    18 Products

    Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers.
    Circulate water or glycol solutions to prevent spot-welding systems, molds, lasers, and other temperature-sensitive equipment from overheating. These chillers provide constant, uniform temperatures. An internal tank ensures liquid flows in a continuous loop. Adjust the set temperature with the keypad.
    Bypass Valve—Chillers with a bypass valve recirculate liquid in the chiller if the outlet is obstructed.
    Cooling Capacity—Cooling capacity is based on a 65° F liquid temperature and a 95° F room temperature.
    Cannot Be Sold To—Liquid chillers cannot be sold to the listed areas due to chemical regulations.
    Overall
    Cooling Cap.,
    BTU/hr
    Current,
    amp
    Compressor
    Power, hp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Control
    Range, ° F
    Ht.
    Wd.
    Dp.
    Tank Cap.,
    gal.
    Refrigerant
    No.
    Features
    Cannot Be Sold To
    Each
    120V AC (Single Phase)
    2,100131/42 gpm @ 50 psi5050 to 8028 5/8"22"21 1/8"5R-513ABypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass0000000000000000
    4,30015.51/24 gpm @ 50 psi5050 to 8028 5/8"22"21 1/8"5R-513ABypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass000000000000000
     
    240V AC (Single Phase)
    11,3001714 gpm @ 50 psi5050 to 8033 3/8"31 1/8"25 1/8"10R-513ABypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass000000000000000
     
    240V AC (Three Phase)
    12,000111 1/24 gpm @ 50 psi5050 to 8033 3/8"31 1/8"25 1/8"10R-513ABypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass000000000000000
    24,00022210 gpm @ 35 psi3550 to 8035 7/8"34 1/8"31 5/8"10R-513ABypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass0000000000000000
     
    460V AC (Three Phase)
    24,00010310 gpm @ 35 psi3550 to 8035 5/8"33 1/8"31 5/8"10R-513ABypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass0000000000000000
    36,00011310 gpm @ 45 psi4550 to 8065"37"34 1/2"36R-407CBypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight GlassCalifornia, Canada0000000000000000
    54,00015515 gpm @ 45 psi4550 to 8065"37"34 1/2"36R-513ABypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass0000000000000000
    78,400261030 gpm @ 40 psi4050 to 8065 1/2"37"57"50R-513ABypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass00000000000000000
     

    Precision Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers. Precision Liquid Chillers, 120V AC (Single Phase).

    120V AC (Single

    Phase)

    Image of Product. Front orientation. Liquid Chillers. Precision Liquid Chillers, 240V AC (Single Phase).

    240V AC (Single

    Phase)

    Protect your most temperature-sensitive equipment from overheating. These chillers keep liquids within 0.18° F of the temperature you set. Far more advanced than basic chillers—which are accurate within a few full degrees—they’re even precise enough for use in medical imaging machines. Fill these chillers with distilled water or glycol solutions, and an internal pump moves the liquid out to your equipment and back in a continuous loop. They’re often used with spot-welding systems, molds, lasers, and X-ray diffraction equipment. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, alerts, and other information on the LED display.
    120V AC—120V AC chillers automatically replace their own filter, using a roller to swap in a fresh filter on a set schedule. Adjust the schedule to suit your application. A UV light system prevents algae and other bacteria growth, keeping the cooling liquid clean.
    240V AC—240V AC chillers have a bypass valve knob to control the chiller’s flow rate and pressure, which can affect the temperature of your liquid and how efficiently these coolers run.
    Overall
    Cooling Cap.,
    BTU/hr
    Current,
    amp
    Compressor
    Power, hp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Control
    Range, ° F
    Temp. Tolerance,
    ° F
    Ht.
    Wd.
    Dp.
    Tank Cap.,
    gal.
    Refrigerant
    No.
    Each
    120V AC (Single Phase)
    2,90013.71/43.5 gpm @ 90 psi9015 to 155-18 to 1821 7/8"15"26"1.1R-513A0000000000000000
    5,94017.41/23.5 gpm @ 90 psi9015 to 155-18 to 1821 7/8"15"26"1.1R-513A000000000000000
     
    240V AC (Single Phase)
    10,92015.51 1/46 gpm @ 45 psi4550 to 80-0.09 to 0.0930 9/16"14 1/8"31 13/16"1.5R-513A0000000000000000
    24,00033.4310 gpm @ 45 psi4550 to 80-0.09 to 0.0934 7/8"18"33 13/16"2.5R-513A0000000000000000
    36,00045.34 1/410 gpm @ 45 psi4550 to 80-0.09 to 0.0949 3/8"18"31 13/16"2.5R-513A00000000000000000
     

    Low-Temperature Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers. Low-Temperature Liquid Chillers.
    Chill coolant down to 0° F—the lowest temperature liquid chillers we offer. They're often used when you want to maintain temperatures below freezing, such as in food processing and for sensitive electronic components. They take your fluid down to a constant uniform temperature and pump that liquid into your cooling system. Monitor the temperature and pressure of the coolant on the LCD display and change the settings using the keypad. They have a window to quickly check the fluid level. This window also acts as a spot to drain or fill the chiller.
    Cannot Be Sold To—Liquid chillers cannot be sold to the listed areas due to chemical regulations.
    Overall
    Cooling Cap.,
    BTU/hr
    Voltage (Electrical
    Phase)
    Current,
    amp
    Compressor
    Power, hp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Control
    Range, ° F
    Ht.
    Wd.
    Dp.
    Tank Cap.,
    gal.
    Refrigerant
    No.
    Features
    Cannot Be
    Sold To
    Each
    For Closed-Loop Fluid Cooling Systems
    13,600460V AC (Three Phase)22210 gpm @ 28 psi1500 to 4054 3/8"31 5/8"31 5/8"12R-404ALiquid-Level Sight GlassCanada00000000000000000
     

    Rack-Mount Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers. Rack-Mount Liquid Chillers.
    Save floor space—these chillers mount to standard 19" electronics racks, enclosures, and cabinets. Because they're so compact, you can even fit multiple chillers on the same rack. Where other chillers only keep liquid cool within a few full degrees, these chillers are highly precise, maintaining constant, uniform temperatures within 0.18° F. This makes them ideal for equipment where small temperature changes could cause an issue for your process. Also called Peltier chillers, they cool using only electricity, so there's no compressors or refrigerants. Without a compressor, you'll hardly hear them when they're running.
    Fill these chillers with water or glycol solutions, and an internal pump moves the liquid through a cooling system and out to your equipment. There are multiple ways to control these chillers. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, pressure, and flow rate from the digital display. It will also display maintenance reminders and alarms.
    A port on the front lets you quickly check fluid levels and fill the chiller with fluid without removing it from the rack or disconnecting it from your system.
    Temp.
    Control
    Overall
    For Rack
    Wd.
    Cooling Cap.,
    BTU/hr
    Voltage (Electrical Phase)
    Current,
    amp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Range,
    ° F
    Method
    Ht.
    Wd.
    Dp.
    Tank Cap.,
    gal.
    Each
    For Closed-Loop Fluid Cooling Systems
     
    Thermoelectric Cooled
    19"600100V AC-240V AC (Single Phase)2.50.8 gpm @ 5 psi1050 to 140External Controller, Keypad7"19"13 1/2"0.30000000000000000
     

    Bench-Top Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers. Bench-Top Liquid Chillers.
    Send cool water to equipment right from your bench top without compromising precision. These chillers maintain constant, uniform temperatures within 0.2° F where other chillers only keep liquid cool within a few full degrees. This makes them ideal for equipment where small temperature changes could cause an issue, such as microscope cooling plates.
    Fill these chillers with water or glycol solutions, and an internal pump moves the liquid through a cooling system and out to your equipment. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, alerts, and other information from the LED display.
    500 BTU/hr Cooling Capacity—Chillers rated for 500 Btu/hr. are also known as Peltier chillers. They cool liquid using electricity—no need for compressors or refrigerants. Because they don’t use a compressor, you’ll hardly hear them when they’re on. To check fluid levels at a glance, their tank inlet is semi-clear.
    Overall
    Cooling Cap.,
    BTU/hr
    Wire
    Connection
    Voltage (Electrical
    Phase)
    Current,
    amp
    Compressor
    Power, hp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Control
    Range, ° F
    Ht.
    Wd.
    Dp.
    Accuracy
    Tank Cap.,
    fl. oz.
    Refrigerant
    No.
    Features
    Each
    For Closed-Loop Fluid Cooling Systems
     
    Thermoelectric Cooled
    500Wire Leads24V DC12.51 gpm @ 10 psi2050 to 1409 1/16"5 1/8"6 5/16"±0.4%4Semi-Clear Tank Inlet0000000000000000
     
    Refrigerant Cooled
    3,400120V AC (Single Phase)3.31/66 gpm @ 16 psi160 to 8018 7/16"9 1/8"18 3/16"±1.8%51R-134AUV Light System000000000000000
     