pressure Gauges, Single Scale, Bottom Connection.
    Image of Attribute. Bottom Connection. Front orientation. Gas Pressure Gauges, Bottom Connection.

    Bottom Connection

    Bottom

    Connection

    Gauges with brass case are cleaned to meet ASME B40.1, Level IV for oxygen service.
    Temp.
    Range, ° F
    Bottom
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Process
    For Use With
    Accuracy
    Choose a Pressure Range
    Each
    Upright Mount
     
    NPT Male
    2"1/4
    -40 to 140-40 to 140Acetylene
    Air
    Carbon Dioxide
    Oxygen
    ±2% Midscale (Grade B)0 to 30 psi, 0 to 60 psi, 0 to 100 psi, 0 to 200 psi, 0 to 400 psi, 0 to 600 psi, 0 to 1,000 psi, 0 to 2,000 psi, 0 to 3,000 psi, 0 to 4,000 psi32255K7000000
    2 1/2"1/4
    -40 to 140-40 to 140Acetylene
    Air
    Carbon Dioxide
    Oxygen
    ±2% Midscale (Grade B)0 to 30 psi, 0 to 60 psi, 0 to 100 psi, 0 to 200 psi, 0 to 400 psi, 0 to 600 psi, 0 to 1,000 psi, 0 to 2,000 psi, 0 to 3,000 psi, 0 to 4,000 psi32255K600000
     
    304 Stainless Steel Case with Brass Connection—Dual Scale (Pounds per Square Inch, Kilopascals)
    Image of Product. Front orientation. Pressure Gauges. Gas Pressure Gauges, Dual Scale, Bottom Connection.
    Image of Product. Front orientation. Pressure Gauges. Gas Pressure Gauges, Dual Scale, Center-Back Connection.
    Image of Product. Front orientation. Pressure Gauges. Gas Pressure Gauges, Dual Scale, Lower-Back Connection.

    Bottom Connection

    Center-Back

    Connection

    Lower-Back Connection

    Image of Attribute. Bottom Connection. Front orientation. Gas Pressure Gauges, Bottom Connection.
    Image of Attribute. Center-Back Connection. Front orientation. Gas Pressure Gauges, Center-Back Connection.

    Bottom

    Connection

    Center-Back

    Connection

    Image of Attribute. Lower-Back
Connection. Front orientation. Gas Pressure Gauges, Lower-Back Connection.

    Lower-Back Connection

    Gauges with 304 stainless steel case are cleaned and bagged to meet ASME B40.1, Level IV for oxygen service.
    Temp.
    Range, ° F
    Bottom
    Connection
    Center-Back
    Connection
    Lower-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Process
    For Use
    With
    Accuracy
    Choose a Pressure Range
    Each
    Each
    Each
    Upright Mount
     
    NPT Male
    2 1/2"1/4
    -40 to 140-40 to 140Oxygen±1% Midscale (Grade A)0 to 15 psi/0 to 102 kPa; 0 to 30 psi/0 to 205 kPa; 0 to 100 psi/0 to 680 kPa; 0 to 200 psi/0 to 1,350 kPa; 0 to 300 psi/0 to 2,050 kPa; 0 to 600 psi/0 to 4,100 kPa9816T110000009816T21000000———0
    4"1/4
    -40 to 140-40 to 140Oxygen±1% Full Scale (Grade 1A)0 to 15 psi/0 to 103 kPa; 0 to 30 psi/0 to 206 kPa; 0 to 100 psi/0 to 680 kPa; 0 to 200 psi/0 to 1,360 kPa; 0 to 300 psi/0 to 2,060 kPa; 0 to 600 psi/0 to 4,100 kPa9816T12000000———09816T220000000
     

    Gauge Guards

    Also known as isolators or diaphragm seals, these protect gauges from corrosive process media. Fill guards with hydraulic oil (not included) before use.
    316 Stainless Steel Body
    Image of Product. Bottom orientation. 316 Stainless Steel Body. Gauge Guards.
    316 stainless steel guards provide excellent corrosion and chemical resistance and can handle higher temperatures and pressures than plastic guards.
    Pipe
    Connections
    Inlet
    Outlet
    Gasket Material
    For Use With
    Min. Pressure,
    psi
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Ht.
    Each
    1/4 NPT Female1/4 NPT Female316 Stainless Steel
    Acetylene, Air, Ammonia, Argon, Boric Acid, Carbon Dioxide, Deionized Water, Diesel Fuel, Ethanol, Ethyl Alcohol, Gasoline, Hydraulic Fluid, Hydraulic Oil, Hydrogen, Liquid Nitrogen, Mineral Oil, Natural Gas, Nitrogen, Oxygen, Refrigerant, Salt Water, Sodium Hypochlorite (Bleach), Steam, Water602,500 psi @ 72° F3001 3/4"3882K510000000
    1/2 NPT Female1/4 NPT Female316 Stainless Steel
    Acetylene, Air, Ammonia, Argon, Boric Acid, Carbon Dioxide, Deionized Water, Diesel Fuel, Ethanol, Ethyl Alcohol, Gasoline, Hydraulic Fluid, Hydraulic Oil, Hydrogen, Liquid Nitrogen, Mineral Oil, Natural Gas, Nitrogen, Oxygen, Refrigerant, Salt Water, Sodium Hypochlorite (Bleach), Steam, Water602,500 psi @ 72° F3001 3/4"3882K52000000
    1/2 NPT Female1/2 NPT Female316 Stainless Steel
    Acetylene, Air, Ammonia, Argon, Boric Acid, Carbon Dioxide, Deionized Water, Diesel Fuel, Ethanol, Ethyl Alcohol, Gasoline, Hydraulic Fluid, Hydraulic Oil, Hydrogen, Liquid Nitrogen, Mineral Oil, Natural Gas, Nitrogen, Oxygen, Refrigerant, Salt Water, Sodium Hypochlorite (Bleach), Steam, Water602,500 psi @ 72° F3001 1/2"3882K53000000
    316 Stainless Steel Body with 1/4 NPT Female Drain Port
    Image of Product. Front orientation. 316 Stainless Steel Body. Gauge Guards, 1/4 NPT Female Drain Port.
    316 stainless steel guards provide excellent corrosion and chemical resistance and can handle higher temperatures and pressures than plastic guards.
    Guards with drain port allow you to remove process media.
    Pipe
    Connections
    Inlet
    Outlet
    Gasket Material
    For Use With
    Min. Pressure,
    psi
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Ht.
    Each
    1/4 NPT Female1/4 NPT Female316 Stainless Steel
    Acetylene, Air, Ammonia, Argon, Boric Acid, Carbon Dioxide, Deionized Water, Diesel Fuel, Ethanol, Ethyl Alcohol, Gasoline, Hydraulic Fluid, Hydraulic Oil, Hydrogen, Liquid Nitrogen, Mineral Oil, Natural Gas, Nitrogen, Oxygen, Refrigerant, Salt Water, Sodium Hypochlorite (Bleach), Steam, Water602,500 psi @ 72° F3002"3882K540000000
    1/2 NPT Female1/4 NPT Female316 Stainless Steel
    Acetylene, Air, Ammonia, Argon, Boric Acid, Carbon Dioxide, Deionized Water, Diesel Fuel, Ethanol, Ethyl Alcohol, Gasoline, Hydraulic Fluid, Hydraulic Oil, Hydrogen, Liquid Nitrogen, Mineral Oil, Natural Gas, Nitrogen, Oxygen, Refrigerant, Salt Water, Sodium Hypochlorite (Bleach), Steam, Water602,500 psi @ 72° F3002"3882K55000000
    1/2 NPT Female1/2 NPT Female316 Stainless Steel
    Acetylene, Air, Ammonia, Argon, Boric Acid, Carbon Dioxide, Deionized Water, Diesel Fuel, Ethanol, Ethyl Alcohol, Gasoline, Hydraulic Fluid, Hydraulic Oil, Hydrogen, Liquid Nitrogen, Mineral Oil, Natural Gas, Nitrogen, Oxygen, Refrigerant, Salt Water, Sodium Hypochlorite (Bleach), Steam, Water602,500 psi @ 72° F3002"3882K56000000

    Sanitary Gauge Guards

    Keeping corrosive substances from touching pressure gauges used in food-processing and pharmaceutical plants, these guards have a sanitary design. Made of 316 stainless steel, they won’t rust from frequent washdowns with harsh cleaners and sanitizers. They have continuously-welded seams and polished surfaces, so there aren’t any pits for bacteria to grow in. Removing them for cleaning and maintenance is easy thanks to their quick-clamp connection, which is sometimes called a tri-clamp.
    Also known as isolators and diaphragm seals, these guards have a 316 stainless steel gasket to shield the pressure gauges from corrosion. Before use, fill the guards with fluid such as glycerin or silicone that’s suitable for food contact.
    316 Stainless Steel Body
    Image of Product. Front orientation. Gauge Guards. Sanitary Gauge Guards.
    Outlet Quick-Clamp
    Tube Connection
    Inlet Pipe
    Connection
    For Tube
    OD
    Flange
    OD
    Gasket Material
    For Use With
    Min. Pressure,
    psi
    Max. Pressure
    @ Temp.
    Max.
    Temp.
    Ht.
    Interior Smoothness,
    Ra
    Each
    1/4 NPT Female1 1/2"1.984"316 Stainless Steel
    Acetylene, Air, Ammonia, Beverage, Boric Acid, Carbon Dioxide, Diesel Fuel, Ethanol, Food, Gasoline, Hydraulic Fluid, Hydrogen, Oxygen, Pharmaceuticals, Wastewater, Water30Not RatedNot Rated1 3/8"326363N110000000
    1/4 NPT Female2"2.516"316 Stainless Steel
    Acetylene, Air, Ammonia, Beverage, Boric Acid, Carbon Dioxide, Diesel Fuel, Ethanol, Food, Gasoline, Hydraulic Fluid, Hydrogen, Oxygen, Pharmaceuticals, Wastewater, Water30Not RatedNot Rated1 1/8"326363N12000000
    1/2 NPT Female1 1/2"1.984"316 Stainless Steel
    Acetylene, Air, Ammonia, Beverage, Boric Acid, Carbon Dioxide, Diesel Fuel, Ethanol, Food, Gasoline, Hydraulic Fluid, Hydrogen, Oxygen, Pharmaceuticals, Wastewater, Water30Not RatedNot Rated1 3/8"326363N13000000

    Quick-Install Pressure Test Fittings

    Image of System. Front orientation. Contains Annotated. Pressure Test Fittings. Quick-Install Pressure Test Fittings.
    Thread these fittings onto your testing equipment by hand for a secure connection in testing applications—no tools, tape, or sealant required. Use them with gauges and other equipment as a temporary connection. When pressure is applied, the O-ring on the outlet presses against the testing equipment, creating a tight seal.
    Intermittent Swivel—Adapters with intermittent swivel rotate 360° until tightened for easy installation.
    Pipe
    Size
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Gasket Material
    For Use With
    Each
    NPT Female Inlet × NPT Male Outlet Adapter with Intermittent Swivel
    Image of Product. Front orientation. Pressure Test Fittings. Quick-Install Pressure Test Fittings, NPT Female Inlet × NPT Male Outlet Adapter with Intermittent Swivel.
     
    416 Stainless Steel
    1/8
    5,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K710000000
    1/4
    5,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K72000000
    3/8
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K73000000
    1/2
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K74000000
    3/4
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K75000000
    1
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K81000000
     
    NPT Male Inlet × NPT Female Outlet Adapter
    Image of Product. Front orientation. Pressure Test Fittings. Quick-Install Pressure Test Fittings, NPT Male Inlet × NPT Female Outlet Adapter.
     
    416 Stainless Steel
    1/8
    5,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K21000000
    1/4
    5,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K22000000
    3/8
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K23000000
    1/2
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K24000000
    3/4
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K25000000
    1
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K26000000
     
    NPT Male Inlet × NPT Female Outlet Adapter with Intermittent Swivel
    Image of Product. Front orientation. Pressure Test Fittings. Quick-Install Pressure Test Fittings, NPT Male Inlet × NPT Female Outlet Adapter with Intermittent Swivel.
     
    416 Stainless Steel
    1/8
    5,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K31000000
    1/4
    5,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K32000000
    3/8
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K33000000
    1/2
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K34000000
    3/4
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K35000000
    1
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K36000000
     
    NPT Male Inlet Plug
    Image of Product. Front orientation. Pressure Test Fittings. Quick-Install Pressure Test Fittings, NPT Male Inlet Plug.
     
    416 Stainless Steel
    1/8
    5,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K11000000
    1/4
    5,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K12000000
    3/8
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K13000000
    1/2
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K14000000
    3/4
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K15000000
    1
    4,000-65 to 212Polyurethane Rubber
    Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water2438K16000000
     

    Pressure Transmitters for Oxygen

    Adhere to safety standards and monitor pressure when working with high concentrations of oxygen. These transmitters are cleaned following ASME B40.100 IV guidelines and are sealed in an airtight bag to prevent contamination before use. Also known as transducers, they convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    These transmitters are rated NEMA 4X and IP65 for protection from dust, weather, washdown, and corrosion. UL and C-UL recognized components and CE marked, they also meet American, Canadian, and European safety standards.
    With an output current, they connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    4 mA to 20 mA Output Signal—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters for Oxygen.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use
    With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 3060609 to 362 3/8"1 5/16"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Oxygen±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553914A110000000
    0 to 601201209 to 362 3/8"1 5/16"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Oxygen±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553914A12000000
    0 to 1002002009 to 362 3/8"1 5/16"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Oxygen±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553914A13000000
    0 to 3006006009 to 362 3/8"1 5/16"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Oxygen±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553914A14000000
    0 to 5001,0001,0009 to 362 3/8"1 5/16"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Oxygen±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553914A15000000
    0 to 1,0002,0002,0009 to 362 3/8"1 5/16"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Oxygen±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553914A16000000
    0 to 1,5003,0003,0009 to 362 3/8"1 5/16"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Oxygen±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553914A17000000
     

    Clean Room Pressure-Regulating Valves for Water, Air, and Inert Gas

    Image of Product. Front orientation. Pressure-Regulating Valves. Clean Room Pressure-Regulating Valves for Water, Air, and Inert Gas.
    To maintain contaminant-free standards in clean room environments, these valves come cleaned and bagged to Fed. Std. Class 100 and ISO Class 5 clean room standards and have a 316 stainless steel body with a smooth finish to resist dust collection. They automatically reduce a high, variable inlet pressure to a lower, stable output pressure. Adjust the outlet pressure within the range. Valves are no-bleed style, so they keep process media contained within the valve.
    Inlet
    Outlet
    Thread
    Size
    Location
    Max. Pressure,
    psi
    Thread
    Size
    Location
    Pressure Range,
    psi
    Pressure Adjustment
    Method
    Pressure Gauge
    Included
    End-to-End
    Lg.
    Panel Cutout
    Dia.
    Clean Room Std.
    For Use With
    Temp. Range,
    ° F
    Each
    Metric Female
     
    316 Stainless Steel Body—Fluoroelastomer Diaphragm and 316 Stainless Steel Seal
    M5 × 0.8 mmSide150M5 × 0.8 mmSide1.4 to 28KnobNo1 3/16"1 1/4"Fed. Std. Class 100, ISO Class 5
    Deionized Water, Air, Nitrogen, Oxygen41 to 1404390T1110000000
    M5 × 0.8 mmSide150M5 × 0.8 mmSide7 to 99KnobNo1 3/16"1 1/4"Fed. Std. Class 100, ISO Class 5
    Deionized Water, Air, Nitrogen, Oxygen41 to 1404390T112000000
     

    Cleaned and Bagged Pressure-Regulating Valves for Air and Inert Gas

    Image of Product. Front orientation. Pressure-Regulating Valves. Cleaned and Bagged Pressure-Regulating Valves for Air and Inert Gas.
    Often used for oxygen service and other high-purity applications, these valves are cleaned and bagged to meet CGA G-4.1 standards to prevent contamination. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have two gauge ports. They are no-bleed style, so they keep process gases contained in the valve.
    Inlet
    Outlet
    Gauge Port
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    Pressure Gauge
    Included
    Pipe
    Size
    Location
    Connection
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Specs.
    Met
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Brass Body—Buna-N Diaphragm and Fluoroelastomer Seal
    1/2
    Side5001/2
    SideT-HandleNo1/4
    SideNPT Female2 13/16"Nitrogen, Oxygen, Argon, Helium, Neon-40 to 165CGA G-4.15 to 55, 40 to 110, 100 to 200, 175 to 30049305K210000000
    3/4
    Side5003/4
    SideT-HandleNo1/4
    SideNPT Female3 5/16"Nitrogen, Oxygen, Argon, Helium, Neon-40 to 165CGA G-4.15 to 55, 40 to 110, 100 to 200, 175 to 27549305K22000000
    1
    Side5001
    SideT-HandleNo1/4
    SideNPT Female3 5/16"Nitrogen, Oxygen, Argon, Helium, Neon-40 to 165CGA G-4.15 to 55, 40 to 110, 100 to 200, 175 to 27549305K23000000
     

    Tank-Mount Pressure-Regulating Valves for Air and Inert Gas

    These valves automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    Single Stage
    Image of Product. UNF Male Outlet × Female Inlet Single-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Single Stage, Female Inlet, UNF Outlet Thread, Male Outlet, Outlet-Pressure-Adjustment T-Handle.
    Image of Product. UNF Male Outlet × Female Inlet Single-Stage Valves with Knob. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Single Stage, Female Inlet, UNF Outlet Thread, Male Outlet, Outlet-Pressure-Adjustment Knob.

    UNF Male Outlet × Female

    Inlet Single-Stage

    Valves with T-Handle

    UNF Male Outlet ×

    Female Inlet

    Single-Stage Valves

    with Knob

    Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
    Brass Body—Valves with a brass body have a longer service life than valves with a brass and steel body.
    Stainless Steel Diaphragm—Valves with a stainless steel diaphragm can withstand harsh environments.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Body
    Seal
    Diaphragm
    Temp. Range,
    ° F
    Each
    For Oxygen
     
    9/16"-18 UNF Male Outlet × NGO Female Inlet
    540
    SideRight Hand
    0 to 4,000SideLeft Hand
    0 to 50KnobBrassPTFENeoprene-20 to 1203687N1110000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 50T-HandleBrassPTFEStainless Steel-20 to 1203687N116000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrassPTFERubber-20 to 1207897A31000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrassPTFEStainless Steel-20 to 1207897A51000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 145KnobBrass/SteelPTFERubber-20 to 1207897A61000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 200T-HandleBrassPTFERubber-20 to 1207897A1000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 200T-HandleBrassPTFEStainless Steel-20 to 1203687N118000000
     
    Two Stage
    Image of Product. NPT Female Outlet × Female Inlet Two-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Two Stage, NPT Outlet Thread, Female Outlet, Female Inlet, Outlet-Pressure-Adjustment T-Handle.
    Image of Product. UNF Male Outlet × Female Inlet Two-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Two Stage, Female Inlet, UNF Outlet Thread, Male Outlet, Outlet-Pressure-Adjustment T-Handle.

    NPT Female Outlet ×

    Female Inlet Two-Stage

    Valves with T-Handle

    UNF Male Outlet ×

    Female Inlet Two-Stage

    Valves with T-Handle

    Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
    Brass Body—Valves with a brass body have a longer service life than valves with a brass and steel body.
    Stainless Steel Diaphragm—Valves with a stainless steel diaphragm can withstand harsh environments.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Body
    Seal
    Diaphragm
    Temp. Range,
    ° F
    Each
    For Oxygen
     
    1/4 NPT Female Outlet × NGO Female Inlet
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 250T-HandleBrassPTFENeoprene-20 to 1203687N120000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 250T-HandleBrassPTFEStainless Steel-20 to 1207897A75000000
     
    9/16"-18 UNF Male Outlet × NGO Female Inlet
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 50T-HandleBrassPTFENeoprene-20 to 1203687N119000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 50T-HandleBrassPTFEStainless Steel-20 to 1203687N125000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrass/SteelPTFERubber-20 to 1207897A3000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrassPTFEStainless Steel-20 to 1207897A74000000
     

    Tank-Mount Pressure-Regulating Valves for Cryogenic Cylinders

    Image of Product. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Cryogenic Cylinders.
    Automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. These valves can remove gases from liquid cryogenic cylinders. They have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves come with a gauge to monitor outlet pressure. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    Inlet
    Outlet
    For Use
    With
    CGA
    No.
    Location
    Thread
    Direction
    No. of
    Stages
    Thread
    Size
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Temp. Range,
    ° F
    Each
    UNF Male Outlet × NGO Female Inlet
     
    Brass Body—Stainless Steel Diaphragm and PTFE Seal
    Oxygen540
    SideRight Hand
    Single9/16"-18
    BottomRight Hand
    0 to 125T-Handle-20 to 1207897A840000000
     

    Tank-Mount High-Pressure-Regulating Valves for Air and Inert Gas

    Often used for pressure-vessel testing and other high-pressure applications, these valves can handle at least seven times the outlet pressure of standard tank-mount pressure-regulating valves. They automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    For Oxygen
    Image of Product. Female Outlet × Female Inlet Straight With Knob. Front orientation. Pressure-Regulating Valves. Tank-Mount High-Pressure-Regulating Valves for Air and Inert Gas, Female Inlet, Female Outlet, Single Stage, Outlet-Pressure-Adjustment Knob.

    Female Outlet × Female

    Inlet Straight With Knob

    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    For Tube
    OD
    Location
    Pressure Range,
    psi
    Pressure Adjustment
    Method
    Shape
    Body
    Seal
    Diaphragm
    Temp. Range,
    ° F
    Each
    NGO Female Inlet × Swagelok® Female Outlet
    540
    SideRight Hand
    0 to 4,000Single1/4"Side0 to 1,500KnobStraightBrassPCTFENeoprene-20 to 1206677A170000000
    540
    SideRight Hand
    0 to 4,000Single1/4"Side0 to 2,500KnobStraightBrassPCTFENeoprene-20 to 1206677A18000000
     
    back to top