    122 Products
    About Pressure Gauges
    industrial info icon

    Find a gauge with the right connection material and dial type—many with traceable calibration certificates.

    Digital-Display High-Accuracy Pressure Gauges

    A four-digit LCD display allows for easy reading of measurements. The LCD shuts off automatically to extend battery life. Gauges are commonly used with pneumatic regulators, compressors, and in critical processes that require high accuracy, such as hydraulic and laboratory applications.
    ABS Case with Brass Connection—(Pounds per Square Inch, Bar, Kilograms per Square Centimeter, Megapascals)
    Image of Product. Front orientation. Center-Back Connection. Digital-Display High-Accuracy Pressure Gauges, ABS Case.
    Image of Attribute. Center-Back Connection. Front orientation. Digital-Display High-Accuracy Pressure Gauges, Center-Back Connection.

    Center-Back

    Connection

    Temp.
    Range, ° F
    Batteries
    Center-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Case
    Color
    Environment
    Process
    Included
    Size
    Features
    For Use With
    Accuracy
    Pressure Range
    Each
    Any-Angle Mount
     
    NPT Male
    1 3/4"1/8
    Black-10 to 140-10 to 140YesCR24505-min. Automatic Shut-OffAir
    Carbon Dioxide
    Hydrogen
    Natural Gas
    Nitrogen
    ±1% Full Scale (Grade 1A)0 to 145 psi/0 to 10 bar/0 to 10 kg per cm²/0 to 1 MPa1287N1000000
    1 3/4"1/4
    Black-10 to 140-10 to 140YesCR24505-min. Automatic Shut-OffAir
    Carbon Dioxide
    Hydrogen
    Natural Gas
    Nitrogen
    ±1% Full Scale (Grade 1A)0 to 145 psi/0 to 10 bar/0 to 10 kg per cm²/0 to 1 MPa1287N200000
     
    NPT Male with Calibration Certificate Traceable to NIST
    1 3/4"1/8
    Black-10 to 140-10 to 140YesCR24505-min. Automatic Shut-OffAir
    Carbon Dioxide
    Hydrogen
    Natural Gas
    Nitrogen
    ±1% Full Scale (Grade 1A)0 to 145 psi/0 to 10 bar/0 to 10 kg per cm²/0 to 1 MPa1287N311000000
    1 3/4"1/4
    Black-10 to 140-10 to 140YesCR24505-min. Automatic Shut-OffAir
    Carbon Dioxide
    Hydrogen
    Natural Gas
    Nitrogen
    ±1% Full Scale (Grade 1A)0 to 145 psi/0 to 10 bar/0 to 10 kg per cm²/0 to 1 MPa1287N312000000
     
    ABS Case with 304 Stainless Steel Connection—(Pounds per Square Inch, Bar, Megapascals)
    Image of Product. Front orientation. Bottom Connection. Digital-Display High-Accuracy Pressure Gauges, ABS Case.
    Image of Attribute. Bottom Connection. Front orientation. Digital-Display High-Accuracy Pressure Gauges, Bottom Connection.

    Bottom

    Connection

    Temp.
    Range, ° F
    Batteries
    Bottom
    Connection
    Dial
    Dia.
    Pipe
    Size
    Case
    Color
    Environment
    Process
    Included
    Size
    Features
    For Use With
    Accuracy
    Choose a Pressure Range
    Each
    Any-Angle Mount
     
    NPT Male
    2 1/2"1/4
    Black0 to 18515 to 140Yes9V3-min. Automatic Shut-Off
    Maximum Reading Recall
    Air
    Hydrogen
    Nitrogen
    ±1% Full Scale (Not Rated)0 to 30 psi/0 to 2 bar/0 to 0.2 Mpa, 0 to 100 psi/0 to 6.9 bar/0 to 0.7 MPa, 0 to 300 psi/0 to 20.7 bar/0 to 2 MPa2798K211000000
     
    NPT Male with Calibration Certificate Traceable to NIST
    2 1/2"1/4
    Black0 to 18515 to 140Yes9V3-min. Automatic Shut-Off
    Maximum Reading Recall
    Air
    Hydrogen
    Nitrogen
    ±1% Full Scale (Not Rated)0 to 30 psi/0 to 2 bar/0 to 0.2 Mpa, 0 to 100 psi/0 to 6.9 bar/0 to 0.7 MPa, 0 to 300 psi/0 to 20.7 bar/0 to 2 MPa2798K311000000
     
    ABS Case with 316 Stainless Steel Connection—(Pounds per Square Inch, Bar, Megapascals)
    Image of Product. Front orientation. Bottom Connection. Digital-Display High-Accuracy Pressure Gauges, ABS Case.
    Image of Attribute. Bottom Connection. Front orientation. Digital-Display High-Accuracy Pressure Gauges, Bottom Connection.

    Bottom

    Connection

    Temp.
    Range, ° F
    Batteries
    Bottom
    Connection
    Dial
    Dia.
    Pipe
    Size
    Case
    Color
    Environment
    Process
    Included
    Size
    Features
    For Use With
    Accuracy
    Choose a Pressure Range
    Each
    Any-Angle Mount
     
    NPT Male
    2 1/2"1/4
    Black0 to 18515 to 140Yes9V3-min. Automatic Shut-Off
    Maximum Reading Recall
    Air
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Natural Gas
    Water
    ±1% Full Scale (Not Rated)0 to 5 psi/0 to 0.34 bar/0 to 0.03 Mpa, 0 to 30 psi/0 to 2 bar/0 to 0.2 Mpa, 0 to 100 psi/0 to 6.9 bar/0 to 0.7 MPa, 0 to 200 psi/0 to 13.8 bar/0 to 1.3 MPa, 0 to 500 psi/0 to 34.4 bar/0 to 3.4 MPa, 0 to 1,000 psi/0 to 68.9 bar/0 to 6.8 MPa, 0 to 3,000 psi/0 to 206 bar/0 to 20.6 MPa, 0 to 5,000 psi/0 to 344 bar/0 to 34.4 MPa3834K1110000000
     
    NPT Male with Calibration Certificate Traceable to NIST
    2 1/2"1/4
    Black0 to 18515 to 140Yes9V3-min. Automatic Shut-Off
    Maximum Reading Recall
    Air
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Natural Gas
    Water
    ±1% Full Scale (Not Rated)0 to 5 psi/0 to 0.34 bar/0 to 0.03 Mpa, 0 to 30 psi/0 to 2 bar/0 to 0.2 Mpa, 0 to 100 psi/0 to 6.9 bar/0 to 0.7 MPa, 0 to 200 psi/0 to 13.8 bar/0 to 1.3 MPa, 0 to 500 psi/0 to 34.4 bar/0 to 3.4 MPa, 0 to 1,000 psi/0 to 68.9 bar/0 to 6.8 MPa, 0 to 3,000 psi/0 to 206 bar/0 to 20.6 MPa, 0 to 5,000 psi/0 to 344 bar/0 to 34.4 MPa3834K311000000
     

    Ultra-High-Accuracy Digital Pressure Test Gauges

    With an accuracy of ±0.05%, these have the highest accuracy of all our test gauges. Use them for testing, calibrating, laboratory applications, and other critical processes that require precision. They have a five-digit LCD display that allows for easy reading of measurements.
    304 Stainless Steel Case with 316 Stainless Steel Connection—Battery Powered
    Image of Product. Front orientation. Pressure Test Gauges. Ultra-High-Accuracy Digital Pressure Test Gauges.
    Image of Specification. Front orientation. Bottom Connection. Ultra-High-Accuracy Digital Pressure Test Gauges.
    Bottom
    Connection
    Pressure
    Pressure Resolution,
    psi
    Accuracy
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Enclosure
    Rating
    Hazardous Location Rating
    Features
    Digit
    Ht.
    For Use With
    Batteries
    Included
    Each
    NPT Male—Calibration Certificate Traceable to NIST
     
    3" Diameter Dial—1/4 Pipe Size
    0 psi to 10 psi
    0 in. H₂O to 270 in. H₂O
    0 kPa to 65 kPa
    0 MPa to 0.06 MPa
    0 bar to 0.6 bar
    0 kg/cm² to 0.7 kg/cm²
    0.001±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K11000000000
    0 psi to 15 psi
    0 in. H₂O to 410 in. H₂O
    0 kPa to 100 kPa
    0 MPa to 0.1 MPa
    0 bar to 1 bar
    0 kg/cm² to 1 kg/cm²
    0.001±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K1200000000
    0 psi to 30 psi
    0 in. H₂O to 830 in. H₂O
    0 kPa to 200 kPa
    0 MPa to 0.2 MPa
    0 bar to 2 bar
    0 kg/cm² to 2 kg/cm²
    0.001±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K1300000000
    0 psi to 60 psi
    0 in. H₂O to 1,600 in. H₂O
    0 kPa to 410 kPa
    0 MPa to 0.4 MPa
    0 bar to 4 bar
    0 kg/cm² to 4 kg/cm²
    0.001±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K1400000000
    0 psi to 100 psi
    0 in. H₂O to 2,700 in. H₂O
    0 kPa to 680 kPa
    0 MPa to 0.6 MPa
    0 bar to 6 bar
    0 kg/cm² to 7 kg/cm²
    0.01±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K1500000000
    0 psi to 160 psi
    0 in. H₂O to 4,400 in. H₂O
    0 kPa to 1,100 kPa
    0 MPa to 1.1 MPa
    0 bar to 11 bar
    0 kg/cm² to 11 kg/cm²
    0.01±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K1600000000
    0 psi to 200 psi
    0 in. H₂O to 5,500 in. H₂O
    0 kPa to 1,300 kPa
    0 MPa to 1.3 MPa
    0 bar to 13 bar
    0 kg/cm² to 14 kg/cm²
    0.01±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K1700000000
    0 psi to 300 psi
    0 in. H₂O to 8,300 in. H₂O
    0 kPa to 2,000 kPa
    0 MPa to 2 MPa
    0 bar to 20 bar
    0 kg/cm² to 20 kg/cm²
    0.01±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K1800000000
    0 psi to 600 psi
    0 in. H₂O to 16,600 in. H₂O
    0 kPa to 4,100 kPa
    0 MPa to 4 MPa
    0 bar to 40 bar
    0 kg/cm² to 40 kg/cm²
    0.01±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K1900000000
    0 psi to 800 psi
    0 in. H₂O to 22,100 in. H₂O
    0 kPa to 5,500 kPa
    0 MPa to 5 MPa
    0 bar to 55 bar
    0 kg/cm² to 55 kg/cm²
    0.01±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K2100000000
    0 psi to 1,000 psi
    0 in. H₂O to 27,700 in. H₂O
    0 kPa to 6,800 kPa
    0 MPa to 6 MPa
    0 bar to 65 bar
    0 kg/cm² to 70 kg/cm²
    0.1±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K2200000000
    0 psi to 2,000 psi
    0 in. H₂O to 55,400 in. H₂O
    0 kPa to 13,700 kPa
    0 MPa to 13 MPa
    0 bar to 135 bar
    0 kg/cm² to 140 kg/cm²
    0.1±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K2400000000
    0 psi to 3,000 psi
    0 in. H₂O to 83,100 in. H₂O
    0 kPa to 20,600 kPa
    0 MPa to 20 MPa
    0 bar to 205 bar
    0 kg/cm² to 210 kg/cm²
    0.1±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K2500000000
    0 psi to 5,000 psi
    0 kPa to 34,400 kPa
    0 MPa to 30 MPa
    0 bar to 340 bar
    0 kg/cm² to 350 kg/cm²
    0.1±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K2600000000
     

    Pressure Transmitters with Digital Display

    Read pressure directly at the source and send data remotely with one device. Also known as transducers, these transmitters convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated pressure range.
    To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You need an IO-Link controller (not included) to connect to your interface.
    All have an M12 plug to connect to M12 sockets. When using the analog output current they require two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. These transmitters can also connect using three wires to send an analog output voltage—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply. View switch wiring diagrams by selecting a part number and clicking Product Detail.
    All transmitters are rated IP67 for protection from temporary submersion. UL and C-UL listed as well as CE marked, they meet strict American, Canadian, and European safety standards.
    4-Pole M12 Plug Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters with Digital Display.
    Pressure,
    psi
    Configurable Analog
    Transmitter/Digital Switch Output
    Configurable
    Digital Switch Output
    Range
    Set Point
    Range
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Ht.
    Wd.
    No.
    of
    Analog Signal
    Digital
    Signal
    No.
    of
    Digital
    Signal
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
    1/4 NPT Male Pipe Connection
     
    18V DC to 30V DC Input Voltage
    0 to 290 to 2929553 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T1810000000
    0 to 730 to 73731453 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T182000000
    0 to 1450 to 1451452903 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T183000000
    0 to 2900 to 2902905803 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T184000000
    0 to 7250 to 7257251,4503 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T185000000
    0 to 1,4500 to 1,4501,4502,9003 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T186000000
    0 to 3,6250 to 3,6253,6255,8003 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T187000000
    0 to 5,8000 to 5,8005,8009,4253 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T188000000
    0 to 8,7000 to 8,7008,70014,5003 3/4"1 11/32"14 mA to 20 mA, 0V DC to 10V DCNPN
    PNP
    1NPN
    PNP
    IP67
    UL Listed, C-UL Listed, CE Marked
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.5%304 Stainless Steel
    304 Stainless Steel-40 to 1853160T189000000
     

    High-Accuracy Digital Pressure Test Gauges

    Not only do these gauges have an accuracy of ±0.25%, they also have a four-digit LCD display that allows for easy reading of measurements. Use them for testing, calibrating, laboratory applications, and other critical applications that require precision.
    Aluminum Case with 316 Stainless Steel Connection—Battery Powered
    Image of Product. Front orientation. Pressure Test Gauges. High-Accuracy Digital Pressure Test Gauges, Battery Powered.
    Image of Specification. Front orientation. Bottom Connection. High-Accuracy Digital Pressure Test Gauges.

    Bottom

    Connection

    Dial
    Bottom
    Connection
    Pressure
    Pressure Resolution,
    psi
    Accuracy
    Digit
    Ht.
    Ht.
    Wd.
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Enclosure
    Rating
    Hazardous Location Rating
    For Use With
    Features
    Batteries
    Included
    Each
    NPT Male
     
    1/4 Pipe Size
    0 psi to 3 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K1110000000
    0 psi to 3 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K311000000
    0 psi to 5 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K112000000
    0 psi to 5 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K312000000
    0 psi to 15 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K114000000
    0 psi to 15 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K313000000
    0 psi to 30 psi
    0 MPa to 1.4 MPa
    0 bar to 2 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K116000000
    0 psi to 30 psi
    0 MPa to 1.4 MPa
    0 bar to 2 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K314000000
    0 psi to 100 psi
    0 MPa to 1.4 MPa
    0 bar to 7 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K118000000
    0 psi to 100 psi
    0 MPa to 1.4 MPa
    0 bar to 7 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K315000000
    0 psi to 199.9 psi
    0 MPa to 1.4 MPa
    0 bar to 14 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K119000000
    0 psi to 199.9 psi
    0 MPa to 1.4 MPa
    0 bar to 14 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K316000000
    0 psi to 300 psi
    0 MPa to 2 MPa
    0 bar to 20 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K121000000
    0 psi to 300 psi
    0 MPa to 2 MPa
    0 bar to 20 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K317000000
    0 psi to 500 psi
    0 MPa to 3.5 MPa
    0 bar to 35 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K122000000
    0 psi to 500 psi
    0 MPa to 3.5 MPa
    0 bar to 35 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K318000000
    0 psi to 1,000 psi
    0 MPa to 7 MPa
    0 bar to 70 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K123000000
    0 psi to 1,000 psi
    0 MPa to 7 MPa
    0 bar to 70 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K319000000
    0 psi to 3,000 psi
    0 MPa to 20 MPa
    0 bar to 200 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K131000000
    0 psi to 3,000 psi
    0 MPa to 20 MPa
    0 bar to 200 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K321000000
    0 psi to 5,000 psi
    0 MPa to 35 MPa
    0 bar to 350 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K132000000
    0 psi to 5,000 psi
    0 MPa to 35 MPa
    0 bar to 350 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K322000000
     
    NPT Male—Calibration Certificate Traceable to NIST
     
    1/4 Pipe Size
    0 psi to 3 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K211000000
    0 psi to 3 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K331000000
    0 psi to 5 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K212000000
    0 psi to 5 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K332000000
    0 psi to 15 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K213000000
    0 psi to 15 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K333000000
    0 psi to 30 psi
    0 MPa to 1.4 MPa
    0 bar to 2 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K214000000
    0 psi to 30 psi
    0 MPa to 1.4 MPa
    0 bar to 2 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K334000000
    0 psi to 100 psi
    0 MPa to 1.4 MPa
    0 bar to 7 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K215000000
    0 psi to 100 psi
    0 MPa to 1.4 MPa
    0 bar to 7 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K335000000
    0 psi to 199.9 psi
    0 MPa to 1.4 MPa
    0 bar to 14 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K216000000
    0 psi to 199.9 psi
    0 MPa to 1.4 MPa
    0 bar to 14 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K336000000
    0 psi to 300 psi
    0 MPa to 2 MPa
    0 bar to 20 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K217000000
    0 psi to 300 psi
    0 MPa to 2 MPa
    0 bar to 20 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K337000000
    0 psi to 500 psi
    0 MPa to 3.5 MPa
    0 bar to 35 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K218000000
    0 psi to 500 psi
    0 MPa to 3.5 MPa
    0 bar to 35 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K338000000
    0 psi to 1,000 psi
    0 MPa to 7 MPa
    0 bar to 70 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K219000000
    0 psi to 1,000 psi
    0 MPa to 7 MPa
    0 bar to 70 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K339000000
    0 psi to 3,000 psi
    0 MPa to 20 MPa
    0 bar to 200 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K221000000
    0 psi to 3,000 psi
    0 MPa to 20 MPa
    0 bar to 200 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K341000000
    0 psi to 5,000 psi
    0 MPa to 35 MPa
    0 bar to 350 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, Water5-min. Automatic Shut-OffYes3943K222000000
    0 psi to 5,000 psi
    0 MPa to 35 MPa
    0 bar to 350 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Ex Ia IIC T4-T3; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 0 Groups IIC, IIB, IIAAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water5-min. Automatic Shut-OffYes3943K342000000
     
    Aluminum Case with 316 Stainless Steel Connection—Electric 8-24V AC, 9-32V DC
    Image of Product. Front orientation. Pressure Test Gauges. High-Accuracy Digital Pressure Test Gauges, Electric.
    Image of Specification. Front orientation. Bottom Connection. High-Accuracy Digital Pressure Test Gauges.

    Bottom

    Connection

    Dial
    Bottom
    Connection
    Pressure
    Pressure Resolution,
    psi
    Accuracy
    Digit
    Ht.
    Ht.
    Wd.
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Enclosure
    Rating
    For Use With
    Wire
    Connection
    Each
    NPT Male
     
    1/4 Pipe Size
    0 psi to 3 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K1410000000
    0 psi to 5 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K142000000
    0 psi to 15 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K144000000
    0 psi to 30 psi
    0 MPa to 1.4 MPa
    0 bar to 2 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K146000000
    0 psi to 100 psi
    0 MPa to 1.4 MPa
    0 bar to 7 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K148000000
    0 psi to 199.9 psi
    0 MPa to 1.4 MPa
    0 bar to 14 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K149000000
    0 psi to 300 psi
    0 MPa to 2 MPa
    0 bar to 20 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K151000000
    0 psi to 500 psi
    0 MPa to 3.5 MPa
    0 bar to 35 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K152000000
    0 psi to 1,000 psi
    0 MPa to 7 MPa
    0 bar to 70 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K153000000
    0 psi to 3,000 psi
    0 MPa to 20 MPa
    0 bar to 200 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K161000000
    0 psi to 5,000 psi
    0 MPa to 35 MPa
    0 bar to 350 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K162000000
     
    NPT Male—Calibration Certificate Traceable to NIST
     
    1/4 Pipe Size
    0 psi to 3 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K231000000
    0 psi to 5 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.001±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K232000000
    0 psi to 15 psi
    0 MPa to 1.4 MPa
    0 bar to 1 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K233000000
    0 psi to 30 psi
    0 MPa to 1.4 MPa
    0 bar to 2 bar
    0.01±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K234000000
    0 psi to 100 psi
    0 MPa to 1.4 MPa
    0 bar to 7 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K235000000
    0 psi to 199.9 psi
    0 MPa to 1.4 MPa
    0 bar to 14 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K236000000
    0 psi to 300 psi
    0 MPa to 2 MPa
    0 bar to 20 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K237000000
    0 psi to 500 psi
    0 MPa to 3.5 MPa
    0 bar to 35 bar
    0.1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K238000000
    0 psi to 1,000 psi
    0 MPa to 7 MPa
    0 bar to 70 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K239000000
    0 psi to 3,000 psi
    0 MPa to 20 MPa
    0 bar to 200 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K241000000
    0 psi to 5,000 psi
    0 MPa to 35 MPa
    0 bar to 350 bar
    1±0.25% Full Scale
    (Not Rated)
    1/2"2 7/8"3 3/8"0 to 185-40 to 200NEMA 2
    Air, Hydraulic Fluid, WaterWire Leads3943K242000000
     

    Pressure Transmitters for Compressed Air

    Image of Product. Front orientation. Pressure Transmitters. Pressure Transmitters for Compressed Air.
    With a pressure range common to most compressed air systems, use these transmitters to monitor your system's air pressure. Also known as transducers, these transmitters convert pressure to an electrical signal that can be interpreted by receiving devices such as remote displays and motor speed controls. They can also connect to a programmable logic controller (PLC) with two digital PNP switch outputs, so you can activate automated controls or alarms when a set pressure is reached. They have a digital display with buttons to change settings.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
    Transmitters with Wire Lead Connection
    2.4 mA to 20 mA Output Signal—Transmitters with output current connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    0.6V DC to 5V DC Output Signal—Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Analog
    Transmitter Output
    Digital
    Switch Output
    Pressure,
    psi
    Analog Signal
    No.
    of
    Digital
    Signal
    No.
    of
    Range
    Set Point
    Range
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing
    Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/8 NPT Male Pipe Connection
    2.4 mA to 20 mA1PNP214.5 to 14514.5 to 14514521812 to 241 3/16"1 3/16"IP40
    UL Recognized Component, C-UL Recognized Component, CE Marked, CSA Certified
    Air
    Argon
    Nitrogen
    ±0.2%PolybutyleneNickel-Plated Brass25 to 1204276N13000000
    0.6V DC to 5V DC1PNP214.5 to 14514.5 to 14514521812 to 241 3/16"1 3/16"IP40
    UL Recognized Component, C-UL Recognized Component, CE Marked, CSA Certified
    Air
    Argon
    Nitrogen
    ±0.2%PolybutyleneNickel-Plated Brass25 to 1204276N1100000
     
    1/4" OD Push-to-Connect Tube Connection
    2.4 mA to 20 mA1PNP214.5 to 14514.5 to 14514521812 to 241 3/16"1 3/16"IP40
    UL Recognized Component, C-UL Recognized Component, CE Marked, CSA Certified
    Air
    Argon
    Nitrogen
    ±0.2%PolybutyleneNickel-Plated Brass25 to 1204276N1400000
    0.6V DC to 5V DC1PNP214.5 to 14514.5 to 14514521812 to 241 3/16"1 3/16"IP40
    UL Recognized Component, C-UL Recognized Component, CE Marked, CSA Certified
    Air
    Argon
    Nitrogen
    ±0.2%PolybutyleneNickel-Plated Brass25 to 1204276N1200000
     
    Square Panel-Mount Brackets

    Pressure and Vacuum Transmitters for Compressed Air

    Image of Product. Front orientation. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters for Compressed Air.
    Specifically made for compressed air and gas systems, these transmitters remotely monitor pressure and vacuum. Also known as transducers, they convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set pressure or vacuum is reached. Change settings with the buttons on the digital display.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
    UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
    Wire Leads
    4 mA to 20 mA Output Signal—Transmitters with 4 to 20 mA output signal connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Signal is not lost over long distances and isn’t affected by electrical interference from other devices.
    1V DC to 5V DC Output Signal—Transmitters with 1 to 5V DC output signal connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Analog
    Transmitter Output
    Digital
    Switch Output
    Max.
    Pressure, psi
    Setpoint
    Range
    Analog Signal
    No.
    Of
    Digital
    Signal
    No.
    of
    Pressure Range,
    psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Pressure,
    psi
    Vacuum,
    in. Hg
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Connection
    Material
    Temp. Range,
    ° F
    Each
    Polybutylene Housing
     
    1/8 Male NPT Pipe Threaded Fitting Connection
    4 mA to 20 mA1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±2%Nickel-Plated Brass25 to 1204263N13000000
    1V DC to 5V DC1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±2%Nickel-Plated Brass25 to 1204263N1100000
     
    1/4" OD Tube Push-to-Connect Fitting Connection
    4 mA to 20 mA1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±2%Nickel-Plated Brass25 to 1204263N1400000
    1V DC to 5V DC1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±2%Nickel-Plated Brass25 to 1204263N1200000
     
    Square Panel-Mount Brackets

    Compressed Air Vacuum Transmitters

    Image of Product. Front orientation. Vacuum Transmitters. Compressed Air Vacuum Transmitters .
    Designed for compressed air and gas systems, these transmitters remotely monitor vacuum. Also known as transducers, they convert vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set vacuum is reached. Change settings and view readings on the digital display.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's vacuum range and output signal. As vacuum decreases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated vacuum range.
    1V DC to 5V DC Output Signal—Transmitters with 1 to 5V DC output signal connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    4 mA to 20 mA Output Signal—Transmitters with 4 to 20 mA output signal connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Signal is not lost over long distances and isn’t affected by electrical interference from other devices.
    Certification—UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
    Analog
    Transmitter Output
    Digital
    Switch Output
    Analog Signal
    No.
    of
    Digital
    Signal
    No.
    of
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Pressure Set
    Point, in. Hg
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Each
    Wire Lead Connection
     
    1/8 NPT Male Threaded Pipe Connection
    1V DC to 5V DC1PNP20 to 3015720 to 3012 to 241 3/16"1 3/16"IP40
    UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    3859N11000000
    4 mA to 20 mA1PNP20 to 3015720 to 3012 to 241 3/16"1 3/16"IP40
    UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    3859N1300000
     
    1/4" OD Push-to-Connect Tube Connection
    1V DC to 5V DC1PNP20 to 3015720 to 3012 to 241 3/16"1 3/16"IP40
    UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    3859N1200000
    4 mA to 20 mA1PNP20 to 3015720 to 3012 to 241 3/16"1 3/16"IP40
    UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    3859N1400000
     
    Square Panel-Mount Brackets

    Pressure and Vacuum Transmitters with Digital Display

    Monitor and control vacuum pumps, air compressors, and hydraulics while viewing readings and warnings on the display. These transmitters, also called transducers, have two outputs, so you can program them to work as a transmitter, a switch, or both. When they reach their setpoint, they send electrical signals to your programmable logic controller (PLC) to trigger actions in your system. Adjust their reset point anywhere within the setpoint range. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You need an IO-Link controller (not included) to connect to your interface.
    Buttons on the display let you change your setpoint, measuring range, and other settings. To quickly tell the status of your process, you can program the color of the display to red and green. LEDs on the corners also notify you of your output’s switching status. Rotate the head to view the display from the best angle.
    You must calibrate your PLC in order for it to interpret signals from these transmitters. As pressure increases, the output signal from the transmitter will increase. These transmitters only give accurate readings within the rated pressure or vacuum range.
    All have an M12 plug to connect to M12 Connectors. When using both switching outputs and an IO-Link controller, they require four wires to connect. For their 4-20mA analog output, they need two wires to connect. View switch wiring diagrams by selecting a part number and clicking Product Detail.
    To withstand wet environments, these transmitters have a 316L stainless steel connection and are IP rated. Their IP ratings also mean they’re dust tight and stand up to spraying water and brief submersion. UL and C-UL listed as well as CE marked, they meet strict American, Canadian, and European safety standards.
    4 mA to 20 mA Output Signal—4-Pole M12 Plug-In Connection
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters with Digital Display.
    Max.
    Pressure, psi
    Configurable Analog
    Transmitter/Digital Switch Output
    Configurable
    Digital Switch Output
    Pressure Range,
    psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Ht.
    Wd.
    No.
    Of
    Analog
    Signal
    Digital
    Signal
    No.
    Of
    Digital
    Signal
    Measurement Unit
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Polyester Plastic Housing
     
    1/4 NPT Female
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N150000000
    0 to 362.50 to 29.52,1752,17518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N16000000
     
    1/4 NPT Male
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N12000000
    0 to 3600 to 29.52,1752,17518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N13000000
     
    1/4 BSPP Female
    0 to 870 to 29.560060018 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N17000000
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N18000000
    0 to 3600 to 29.52,1752,17518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N19000000
     
    1/4 BSPP Male
    0 to 7.30 to 14.814514518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N27000000
    0 to 14.50 to 1.414514518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N28000000
    0 to 870 to 29.560060018 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N24000000
    0 to 1450 to 29.71,0851,08518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N25000000
    0 to 3600 to 29.514514518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N26000000
     
    back to top