Find a gauge with the right connection material and dial type—many with traceable calibration certificates.
Vibration-Resistant Pressure Gauges
304 Stainless Steel Case with Brass Connection—Dual Scale (Pounds per Square Inch, Bar)
Temp. Range, ° F | Bottom Connection | Center-Back Connection | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Pipe Size | Environment | Process | Liquid Type | For Use With | Accuracy | Pressure Range | Each | Each | ||||
Upright Mount | |||||||||||||
BSPP Male | |||||||||||||
| 2 1/2" | 1/4 | 0 to 140 | 0 to 140 | Glycerin | Air Carbon Dioxide Hydraulic Fluid Natural Gas Water | ±1.5% Full Scale (Not Rated) | 0 to 5,800 psi/0 to 400 bar | 3548K11 | 000000 | 3548K21 | 000000 | ||
Pressure Test Fittings
Plugs | Gauge Adapters | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Size | Max. Pressure, psi | Gasket Material | Ht. | For Use With | Each | Each | ||||
NPT Male × Metric Male Plug | |||||||||||
Steel | |||||||||||
| 1/8 | M16 × 2 mm | 5,800 | Fluoroelastomer | 1 1/2" | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Water | 3194K55 | 000000 | 3194K59 | 000000 | ||
| 1/4 | M16 × 2 mm | 5,800 | Fluoroelastomer | 1 1/2" | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Water | 3194K56 | 00000 | 3194K59 | 00000 | ||
Pressure Transmitters with Digital Display
4-Pole M12 Plug Connection
Pressure, psi | Configurable Analog Transmitter/Digital Switch Output | Configurable Digital Switch Output | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range | Set Point Range | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Ht. | Wd. | No. of | Analog Signal | Digital Signal | No. of | Digital Signal | Enclosure Rating | Certification | For Use With | Accuracy | Housing Material | Connection Material | Temp. Range, ° F | Each | |||
1/4 NPT Male Pipe Connection | |||||||||||||||||||||
18V DC to 30V DC Input Voltage | |||||||||||||||||||||
| 0 to 3,625 | 0 to 3,625 | 3,625 | 5,800 | 3 3/4" | 1 11/32" | 1 | 4 mA to 20 mA, 0V DC to 10V DC | NPN PNP | 1 | NPN PNP | IP67 | UL Listed, C-UL Listed, CE Marked | Air Argon Hydraulic Fluid Nitrogen Water | ±0.5% | 304 Stainless Steel | 304 Stainless Steel | -40 to 185 | 3160T187 | 0000000 | ||
| 0 to 5,800 | 0 to 5,800 | 5,800 | 9,425 | 3 3/4" | 1 11/32" | 1 | 4 mA to 20 mA, 0V DC to 10V DC | NPN PNP | 1 | NPN PNP | IP67 | UL Listed, C-UL Listed, CE Marked | Air Argon Hydraulic Fluid Nitrogen Water | ±0.5% | 304 Stainless Steel | 304 Stainless Steel | -40 to 185 | 3160T188 | 000000 | ||
Flush-Mount Pressure Transmitters
4 mA to 20 mA Output Signal—2-Pole M12 Plug Connection
Pressure Range, psi | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Input Voltage, V DC | Ht. | Wd. | Enclosure Rating | Certification | For Use With | Accuracy | Housing Material | Connection Material | Diaphragm Material | Temp. Range, ° F | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1/4 BSPP Male Pipe Connection | |||||||||||||||||
| 0 to 2,320 | 5,800 | 5,800 | 8.5 to 36 | 1 1/2" | 3/4" | IP67, IP69K | CE Marked | Air Argon Diesel Fuel Hydraulic Fluid Nitrogen Water | ±0.05% | 316 Stainless Steel | 316 Stainless Steel | Fluoroelastomer | -10 to 190 | 5465N13 | 0000000 | ||
| 0 to 5,800 | 11,580 | 11,580 | 8.5 to 36 | 1 1/2" | 3/4" | IP67, IP69K | CE Marked | Air Argon Diesel Fuel Hydraulic Fluid Nitrogen Water | ±0.05% | 316 Stainless Steel | 316 Stainless Steel | Fluoroelastomer | -10 to 190 | 5465N15 | 000000 | ||
Hazardous Location Easy-Setup Differential Pressure Transmitters
Mounting Holes | Connection | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure Differential | Max. Input Pressure, psi | Input Voltage, V DC | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Control Communication Protocol | Enclosure Rating | For Use With | Accuracy | Pipe | Fitting | Material | Temp. Range, ° F | Each | |||
4 to 20 mA Output Signal—Screw Terminals | ||||||||||||||||||||
NEC Class I Divisions 1, 2 Groups A, B, C, D | ||||||||||||||||||||
| 0 in. H₂O to 200 in. H₂O | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | -40 to 185 | 8876N22 | 000000000 | ||
| 0 in. H₂O to 1,000 in. H₂O | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | -40 to 185 | 8876N13 | 00000000 | ||
| 0 psi to 150 psi | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | -40 to 185 | 8876N14 | 00000000 | ||
| 0 psi to 450 psi | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | -40 to 185 | 8876N15 | 00000000 | ||
| 0 psi to 1,500 psi | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | -40 to 185 | 8876N16 | 00000000 | ||
Easy-Setup Differential Pressure Transmitters
Mounting Holes | Connection | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure Differential | Max. Input Pressure, psi | Input Voltage, V DC | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Control Communication Protocol | Enclosure Rating | For Use With | Accuracy | Pipe | Fitting | Material | Housing Material | Temp. Range, ° F | Each | |||
4 to 20 mA Output Signal—Screw Terminals | |||||||||||||||||||||
| 0 in. H₂O to 200 in. H₂O | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | Aluminum | -40 to 185 | 3260N14 | 000000000 | ||
| 0 in. H₂O to 1,000 in. H₂O | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | Aluminum | -40 to 185 | 3260N15 | 00000000 | ||
| 0 psi to 150 psi | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | Aluminum | -40 to 185 | 3260N11 | 00000000 | ||
| 0 psi to 450 psi | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | Aluminum | -40 to 185 | 3260N12 | 00000000 | ||
| 0 psi to 1,500 psi | 5,800 | 11 to 55 | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | Air, Hydraulic Fluid, Water | ±0.075% | NPT Female | Threaded | Hastelloy Nickel | Aluminum | -40 to 185 | 3260N16 | 00000000 | ||